China Journal of Chinese Materia Medica ; (24): 598-602, 2011.
Article Dans Chinois | WPRIM | ID: wpr-247424

Résumé

A HPLC method was developed for the determination of mangiferin in rat plasma and aqueous humor. 4-Nitrophenol was used as internal standard. Analysis was performed on a Cosmosil ODS C18 analytical column (4.6 mm x 250 mm, 5 microm) with mobile phase consisting of methanol-water (40: 60) with 2% glacial acetic acid at a flow rate of 1.0 mL x min(-1). The calibration curve of mangiferin in rat plasma and aqueous humor showed excellent linear behaviors over the investigated concentration of 0. 50-250.00 mg x L(-1) in plasma and 0.10-10.00 mg x L(-1) in aqueous humor, respectively, and the correlation coefficients were all above 0.995 4. The intra-day and inter-day precisions for all samples were measured to be below 12%. The limit of quantitation was 0.10 mg x L(-1) and low enough for the determination of mangiferin in all samples. The validated method has been successfully applied to preliminary pharmacokinetics study of mangiferin in rat plasma and aqueous humor.


Sujets)
Animaux , Femelle , Mâle , Rats , Humeur aqueuse , Chimie , Chromatographie en phase liquide à haute performance , Nitrophénols , Rat Wistar , Reproductibilité des résultats , Sensibilité et spécificité , Xanthones , Sang , Pharmacocinétique