Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Adicionar filtros








Intervalo de ano
1.
Artigo em Chinês | WPRIM | ID: wpr-1026344

RESUMO

Purpose To construct a benign and malignant prediction model of thyroid nodules based on ultrasound image features and clinical features,and to evaluate its diagnostic efficacy.Materials and Methods The data of 121 patients diagnosed with thyroid nodules admitted to the General Hospital of Northern Theater Command from September 2020 to March 2022 were retrospectively analyzed.Taken surgical pathology as the gold standard,there were 70 benign nodules and 51 malignant nodules.Logistic regression was used to analyze the ultrasound image characteristics and clinical data of thyroid nodules,and the characteristic indexes with statistical differences were obtained and a comprehensive prediction model was established.Results There were significant differences in the maximum diameter,morphology,calcification,capsule continuity,blood flow grade,elastography score and contrast-enhanced ultrasound characteristics between benign and malignant thyroid nodules(χ2=11.709,17.707,6.901,12.785,16.984,57.095,98.854,all P<0.05).There were significant differences in age,free thyroxine/free thyroxine ratio,and free thyroxine between the two groups(χ2/t=5.944,2.519,-2.468,all P<0.05).The sensitivity,specificity and accuracy of the clinical model,ultrasonic characteristic model and ultrasonic-clinical combined model were 55.7%,98.6%and 97.0%;72.5%,94.1%and 96.1%;and 61.9%,95.1%and 95.9%,respectively.The area under the curve of the three models were 0.619,0.991 and 0.994,respectively.The diagnostic efficiency of the ultrasonic characteristic model and the combined model was superior to the clinical model,and the difference was statistically significant(Z=-1.75,-2.25,P=0.039,0.012).The area under the curve of the combined model was greater than that of the multi-modal ultrasound model,however,the difference was not statistically significant(Z=-1.60,P=0.054).Conclusion Both the multimodal ultrasound model and the clinical model have certain diagnostic value in predicting benign and malignant thyroid nodules.The diagnostic efficiency of the multimodal ultrasound model is higher than that of the clinical model,and the combined prediction model of the two can improve the diagnostic value.

2.
Artigo em Chinês | WPRIM | ID: wpr-513943

RESUMO

Objective To investigate the integrated backscatter(IBS) changes of retina in hypertensive disease patients to offer the reference to clinician for ocular fundus changes of hypertensive disease.Methods One hundred chronic hypertension patients (100 eyes) were divided into 4 groups by clinical stages:① gradeⅠ,28 persons (28 eyes);② grade Ⅱ,27 persons (27 eyes);③ grade Ⅲ,24 persons (24 eyes);④ grade Ⅳ,21 persons (21 eyes).Thirty normal persons of 30 eyes were the control group.Their IBS values were measured on nose side of retina,and the correction IBS values(IBS%) were calculated.Results With the deterioration of hypertensive disease,the IBS(29.48±0.09,32.50±0.04,34.62±0.39,36.48±0.46,37.52±0.43) and IBS%[(68.50±2.11)%,(72.03±0.57)%,(74.29±0.77)%,(76.06±1.43)%,(77.45±0.75)%] of retina were gradually increased.The statistical difference were found among various groups(P=0.000).Conclusions With the deterioration of hypertensive retinopathy,the IBS and IBS% increased gradually.The IBS technique is a useful method to assess the retinopathy of hypertension.

3.
Artigo em Chinês | WPRIM | ID: wpr-712051

RESUMO

Objective To explore the value of acoustic radiation force impulse imaging (ARFI) technique in the evaluation of the change of kidney in rabbits with hypothermia and rewarming. Methods Sixteen New Zealand rabbits were placed in -25 ℃ environment for 8 hours, then rewarmed in 23℃ environment. Ultrasonic examinations were performed at room temperature in the time of T0and the time of T1-T8. The right kidney were evaluated by two-dimensional ultrasound and ARFI technique. Results No significant changes were found in the echo and volume of kidney from T1to T8. SWV of kidney descended greatly from T0to T1and raised from T2to T3gradually, then it descended from T3to T8gradually. Significant difference of SWV of kidney were found from T1to T8compared with that at T0(P < 0.05). Conclusions ARFI Technique can estimate the change of kidney in rabbits with hypothermia and rewarming. It can provide more useful information for clinical diagnosis.

4.
Artigo em Chinês | WPRIM | ID: wpr-460620

RESUMO

Objective To evaluate the clinical effect of ultrasound-guided percutaneous transhepatic cholangial drainage (PTCD) combined with endoscopic retrograde cholangio-pancreatography (ERCP) in treating malignant obstructive jaundice, and to discuss its technical points. Methods A total of ten cases with malignant biliary obstruction were enrolled in this study. After the failure of ERCP treatment, the patients had to be treated with ultrasound-guided PTCD immediately. The guide-wire was inserted into the duodenum through intrahepatic bile duct and common bile duct to connect with ERCP, which was followed by the biliary stent implantation or the removal of physical factors causing obstruction. The clinical results were analyzed. Results Technical success was obtained in all 10 cases. In the patients who underwent a successful guide-wire docking with ERCP the postoperative serum bilirubin was significantly decreased. The main complications were fever, elevation of amylase and transient bloody bile. Conclusion With the help of docking technique the combination use of ultrasound-guided PTCD and ERCP is a new tentative treatment for malignant obstructive jaundice after the failure of initial ERCP treatment. This technique carries promising value in clinical practice as it can significantly increase the success rate of ERCP.

5.
Artigo em Chinês | WPRIM | ID: wpr-637655

RESUMO

ObjectiveTo explore the change of renal cortical perfusion in rabbits by microbubbles-enhanced ultrasound cavitation.MethodsTotally 20 New Zealand rabbits were randomly divided into four groups, 5 rabbits in each group. SonoVue was injected via the ear vein at a dose of 0.1 ml/kg. The renal perfusion imaging 30 s modeling was made. Under the mode of contrast enhancement, the rabbit kidneys irradiated with different mechanical indexs (MI) were 0.6 (MI 0.6 group) , 0.75 (MI 0.75 group) , 1.1 (MI 1.1 group) and 1.3 (MI 1.3 group) for 60 s, 15 min respectively. After the irradiation and conventional ultrasound contrast was made again, the renal perfusion imaging was mad. The time-intensity curves (TIC) were analyzed obtained from the following parameters: the slope rate of ascending curve (A) , the slope rate of descending curve (α) , area under the curve (AUC) , time to peak (TTP) , and derived peak intensity (DPI) . One-way ANOVA and LSD-t were used to analyze all experimental data.ResultsCompared with the MI 0.6 group, the MI 1.1 group and the MI1.3 group, the A, α were less than MI 0.6 group, the AUC, DPI, TTP were greater than MI 0.6 group, and the differences were statistically signiifcant (MI 1.1 groupvs MI 0.6 group:t=3.13, 5.31, 4.25, 4.53, 5.72, allP<0.05; MI 1.3 groupvs MI 0.6 group:t=3.67, 6.23, 4.47, 5.48, 6.86, allP<0.05). Compared with the MI 0.75 group, the MI 1.1 group and the MI 1.3 group, the α were less than MI 0.75 group, the AUC, DPI, TTP were greater than MI 0.75 group, and the differences were statistically signiifcant (MI 1.1 groupvs MI 0.75 group:t=6.02, 4.36, 4.85, 5.83, allP<0.05; MI 1.3 groupvs MI 0.75 group:t=6.19, 4.51, 5.73, 6.97, allP<0.05); the MI 1.1 group and the MI 1.3 group, the A were less than MI 0.75 group, and the difference were not statistically signiifcant. The MI 1.1 group and the MI 1.3 group, the MI 0.6 and the MI 0.75 group, and the difference were not statistically signiifcant.ConclusionsTo the change of hemodynamic of the rabbits renal cortical perfusion in the microbubbles-enhanced ultrasound cavitation contrast agent can be observed. Along with the mechanical index increased renal cortical perfusion flow stasis and the perfusion on of slowed in rabbit, may cause renal damage, the TIC curve displayed further changes.

6.
Artigo em Chinês | WPRIM | ID: wpr-443173

RESUMO

Objective Objective To investigate the relationship between choroidopathy and integrated backscatter(IBS) of choroid in diabetes mellitus(DM) patients.Methods Eighty DM patients of 158 eyes were divided into 3 groups by the course of diabetic retinopathy(DR)-DM patients without DR group,DM patients with the background DR,DM patients with the proliferative DR.80 normal persons of 160 eyes were the control group.Their IBS values were measured on nose side,temple side and middle side of choroid by HP Sonos 5500,and the correction IBS values(IBS%) were calculated.Results With the deterioration of DR,the IBS and IBS% of choroid increased.The statistical significance difference were found in various groups(P < 0.01).Conclusions With the deterioration of diabetic choroidopathy,the IBS and IBS% increased.The IBS technique is useful method to assess the diabetic choroidopathy.

7.
Artigo em Chinês | WPRIM | ID: wpr-444677

RESUMO

Objective To discuss the best method to treat deep perianal abscess and to investigate the clinical efficacy and value of the procedure of percutaneous catheter drainage guided by ultrasound in treatment.Ninteen patients with deep abscess underwent the procedure from Jan.2012 to May.2013.Methods Clinical data of 19 patients were analyzed retrospectively,including 16 male cases and 3 female cases.Results The average age is 39.8.All patients were cured without complications.The average length of stay is 7.8 days,a mean follow-up of 6.6 months after discharge,no patient with recurrence or fistula.Conclusion No specific performance of colorectal carcinoid,surgical resection is the most effective method of the treatment of colorectal carcinoid,the procedure should be individual treatment.However,the long term prognosis need to be explored in the future.

8.
Artigo em Chinês | WPRIM | ID: wpr-419363

RESUMO

Objective To explore the value of contrast-enhanced ultrasound(CEUS) in the evaluation of the renal cortical perfusion in rabbits in low temperature conditions.Methods 20 New Zealand rabbits were randomly divided into five groups,4 rabbits in each group:1) with the first group as the control group (under the conditions of room temperature) ; 2)The second group was treated under-15℃--23℃ for 8hours; 3)the third group was treated under-15℃--23℃ for 4 hours; 4)the fourth group was treated under-6℃--14℃ for 8 hours; 5) the fifth group was treated under-6℃--14℃ for 4 hours.SonoVue was injected via the ear vein at a dose of 0.1 ml/kg,the renal perfusion imaging was made,observing the dynamic image of 0-3 min after the injection and analyzing the time-intensity curves(TIC)obtained from the following parameters:the slope rate of ascending curve(A),the slope rate of descending curve(α),area under the curve (AUC),time to peak (TTP),and derived peak intensity(DPI).Results Compared with the control group,the A,α of the second and the fourth group were significantly decreased (P < 0.05),while the AUC was significantly increased (P < 0.05) and the TTP was significantly prolonged(P <0.05),for the third and the fifth group,only the A was decreased (P <0.05),and the DPI in each group showed no significant difference.Compared with the third and the fourth group,the AUC of the second group was increased and the TTP was prolonged (P <0.05).Conclusions Contrast-enhanced ultrasound can reflect the earlier renal cortical hemodynamic changes in rabbits in the low-temperature conditions,and is of great value for the early diagnosis of renal damage caused by low temperature.

9.
Artigo em Chinês | WPRIM | ID: wpr-399663

RESUMO

Objective To elevate the achievement rate of kidney biopsy puncture through the analysis of puncture angle choice of ultrasound guided automatic kidney biopsy in 518 patients. Methods Under the guidance of color Doppler ultrasound,using the 3.5MHz probe with probe holder,we performed kidney biopsy in the degrees of 40°(group X),45°(group Y),60°(group Z) and 70°(group P) with the horizontal plane. Resnlts The total achievement ratio is 100 %. The one time success rate in group Y and group Z is 100 % (group Y, 164/164 ; group Z, 186/186) ;group X is 4.8% (22/46) ;group P is 84.4% (103/122).Conclusion The automatic kidney biopsy an- gle under the guidance of ultrasound should be between 45° and 60° with the horizontal plane which is safe and has higher achievement ratio. In the meantime, complications can be avoided.

10.
Artigo em Chinês | WPRIM | ID: wpr-576954

RESUMO

Objective: To explore the value of integrated backscatter(IBS) of kidney with different dosage of organophosphorus in rabbits. Methods: Animal models of organophosphorus poisoning were established. Ultrasonographic examinations were performed on four different dosage experimental groups and control group at 1h and 3 h after rabbits being poisoned.The echo and the size of kidney were evaluated by two-dimensional ultrasound.The changes of parenchyma were quantitatively analyzed by IBS.Results: No significant changes were found in kidney echo of any groups.With the increasing dosage and prolonging time of poisoning,significant changes were found in volume and length of kidneys comparing with that of control group(P

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA