Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Korean Academy of Fundamental Nursing ; : 165-175, 2018.
Artigo em Coreano | WPRIM | ID: wpr-716185

RESUMO

PURPOSE: The purposes of this study were to examine symptom experiences, perceived health status, disease status, and self-care compliance of patients with liver cirrhosis and to identify the factors that affect their self-care compliance. METHODS: The study design was a cross-sectional design and 148 patients who were being treated at D-university hospital in Busan participated in the survey. The data were analyzed using t-test, ANOVA, Bonferroni test, Pearson correlation coefficients, and multiple linear regression analysis. RESULTS: The factors affecting self-care compliance were symptom experiences, disease status, age, and gender. These factors explained 21.6% of the variance in self-care compliance of patients with liver cirrhosis. CONCLUSION: The findings indicate that nursing interventions that prevent patients' symptoms are needed to promote self-care compliance in patients with liver cirrhosis. The patient should also be helped to recognize the need for self-care compliance from an early stage.


Assuntos
Humanos , Complacência (Medida de Distensibilidade) , Modelos Lineares , Cirrose Hepática , Fígado , Enfermagem , Autocuidado
2.
The Journal of Advanced Prosthodontics ; : 126-132, 2014.
Artigo em Inglês | WPRIM | ID: wpr-55978

RESUMO

PURPOSE: This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. MATERIALS AND METHODS: Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (alpha=0.05). RESULTS: The postload removal torque value was high in the following order with regard to magnitude: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). CONCLUSION: The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate.


Assuntos
Articulações , Torque
3.
The Journal of Korean Academy of Prosthodontics ; : 396-408, 2008.
Artigo em Coreano | WPRIM | ID: wpr-148378

RESUMO

STATEMENT OF PROBLEM: Within the elastic limit of the screw, the greater the preload, the tighter and more secure the screw joint. However, additional tensile forces can incur plastic deformation of the abutment screw when functional loads are superimposed on preload stresses, and they can elicit the loosening or fracture of the abutment screw. Therefore, it is necessary to find the optimum preload that will maximize fatigue life and simultaneously offer a reasonable degree of protection against loosening. Another critical factor in addition to the applied torque which can affect the amount of preload is the joint connection type between implant and abutment. PURPOSE: The purpose of this study was to evaluate the influence of tightening torque on the implant-abutment screw joint stability. MATERIAL AND METHODS: Respectively, three different amount of tightening torque (20, 30, and 40 Ncm) were applied to implant systems with three different joint connections, one external butt joint and two internal cones. The initial removal torque value and the postload (cyclic loading up to 100,000 cycles) removal torque value of the abutment screw were measured with digital torque gauge. Then rate of the initial and the postload removal torque loss were calculated for the comparison of the effect of tightening torques and joint connection types between implant and abutment on the joint stability. Results and CONCLUSION: 1. Increase in tightening torque value resulted in significant increase in initial and postload removal torque value in all implant systems (P .05), however GS II and US II systems exhibited significantly lower loss rates with 40 Ncm torque value than with 20 Ncm (P .05).


Assuntos
Fadiga , Articulações , Plásticos , Torque
4.
Experimental & Molecular Medicine ; : 1-11, 2002.
Artigo em Inglês | WPRIM | ID: wpr-228523

RESUMO

Until recently, vascular endothelial growth factor (VEGF) was the only growth factor proven to be specific and critical for blood vessel formation. Other long-known factors, such as the fibroblast growth factors (FGFs), platelet-derived growth factor, or transforming growth factor-beta, had profound effects in endothelial cells. But such factors were nonspecific, in that they could act on many other cells, and it seemed unlikely that these growth factors would be effective targets for treatment of endothelial cell diseases. A recently discovered endothelial cell specific growth factor, angiopoietin, has greatly contributed to our understanding of the development, physiology, and pathology of endothelial cells (Davis et al., 1996; Yancopoulos et al., 2000). The recent studies that identified and characterized the physiological and pathological roles of angiopoietin have allowed us to widen and deepen our knowledge about blood vessel formation and vascular endothelial function. Therefore, in this review, we describe the biomedical significance of these endothelial cell growth factors, the angiopoietins, in the vascular system under normal and pathological states.


Assuntos
Humanos , Processamento Alternativo , Indutores da Angiogênese/genética , Animais , Sobrevivência Celular , Fatores de Crescimento Endotelial/metabolismo , Endotélio Vascular/citologia , Hematopoese/fisiologia , Peptídeos e Proteínas de Sinalização Intercelular/metabolismo , Linfocinas/metabolismo , Glicoproteínas de Membrana/genética , Proteínas de Neoplasias/metabolismo , Neovascularização Patológica , Neovascularização Fisiológica , Transdução de Sinais/fisiologia , Sistema Urogenital/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA