Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Medical Instrumentation ; (6): 380-382, 2015.
Artigo em Chinês | WPRIM | ID: wpr-265611

RESUMO

To assure the clinical quality and requirement of CT shelter used in field environment, the factors related with the practical application were studied. The evaluation indicators of CT equipment were investigated. Based on the technical modification of vehicle shelter CT, the scanning conditions of shelter CT were analyzed. Moreover, the comparative study was done between shelter CT and common CT in hospitals. In result, in order to meet maneuverability application in the field, vehicle shelter CT was restrictive by the field conditions, traffic impacts and running requirement. The application of vehicle shelter CT was affected by the factors, such as mechanical stabilization, moving precision, power fluctuations and variations of temperature and humidity, etc. The results were helpful to improve the clinical quality of vehicle shelter CT and made a base for the quality control study in the future.


Assuntos
Umidade , Temperatura , Tomografia Computadorizada por Raios X
2.
Chinese Journal of Medical Instrumentation ; (6): 460-463, 2013.
Artigo em Chinês | WPRIM | ID: wpr-259952

RESUMO

To improve the usage rate and quality of emergency equipment in the hospital, the emergency equipment management was studied. The specialized management and common use of emergency equipment in a hospital was analysed with statistical methods. The usage rate, economic effectiveness and management quality of the equipment were evaluated. Based on the practical experience, the superiorities of the specialized management and common use of emergency equipment in hospitals were summarized, and the inferior positions and their improvement approaches were proposed. As a result, the hospital resource allocation was optimized and the equipment management level was improved by using the specialized management and common use of emergency equipment in the hospital.


Assuntos
Serviço Hospitalar de Emergência , Administração de Materiais no Hospital
3.
Chinese Journal of Medical Instrumentation ; (6): 4-7, 2012.
Artigo em Chinês | WPRIM | ID: wpr-325949

RESUMO

Three algorithms of electrical impedance tomography (EIT) are studied in this paper. The image resolution, anti-noise property and computation rapidity of the reconstruction algorithms are compared. As a result, it shows that back-projection algorithm has good anti-noise property, that NOSER algorithm generates images with good resolution, and that sensitivity matrix algorithm has moderate property.


Assuntos
Algoritmos , Impedância Elétrica , Processamento de Imagem Assistida por Computador , Métodos
4.
Chinese Journal of Medical Instrumentation ; (6): 274-276, 2011.
Artigo em Chinês | WPRIM | ID: wpr-330462

RESUMO

Clinical experiments are always used to evaluate the safety and validity of medical devices. The experiments have two types of clinical trying and testing. Ethic review must be done by the ethics committee of the medical department with the qualification of clinical research, and the approval must be made before the experiments. In order to ensure the safety and validity of clinical experiments of medical devices in medical institutions, the contents, process and approval criterions of the ethic review were analyzed and discussed.


Assuntos
Humanos , Pesquisa Biomédica , Ética , Equipamentos e Provisões , Ética , Revisão Ética
5.
Journal of Biomedical Engineering ; (6): 10-13, 2009.
Artigo em Chinês | WPRIM | ID: wpr-318122

RESUMO

Piglets having each a body weight of 20-30 kg and an abdominal perimeter like human's were used in the experiment. Being guided by ultrasound, we stabbed the piglet's abdomen, placed a catheter on the liver's lower margin, then injected the anticoagulated blood through the catheter by electrical infusion pump with constant speed respectively, and monitored the whole process by EIT. We observed the image change, using Ultrasound and CT to examine the area of blood injection after the end of monitoring,and we dissected to check the result of observations. The results reveal: (1) Ultrasound, CT and dissection are all able to find out a large amount of blood in piglet's abdominal cavity; (2) The pixel value of EIT target area decreases with the increase of blood, and the change in impedance image can be obviously observed. Therefore, this animal model is suitable for simulating intraperitoneal bleeding, and the speed of bleeding therein can be controlled. We can get a limpid image when EIT is used for monitoring the intraperitoneal bleeding simulated by this animal model.


Assuntos
Animais , Feminino , Masculino , Impedância Elétrica , Hemorragia , Diagnóstico , Interpretação de Imagem Assistida por Computador , Métodos , Monitorização Fisiológica , Métodos , Doenças Peritoneais , Diagnóstico , Pletismografia de Impedância , Métodos , Suínos , Tomografia , Métodos
6.
Chinese Journal of Trauma ; (12): 271-274, 2009.
Artigo em Chinês | WPRIM | ID: wpr-395764

RESUMO

Objective To apply electrical impedance tnmography that is a new evaluation ap-proach to monitor the development of retroperitoneal injury. We used retroperitoneal inject blood model in pigs to study the feasibility on monitoring retroperitoneal bleeding and to provide premise in theory and practice for clinical application. Methods Five pigs were used on the experiment. We insert a vessel into the retroperitoneal and inject blood to simulate retroperitoneal bleeding. Sixteen electrodes were atta-ched on the abdominal region circumference of pigs and used for electrical current injection and surface voltage measurement. Then the monitoring images were performed by electrical impedance tomography. Results The images of electrical impedance tomography retroperitoneal inject blood model of five pigs were clear, the minimal impedance scale was decreasing significantly as the bleeding volume increasing and the images were changed significantly too. The computerized tomography and the dissecting results confirmed the blood was limited in retroperitoneal. Conclusions The establishments of pigs retroper-itoneal inject blood model was successful. The images of electrical impedance tomography retroperitoneal inject blood model were clear with significant contrast. It's feasible to use electrical impedance tomography system to monitor the retroperitoneal bleeding. This technique may become a useful tool for monitoring ret-roperitoneal injury in intensive care patients.

7.
Chinese Journal of Tissue Engineering Research ; (53): 9463-9466, 2009.
Artigo em Chinês | WPRIM | ID: wpr-404623

RESUMO

To improve the accuracy of finite element method used in medicine field, it is necessary to build the finite element model including real structural information of tissues in human body. In this study, an edge extracting method was introduced on CT image of human body, and the method of building the two-dimensional finite element model from the extracted edges was then raised. Using the above methods, a finite element model of human body containing real structural information can be successfully made. The methods were used for many CT images of hospitals and tested to be simple, fast and adaptable. The study makes a good foundation for further finite element analysis based on medicine images.

8.
Journal of Biomedical Engineering ; (6): 663-667, 2005.
Artigo em Chinês | WPRIM | ID: wpr-354226

RESUMO

The contour line of human brain was simulated by the curve-fitting methods and then the inner area was discretized by advancing-front methods which was improved at last. The curve-fitting result was similar to the CT picture of the human brain and the discrete result of inner area could be completed quickly by improved advanced-front methods. A finite element model with the contour line of human brain was built primarily which will contribute to the next algorithm study of electrical impedance tomography in human brain.


Assuntos
Humanos , Algoritmos , Encéfalo , Análise de Elementos Finitos , Modelos Anatômicos , Modelos Neurológicos
9.
Chinese Medical Equipment Journal ; (6)1989.
Artigo em Chinês | WPRIM | ID: wpr-588163

RESUMO

The reverse problem of Electrical impedance tomography(EIT) is a highly ill-posed problem.It is concluded that spatial prior information could improve the final image quality.This paper proposes a new method for obtaining prior information.By this method,the inspected cross-section contour and internal structure for EIT can be achieved.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA