Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
2.
Clinics ; 75: e1698, 2020. tab
Artigo em Inglês | LILACS | ID: biblio-1101087

RESUMO

OBJECTIVE: To report initial experience from the use of extracorporeal membrane oxygenation (ECMO) in patients who received lung transplantation. METHODS: Retrospective study of a single tertiary center in the Brazilian state of São Paulo, a national reference in lung transplantation, based on the prospective collection of data from electronic medical records. The period analyzed extended from January 2009 (beginning of the program) until December 2018. RESULTS: A total of 75 lung transplants were performed, with ECMO used in 8 (10.7%) cases. Of the patients, 4 (50%) were female. The mean age was 46.4±14.3 years. The causes of the end-stage lung disease that led to transplantation were pulmonary arterial hypertension in 3 (37.5%) patients, bronchiectasis in 2 (25%) patients, pulmonary fibrosis in 2 (25%) patients, and pulmonary emphysema in 1 (12.5%) patient. In our series, 7 (87.5%) cases were sequential bilateral transplantations. Prioritization was necessary in 4 (50%) patients, and in 1 patient, ECMO was used as a bridge to transplantation. The ECMO route was central in 4 (50%), peripheral venovenous in 2 (25%) and peripheral venoarterial in 2 (25%) patients. The mean length of the intensive care unit (ICU) stay was 14±7.5 days and of the hospital stay was 34.1±34.2 days. The mean ECMO duration was 9.3±6.6 days with a 50% decannulation rate. Three patients were discharged (37.5%). CONCLUSION: Lung transplantation requires complex treatment, and ECMO has allowed extending the indications for transplantation and provided adjuvant support in the clinical management of these patients.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Pneumopatias/terapia , Complicações Pós-Operatórias , Enfisema Pulmonar/terapia , Enfisema Pulmonar/epidemiologia , Fibrose Pulmonar/terapia , Fibrose Pulmonar/epidemiologia , Fatores de Tempo , Brasil/epidemiologia , Bronquiectasia/terapia , Bronquiectasia/epidemiologia , Estudos Prospectivos , Estudos Retrospectivos , Transplante de Pulmão/métodos , Resultado do Tratamento , Hipertensão Pulmonar Primária Familiar/terapia , Hipertensão Pulmonar Primária Familiar/epidemiologia , Unidades de Terapia Intensiva , Tempo de Internação , Pneumopatias/epidemiologia
4.
Einstein (Säo Paulo) ; 17(4): eAO4288, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1012012

RESUMO

ABSTRACT Objective: To assess the feasibility and impact of ex vivo lung perfusion with hyperoncotic solution (Steen Solution™) in the utilization of these organs in Brazil. Methods: In this prospective study, we subjected five lungs considered to be high risk for transplantation to 4 hours of ex vivo lung perfusion, with evaluation of oxygenation capacity. High-risk donor lungs were defined by specific criteria, including inflammatory infiltrates, pulmonary edema and partial pressure of arterial oxygen less than 300mmHg (inspired oxygen fraction of 100%). Results: During reperfusion, the mean partial pressure of arterial oxygen (inspired oxygen fraction of 100%) of the lungs did not change significantly (p=0.315). In the first hour, the mean partial pressure of arterial oxygen was 302.7mmHg (±127.66mmHg); in the second hour, 214.2mmHg (±94.12mmHg); in the third hour, 214.4mmHg (±99.70mmHg); and in the fourth hour, 217.7mmHg (±73.93mmHg). Plasma levels of lactate and glucose remained stable during perfusion, with no statistical difference between the moments studied (p=0.216). Conclusion: Ex vivo lung perfusion was reproduced in our center and ensured the preservation of lungs during the study period, which was 4 hours. The technique did not provide enough improvement for indicating organs for transplantation; therefore, it did not impact on use of these organs.


RESUMO Objetivo: Avaliar a exequibilidade e o impacto da perfusão pulmonar ex vivo com solução hiperoncótica (Steen Solution™) na taxa de utilização desses órgãos no Brasil. Métodos: Neste estudo prospectivo, submetemos cinco pulmões considerados de alto risco para o transplante a 4 horas de perfusão pulmonar ex vivo, com avaliação da capacidade de oxigenação pulmonar. Os pulmões de doadores de alto risco foram definidos por critérios específicos, incluindo infiltrado inflamatório, edema pulmonar e pressão parcial de oxigênio arterial inferior a 300mmHg (fração inspirada de oxigênio de 100%). Resultados: Durante a reperfusão, a pressão parcial de oxigênio arterial (fração inspirada de oxigênio de 100%) média dos pulmões não sofreu alteração significativa (p=0,315). Na primeira hora, a pressão parcial de oxigênio arterial média foi de 302,7mmHg (±127,66mmHg); na segunda, 214,2mmHg (±94,12mmHg); na terceira, 214,4mmHg (±99,70mmHg); e na quarta, 217,7mmHg (±73,93mmHg). Os níveis plasmáticos de lactato e glicose se mantiveram estáveis ao longo da perfusão, sem diferença estatística na comparação entre os momentos estudados (p=0,216). Conclusão: A perfusão pulmonar ex vivo foi reproduzida em nosso centro e garantiu a preservação de pulmões durante o período de estudo, que foi de 4 horas. A técnica não promoveu melhora suficiente para indicação do órgão para o transplante e, portanto, não impactou na taxa de utilização desses órgãos.


Assuntos
Humanos , Masculino , Feminino , Adulto , Preservação de Órgãos/métodos , Perfusão/métodos , Doadores de Tecidos , Transplante de Pulmão/métodos , Brasil , Complacência Pulmonar , Estudos Transversais , Estudos Prospectivos , Seleção do Doador , Pulmão/irrigação sanguínea , Pessoa de Meia-Idade
6.
J. bras. pneumol ; 42(2): 95-98, Mar.-Apr. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-780886

RESUMO

Objective: To evaluate the use of ex vivo lung perfusion (EVLP) clinically to prepare donor lungs for transplantation. Methods: A prospective study involving EVLP for the reconditioning of extended-criteria donor lungs, the criteria for which include aspects such as a PaO2/FiO2 ratio < 300 mmHg. Between February of 2013 and February of 2014, the lungs of five donors were submitted to EVLP for up to 4 h each. During EVLP, respiratory mechanics were continuously evaluated. Once every hour during the procedure, samples of the perfusate were collected and the function of the lungs was evaluated. Results: The mean PaO2 of the recovered lungs was 262.9 ± 119.7 mmHg at baseline, compared with 357.0 ± 108.5 mmHg after 3 h of EVLP. The mean oxygenation capacity of the lungs improved slightly over the first 3 h of EVLP-246.1 ± 35.1, 257.9 ± 48.9, and 288.8 ± 120.5 mmHg after 1, 2, and 3 h, respectively-without significant differences among the time points (p = 0.508). The mean static compliance was 63.0 ± 18.7 mmHg, 75.6 ± 25.4 mmHg, and 70.4 ± 28.0 mmHg after 1, 2, and 3 h, respectively, with a significant improvement from hour 1 to hour 2 (p = 0.029) but not from hour 2 to hour 3 (p = 0.059). Pulmonary vascular resistance remained stable during EVLP, with no differences among time points (p = 0.284). Conclusions: Although the lungs evaluated remained under physiological conditions, the EVLP protocol did not effectively improve lung function, thus precluding transplantation.


Objetivo: Avaliar o emprego da técnica de perfusão pulmonar ex vivo (PPEV) clinicamente com a finalidade de transplante. Métodos: Estudo prospectivo envolvendo o recondicionamento de pulmões limítrofes, definidos por critérios específicos, tais como relação PaO2/FiO2 < 300 mmHg, com um sistema de PPEV. Entre fevereiro de 2013 e fevereiro de 2014, os pulmões de cinco doadores foram submetidos à PPEV por até 4 h. Durante a PPEV, a mecânica pulmonar foi avaliada continuamente. Amostras do perfusato foram colhidas a cada hora, assim como foi realizada a avaliação funcional dos órgãos. Resultados: A média de PaO2 dos pulmões captados foi de 262,9 ± 119,7 mmHg, sendo que, ao final da terceira hora de perfusão, essa foi de 357,0 ±108,5 mmHg. A capacidade de oxigenação dos pulmões apresentou discreta melhora durante a PPEV nas primeiras 3 h (246,1 ± 35,1; 257,9 ± 48,9; e 288,8 ± 120,5 mmHg, respectivamente), sem diferenças significativas entre os momentos (p = 0,508). As médias de complacência estática foram de, respectivamente, 63.0 ± 18,7; 75,6 ± 25,4; e 70,4 ± 28,0 mmHg após 1, 2 e 3 h, com melhora significativa entre a hora 1 e 2 (p = 0,029), mas não entre a hora 2 e 3 (p = 0,059). A resistência vascular pulmonar permaneceu estável durante a PPEV, sem diferenças entre os momentos (p = 0,284). Conclusões: Os pulmões avaliados permaneceram em condições fisiológicas de preservação; no entanto, o protocolo não foi efetivo para promover a melhora na função pulmonar, inviabilizando o transplante.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Transplante de Pulmão/métodos , Pulmão/irrigação sanguínea , Preservação de Órgãos/métodos , Perfusão/métodos , Doadores de Tecidos , Análise de Variância , Brasil , Pulmão/patologia , Pulmão/fisiologia , Pressão Parcial , Estudos Prospectivos , Reprodutibilidade dos Testes , Mecânica Respiratória , Estatísticas não Paramétricas , Fatores de Tempo
7.
J. bras. pneumol ; 41(6): 547-553, Nov.-Dec. 2015. graf
Artigo em Português | LILACS | ID: lil-769780

RESUMO

ABSTRACT Lung transplantation is a well-established treatment for patients with advanced lung disease. The evaluation of a candidate for transplantation is a complex task and involves a multidisciplinary team that follows the patient beyond the postoperative period. Currently, the mean time on the waiting list for lung transplantation in the state of São Paulo, Brazil, is approximately 18 months. For Brazil as a whole, data from the Brazilian Organ Transplant Association show that, in 2014, there were 67 lung transplants and 204 patients on the waiting list for lung transplantation. Lung transplantation is most often indicated in cases of COPD, cystic fibrosis, interstitial lung disease, non-cystic fibrosis bronchiectasis, and pulmonary hypertension. This comprehensive review aimed to address the major aspects of lung transplantation: indications, contraindications, evaluation of transplant candidates, evaluation of donor candidates, management of transplant recipients, and major complications. To that end, we based our research on the International Society for Heart and Lung Transplantation guidelines and on the protocols used by our Lung Transplant Group in the city of São Paulo, Brazil.


RESUMO O transplante pulmonar é uma terapia bem estabelecida para pacientes com doença pulmonar avançada.A avaliação do candidato para o transplante é uma tarefa complexa e envolve uma equipe multidisciplinar que acompanha o paciente para além do período pós-operatório.O tempo médio atual em lista de espera para transplante pulmonar é de aproximadamente 18 meses no estado de São Paulo. Em 2014, dados da Associação Brasileira de Transplante de Órgãos mostram que 67 transplantes pulmonares foram realizados no Brasil e que 204 pacientes estavam na lista de espera para transplante pulmonar.O transplante pulmonar é principalmente indicado no tratamento de DPOC, fibrose cística, doença intersticial pulmonar, bronquiectasia não fibrocística e hipertensão pulmonar.Esta revisão abrangente teve como objetivos abordar os aspectos principais relacionados ao transplante pulmonar: indicações, contraindicações, avaliação do candidato ao transplante, avaliação do candidato doador, gestão do paciente transplantado e complicações maiores. Para atingirmos tais objetivos, utilizamos como base as diretrizes da Sociedade Internacional de Transplante de Coração e Pulmão e nos protocolos de nosso Grupo de Transplante Pulmonar localizado na cidade de São Paulo.


Assuntos
Humanos , Pneumopatias/cirurgia , Doadores de Tecidos , Pneumopatias/classificação , Pneumopatias , Transplante de Pulmão/estatística & dados numéricos , Fatores de Risco , Taxa de Sobrevida , Listas de Espera
9.
Einstein (Säo Paulo) ; 13(2): 297-304, Apr-Jun/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-751417

RESUMO

ABSTRACT Lung transplantation is a globally accepted treatment for some advanced lung diseases, giving the recipients longer survival and better quality of life. Since the first transplant successfully performed in 1983, more than 40 thousand transplants have been performed worldwide. Of these, about seven hundred were in Brazil. However, survival of the transplant is less than desired, with a high mortality rate related to primary graft dysfunction, infection, and chronic graft dysfunction, particularly in the form of bronchiolitis obliterans syndrome. New technologies have been developed to improve the various stages of lung transplant. To increase the supply of lungs, ex vivo lung reconditioning has been used in some countries, including Brazil. For advanced life support in the perioperative period, extracorporeal membrane oxygenation and hemodynamic support equipment have been used as a bridge to transplant in critically ill patients on the waiting list, and to keep patients alive until resolution of the primary dysfunction after graft transplant. There are patients requiring lung transplant in Brazil who do not even come to the point of being referred to a transplant center because there are only seven such centers active in the country. It is urgent to create new centers capable of performing lung transplantation to provide patients with some advanced forms of lung disease a chance to live longer and with better quality of life.


RESUMO O transplante pulmonar é um tratamento mundialmente aceito para alguma pneumopatias avançadas, conferindo aos receptores maior sobrevida e melhor qualidade de vida. Desde o primeiro transplante realizado com sucesso em 1983, mais de 40 mil transplantes foram feitos em todo mundo. Destes, cerca de 700 foram no Brasil. No entanto, a sobrevida do transplante é menor do que a desejada, com altos índices de mortalidade relacionados à disfunção primária do enxerto, infecções e disfunção crônica do enxerto, principalmente sob a forma da síndrome da bronquiolite obliterante. Novas tecnologias têm sido desenvolvidas para aprimoramento das diversas etapas do transplante pulmonar. Para aumentar a oferta de pulmões, o recondicionamento pulmonar ex vivo vem sendo utilizado em alguns países, inclusive no Brasil. Para suporte avançado de vida no período perioperatório, equipamentos de oxigenação extracorpórea e de suporte hemodinâmico vêm sendo utilizado como ponte para o transplante em pacientes gravemente doentes em lista de espera e para manter pacientes vivos até a resolução da disfunção primária do enxerto pós-transplante. Existe uma demanda reprimida de pacientes que necessitam de transplante pulmonar no Brasil e que nem sequer chegam a ser encaminhados a um centro transplantador, pois só existem sete deles ativos no país. É urgente a criação de novos centros capazes de realizar transplante pulmonar para oferecer a pacientes com algumas pneumopatias avançadas uma chance de viver mais e com melhor qualidade de vida.


Assuntos
Humanos , Transplante de Pulmão/estatística & dados numéricos , Doença Pulmonar Obstrutiva Crônica/cirurgia , Fibrose Pulmonar Idiopática/cirurgia , Brasil , Análise de Sobrevida , Causas de Morte , Listas de Espera , Fatores Etários , Transplante de Pulmão/métodos , Transplante de Pulmão/mortalidade , Medição de Risco , Seleção do Doador , Período Perioperatório , Contraindicações , Rejeição de Enxerto/prevenção & controle
10.
Acta cir. bras ; 30(5): 359-365, 05/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-747026

RESUMO

PURPOSE: To evaluate a new perfusate solution to be used for ex vivo lung perfusion. METHODS: Randomized experimental study using lungs from rejected brain-dead donors harvested and submitted to 1 hour of ex vivo lung perfusion (EVLP) using mainstream solution or the alternative. RESULTS: From 16 lungs blocs tested, we found no difference on weight after EVLP: Steen group (SG) = 1,097±526g; Alternative Perfusion Solution (APS) = 743±248g, p=0.163. Edema formation, assessed by Wet/dry weigh ratio, was statistically higher on the Alternative Perfusion Solution group (APS = 3.63 ± 1.26; SG = 2.06 ± 0.28; p = 0.009). No difference on PaO2 after EVLP (SG = 498±37.53mmHg; APS = 521±55.43mmHg, p=0.348, nor on histological analyses: pulmonary injury score: SG = 4.38±1.51; APS = 4.50±1.77, p=0.881; apoptotic cells count after perfusion: SG = 2.4 ± 2.0 cells/mm2; APS = 4.8 ± 6.9 cells/mm2; p = 0.361). CONCLUSION: The ex vivo lung perfusion using the alternative perfusion solution showed no functional or histological differences, except for a higher edema formation, from the EVLP using Steen Solution(r) on lungs from rejected brain-dead donors. .


Assuntos
Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Transplante de Pulmão/métodos , Pulmão/irrigação sanguínea , Soluções para Preservação de Órgãos , Preservação de Órgãos/métodos , Perfusão/métodos , Circulação Extracorpórea/métodos , Traumatismo por Reperfusão , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Fatores de Tempo , Doadores de Tecidos , Coleta de Tecidos e Órgãos/métodos
16.
J. bras. pneumol ; 36(2): 265-269, mar.-abr. 2010. ilus
Artigo em Português | LILACS | ID: lil-546384

RESUMO

Apesar das medidas de prevenção, a hiperinsuflação pulmonar é uma complicação relativamente comum após transplantes unilaterais por enfisema. Quando progressiva, pode comprimir o pulmão transplantado, gerando desvio mediastinal e insuficiência respiratória. Além de estratégias terapêuticas como a ventilação independente, o tratamento consiste na redução volumétrica do pulmão nativo, seja por meio de cirurgia redutora, seja por lobectomia. São relatados dois casos de hiperinsuflação do pulmão nativo após transplante pulmonar, tratados com redução volumétrica do pulmão por meio de lobectomia ou cirurgia redutora.


Despite preventive measures, lung hyperinflation is a relatively common complication following single lung transplantation to treat pulmonary emphysema. The progressive compression of the graft can cause mediastinal shift and respiratory failure. In addition to therapeutic strategies such as independent ventilation, the treatment consists of the reduction of native lung volume by means of lobectomy or lung volume reduction surgery. We report two cases of native lung hyperinflation after single lung transplantation. Both cases were treated by means of lobectomy or lung volume reduction surgery.


Assuntos
Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Transplante de Pulmão/efeitos adversos , Complicações Pós-Operatórias/etiologia , Enfisema Pulmonar/cirurgia , Evolução Fatal , Medidas de Volume Pulmonar , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/cirurgia
18.
J. bras. pneumol ; 35(11): 1107-1111, nov. 2009. ilus, tab
Artigo em Português | LILACS | ID: lil-533289

RESUMO

Nos últimos 20 anos, o transplante pulmonar tornou-se o tratamento padrão para algumas pneumopatias graves em estágio terminal. Menos de 20 por cento dos pulmões doados para transplante são realmente utilizados. Essa desproporção entre o crescente número de candidatos ao transplante pulmonar e o reduzido número de doadores resulta em aumento da mortalidade nas filas de espera. Estratégias, como o uso de órgãos de doadores marginais, não se mostraram efetivas em aumentar o número de transplantes. Em 2000, na Suécia, foi desenvolvido um método novo para recondicionar pulmões humanos rejeitados para transplante. Descrevemos nossa experiência inicial com a perfusão pulmonar ex vivo.


In the last 20 years, lung transplantation has become the standard treatment for patients with end-stage lung disease. However, less than 20 percent of the donor lungs available for transplant are actually usable. This disparity between the growing number of recipients and the small number of donors has resulted in increased mortality among lung transplant candidates on waiting lists. Strategies such as the utilization of organs from marginal donors have proven ineffective in increasing the number of transplants. In 2000, a new method for reconditioning human lungs that had been previously rejected for transplantation was developed in Sweden. We describe our initial experience with ex vivo lung perfusion.


Assuntos
Idoso , Humanos , Pessoa de Meia-Idade , Pulmão , Transplante de Pulmão , Preservação de Órgãos/métodos , Perfusão/métodos , Brasil , Seleção do Doador , Perfusão/instrumentação
19.
Clinics ; 64(6): 519-525, June 2009. graf, tab
Artigo em Inglês | LILACS | ID: lil-517922

RESUMO

OBJECTIVE: The purpose of this study was to compare spirometry data between patients who underwent single-lung or double-lung transplantation the first year after transplantation. INTRODUCTION: Lung transplantation, which was initially described as an experimental method in 1963, has become a therapeutic option for patients with advanced pulmonary diseases due to improvements in organ conservation, surgical technique, immunosuppressive therapy and treatment of post-operative infections. METHODS: We retrospectively reviewed the records of the 39 patients who received lung transplantation in our institution between August 2003 and August 2006. Twenty-nine patients survived one year post-transplantation, and all of them were followed. RESULTS: The increase in lung function in the double-lung transplant group was more substantial than that of the single-lung transplant group, exhibiting a statistical difference from the 1st month in both the forced expiratory volume in one second (FEV1) and the forced vital capacity (FVC) in comparison to the pre-transplant values (p <0.05). Comparison between double-lung transplant and single lung-transplant groups of emphysema patients demonstrated a significant difference in lung function beginning in the 3rd month after transplantation. DISCUSSION: The analyses of the whole group of transplant recipients and the sub-group of emphysema patients suggest the superiority of bilateral transplant over the unilateral alternative. Although the pre-transplant values of lung function were worse in the double-lung group, this difference was no longer significant in the subsequent months after surgery. CONCLUSION: Although both groups demonstrated functional improvement after transplantation, there was a clear tendency to greater improvement in FVC and FEV1 in the bilateral transplant group. Among our subjects, double-lung transplantation improved lung function.


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Transplante de Pulmão/fisiologia , Espirometria , Enfisema/patologia , Seguimentos , Transplante de Pulmão/patologia , Testes de Função Respiratória , Estudos Retrospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA