Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Dent. press endod ; 9(1): 26-30, jan.-mar. 2019. tab
Artigo em Português | LILACS, BBO | ID: biblio-1000064

RESUMO

Objetivo: o objetivo do presente estudo foi comparar a resistência à fratura de quatro tipos de pinos intrarradiculares pré-fabricados: fibra de vidro, fibra de vidro customizado com resina composta, fibra de carbono e fibra de carbono customizado com resina, em dentes bovinos. Métodos: foram utilizados 60 dentes bovinos unirradiculares, que receberam tratamento endodôntico e foram divididos nos seguintes grupos: FV = pino de fibra de vidro; FVP = pino de fibra de vidro customizado; FC = pino de fibra de carbono; FCP = pino de fibra de carbono customizado; e Controle = restauração coronária com resina composta. Os dentes foram inseridos em blocos de resina acrílica, a 2 mm da junção amelocementária, simulando a interface dente-osso. Os espécimes foram submetidos ao teste de resistência à fratura em máquina de ensaio universal, sob uma carga de 0,5mm/min, até a fratura do corpo de prova. Os valores obtidos foram submetidos ao teste ANOVA, com pós-teste de Tukey. Foi realizada, também, uma análise dos padrões de fratura, por meio do teste Kruskal- -Wallis. Resultados: o grupo FCP mostrou os maiores valores de resistência à fratura, seguido pelos grupos FV, FVP e FC. O grupo controle mostrou menor resistência do que os demais, que receberam pinos intrarradiculares. Os pinos de FVP apresentaram o maior número de fraturas reparáveis, em contraste ao controle, no qual houve o maior número de fraturas desfavoráveis. Conclusão: o uso de pinos customizados reduziu a incidência de fraturas catastróficas. A ausência de pino intrarradicular ocasionou a maior incidência de fraturas irreparáveis. (AU)


Objective: The aim of this study was to compare the fracture resistance of four types of prefabricated intraradicular posts - glass fiber, glass fiber customized by composite resin, carbon fiber, and customized carbon fiber - on bovine teeth. Methods: Sixty bovine teeth were submitted to endodontic treatment and divided into the following groups: GF - glass fiber post; CGF - customized glass fiber post; CF - carbon fiber post; CCF - customized carbon fiber post; control - composite resin restoration. The teeth were embedded in acrylic resin blocks at 2 mm from the cement-enamel junction, simulating the teeth-bone interface. The specimens were submitted to a fracture resistance test in a universal test machine under a 0.5 mm/min load until the fracture of the specimen. The values obtained were submitted to ANOVA and Tukey tests. The analysis of the fracture patterns was performed by the Kruskal-Wallis test. Results: The CCF group presented the highest values of fracture resistance, followed by GF, CGF, and CF posts. The control group offered less resistance than the other groups that received intraradicular posts. The CGF presented the highest number of favorable fractures, in contrast to the control group, which presented the highest number of unfavorable fractures. Conclusion: The use of customized posts reduced the incidence of catastrophic fractures. The lack of intracanal posts led to a higher incidence of irreparable fractures (AU).


Assuntos
Fraturas dos Dentes , Pinos Dentários , Endodontia , Técnica para Retentor Intrarradicular , Restauração Dentária Permanente
2.
J. appl. oral sci ; 23(2): 164-168, Mar-Apr/2015. tab, graf
Artigo em Inglês | LILACS, BBO | ID: lil-746534

RESUMO

The search for new instruments to promote an appropriate cervical preparation has led to the development of new rotary instruments such as TripleGates. However, to the best of the authors' knowledge, there is no study evaluating TripleGates effect on the “risk zone” of mandibular molars. Objectives : The aim of this study was to evaluate the effects of a crown-down sequence of Gates-Glidden and TripleGates burs on the remaining cervical dentin thickness and the total amount of dentin removed from the root canals during the instrumentation by using cone beam computed tomography. The number of separated instruments was also evaluated. Material and Methods : Mesial roots of 40 mandibular first molars were divided into 2 equal groups: crown-down sequence of Gates-Glidden (#3, #2, #1) and TripleGates burs. Cervical dentin thickness and canal area were measured before and after instrumentation by using cone beam computed tomography and image analysis software. Student’s t-test was used to determine significant differences at p<0.05. Results : No significant differences (p>0.05) were observed between the instruments, regarding the root canal area and dentin wall thickness. Conclusion : Both tested instruments used for cervical preparation were safe to be used in the mesial root canal of mandibular molars. .


Assuntos
Humanos , Masculino , Adulto , Acidentes de Trabalho , Hidróxido de Amônia/toxicidade , Queimaduras por Inalação/complicações , Lesão Pulmonar/etiologia , Lesão Pulmonar/cirurgia , Agricultura , Queimaduras por Inalação/etiologia , Queimaduras por Inalação/fisiopatologia , Progressão da Doença , Explosões , Seguimentos , Escala de Gravidade do Ferimento , Testemunhas de Jeová , Lesão Pulmonar/fisiopatologia , Transplante de Pulmão/métodos , Qualidade de Vida , Doenças Raras , Medição de Risco , Fatores de Tempo , Resultado do Tratamento
3.
Braz. j. oral sci ; 13(4): 246-250, Oct-Dec/2014. tab, graf
Artigo em Inglês | LILACS, BBO | ID: lil-732335

RESUMO

Aim: To evaluate the foraminal transportation during foraminal enlargement after manual instrumentation with stainless steel files, preparation with the Mtwo system and Reciproc R25 file. Methods: Thirty roots were selected, divided in three groups and prepared in accordance with the different instrumentation systems: Hand Files (HF); Mtwo system (MS); and Reciproc system (RS). All groups were prepared with the instrumentation level 1 mm beyond the apex. Photomicrographs were performed using scanning electron microscopy, to record the foraminal anatomy before and after instrumentation. Data were analyzed using ANOVA followed by Tukey's test with a significance level of 5%. Results: The group instrumented with hand files showed higher foraminal transportation when compared to the Mtwo and Reciproc groups (p<0.05). Reciproc group showed lower transportation when compared to the Mtwo group (p<0.05). Conclusions: The stainless steel files caused significant foraminal transportation, while Reciproc system showed safe apical preparation, with little transportation.


Assuntos
Endodontia/instrumentação , Anatomia
4.
Braz. dent. j ; 24(2): 117-120, Mar-Apr/2013. graf
Artigo em Inglês | LILACS | ID: lil-675666

RESUMO

The aim of this study was to assess cyclic fatigue resistance in rotary nickel-titanium instruments after simulated clinical use in curved root canals (40-degree, 5-mm radius curve). Thirty-six RaCe rotary NiTi files, size #5, taper 0.04, were divided into 3 groups: Groups A, B and C with one, three and five cycles of use, respectively. Time to failure was recorded with a stopwatch in seconds and subsequently converted to number of cycles to fracture. The data were analyzed statistically by ANOVA and Tukey's test (α=0.05). Five sets of clinically used files (group C) reached significantly lower cycle-numbers before fracture (mean=197.5 cycles) when compared with one set of clinically used files (mean=309.2) and three sets (mean=287.5). Results showed that the number of simulated clinical uses of RaCe instruments for shaping curved canals affects adversely the fatigue resistance of these instruments after five uses.


Resumo O objetivo deste estudo foi avaliar a resistência à fadiga cíclica de instrumentos rotatórios de níquel-titânio após simulação de uso clinico em canais curvos (curvatura de 40° e raio de 5 mm). Trinta e seis instrumentos, calibre n° 25 conicidade 0,04, foram divididos em três grupos: o Grupo A com um ciclo de uso; Grupo B, três ciclos de uso e grupo C, cinco ciclos de uso. Um cronômetro digital aferiu em segundos o tempo até a fratura do instrumento que, posteriormente, foi convertido em número de ciclos para fratura. Os dados foram analisados por ANOVA e teste de Tukey (p<0,05). O grupo que utilizou o instrumento por cinco ciclos (grupo C) atingiu significativamente menores números de ciclos antes da fratura (média = 197,5 ciclos) quando comparado com os instrumentos utilizados em um ciclo (média = 309,2) e três ciclos (média = 287,5). Os resultados mostraram que o número de uso de instrumentos RaCe para modelar canais curvos afeta negativamente a resistência à fadiga cíclica dos instrumentos após cinco usos. .


Assuntos
Humanos , Ligas Dentárias/química , Cavidade Pulpar/anatomia & histologia , Níquel/química , Preparo de Canal Radicular/instrumentação , Titânio/química , Desenho de Equipamento , Falha de Equipamento , Modelos Anatômicos , Rotação , Estresse Mecânico , Fatores de Tempo
5.
Dental press j. orthod. (Impr.) ; 18(1): 86-93, Jan.-Feb. 2013. ilus, tab
Artigo em Inglês | LILACS | ID: lil-674269

RESUMO

OBJECTIVE: To evaluate the in vitro ionic degradation and slot base corrosion of metallic brackets subjected to brushing with dentifrices, through analysis of chemical composition by Energy Dispersive Spectroscopy (EDS) and qualitative analysis by Scanning Electron Microscopy (SEM). METHODS: Thirty eight brackets were selected and randomly divided into four experimental groups (n = 7). Two groups (n = 5) worked as positive and negative controls. Simulated orthodontic braces were assembled using 0.019 x 0.025-in stainless steel wires and elastomeric rings. The groups were divided according to surface treatment: G1 (Máxima Proteção Anticáries®); G2 (Total 12®); G3 (Sensitive®); G4 (Branqueador®); Positive control (artificial saliva) and Negative control (no treatment). Twenty eight brushing cycles were performed and evaluations were made before (T0) and after (T1) experiment. RESULTS: The Wilcoxon test showed no difference in ionic concentrations of titanium (Ti), chromium (Cr), iron (Fe) and nickel (Ni) between groups. G2 presented significant reduction (p < 0.05) in the concentration of aluminium ion (Al). Groups G3 and G4 presented significant increase (p < 0.05) in the concentration of aluminium ion. The SEM analysis showed increased characteristics indicative of corrosion on groups G2, G3 and G4. CONCLUSION: The EDS analysis revealed that control groups and G1 did not suffer alterations on the chemical composition. G2 presented degradation in the amount of Al ion. G3 and G4 suffered increase in the concentration of Al. The immersion in artificial saliva and the dentifrice Máxima Proteção Anticáries® did not alter the surface polishing. The dentifrices Total 12®, Sensitive® and Branqueador® altered the surface polishing.


OBJETIVO: avaliar in vitro a degradação iônica e corrosão do fundo do slot de braquetes metálicos submetidos à escovação com dentifrícios, realizando análises da composição química por Espectroscopia de Energia Dispersiva (EDS) e qualitativa por Microscopia Eletrônica de Varredura (MEV). MÉTODOS: foram selecionados 38 braquetes divididos aleatoriamente em quatro grupos experimentais (n = 7). Dois grupos (n = 5) funcionaram como controles positivo e negativo. Aparelhos ortodônticos simulados foram confeccionados com fios de aço inoxidável 0,019" x 0,025" e anéis elastoméricos. Os grupos foram divididos de acordo com o tratamento de superfície: G1 (Máxima Proteção Anticáries®); G2 (Total 12®); G3 (Sensitive®); G4 (Branqueador®); Controle Positivo (saliva artificial) e Controle Negativo (sem tratamento). Foram realizados 28 ciclos de escovação e avaliações antes (T0) e após (T1) o experimento. RESULTADOS: o teste de Wilcoxon indicou não existir diferença nas concentrações iônicas de titânio (Ti), cromo (Cr), ferro (Fe) e níquel (Ni) entre os grupos. O grupo G2 apresentou redução significativa (p < 0,05) na concentração do íon alumínio (Al) e os grupos G3 e G4 apresentaram aumento significativo (p < 0,05) nas concentrações do íon alumínio. A análise em MEV mostrou aumento nas características indicativas de corrosão dos grupos G2, G3 e G4. CONCLUSÃO: a análise por EDS revelou que os grupos controle e G1 não sofreram alterações na composição química. O grupo G2 apresentou degradação na quantidade de íons Al, e G3 e G4 sofreram aumento na concentração de Al. A imersão em saliva artificial e o dentifrício Máxima Proteção Anticáries® não alteraram o polimento de superfície. Os dentifrícios Total 12®, Sensitive® e Branqueador® alteraram o polimento de superfície.


Assuntos
Corrosão , Dentifrícios/química , Metais/química , Braquetes Ortodônticos , Estresse Mecânico , Íons/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Saliva Artificial , Espectrometria por Raios X , Propriedades de Superfície
6.
Rev. odontol. UNESP (Online) ; 38(1): 37-43, jan.-fev. 2009. ilus, tab
Artigo em Português | LILACS, BBO | ID: lil-621787

RESUMO

O objetivo deste trabalho é avaliar a eficiência de remoção do hidróxido de cálcio [Ca (OH)2] do interior do canal radicular, valendo-se de diferentes métodos. Vinte e seis incisivos inferiores foram preparados com a técnica escalonada regressiva e preenchidos com Ca(OH)2associado a soro fisiológico. As amostras foram armazenadas a 37 °C, em 100% de umidade relativa, por sete dias e foram divididas em dois grupos, de acordo com a técnica de remoção da medicação intracanal. No Grupo1 (G1): irrigação com 5 mL de hipoclorito de sódio 1%; limagem com instrumento memória por 1 minuto; irrigação com 5 mL de hipoclorito de sódio 1%; patência por 10 segundos; irrigação final com 10 mL de EDTA-T 17%. No Grupo 2 (G2), procederam-se as mesmas etapas do G1, acrescendo-se o uso do ultrassom por 1 minuto com lima #15. As amostras foram avaliadas qualitativamente em microscópio eletrônico de varredura, por meio de imagens de diferentes áreas do terço apical. De acordo com o teste de Mann-Whitney, com nível de significância de 5%, G1 não diferiu estatisticamente do G2. O teste de Friedman indicou diferenças estatisticamente significativas entre as áreas do terço apical para os dois grupos, sugerindo que à medida que se aproxima da área mais apical, menos eficaz é a remoção do hidróxido de cálcio. Os resultados mostraram que nenhuma técnica removeu completamenteo Ca (OH)2 do canal radicular.


The purpose of this study was to evaluate the efficiency of different methods of removal of calcium hydroxide [Ca (OH)2]. Twenty six inferior incisors had been prepared using the regressive technique and filled with Ca (OH)2. The samples had been stored to 37 °C in 100% of relative humidity per 7 days. The teeth had been divided in two groups in accordance with the technique of removal of the intracanal medication. In the Grupo1 (G1) ? 5 mL of 1% sodium hypochlorite (NaOCl); instrumented for 1 minute; 5 mL of 1% NaOCl; patency per 10 seconds; 10 mL of EDTA - T 17%. Group 2 (G2) follows the same stages of the G1, increasing the use of the ultrasonic for 1 minute. The samples had been evaluated qualitatively in electron microscope, through images of different areas of apical third. In accordance with the test of Mann-Whitney, with level of significance of 5%, G1 does not differ from G2. The test of Friedman indicates significant differences between the areas of apical third for the two groups. Results showed that no technique removed all Ca (OH)2.


Assuntos
Irrigantes do Canal Radicular , Hipoclorito de Sódio , Ultrassom , Hidróxido de Cálcio , Microscopia Eletrônica de Varredura , Cavidade Pulpar , Estatísticas não Paramétricas
7.
Rev. odontol. UNESP (Online) ; 38(1): 31-35, jan.-fev. 2009. ilus
Artigo em Português | LILACS, BBO | ID: lil-621788

RESUMO

A icterícia neonatal severa é a principal causa da paralisia cerebral do tipo atetoide e pode ser decorrente da deficiência de uma enzima chamada Glicose-6-Fosfato-Desidrogenase (G6PD). Esta pesquisa tem como objetivo avaliar laboratorialmente a deficiência de G6PD em pacientes com paralisia cerebral e a história clínica de icterícia ou kernicterus, a fim de verificar uma possível relação entre a deficiência dessa enzima e a incidência de paralisia cerebral. Foram incluídos no estudo, pacientes com paralisia cerebral e história clínica de icterícia ou kernicterus. Após o aceite, os pacientes foram submetidos a exames de sangue para avaliar a deficiência de G6PD. A análise das amostras foi realizada pelo método enzimático, de acordo com o princípio colorimétrico, que consiste na mistura por inversão das amostras e reagentes (glicose 5%, nitritode sódio 1,25% e azul de metileno), ficando em banho-maria por três horas a 37 °C. Em seguida, retirou-se 0,1 mL do sedimento, acrescentaram-se 10 mL de água destilada e fez-se a leitura. Dos20 pacientes pré-selecionados, quatro (20%) não participaram, pois estavam doentes no momento da coleta. Dos 16 pacientes que foram submetidos ao exame de sangue, quatro (25%) tiveram resultadopositivo para deficiência de G6PD. Baseado nos resultados desta pesquisa, pode-se concluir que a deficiência de G6PD é um fator predisponente à paralisia cerebral e o cirurgião-dentista deve terprecaução, principalmente quanto à prescrição de medicamentos de risco para o desenvolvimento de anemia severa em pacientes com deficiência de G6PD.


Neo-birth severe jaundice is the main cause for cerebral palsy of the athetoid type and may be due to the deficiency of an enzyme called Glicosis-6-Phosphate-Dehydrogenase (G6PD). This paper aimed to evaluate, in laboratory, the deficiency of G6PD in patients with cerebral palsy in order to enable a better action by the surgeon-dentist, besides tutoring and furnishing to the patient?s companion a diagnosis of G6PD deficiency, a list of medicines which may be avoided due to anemia risk. It was included, in this paper with cerebral palsy and clinical record of jaundice or kernicterus. After agreement, patients underwent blood examination in order to evaluate G6PD deficiency. Sample analysis was performed by the enzymatic, according to the calorimetric principlewhich consists in the mixture by inversion of samples and reagents (glucose 5%, sodium nitrite 1.25%) e methylene blue in double boiling for three hours at 37 °C and, right after, it was taken 0.1 mL of the sediment, added 10 mL of distilled water and the records were measured. Fromthe 20 patients who have been pre-selected, 4 (25%) did not participate for they were sick at the moment of collection; and from the 16 patients who underwent blood examination, 4 (25%) were positive for G6PD deficiency. Based on results of this research it may be concluded that G6PD deficiency is a factor that prepares to cerebral palsy and the surgeon-dentist shall be precautious when prescribe medicines with risk to development anemia in patient with cerebral palsy.


Assuntos
Paralisia Cerebral , Assistência Odontológica para a Pessoa com Deficiência , Enzimas , Icterícia Neonatal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA