Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Braz. dent. j ; 29(6): 583-591, Nov.-Dec. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-974192

RESUMO

Abstract The purpose of this study was to evaluate the preservation of alveolar dimensions in human fresh extraction sockets filled with a composite bovine bone graft by means of design of single-blind randomized clinical trial. Forty participants had monoradicular teeth extracted (one teeth in each participant), and after were randomly divided into 2 groups: individuals whose fresh sockets were filled with the composite heterologous bone graft (Biomaterial Group), or with blood clot (Control Group). After extraction, the fresh sockets were measured at their greatest mesiodistal (MD) and bucco-lingual/palatal (BL/P) distance. Primary closure of the soft tissue was performed with a fibro-mucosal plug. After 120 post-operative days, the re-entry procedure was performed and the largest MD and BL/P measurements were again obtained to calculate the remodeling of the alveolar bone measured in percentage. In the biomaterial group, a percentage reduction of 1.62% and 3.29% in the MD and BL/P dimensions was observed 120 days after the extractions, whereas a reduction of 4.97% and 7.18% in the MD and BL/P dimensions occurred in the control group. There was a statistically significant difference (p<0.05) between the two groups for the bucco-palatal and mesiodistal measurements in the maxilla. In view of the results obtained, it can be concluded that composite bovine bone graft limited but did not impede alveolar bone remodeling.


Resumo O objetivo deste estudo foi avaliar em humanos a manutenção do volume em alvéolos frescos preenchidos por osso integral de origem bovina por meio de um estudo clínico randomizado com monocegamento. Quarenta dentes uni radiculares foram extraídos em 40 pacientes (um dente em cada participante), e apos estes pacientes foram divididos aleatoriamente em 2 grupos: indivíduos que tiveram o alvéolo fresco preenchido por osso integral de origem bovina (Grupo Biomaterial) ou por coagulo sanguíneo (Grupo Controle). Apos a exodontia os alvéolos foram medidos em suas maiores distancias mesio-distal (MD) e vestíbulo lingual/palatina (VL/P) por meio de compasso de ponta seca. O fechamento primário dos alvéolos foi realizado com um tampão fibromucoso. Apos 120 dias pós-operatórios durante o procedimento de reabertura foram obtidas novamente as maiores medidas MD e VL/P para calcular em porcentagem o nível de remodelação do osso alveolar. No grupo biomaterial observou-se uma redução em porcentagem de 1,62% e 3,29% nas medidas MD e VL/P 120 dias apos as extrações, enquanto no grupo controle houve uma redução de 4,97% e 7,18% nas medidas MD e VL/P no mesmo período. Houve diferença estatisticamente significante (p<0,05) entre os dois grupos para as medidas vestíbulo/palatina e mesiodistal na maxila. Diante dos resultados obtidos conclui-se que o osso integral de origem bovina limitou, mas não impediu a remodelação óssea alveolar.


Assuntos
Humanos , Animais , Adolescente , Adulto , Pessoa de Meia-Idade , Perda do Osso Alveolar/prevenção & controle , Remodelação Óssea/fisiologia , Substitutos Ósseos/farmacologia , Extração Dentária , Cicatrização/fisiologia , Bovinos , Método Simples-Cego , Resultado do Tratamento , Alvéolo Dental
2.
ImplantNewsPerio ; 1(2): 258-268, fev.-mar. 2016. ilus, tab
Artigo em Português | LILACS, BBO | ID: biblio-847353

RESUMO

Objetivo: avaliar o índice de sobrevida de implantes osseointegráveis instalados em maxilas submetidas previamente ao enxerto sinusal e à remodelação óssea, ocorrida após o período de reparo do enxerto. Material e métodos: foram selecionados 12 pacientes que receberam implantes osseointegráveis em maxilares submetidos à elevação de membrana sinusal, seguido da aplicação de substituto ósseo heterógeno composto de origem bovina (GenMix, Baumer, Mogi Mirim, Brasil) ou do biomaterial sintético à base de fosfato ß-tricálcio (Cerasorb, Curasan AG, Kleinostheim, Alemanha). Foi avaliado o índice de sobrevida dos implantes e o nível da remodelação óssea vertical. Foram digitalizadas radiografi as panorâmicas, e mensuradas a extensão linear vertical do remanescente ósseo (T0) e a extensão linear vertical, após o período de incorporação do enxerto ósseo (T1) e após período de osseointegração do implante (T2). Resultados: o índice de sobrevida dos implantes no período de 60 a 84 meses foi de 90% nos seios maxilares, preenchidos por substituto ósseo heterógeno composto de origem bovina. Nos seios preenchidos por biomaterial sintético à base de fosfato ß-tricálcio, o índice de sobrevida dos implantes no período de 60 a 76 meses foi de 88,89%. Foram perdidos dois implantes, um em seio preenchido por osso heterógeno composto e o outro em seio preenchido por fosfato ß-tricálcio. O nível de remodelação óssea foi de 3,29 mm e 1,6 mm, respectivamente, para o osso heterógeno composto de origem bovina, e para o biomaterial sintético a base de fosfato ß-tricálcio. Não houve diferenças estatisticamente signifi cativas entre o nível de remodelação dos dois biomateriais. Conclusão: diante dos resultados obtidos, concluiu-se que ambos os materiais mostraram-se adequados para ossificação intrasinusal, por meio da técnica de elevação da membrana sinusal.


Objective: to evaluate the survival rate of osseointegrated implants placed on maxillary arches submitted to sinus graftings and also the bone remodeling after the graft repair period. Material and methods: twelve patients were selected to receive maxillary osseointegrated implants after the use of a bovine composite bone (GenMix, Baumer, Mogi Mirim, Brazil) or a synthetic ß-tricalcium phosphate biomaterial (Cerasorb, Curasan AG, Kleinostheim, Germany). The implant survival and bone remodeling rates were evaluated on digitized panoramic radiographs being measured the linear extension of the remaining bone (T0), the vertical linear extension after graft incorporation (T1), and after the implant osseointegration period (T2). Results: the implant survival rates were 90% after 60-84 months (bovine composite bone) and 88.89% after 60-76 months (ß-tricalcium phosphate) of follow-ups. Two implants were lost (1 for each group). The bone remodeling values were 3.29 mm and 1.6 mm for the composite bovine bone and the ß-tricalcium phosphate materials. No statistically signifi cant differences were observed between these materials regarding the bone remodeling process. Conclusion: within the results of this study, it can be concluded that both materials are adequate for intrasinus ossification in the sinus lifting membrane technique.


Assuntos
Humanos , Materiais Biocompatíveis , Remodelação Óssea , Implantação Dentária Endóssea , Implantes Dentários , Estudos Retrospectivos , Levantamento do Assoalho do Seio Maxilar
3.
ImplantNews ; 12(2): 181-190, 2015. ilus
Artigo em Português | LILACS | ID: lil-757856

RESUMO

As fenestrações das paredes alveolares são relativamente comuns durante o procedimento cirúrgico para instalação de implantes. O objetivo do presente trabalho foi relatar um caso clínico de reconstrução de fenestração peri-implantar imediatamente após a instalação de implante osseointegrável, através de enxerto ósseo autógeno em bloco obtido do ramo mandibular. Paciente do sexo masculino procurou o Departamento de Cirurgia e Clínica Integrada para trocar sua prótese parcial removível classe IV de Kennedy por prótese parcial fixa implantossuportada. Foram instalados dois implantes nos espaços protéticos correspondente aos dentes 12 e 21. Houve uma fenestração peri-implantar da parede vestibular durante a instalação do implante correspondente ao dente 12, que foi reconstruídapor meio de enxerto autógeno em bloco obtido do ramo mandibular e fixado por meio de parafuso bicortical. Após seis meses de concomitante período de incorporação do enxerto ósseo autógeno e osseointegração, iniciou-se o processamento para confecção da prótese parcial fixa implantossuportada. Diante da reabilitação protética alcançada, concluiu-se que o enxerto ósseo autógeno obtido da área doadora ramo mandibular constitui uma alternativa segura e eficaz para reconstrução de defeitos peri-implantares em forma de fenestração óssea...


Alveolar wall fenestrations are common during implant placement. The aim of this paper is to report a case where a peri-implant bone fenestration was reconstructed immediately after implant placement by an autogenous mandibular bone block. A male patient was referred to the Department of Surgical and Integrated Clinics to substitute his Kennedy´s Class IV removable partial denture for an implantsupported fixed prosthesis. A peri-implant bone fenestration at the buccal wall was seen at the region of 12, being reconstructed by a mandibular bone block secured by a bicortical screw. Six months later the surgical procedures, an implant-supported complete fixed partial prosthesis was developed. The autogenous bone block harvested from the mandibular ramus was a safe alternative to reconstruct the peri-implant bone defect such as fenestration types...


Assuntos
Humanos , Masculino , Adulto , Transplante Ósseo , Implantes Dentários , Reconstrução Mandibular , Reabilitação Bucal
4.
ImplantNews ; 10(4): 441-446, 2013. ilus
Artigo em Português | LILACS, BBO | ID: lil-694445

RESUMO

Este relato de caso mostra como o prognóstico da atrofia mandibular severa pode ser melhorado pelo uso dos implantes dentários curtos. Um paciente leucoderma do sexo masculino, 54 anos de idade, recebeu quatro implantes na região mandibular anterior. A prótese definitiva foi entregue quatro meses depois. Após oito anos de acompanhamento, não foram registradas queixas ou perda de osseointegração. Implantes dentários curtos com próteses fixas implantossuportadas podem ser um tratamento bem-sucedido na arcada mandibular atrófica.


This case report shows how the prognosis of severe mandibular atrophy can be improved with the use of short dental implants. A Caucasian 54 years-old male patient received four dental implants in the anterior mandibular region. Four months later, the definitive prosthesis was delivered. At the 8-year follow-up period, no complaints or loss of integration were reported. Short dental implants with complete, fixed definitive prosthesis can be a successful treatment in the mandibular arch.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Implantes Dentários , Prótese Total , Mandíbula
5.
ImplantNews ; 9(6a): 159-165, 2012. ilus
Artigo em Português | LILACS, BBO | ID: biblio-851006

RESUMO

O osso homógeno fresco congelado tem sido utilizado no intuito de substituir o osso autógeno. No entanto, as suas propriedades de osseoindução e até mesmo osseocondução não estão bem conceituadas na literatura científica. Esse trabalho teve por objetivo avaliar amostras de tecido ósseo homógeno enxertados em humanos através das análises qualitativas histológica e imuno-histoquímica. Para tal, dez pacientes previamente selecionados foram submetidos à cirurgia de reconstrução de defeitos ósseos em espessura, usando enxerto ósseo homógeno em bloco fresco congelado estabilizado e fixado por meio de parafusos bicorticais. Após período de integração de seis meses foi realizado procedimento de reabertura para instalação dos implantes osseointegráveis. Neste momento cirúrgico, amostras do enxerto ósseo foram removidas por meio de broca trefina. As amostras foram fixadas em formol 10%, levadas ao processamento para corte descalcificado em parafina e coradas por hematoxilina e eosina. Realizou-se processamento imuno-histoquímico para a expressão da enzima Caspase 3. As lâminas foram levadas à microscopia óptica para realização das análises histológica e imuno-histoquímica qualitativas. Os resultados mostraram tecido ósseo não vital, com poucas áreas de deposição de osso neoformado sobre a matriz amorfa, presença de infiltrado inflamatório com áreas de osteomielite e imunomarcação expressiva da enzima Caspase 3. Diante da metodologia empregada e dos resultados obtidos concluiu-se que o enxerto homógeno fresco congelado em bloco não incorporou ao leito receptor após período de reparação de seis meses.


Allogeneic, fresh-frozen bone has been used in order to replace bone autografts. However, its osteoinduction and osteoconduction properties are not well-defined in the scientific literature. This work aimed to evaluate samples of homogenous bone grafts in humans by qualitative histological and immunohistochemical analysis. For this, ten pre-selected patients underwent surgical augmentation of bone defects. The homogenous fresh frozen block bone graft was stabilized and fixed by bicortical screws. After six months, the reopening procedure was performed for installation of osseointegrated implants. At this time surgical bone graft samples were removed by means of drill trephine. The samples were fixed in 10% formalin, processed with decalcified paraffin, and stained with hematoxylin and eosin. Immunohistochemistry was performed for the expression of Caspase 3 enzyme. The slides were brought to light microscopy for qualitative histology and immunohistochemistry. The results showed non-vital bone tissue, with few areas of deposition of new bone formation on the amorphous matrix, presence of chronic inflammatory infiltrate with areas of osteomyelitis, and expressive immunolabeling of Caspase 3. Given the methods employed and the results it was concluded that the allograft fresh-frozen block is not incorporated into the recipient bed after a healing period of six months


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Transplante Ósseo , Imuno-Histoquímica , Teste de Materiais
6.
ImplantNews ; 8(2): 185-189, 2011. ilus, tab
Artigo em Português | LILACS, BBO | ID: lil-599197

RESUMO

O titânio como biomaterial apresenta excelente biocompatibilidade e resistência à corrosão. Vários estudos foram realizados nas últimas décadas sobre modificação da superfície dos implantes de titânio, a fim de otimizar o processo da osseointegração; o uso do laser é um dentre eles. Objetivo: o propósito deste estudo foi avaliar implantes de titânio modificados por feixe de laser de alta intensidade, comparando-os com os implantes usinados, por meio de análise topográfica e histométrica. Métodos: implantes de titânio com duas superfícies diferentes foram inseridas em tíbia de 30 coelhos (um de cada lado, escolhidos de forma aleatória). Grupo I (GI) superfície usinada (grupo controle) e Grupo II (GII) superfície irradiada com laser Yb-YAG (Pulsed Ytterbium Fiber Laser). A caracterização das superfícies foi realizada por meio de MEV-EDS, ângulo de contato e rugosidade média (Ra). Após 30 e 60 dias pós-operatórios, os animais foram submetidos à eutanásia e os implantes foram removidos para análise histológica da interface osso/implante. Resultados: a microfotografia do GII mostrou superfície rugosa e homogênea, com molhabilidade total e rugosidade maior do que o GI. A análise histológica da extensão linear de contato entre o tecido ósseo e a superfície do implante (Elcoi) revelou melhores resultados no GII aos 30 dias (39,26 ± 18,23 e 68,41 ± 13,68, para GI e GII, respectivamente). Conclusão: os implantes de titânio modificados por laser mostraram importantes características superficiais que favoreceram uma precoce osseointegração.


Titanium has proven its suitability as an implant material in surgery over many years. Excellent biocompatibility and corrosion resistance are outstanding features. Implant surfaces always causes concern and interest in scientific communities, due to its close relationship with the time required for osseointegration. Surface modification can be performed by several methods, being laser irradiation one of them. Titanium implants with two different surfaces were inserted in rabbits: Group I (G-I: machined surface, control group), and group II (G-II: laser irradiated, test group) being processed 30 and 60 days after surgery for histological analysis. Surface characterization was performed with SEM-EDS, contact angle measurement, and mean roughness (Ra) parameters. Surface analysis in the GII group showed a nanomorphology affected by melt and quick solidification zones following laser irradiation (SEM), as well as total wettability and Ra mean values significantly higher than in the G-I group. The laser treatment resulted in a homogenized, porous surface, with increased surface area and volume. Histological analysis of bone-implant contact linear extension (BIC) showed better results in G-II at 30 days (39.26 ± 18.23 and 68.41 ± 13.68 for G-I and G-II groups, respectively). Titanium implants modified by laser irradiation showed important features that may accelerate early osseointegration.


Assuntos
Animais , Masculino , Implantes Dentários , Lasers , Osseointegração , Titânio
7.
Dental press j. orthod. (Impr.) ; 15(4): 117-123, jul.-ago. 2010. graf, tab
Artigo em Português | LILACS | ID: lil-555741

RESUMO

OBJETIVO: a proposta desse trabalho foi analisar a fidelidade dos traçados predictivos realizados para cirurgias ortognáticas, por meio de análise cefalométrica do pré e pós-operatório de sete dias, em pacientes submetidos à correção de deformidade mandibular. MÉTODOS: foram utilizadas telerradiografias cefalométricas de perfil de 17 pacientes submetidos à cirurgia ortognática de mandíbula. Foram realizados traçados cefalométricos do pré e do pós-operatório de 7 dias com marcação dos pontos côndilo (Co), pogônio (Pog), goníaco (Go), mento (Me), ponto B (B) e incisivo (I). A análise foi baseada na diferença obtida pela sobreposição dos traçados pré-operatório, predictivo e pós-operatório. Os pontos foram projetados em um plano cartesiano para medição das suas distâncias em milímetros. Os dados obtidos foram submetidos à análise estatística por meio do teste t de Student pareado (± = 0,05). RESULTADOS: no eixo horizontal, foi observada diferença média, entre a mudança planejada e a obtida nos traçados cefalométricos pós-operatórios, estatisticamente significativa nos pontos Pog (p = 0,014) e I (p = 0,008). No eixo vertical, não verificou-se diferença estatística significativa para os pontos cefalométricos marcados (p > 0,05). CONCLUSÕES: o traçado predictivo contribuiu para a avaliação pré-operatória do paciente e, consequentemente, para a otimização do tratamento. Entretanto, ele não se mostrou totalmente fiel nos casos analisados, com leve subestimação das alterações esqueléticas horizontais. Essas alterações devem ser consideradas no planejamento e acompanhamento pós-operatório dos pacientes submetidos à cirurgia ortognática em mandíbula.


OBJECTIVE: The purpose of this study was to assess the accuracy of cephalometric prediction tracings-performed for orthognathic surgery-by means of the cephalometric analysis of preoperative and seven-day postoperative tracings, in patients subjected to correction of mandibular deformities. METHODS: The lateral cephalograms of 17 patients who had been submitted to mandibular orthognathic surgery, three years earlier, were used. Cephalometric tracings were performed in the preoperative and seven-day postoperative periods and the following landmarks were traced: condyle (Co), pogonion (Pog), gonial (Go), menton (Me), B (B) and incisor (I). The analysis was based on the difference obtained by superimposing preoperative, prediction and postoperative tracings. The landmarks were projected onto a Cartesian plane for measuring distances between points in millimeters. The data were statistically analyzed using the paired Student t test (a = 0.05). RESULTS: A statistically significant mean difference was observed between the planned change and the change effectively achieved in the postoperative cephalometric tracings for points Pog (p = 0.014) and I (p = 0.008) on the horizontal axis. No statistically significant difference was found for the aforementioned cephalometric points on the vertical axis (p > 0.05). CONCLUSIONS: Cephalometric prediction tracings contributed to the preoperative evaluation of the patients and consequently to treatment optimization. However, they was not entirely reliable in these cases due to a slight underestimation of horizontal skeletal changes. These changes should be considered in planning and postoperative follow-up of patients subjected to orthognathic surgery in the mandible.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Cefalometria , Mandíbula/cirurgia , Cirurgia Bucal , Face/anormalidades , Avanço Mandibular
8.
Araçatuba; s.n; 2010. 175 p. ilus, graf.
Tese em Português | LILACS, BBO | ID: biblio-866143

RESUMO

Proposição: O objetivo deste estudo foi comparar o comportamento biológico e mecânico do tecido ósseo ao redor de implantes de superfícies comerciais modificada por condicionamento ácido (SA), e usinada (SU), com implantes de superfícies experimentais modificada por laser (SL), e modificada por laser com depósito de sílica (SS), empregando-se as análises biomecânica, topográfica e histométrica. Material e Métodos: Trinta coelhos receberam 120 implantes de 3,75x10mm em suas tíbias direita e esquerda, sendo dois implantes de cada superfície por tíbia. O implante localizado mais superior, instalado na metáfise tibial foi utilizado para o ensaio biomecânico, descrito no capítulo I; e o implante localizado abaixo deste, instalado na epífise tibial foi utilizado para o estudo histométrico, descrito no capítulo II. A morfologia das superfícies dos implantes foi analisada por microscopia eletrônica de varredura (MEV), e por espectroscopia de energia dispersiva de raios X (EDS) antes, e após 4 semanas de implantação e remoção por torque reverso. Medidas de rugosidade e secção transversal foram obtidas. Após períodos de 4, 8, e 12 semanas realizou-se o ensaio biomecânico, e após os animais sofreram eutanásia. As peças do implante localizado na epífise tibial foram levadas ao micrótomo para corte sem descalcificação. A análise histométrica foi realizada empregando-se microscopia óptica. Foi mensurada a extensão linear de contato entre osso e implante (ELCOI), e a área óssea (AO). Uma lâmina de cada superfície do período de 4 semanas foi metalizada para realização da análise do mapeamento elementar por MEV-EDS. Resultados: A caracterização topográfica mostrou diferenças entre as superfícies analisadas, e os valores de rugosidade média das SL e SS foram estatisticamente superiores (p<0,05) a SA. Na comparação estatística dos valores obtidos pelo ensaio biomecânico, verificou-se em 4 semanas que os implantes SS e SL apresentaram torque de remoção superior (p<0,05) aos SU e...


Purpose: The aim of this study was to compare the biologic and mechanical behavior of bone tissue around implants with commercially available surfaces, modified by acid etching (SA), and machined surfaces (SU), with the experimental surfaces modified by laser (SL), and modified by laser with silica deposition (SS), using biomechanical, topographic and histometric analyses. Materials and Methods: Thirty rabbits received 120 implants measuring 3,75x10mm in their right and left tibias, being two implants of each type of surface per tibia. The implant located in the uppermost position, inserted in the tibial metaphysis, was used for the biomechanical test, described in Chapter I; and the implant located below this, inserted in the tibial epiphysis, was used for the histometric study, described in Chapter II. The morphology of the implant surfaces was analyzed by scanning electron microscopy (SEM) and by energy dispersive X-ray spectrometry (EDS) before and after 4 weeks of implantation and removal by reverse torque. Mean roughness and cross-sectional measurements were obtained. After periods of 4, 8, and 12 weeks the biomechanical test was performed, and after this the animals were euthanized. The parts of the implant located in the tibial epiphysis were taken for cutting nondecalcified on a microtome. Histometric analysis was performed using an optical microscope. The bone interface contact (BIC), and the bone area (AO) were measured in percentages. A slide of each surface in the period of 4 weeks was metalized in order to analyze the element mapping by means of SEM-EDS. Results: The topographic characterization showed differences between the analyzed surfaces, and the mean roughness values of SL and SS were statistically higher (p<0,05) than those of SA. In the statistical comparison of the values obtained by the biomechanical test, it was verified that at 4 weeks the implants SS and SL presented a higher removal torque (p<0,05) than SU and SA. At 8 weeks the...


Assuntos
Animais , Coelhos , Materiais Biocompatíveis , Implantes Dentários , Lasers , Osseointegração , Torque , Coelhos
9.
Araçatuba; s.n; 2010. 175 p. ilus, graf.
Tese em Português | LILACS, BBO | ID: lil-671246

RESUMO

Proposição: O objetivo deste estudo foi comparar o comportamento biológico e mecânico do tecido ósseo ao redor de implantes de superfícies comerciais modificada por condicionamento ácido (SA), e usinada (SU), com implantes de superfícies experimentais modificada por laser (SL), e modificada por laser com depósito de sílica (SS), empregando-se as análises biomecânica, topográfica e histométrica. Material e Métodos: Trinta coelhos receberam 120 implantes de 3,75x10mm em suas tíbias direita e esquerda, sendo dois implantes de cada superfície por tíbia. O implante localizado mais superior, instalado na metáfise tibial foi utilizado para o ensaio biomecânico, descrito no capítulo I; e o implante localizado abaixo deste, instalado na epífise tibial foi utilizado para o estudo histométrico, descrito no capítulo II. A morfologia das superfícies dos implantes foi analisada por microscopia eletrônica de varredura (MEV), e por espectroscopia de energia dispersiva de raios X (EDS) antes, e após 4 semanas de implantação e remoção por torque reverso. Medidas de rugosidade e secção transversal foram obtidas. Após períodos de 4, 8, e 12 semanas realizou-se o ensaio biomecânico, e após os animais sofreram eutanásia. As peças do implante localizado na epífise tibial foram levadas ao micrótomo para corte sem descalcificação. A análise histométrica foi realizada empregando-se microscopia óptica. Foi mensurada a extensão linear de contato entre osso e implante (ELCOI), e a área óssea (AO). Uma lâmina de cada superfície do período de 4 semanas foi metalizada para realização da análise do mapeamento elementar por MEV-EDS. Resultados: A caracterização topográfica mostrou diferenças entre as superfícies analisadas, e os valores de rugosidade média das SL e SS foram estatisticamente superiores (p<0,05) a SA. Na comparação estatística dos valores obtidos pelo ensaio biomecânico, verificou-se em 4 semanas que os implantes SS e SL apresentaram torque de remoção superior (p<0,05) aos SU e...


Purpose: The aim of this study was to compare the biologic and mechanical behavior of bone tissue around implants with commercially available surfaces, modified by acid etching (SA), and machined surfaces (SU), with the experimental surfaces modified by laser (SL), and modified by laser with silica deposition (SS), using biomechanical, topographic and histometric analyses. Materials and Methods: Thirty rabbits received 120 implants measuring 3,75x10mm in their right and left tibias, being two implants of each type of surface per tibia. The implant located in the uppermost position, inserted in the tibial metaphysis, was used for the biomechanical test, described in Chapter I; and the implant located below this, inserted in the tibial epiphysis, was used for the histometric study, described in Chapter II. The morphology of the implant surfaces was analyzed by scanning electron microscopy (SEM) and by energy dispersive X-ray spectrometry (EDS) before and after 4 weeks of implantation and removal by reverse torque. Mean roughness and cross-sectional measurements were obtained. After periods of 4, 8, and 12 weeks the biomechanical test was performed, and after this the animals were euthanized. The parts of the implant located in the tibial epiphysis were taken for cutting nondecalcified on a microtome. Histometric analysis was performed using an optical microscope. The bone interface contact (BIC), and the bone area (AO) were measured in percentages. A slide of each surface in the period of 4 weeks was metalized in order to analyze the element mapping by means of SEM-EDS. Results: The topographic characterization showed differences between the analyzed surfaces, and the mean roughness values of SL and SS were statistically higher (p<0,05) than those of SA. In the statistical comparison of the values obtained by the biomechanical test, it was verified that at 4 weeks the implants SS and SL presented a higher removal torque (p<0,05) than SU and SA. At 8 weeks the...


Assuntos
Animais , Coelhos , Materiais Biocompatíveis , Implantes Dentários , Lasers , Osseointegração , Torque , Coelhos
10.
Rev. Clín. Ortod. Dent. Press ; 8(1): 69-74, fev.-mar. 2009. ilus
Artigo em Português | LILACS, BBO | ID: lil-519778

RESUMO

A expansão rápida de maxila é um procedimento ortopédico essencial para o tratamento de deficiência transversa da maxila e mordida cruzada posterior. O uso do arco transpalatino como contenção é uma rotina ortodôntica para aumentar a estabilidade da expansão obtida. O propósito deste trabalho foi relatar uma complicação proveniente do arco transpalatino que causou necrose tecidual e fístula buconasal. Os autores descreveram o tratamento cirúrgico preconizado para oclusão da mesma. O acompanhamento pós-operatório de um ano mostrou a eficácia da técnica descrita.


Assuntos
Humanos , Feminino , Adolescente , Fístula Bucal/cirurgia , Fístula Bucal/etiologia , Técnica de Expansão Palatina/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA