Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. bras. ortop ; 50(6): 666-672, Nov.-Dec. 2015. tab, graf
Artigo em Português | LILACS | ID: lil-769990

RESUMO

To measure the quality of life and clinical-functional results from patients diagnosed with osteoarthrosis of the distal radioulnar joint who underwent surgical treatment using the technique of total arthroplasty of the ulna, with a total or partial Ascension(r) prosthesis of the distal ulna.METHODS:Ten patients were evaluated after 12 months of follow-up subsequent to total or partial arthroplasty of the distal ulna. All of them presented post-traumatic osteoarthrosis and/or chronic symptomatic instability of the distal radioulnar joint. The study was prospective. Seven patients had previously undergone wrist procedures (two cases with Darrach, three with Sauvé-Kapandji and two with ligament reconstruction of the fibrocartilage complex) and three presented fractures of the distal ulna that evolved with pain, instability and osteoarthrosis of the distal radioulnar joint. The following were assessed: quality of life (DASH scale); percentage degree of palm grip strength (kgf) and pronosupination range of motion in relation to the unaffected side; pain (VAS); return to work; subjective evaluation of radiography; and complications...


Mensurar a qualidade de vida e os resultados clínico-funcionais dos pacientes com diagnóstico de osteoartrose da radioulnar distal submetidos ao tratamento cirúrgico pela técnica de artroplastia total da ulna com a prótese total ou parcial Ascension(r)da ulna distal. MÉTODOS: Foram avaliados 10 pacientes com 12 meses de seguimento de artroplastia total ou parcial de ulna distal. Todos apresentavam osteoartrose pós-traumática e ou instabilidade crônica e sintomática da articulação radioulnar distal. O estudo foi prospectivo. Sete pacientes tinham procedimentos prévios no punho (2-darrach, 3-Sauvé-kapandji, 2-reconstruções ligamentares do complexo da fibrocartilagem) e três apresentaram fraturas da ulna distal que evoluíram com dor, instabilidade e osteoartrose da radioulnar distal. Foram analisados a qualidade de vida (DASH), a porcentagem do grau de força de preensão palmar (kgf) e o arco de movimento de pronossupinação em relação ao lado não afetado, a dor (VAS), o retorno ao trabalho e a avaliação subjetiva da radiografia e das complicações...


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto Jovem , Pessoa de Meia-Idade , Prótese Articular , Fraturas do Rádio , Fraturas da Ulna
2.
Rev. bras. ortop ; 50(5): 509-514, set.-out. 2015. tab, graf
Artigo em Português | LILACS | ID: lil-766244

RESUMO

Comparar os parâmetros mecânicos entre dois métodos de estabilização por com pressão: placa de compressão axial de 1,5 mm com o parafuso cônico de compressão usado como tutor intramedular. Métodos: Foram usados modelos de poliuretano (Sawbone(r)) que simulam a fratura da falange proximal transversa, divididos em três grupos (placa lateral, parafuso cônico, sem implante). Resultados: Há necessidade de uma maior força para resultar na fadiga da síntese com para fuso intramedular. Comprova-se, assim, a supremacia mecânica desse sobre o modelo com a placa lateral. Conclusão: A estabilização com o parafuso Acutrak(r), no tratamento das fraturas no modelo adotado neste ensaio, apresenta resultados mecânicos superiores e estatisticamente sig nificativos em comparacão com a técnica de compressão axial com o uso da placa lateral (Aptus Hand (r)).


To compare the mechanical parameters between two methods for stabilization through compression: 1.5 mm axial compression plate versus conical compression screw used as an intramedullary tutor. METHODS: Polyurethane models (Sawbone(r)) that simulated transverse fractures of the proximal phalanx were used. The models were divided into three groups: lateral plate, conical screw and no implant. RESULTS: Greater force was needed to result in fatigue in the synthesis using an intramedullary plate. Thus, this model was proven to be mechanically superior to the model with the lateral plate. CONCLUSION: Stabilization using the Acutrak(r) screw for treating fractures in the model used in this trial presents mechanical results that are statistically significantly superior to those from the axial compression technique using the lateral plate (Aptus Hand(r)).


Assuntos
Traumatismos dos Dedos , Fixação de Fratura , Fixação Interna de Fraturas , Traumatismos da Mão
3.
Rev. bras. ortop ; 49(3): 218-226, May-June/2014. tab
Artigo em Inglês | LILACS | ID: lil-712780

RESUMO

OBJECTIVES: the purpose of this study was to compare the postoperative radiological and clinical outcomes with minimally invasive percutaneous osteosynthesis using three implants: volar locking plate, intramedullary nail system and nonbridging external fixator for distal radius fractures. METHODS: forty-eight patients (A group, 16; B group 16; C group 16) underwent minimally invasive percutaneous osteosynthesis of reductible and unstable displaced (Type IIB by Rayhack Classification) distal radius fractures. In B group intramedullary nail system was used, in A group the patients were treated with volar locking plate and in C group the patients were treated by nonbridging external fixator from January 2011 to December 2012. The mean follow-up period was 12 months. Radiologic parameters, range of motion, grip strength, and disability of the arm, shoulder, and hand score were evaluated at each examination (3rd and 6th week, and 12th months). The visual analog scale of wrist pain and complications were assessed at the final follow-up. RESULTS: the groups did not differ significantly in radiological outcomes after 12 months, but the clinical results, VAS scale and dash score in group A (volar locking plate) and B (nail intramedullary) were statistically significantly better than that of C group (nonbridging external fixator). One patient underwent an osteosynthesis with nail intramedullary and another with external fixator (C group) developed persistent pain near the site of the superficial radial nerve because of the distal's screw and pins, respectively. CONCLUSION: in clinical parameters, significant differences in outcomes were found between groups A and B after six weeks versus C group...


OBJETIVOS: comparar o resultado clínico funcional dos pacientes com diagnóstico de fratura com desvio, redutível e instável da extremidade distal do rádio submetidos ao tratamento cirúrgico pela técnica de osteossíntese percutânea e minimamente invasiva com o uso de três tipos de implante: placa volar bloqueada, haste intramedular bloqueada e fixador externo. Comparar os resultados quanto à melhoria da qualidade de vida pelo questionário Dash e ao tempo de retorno ao trabalho. MÉTODOS: divididos em três grupos (A, placa - 16; B, haste - 16; C, fixador externo - 16), 48 pacientes foram submetidos ao tratamento cirúrgico da fratura da extremidade distal do rádio, redutível e instável, classificação Rayhack (Tipo IIB), pelo método minimamente invasivo, com três tipos de implante: haste intramedular bloqueada, placa volar bloqueada e fixador externo radio-radial. Estudo feito de janeiro de 2011 a dezembro de 2012. O tempo de seguimento foi de 12 meses. Parâmetros radiográficos, dor (escala VAS), medida do arco de movimento, força de preensão palmar e o questionário Dash foram avaliados na terceira e sexta semana e no sexto mês de pós-operatório. RESULTADOS: numa análise vertical dos valores apresentados, observamos uma melhoria estatística significativa em todos os parâmetros clínicos analisados no estudo, nos três grupos. Em relação à análise horizontal, ou seja, na comparação dos grupos entre si, não houve diferenças estatísticas significativas quanto aos parâmetros radiográficos após o 12° mês de seguimento. O grau de força de preensão palmar, a medida do arco de movimento, VAS e Dash apresentaram, na terceira e sexta semana de pós-operatório, valores estatísticos...


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto Jovem , Pessoa de Meia-Idade , Placas Ósseas , Fixação Interna de Fraturas , Fraturas do Rádio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA