Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Adicionar filtros








Intervalo de ano
1.
China Occupational Medicine ; (6): 572-577, 2020.
Artigo em Chinês | WPRIM | ID: wpr-881940

RESUMO

OBJECTIVE: To establish a method for simultaneous detection of 6 isomers of dimethylaniline(DMA) in workplace air by gas chromatography(GC). METHODS: The vapor and aerosol DMA in workplace air were collected by GDH-1 air sampling tube, and desorbed and eluted with absolute ethanol, then separated by a special capillary column for amines analysis, and finally detected by GC-flame ionization detector. RESULTS: The quantitative detection range of 6 isomers of DMA was 0.26-226.66 mg/L, with all the correlation coefficients greater than 0.999 00. The minimum detectable concentration was 0.01-0.02 mg/m~3, and the minimum quantification concentration was 0.04-0.05 mg/m~(3 )(15.00 L sample, 2.00 mL sample solution). The average desorption and elution efficiency was 92.48%-104.60%. The within-run relative standard deviations(RSD) was 0.31%-4.51%, and the between-run RSD was 1.23%-6.03%. The samples can be sealed and stored for more than 19 days at room temperature. CONCLUSION: The method is suitable for simultaneous detection of 6 isomers of DMA in workplace air.

2.
China Occupational Medicine ; (6): 86-90, 2020.
Artigo em Chinês | WPRIM | ID: wpr-881871

RESUMO

OBJECTIVE: To establish a method for simultaneous detection of 2-aminopyridine, 3-aminopyridine and 4-aminopyridine in workplace air by solvent eluting-gas chromatography. METHODS: 2-aminopyridine, 3-Aminopyridine and 4-aminopyridine in workplace air were collected by glass fiber filter paper dipped with sulfuric acid solution, and eluted using sodium hydroxide solution. After that, the eluent was separated by capillary column, and finally detected using the nitrogen and phosphorus detector. RESULTS: The quantitative determination ranges of 2-aminopyridine, 3-aminopyridine and 4-aminopyridine were 0.30-800.00, 0.80-800.00 and 2.00-800.00 mg/L respectively, with the correlative coefficients greater than 0.999 9. The minimum detectable concentrations were 4.67, 8.00 and 40.00 μg/m~3 respectively, and the minimum quantification concentrations were 14.00, 28.00 and 133.33 μg/m~3(45.00 L sample, 3.00 mL eluent) respectively. The average elution efficiencies were 79.63%-98.61%, 83.80%-101.42% and 81.60%-100.29% respectively. The within-run relative standard deviations(RSD) were 1.13%-3.65%, 1.47%-4.00% and 1.94%-5.15% respectively, and the between-run RSD were 1.77%-5.30%, 2.06%-4.65% and 2.59%-6.46% respectively. Samples were stable at room temperature for at least 14 days. CONCLUSION: This method is appropriate to be applied for simultaneous detection of 2-aminopyridine, 3-aminopyridine and 4-aminopyridine in workplace air.

3.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 476-480, 2019.
Artigo em Chinês | WPRIM | ID: wpr-805355

RESUMO

Objective@#To explore the applicability of Singapore semi-quantitative assessment method and international committee on mining and metals occupational health risk assessment method in occupational health risk assessment of ceramic enterprises.@*Methods@#From March 2017 to May 2018, A ceramic enterprise was selected for the investigation and testing of occupational health, and the risk assessment of the occupational-disease-inductive factors in the workplace was conducted by the semi-quantitative assessment method of Singapore and the occupational health risk assessment method of the international committee on mining and metals.@*Results@#The occupational-disease-inductive factors in the production process of this ceramic enterprise mainly include silicon dust, noise, high temperature, carbon monoxide, carbon dioxide and so on. The two risk assessment methods were applied to assess the risk of occupational-disease-inductive factors in the workplace, and the results showed that the high risk level was 16.67%, the medium risk level was 63.33%, and the low risk level was 20.00%. The risk level of silicon dust is from low risk to high risk.@*Conclusion@#The semi-quantitative assessment method and the occupational health risk assessment method of the International Commission on Mining and Metals are simple to operate and practical, and are suitable for the assessment of occupational hazards in ceramic enterprises.

4.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 384-389, 2019.
Artigo em Chinês | WPRIM | ID: wpr-805124

RESUMO

Objective@#To develop a solvent desorption-gas chromatography method for simultaneous determination of methyl methacrylate (MMA) , ethyl methacrylate (EMA) , n-propyl methacrylate (PMA) and butyl methacrylate (BMA) in workplace air.@*Methods@#MMA, EMA, PMA and BMA in workplace air were captured by charcoal tubes and desorbed with carbon disulfide, separated through capillary chromatographic column, and then analyzed by gas chromatography-flame ionization detector.@*Results@#The linear ranges of MMA, EMA, PMA and BMA were 0-8 305.00 mg/L, 0-9 080.50 mg/L, 0-8 899.00 mg/L and 0-8 371.00 mg/L respectively, and the related coefficients were between 0.999 96-0.999 98. The relative standard deviations (RSD) within the group were 0.56%-1.71%, 0.45%-1.65%, 0.51%-1.49% and 0.45%-1.50% respectively, and the RSD between the group were 1.14%-2.79%, 0.79%-2.13%, 0.93%-2.30% and 1.09%-2.84% respectively. The average desorption efficiencies were 95.76%-99.58%, 97.82%-102.28%, 98.55%-102.28%and 98.70%-102.40% respectively. The minimum quantification concentrations were 0.12 mg/m3, 0.10 mg/m3, 0.07 mg/m3 and 0.07 mg/m3 respectively (3.00 L sample) . The samples could be stored at room temperature for at least 7 days.@*Conclusion@#This method could be used for monitoring of MMA, EMA, PMA and BMA in workplace air.

5.
China Occupational Medicine ; (6): 465-468, 2019.
Artigo em Chinês | WPRIM | ID: wpr-881822

RESUMO

OBJECTIVE: To establish a method for simultaneously detecting methyl methacrylate, ethyl methacrylate, n-propyl methacrylate and butyl methacrylate in workplace air by a portable gas chromatography-mass spectrometer(GC-MS) technique. METHODS: The portable GC-MS hand-held probe was used for sampling and detection. Samples were separated with DB-5 rapid chromatographic column in order to maintain retention time and characteristics of the ions, and quantified by standard curve method. RESULTS: The linear correlation of this method was higher than 0.999 0. The minimum detection concentration was 0.03-0.06 mg/m~3, and the minimum quantitation concentration was 0.10-0.20 mg/m~3. The standard recovery rate was 82.22%-91.24%. The within-run and the between-run relative standard deviation were 7.67%-14.63% and 10.40%-13.79% respectively. CONCLUSION: The portable GC-MS technique could be used for qualitative and quantitative detection of above-mentioned four methylacrylate compounds in workplace air.

6.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 471-473, 2018.
Artigo em Chinês | WPRIM | ID: wpr-806625

RESUMO

Objective@#A solvent desorption-gas chromatography method for determination of ethylal in workplace air has been established.@*Methods@#Ethylal in workplace air was collected by activated carbon tube and desorbed with carbon disulfide, and the desorption solutions were analysed by capillary column GC with FID detector.@*Results@#The method presented a good linearity in the range of 0.87~34 800.00 mg/L of ethylal in the standard solution, with the correlation coefficient being r=0.999 7. The limit of detection and the limit of quantification of this method were respectively 0.20 mg/L and 0.80 mg/L, and the minimum detectable concentration and the minimum quantification concentration of this method were respectively 0.17 mg/m3 and 0.60 mg/m3 per 1.50 L of air.The within-run precision of the method was 2.93%-6.20%, and the between-run precision 3.67%-6.44%. The desorption efficiency between 94.22%-97.27%. Ethylal in activated carbon tube could be kept at least 7 days at room temperature without significant loss.@*Conclusion@#The method could be used for determination of ethylal in workplace air.

7.
China Occupational Medicine ; (6): 363-368, 2018.
Artigo em Chinês | WPRIM | ID: wpr-881710

RESUMO

OBJECTIVE: To explore the feasibility of simultaneous detection of 45 kinds of common organic compounds in workplace air by solvent desorption-gas chromatography method.METHODS: A total of 45 kinds of common organic compounds such as benzene,1,2-dichloroeyhane,n-hexane and trichloroethylene in workplace air were collected with activated carbon tube and desorbed with carbon disulfide,separated by capillary chromatographic column,and detected with flame ionization detector.RESULTS: There was good linear relationship in the selected range.The correlation coefficients was 0.999 92-0.999 99.The detection limit was 0.03-0.30 mg/L and the minimum detectable concentration range was 0.01-0.20 mg/m~3( sample volume was 3.00 L).The average desorption efficiencies was 75.4%-105.7%.The within-run and between-run relative standard deviations were 0.4%-6.7% and 1.8%-7.9%,respectively.The sampling efficiency was 91.9%-100.0%.CONCLUSION: The method is simple,high sensitivity and good precision,which can be used for simultaneous detection of 45 kinds of common coexisting organic compounds in workplace air.

8.
China Occupational Medicine ; (6): 91-94, 2018.
Artigo em Chinês | WPRIM | ID: wpr-881671

RESUMO

OBJECTIVE: To develop a solvent desorption-gas chromatography method for detecting ethylene glycol monopropyl ether( EGME) in workplace air. METHODS: EGME in workplace air was captured by charcoal tubes and desorbed by methanol-methylene chloride(5∶ 95,V/V),separated by capillary chromatographic column,and detected by flame ionization detector. RESULTS: The good linear range of EGME was 1. 37-1 913. 80 mg/L,and the correlation coefficient was 0. 999 90. The detection limit was 0. 06 mg/L. The minimum detectable concentration was 0. 02 mg/m3.The average desorption efficiency was 97. 81%-104. 70%. The within-run relative standard deviation( RSD) was 1. 94%-2. 99%,and the between-run RSD was 3. 24%-4. 53%. The samples could be stored at room temperature for at least 14 days. CONCLUSION: This method could be used for detection of EGME in workplace air.

9.
China Occupational Medicine ; (6): 55-59, 2018.
Artigo em Chinês | WPRIM | ID: wpr-881663

RESUMO

OBJECTIVE: To explore the applicability of Singapore Ministry of Manpower( MOM) risk model and MES model in risk assessment of occupational health hazard caused by chemical poisons in shoemaking enterprises. METHODS: A medium-sized shoemaking enterprise in Guangzhou City was selected as the research object to carry out on-the-spot investigation of occupational health,measure the level of chemical hazards in the air of the workplace. Occupational health risk assessment of chemical toxins in the workplace was conducted using the MOM model and the MES model,and the results of the two evaluations were compared. RESULTS: The occupational chemical hazards in workplace of the shoemaking enterprise mainly included the toluene,xylene,ethyl acetate,butyl acetate,n-hexane,and 1,2-dichloroethan( 1,2-DCE). The concentration-time weighted average( CTWA) of 1,2-DCE at the stitching post,methylbenzene at the brush coating post and ethyl acetate at the cleaning post exceeded occupational exposure limits. The MOM model assessment results showed that methylbenzene was of high risk and 1,2-DCE was of medium risk in brush coating post. n-Hexane and1,2-DCE were of medium risk in stitching post. Ethyl acetate and 1,2-DCE was of medium risk in cleaning post. The results of the MES model evaluation showed that the risk level of n-hexane and 1,2-DCE used in sticking,brush coating and cleaning posts was extremely high and the remaining chemicals were highly dangerous. CONCLUSION: Both MOM model and MES model can easily predict and assess the occupational health risk of various posts in shoemaking enterprises to some extent. The assessment result of MES model is more practical than that of MOM model.

10.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 149-152, 2017.
Artigo em Chinês | WPRIM | ID: wpr-808112

RESUMO

Objective@#To develop a new solid sorbent tube for capturing glycidyl methacrylate (GMA) in workplace air, and establish a complete set of method.@*Methods@#GMA in workplace air was captured by the new solid sorbent tube filled with carbon aerogel adsorbent, desorbed with solution of 50% (V/V) dimethylformamide-carbon disulfide, separated through capillary chromatographic column, and then analyzed by gas chromatography-flame ionization detector.@*Results@#The linear range of GMA was 0.38-604.80 mg/L, and the related coefficient was 0.999 82. The within-run and the between-run precision were 1.11%-2.80% and 2.53%-4.84% respectively. The average desorption efficiency was 93.20%-94.97%. The minimum quantification concentration and The minimum quantification concentration were 0.02 and 0.07 mg/m3 respectively (3.00 L sample) . Samples could be stored for at least 8 days at room temperature.@*Conclusion@#The newly developed solid sorbent tube and its complete set of gas chromatography method is simple, and has high sensitivity and precision, so it can be used for sampling and quantitative detection of GMA in workplace air.

11.
China Occupational Medicine ; (6): 211-214, 2017.
Artigo em Chinês | WPRIM | ID: wpr-881601

RESUMO

OBJECTIVE: To establish a solvent desorption-gas chromatography method for simultaneous determination of 2-methoxyethyl acetate(2-MEA) and 2-ethoxyethyl acetate(2-EEA) in the workplace air. METHODS: 2-MEA and 2-EEA in workplace air were captured by charcoal tubes and desorbed with solution of 5. 00%(V/V) methanol-methylene chloride,separated through capillary chromatographic column,and then analyzed by gas chromatography-flameionization detector. RESULTS: The linear ranges of 2-MEA and 2-EEA were 1. 50-2 403. 84 and 1. 79-2 871. 20 mg/L,respectively.The correlation coefficient were 0. 999 8. The minimum quantification concentrations were 0. 20 and 0. 09 mg/m~3,respectively(3. 00 L sample). The average desorption efficiencies were 98. 08%-99. 67% and 94. 34%-99. 79%,respectively. The within-run relative standard deviations(RSD) were 1. 77%-3. 51% and 1. 72%-3. 01%,respectively.The between-run RSD were 2. 27%-4. 44% and 2. 31%-4. 19%,respectively. The samples could be stored at room temperature for at least 14 days. CONCLUSION: This method could be used for simultaneous sampling and quantitative detection of 2-MEA and 2-EEA in workplace air.

12.
China Occupational Medicine ; (6): 75-79, 2017.
Artigo em Chinês | WPRIM | ID: wpr-881583

RESUMO

OBJECTIVE: To establish a methodology for simultaneous detection of chloromethyl methyl ether( CMME) and bis-chloromethyl ether( BCME) in workplace air by gas chromatography. METHODS: CMME and BCME in workplace air were collected with absorption solution which was also derivatization solution. The derivative products were extracted using n-hexane alkaline medium. The extracts were separated by capillary column and detected with electron capture detector.The quantification was performed by use of standard curves. RESULTS: The linearity ranges of CMME and BCME were2. 00-80. 00 and 1. 32-52. 80 ng,respectively. The correlation coefficients were both 0. 999 93. The minimum detectable concentrations were both 0. 030 μg / m3 and the minimum quantification concentrations were both 0. 100 μg / m3( 7. 50 L sample). The recovery rates were 99. 35%-101. 00% and 97. 99%-101. 70% respectively. The within-run relative standard deviations( RSD) were 2. 73%-4. 46% and 2. 61%-3. 82% respectively,and the between-run RSD were3. 10%-5. 50% and 3. 89%-5. 38% respectively. The sampling efficiencies were 92. 43%-96. 25% and 91. 43%-94. 03%respectively. The samples were stable at room temperature for at least 15 days. CONCLUSION: This method is suitable for simultaneous detection of CMME and BCME in workplace air.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA