Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of the Korean Association of Maxillofacial Plastic and Reconstructive Surgeons ; : 443-452, 2004.
Artigo em Coreano | WPRIM | ID: wpr-784577
3.
Journal of the Korean Association of Oral and Maxillofacial Surgeons ; : 175-180, 2004.
Artigo em Coreano | WPRIM | ID: wpr-122549

RESUMO

In this study, three treatment options to replace two posterior missing teeth were investigated using three dimensional finite element analysis: two wide(.5.0mm) implants(the experimental model I), two standard(.3.75mm) implants(the experimental model II), and three standard(.3.75mm) implants(the experimental model III). Two kinds of load case were applied ; 1) perpendicular on occlusal surface(axial load), parallel on occlusal surface(lateral load). 2) perpendicular on occlusal surface(3mm lateral to central point). The results obtained from this study were as follows; value of on-mises stress (equivalent stress) was smallest in the two wide implant among the three experimental models. It was reported that the diameter is the efficient factor than osseointegrated surface area.


Assuntos
Análise de Elementos Finitos , Modelos Teóricos , Dente
4.
Korean Journal of Orthodontics ; : 11-20, 2003.
Artigo em Coreano | WPRIM | ID: wpr-653480

RESUMO

The purpose of the present study is to evaluate the stress distribution on the length and diameter of the miniscrew and cortical bone width. Three dimensional finite element models were made of diameter 1.2mm, 1.6mm, 2.0mm and length 6.0mm, 8.0mm, 10.0mm, 12.0mm and cortical bone width 1.0mm. Also, another three dimensional finite element models were made of diameter 1.2mm, 1.6mm, 2.0mm and length 8.0mm and cortical bone width 1.0mm, 1.5mm, 2.0mm, 2.5mm. Two-hundred grams horizontal force were applied on the center of the miniscrew head and at that stress distribution and its magnitude had been analyzed by ANSYS, which is three dimensional finite element analysis program. The obtained results were as follows : 1. The comparison of the maximum von-Mises stress in the miniscrew showed that as the diameter increases from 1.2mm to 2.0mm stress has been decreased, while on the same diameter stress was not changed regardless of the length change. 2. The comparison of the maximum von-Mises stress in the cortical and cancellous bone showed that as the diameter increases from 1.2mm to 2.0mm stress has been decreased, while on the same diameter stress was not changed regardless of the length change. 3. In the analysis of the stress distribution in the cortical and cancellous bone, the most of the stress had been absorbed in the cortical bone, and did not transmitted much to the cancellous bone. 4. In the analysis of the maximum von-Mises stress according to the cortical bone width, the same diameter of the miniscrew showed a constant stress value regardless of the cortical bone width change. The above results suggest that the maintenance of the miniscrew is more reliable on diameter than length of the miniscrew.


Assuntos
Análise de Elementos Finitos , Cabeça
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA