Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Southern Medical University ; (12): 1399-1405, 2020.
Artigo em Chinês | WPRIM | ID: wpr-880776

RESUMO

OBJECTIVE@#To investigate the protective effect of arctiin with anti-inflammatory bioactivity against triptolide-induced nephrotoxicity in rats and explore the underlying mechanism.@*METHODS@#Forty SD rats were divided into 4 groups for gastric lavage of normal saline, arctiin (500 mg/kg), triptolide (500 μg/kg), or both arctiin (500 mg/kg) and triptolide (500 μg/kg). Blood samples were collected for analysis of biochemical renal parameters, and the renal tissues were harvested for determining the kidney index and for pathological evaluation with HE staining. In the @*RESULTS@#In SD rats, arctiin significantly antagonized triptolide-induced elevation of BUN, Scr and kidney index (@*CONCLUSIONS@#Arctiin can protect the kidney from triptolide-induced damages in rats possibly through the anti-inflammatory pathway.


Assuntos
Animais , Ratos , Anti-Inflamatórios , Diterpenos/toxicidade , Compostos de Epóxi/toxicidade , Furanos , Glucosídeos , Rim/efeitos dos fármacos , Fenantrenos/toxicidade , Ratos Sprague-Dawley
2.
Chinese Journal of Radiation Oncology ; (6): 541-543, 2010.
Artigo em Chinês | WPRIM | ID: wpr-385968

RESUMO

Objective To assess set-up errors measured with kilovoltage cone-beam CT (KV-CBCT), and the impact of online corrections on margins required to account for set-up variability during IMRT for patients with prostate cancer. Methods Seven patients with prostate cancer undergoing IMRT were enrolled onto the study. The KV-CBCT scans were acquired at least twice weekly. After initial set-up using the skin marks, a CBCT scan was acquired and registered with the planning CT to determine the setup errors using an auto grey-scale registration software. Corrections would be made by moving the table if the setup errors were considered clinically significant ( i. e. , > 2 mm). A second CBCT scan was acquired immediately after the corrections to evaluate the residual error. PTV margins were derived to account for the measured set-up errors and residual errors determined for this group of patients. Results 197 KV-CBCT images in total were acquired. The random and systematic positioning errors and calculated PTV margins without correction in mm were:a) Lateral 3. 1,2. 1,9. 3;b) Longitudinal 1.5, 1.8, 5. 1 ;c) Vertical 4. 2,3.7, 13.0. The random and systematic positioning errors and calculated PTV margin with correction in mm were:a) Lateral 1.1,0. 9, 3.4;b) Longitudinal 0. 7, 1.1, 2. 5;c) Vertical 1.1, 1.3, 3.7. Conclusions With the guidance of online KV-CBCT, set-up errors could be reduced significantly for patients with prostate cancer receiving IMRT. The margin required after online CBCT correction for the patients enrolled in the study would be appoximatively 3-4 mm.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA