Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
J. appl. oral sci ; 21(4): 346-350, Jul-Aug/2013. graf
Artigo em Inglês | LILACS | ID: lil-684575

RESUMO

OBJECTIVE: The goal of this study was to evaluate the efficacy of the Self-Adjusting File (SAF) and ProTaper for removing calcium hydroxide [Ca(OH)2] from root canals. MATERIAL AND METHODS: Thirty-six human mandibular incisors were instrumented with the ProTaper system up to instrument F2 and filled with a Ca(OH)2-based dressing. After 7 days, specimens were distributed in two groups (n=15) according to the method of Ca(OH)2 removal. Group I (SAF) was irrigated with 5 mL of NaOCl and SAF was used for 30 seconds under constant irrigation with 5 mL of NaOCl using the Vatea irrigation device, followed by irrigation with 3 mL of EDTA and 5 mL of NaOCl. Group II (ProTaper) was irrigated with 5 mL of NaOCl, the F2 instrument was used for 30 seconds, followed by irrigation with 5 mL of NaOCl, 3 mL of EDTA, and 5 mL of NaOCl. In 3 teeth Ca(OH)2 was not removed (positive control) and in 3 teeth canals were not filled with Ca(OH)2 (negative control). Teeth were sectioned and prepared for the scanning electron microscopy. The amounts of residual Ca(OH)2 were evaluated in the middle and apical thirds using a 5-score system. RESULTS: None of the techniques completely removed the Ca(OH)2 dressing. No difference was observed between SAF and ProTaper in removing Ca(OH)2 in the middle (P=0.11) and the apical (P=0.23) thirds. CONCLUSION: The SAF system showed similar efficacy to rotary instrument for removal of Ca(OH)2 from mandibular incisor root canals. .


Assuntos
Humanos , Hidróxido de Cálcio , Instrumentos Odontológicos , Cavidade Pulpar , Irrigantes do Canal Radicular/química , Preparo de Canal Radicular/instrumentação , Ácido Edético/química , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Hipoclorito de Sódio/química , Fatores de Tempo , Irrigação Terapêutica/métodos
2.
Braz. dent. j ; 19(3): 228-231, 2008. graf
Artigo em Inglês | LILACS | ID: lil-495978

RESUMO

This study evaluated in vitro the cytotoxicity of four root canal sealers (Topseal, EndoRez, TubliSeal and Kerr Pulp Canal Sealer E.W.T.) and their effects on reactive oxygen/nitrogen intermediate induction by mouse peritoneal macrophages. Thioglycollate-induced cells were obtained from Swiss mice by peritoneal lavage with 5 mL 10 mM phosphate-buffered saline, washed twice and resuspended (106 cells/mL) in appropriate medium for each test. Cytotoxicity was determined by the presence of hydrogen peroxide (H2O2) and nitric oxide (NO) by the peroxidase-dependent oxidation of phenol red and Griess reaction, respectively. Sealer suspensions were obtained in two different concentrations from each material: 18 mg/mL and 9 mg/mL, established according to compatibility parameters following MTT assay. Comparing the sealers, H2O2 release at concentrations of 9 mg/mL and 18 mg/mL was similar: Topseal > positive control (medium + cells + 5 mg/mL zimozan solution) > EndoRez > TubliSeal > Kerr Pulp E.W.T. > negative control (medium + cells). NO release at concentration of 9 mg/mL was: positive control (medium + cells + 10 µg/mL LPS solution) > Topseal > Kerr Pulp E.W.T. > TubliSeal = EndoRez > negative control (medium + cells); at concentration of 18 mg/mL was: positive control > Topseal > Kerr Pulp E.W.T > TubliSeal > EndoRez > negative control. Based on the results, it may be concluded that Topseal presented the highest cytotoxicity among the tested sealers, releasing higher concentrations of NO and H2O2 in macrophage culture.


Este estudo avaliou in vitro a citotoxicidade de quatro cimentos obturadores (Topseal, EndoRez, TubliSeal e Kerr Pulp Canal Sealer E.W.T) e seus efeitos na liberação de reativos intermediários do oxigênio e do nitrogênio em cultura de macrófagos peritoniais de ratos.Tioglicolato foi utlizado para se obter células peritoneias de camundongos. A cavidade peritoneal foi irrigada com 5 mL de solução salina 10 mM. As células foram lavadas duas vezes e foi feita uma suspensão (106 células/mL) em meio apropriado para cada um dos testes. A citotoxicidade dos cimentos foi determinada pela presença de peróxido de hidrogênio (H2O2) e óxido nítrico (NO) pela oxidação peroxidase-dependente do vermelho fenol e pela reação de Griess, respectivamente. Suspensões de cimento foram obtidas em duas diferentes concentrações para cada material: 18 mg/mL e 9 mg/mL, estabelecidas previamente pelo teste de viabilidade celular MTT. Comparando os cimentos, a liberação de H2O2 foi similar nas duas concentrações: Topseal > controle positivo (meio + células + Zimozan a 5mg/mL ) > EndoRez > TubliSeal > Kerr Pulp E.W.T. > controle negativo (meio + células). A liberação de NO na concentração de 9 mg/mL foi: de 9 mg/mL foi: controle positivo (meio + células + solução de LPS a 10 »g/mL) > Topseal > Kerr Pulp E.W.T. > TubliSeal = EndoRez > controle negativo (meio + células); e na concentração de 18 mg/mL; e na concentração de 18 mg/mL: controle positivo > Topseal > Kerr Pulp E.W.T > TubliSeal > EndoRez > controle negativo. Baseado nos resultados, pode-se concluir que o Topseal apresentou a maior citotoxicidade dentre os cimentos avaliados, liberando as mais altas concentrações de NO e H2O2 em cultura de macrófagos.


Assuntos
Animais , Camundongos , Macrófagos Peritoneais/efeitos dos fármacos , Materiais Restauradores do Canal Radicular/toxicidade , Células Cultivadas , Corantes , Resinas Compostas/toxicidade , Resinas Epóxi/toxicidade , Sequestradores de Radicais Livres/análise , Peróxido de Hidrogênio/análise , Teste de Materiais , Óxido Nítrico/análise , Oxidantes/análise , Espécies Reativas de Oxigênio/análise , Sais de Tetrazólio , Tiazóis , Cimento de Óxido de Zinco e Eugenol/toxicidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA