Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Journal of Korean Medical Science ; : e22-2020.
Artigo em Inglês | WPRIM | ID: wpr-899797

RESUMO

BACKGROUND@#Central dark-signal intensity with high-signal, hypertrophic mucosal wall of paranasal sinuses on T2-weighted images (T2WI) is a characteristic magnetic resonance imaging (MRI) feature of sinonasal fungus ball. However, this finding is usually interpreted as non-fungal chronic sinusitis with central normal sinus air. In addition, T1-weighted images (T1WI) and T2WI are basic sequences of all magnetic resonance (MR) examinations. Therefore, we evaluated the usefulness of T1WI for detecting fungus balls comparing with computed tomography (CT) findings and T2-weighted MRI findings.@*METHODS@#This retrospective study was approved by the Institutional Review Board of Korea University Guro Hospital. Two reviewers assessed preoperative CT and MR images of 55 patients with pathologically confirmed fungus balls. Reviewers evaluated the presence and patterns of calcifications on CT. Overall signals and the presence and extent of certain signals of fungus balls on MRI were also assessed. The relationship between calcifications and MRI signals was also evaluated.@*RESULTS@#Of the patients, 89.1% had calcifications on CT. All had dark signal portions with high signal, hypertrophic mucosal walls on T2WI. Most (92.7%) patients showed iso- to hyper-intense overall signals on T1WI and 89.1% had T1-weighted high signal portions on MRI. The presence, patterns, and location of calcifications had no significant correlation with T1-weighted high-signal intensity portion.@*CONCLUSION@#Fungus ball can be suggested by the presence of the hyper-signal intensity portions in the fungal mass on T1WI in conjunction with dark-signal lesions surrounded by high-signal, hypertrophic mucosal walls in paranasal sinuses on T2WI.

2.
Journal of Korean Medical Science ; : e22-2020.
Artigo em Inglês | WPRIM | ID: wpr-892093

RESUMO

BACKGROUND@#Central dark-signal intensity with high-signal, hypertrophic mucosal wall of paranasal sinuses on T2-weighted images (T2WI) is a characteristic magnetic resonance imaging (MRI) feature of sinonasal fungus ball. However, this finding is usually interpreted as non-fungal chronic sinusitis with central normal sinus air. In addition, T1-weighted images (T1WI) and T2WI are basic sequences of all magnetic resonance (MR) examinations. Therefore, we evaluated the usefulness of T1WI for detecting fungus balls comparing with computed tomography (CT) findings and T2-weighted MRI findings.@*METHODS@#This retrospective study was approved by the Institutional Review Board of Korea University Guro Hospital. Two reviewers assessed preoperative CT and MR images of 55 patients with pathologically confirmed fungus balls. Reviewers evaluated the presence and patterns of calcifications on CT. Overall signals and the presence and extent of certain signals of fungus balls on MRI were also assessed. The relationship between calcifications and MRI signals was also evaluated.@*RESULTS@#Of the patients, 89.1% had calcifications on CT. All had dark signal portions with high signal, hypertrophic mucosal walls on T2WI. Most (92.7%) patients showed iso- to hyper-intense overall signals on T1WI and 89.1% had T1-weighted high signal portions on MRI. The presence, patterns, and location of calcifications had no significant correlation with T1-weighted high-signal intensity portion.@*CONCLUSION@#Fungus ball can be suggested by the presence of the hyper-signal intensity portions in the fungal mass on T1WI in conjunction with dark-signal lesions surrounded by high-signal, hypertrophic mucosal walls in paranasal sinuses on T2WI.

4.
Journal of Breast Cancer ; : 270-278, 2014.
Artigo em Inglês | WPRIM | ID: wpr-225645

RESUMO

PURPOSE: The aim of this study is to describe our initial experience with magnetic resonance (MR)-guided biopsy and to determine the malignancy rate of additional lesions identified by MR only in Korean women with breast cancer. METHODS: A retrospective review identified 22 consecutive patients with breast cancer who had undergone MR-guided vacuum-assisted biopsies (VAB) of MR-only identified lesions from May 2009 to October 2011.We evaluated the rate of compliance, the technical success for MR-guided VAB and the MR imaging findings of the target lesions. VAB histology was compared with surgical histology and follow-up imaging findings. RESULTS: The biopsy recommendations for MR-only identified lesions were accepted in 46.8% (22/47) of patients. One of 22 procedures failed due to the target's posterior location. Among 21 MR-guided VAB procedures, the target lesions were considered as a mass in 12 cases and a nonmass enhancement in nine cases. VAB histology revealed malignancies in 14% (3/21) of cases, high-risk lesions in 24% (5/21) and benign lesions in 62% (13/21). Eleven cases (52%, 11/21) had a positive surgical correlation, and one of them was upgraded from atypical ductal hyperplasia to invasive ductal carcinoma. In the remaining 10 lesions, follow-up breast ultrasound and mammography were available (range, 15-44 months; mean, 32.1 months) and did not show suspicious lesions. The final malignancy rate was 19% (4/21). CONCLUSION: MR-guided VAB for MR-only identified lesions yielded a 19% malignancy rate in Korean women with breast cancer. MR-guided VAB helps surgeons avoid an unnecessary wide excision or additional excisional biopsy.


Assuntos
Feminino , Humanos , Biópsia , Mama , Neoplasias da Mama , Carcinoma Ductal , Complacência (Medida de Distensibilidade) , Seguimentos , Hiperplasia , Biópsia Guiada por Imagem , Imageamento por Ressonância Magnética , Imagem por Ressonância Magnética Intervencionista , Mamografia , Estudos Retrospectivos , Ultrassonografia
5.
Korean Journal of Radiology ; : 136-143, 2012.
Artigo em Inglês | WPRIM | ID: wpr-112476

RESUMO

OBJECTIVE: We investigated low dose digital tomosynthesis (DT) for the evaluation of the paranasal sinus (PNS), and compared its diagnostic accuracy with a PNS radiography series (XR). MATERIALS AND METHODS: We enrolled 43 patients for whom XR, PNS DT, and OMU CT were performed. We measured effective doses (EDs) of XR, DT, and OMU CT using Monte Carlo simulation software. Two radiologists performed independent observation of both XR and DT. For seven PNSs, they scored anatomic conspicuity of sinuses and confidence on the presence of sinusitis using nine point scales. OMU CT was observed by the third radiologist and the findings were regarded as reference standard. We compared scores for conspicuity and sinusitis confidence between XR and DT. RESULTS: Mean EDs were 29 +/- 6 microSv, 48 +/- 10 microSv, and 980 +/- 250 microSv, respectively, for XR, DT, and CT. Mean scores for conspicuity were 6.3 and 7.4, respectively, for XR and DT. Sensitivity per patient basis for sinusitis detection were 52% and 96%, respectively, for XR and DT in observer 1 (p = 0.001) and 80% and 92% for observer 2 (p = 0.25). Specificities for sinusitis exclusion were 100% for both XR and DT for observer 1 and 89% and 100% for observer 2 (p = 0.50). Accuracies for sinusitis diagnosis were 72% and 98%, respectively, for XR and DT for observer 1 (p = 0.001) and 84% and 95% for observer 2 (p = 0.125). CONCLUSION: Patient radiation dose from low dose DT is comparable with that of PNS XR. Diagnostic sensitivity of DT for sinusitis was superior to PNS XR.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Seios Paranasais/diagnóstico por imagem , Curva ROC , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Sensibilidade e Especificidade , Sinusite/diagnóstico por imagem , Estatísticas não Paramétricas , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA