Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
Ajouter des filtres








Gamme d'année
1.
Journal of China Pharmaceutical University ; (6): 306-313, 2022.
Article Dans Chinois | WPRIM | ID: wpr-929468

Résumé

@#In this paper, the uncertainties of correction factors of fluconazole impurities determined by HPLC standard curve method were evaluated, and the main common factors affecting the accuracy of standard curve method were found, so as to improve the accuracy of the method.In this study, the corresponding fitting lines of fluconazole and its impurities A, B, C, D, F and I were established respectively, and the ratio of the slope of fitting lines of each impurity and its corresponding principal component was calculated as the correction factor of the impurity.Then on the basis of GUM method, the uncertainty of each impurity correction factor determined by standard curve method was evaluated according to the established uncertainty evaluation scheme of correction factor determination process.The correction factor and uncertainty of fluconazole impurities A, B, C, D, F and I were 1.068 ± 0.046, 0.102 ± 0.005, 0.0582 ± 0.0031, 1.382 ± 0.121, 0.802 ± 0.067 and 1.383 ± 0.119, respectively, and the coverage factor k was 2.Finally, the contribution rate of each uncertainty component was calculated.In the relative combined standard uncertainties urel(f) of fluconazole impurities A, B, C, D, F and I correction factors, the sum of contribution rate of slope uncertainty urel(K) of the linear equation of principal component and its impurity is more than 85%; in the slope uncertainties urel(K) of linear equation, the contribution rates of uncertainties of solution concentration in 8 of 12 data groups are more than 80%, and the contribution rates of uncertainties introduced by reference substance content in solution concentration are about 80%.It can be seen that the preparation of linear solution concentration is the most influential factor in the determination of impurity correction factor by standard curve method, followed by the linear fitting process.In the preparation process of linear solution concentration, the purity of reference substance is the most influential factor, followed by weighing and pipetting times.The conclusion can help the experimenters to better formulate experimental plans and ensure the accuracy of the results when doing similar work.

2.
China Pharmacy ; (12): 3428-3430, 2016.
Article Dans Chinois | WPRIM | ID: wpr-504928

Résumé

OBJECTIVE:To a evaluation method for the measurement uncertainty for the content of Bisacodyl enteric-coated tablet. METHODS:HPLC external standard method was conducted for content determination of Bisacodyl enteric-coated tablet, and mathematical model for uncertainty evaluation was established to systematically analyze and evaluate the influential factors in processes of solution preparation and instrument measurement. RESULTS:HPLC external standard method showed the content was 97.8%,confidence probability was 95%,expanded uncertainty was 2.8%,and determination result was (97.8 ± 2.8)%,k=2. CONCLUSIONS:The established method is suitable for the evaluation of measurement uncertainty for the content of Bisacodyl en-teric-coated tablet. Regularly calibrated verification for HPLC equipment and strict control of the weighing process will help to im-prove the accuracy measured by HPLC.

SÉLECTION CITATIONS
Détails de la recherche