Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Postgraduates of Medicine ; (36): 29-32, 2013.
Artigo em Chinês | WPRIM | ID: wpr-438017

RESUMO

Objective Through the effect comprison of analgesic calm and side-effect on postoperative analgesia under different concentration dexmedetomidine with butorphanol,to research the best concentration of dexmedetomidine on postoperative analgesia.Methods Ninety patients with lower abdominal surgery with general anesthesia,ASA Ⅰ-Ⅱ grade,were divided into 3 groups by random digits table:group A,group B and group C,each group with 30 cases.The group A received 0.2 μg/ (kg·h) dexmedetomidine.The group B received 0.3 μg/ (kg ·h) dexmedetomidine,both added 0.15 mg/kg butorphanol and 8 mg ondansetron.The group C only received 0.15 mg/kg butorphanol and 8 mg ondansetron.Applied patient controlled intravenous analgesia (PCIA) pump continuous infusion gave total 100 ml,background infusion 2 ml/h,patient controlled analgesia (PCA) 2 ml,lock time 30 min,analgesia was continued 48 h.Below were recorded at 2,6,12,24 and 48 h after the beginning of PCIA:analgesia VAS score,ramsay sedation scale (RSS),adverse reaction.The total number of button pressing of PCA and the consumption of patient controlled liqnid analgesia (PCLA) solution were also recorded.Results There was no statistically significant difference in VAS score after each time point between group A and group B (P> 0.05).The VAS scores after each time point in group A and group B were significantly lower than those in group C [(2.7 ±0.8),(2.6 ± 0.8) scores vs.(3.2 ± 0.9) scores; (1.8 ± 0.6),(1.7 ± 0.6) scores vs.(2.5 ± 0.6) scores; (1.0 ±0.6),(0.9 ±0.7) scores vs.(1.8 ±0.6) scores; (1.0 ±0.5),(0.8 ±0.5) scores vs.(1.4 ±0.5) scores; (0.7 ±0.5),(0.7 ±0.4) scores vs.(1.0 ±0.5) scores,P <0.05].There was no statistically significant difference in RSS score among 3 groups (P > 0.05).The RSS scores after 6,12,24 and 48 h in group A and group B were significantly higher than those in group C [(2.6 ±0.5),(3.5 ±0.6) scores vs.(2.0 ±0.3) scores; (2.9 ± 0.6),(3.8 ± 1.2) scores vs.(2.4 ± 0.3) scores; (2.8 ± 0.7),(3.9 ± 0.7) scores vs.(2.5 ± 0.4)scores; (2.8 ± 0.6),(3.9 ± 0.6) scores vs.(2.5 ± 0.5) scores,P < 0.05],group A was significantly higher than those in group B (P< 0.05).There was no statistically significant difference in rate of hypoxemia among 3 groups (P > 0.05).The rates of nausea and vomit,deliration in group A and group B were significantly lower than those in group C [3.3%(1/30),0 vs.10.0%(3/30) ;0,0 vs.10.0%(3/30),P< 0.05].The rates of hypotension and bradycardia in group B were significantly lower than those in group A and group C[16.7% (5/30) vs.3.3%(1/30),0;20.0%(6/30) vs.3.3%(1/30),0,P< 0.05].The total number of button pressing of PCA 24 h and the consumption of PCLA solution in group C were significantly higher than those in group A and group B [(13.9 ±2.4) times vs.(9.7 ±2.2),(7.4 ± 1.5) times; (60.9 ± 1.8) ml vs.(54.5 ± 1.2),(50.7 ± 0.7) ml,P < 0.05].Conclusion Concentration 0.2 μ g/(kg· h) dexmedetomidine with butorphanol has better effects on postoperative analgesia and calm,less side-effect.

2.
Journal of Central South University(Medical Sciences) ; (12): 1063-1069, 2009.
Artigo em Inglês | WPRIM | ID: wpr-814192

RESUMO

OBJECTIVE@#To develop a rapid and simple immunoassay to detect antibodies in the sera of patients infect Schistosoma japonicum (S. japonicum).@*METHODS@#Soluble egg antigen (SEA) of S. japonicum conjugated with colloidal carbon in advance was used to react with the antibodies in the sera of patients with schistosomiasis. Then the carbon-antigen-antibody complex would be captured by SEA which had been absorbed on the nitrocellulose membrane and a gray band was shown.@*RESULTS@#A total of 137 sera samples from S. japonicum epidemic area were tested, and the consistency, sensitivity, and specificity of colloidal carbon dipstick assay were 98.54%, 98.99%, and 97.37%, respectively, compared with the IHA method. The gray scale of bands on the dipstick was curvilinear to serum titer which revealed that the assay could be used semi-quantitatively in serum analysis.@*CONCLUSION@#Colloidal carbon dipstick assay is not only rapid and simple, but also sensitive and specific for the detection of serum antibodies of schistosomiasis japonica. It will be a practical immunological assay for the diagnosis of schistosomiasis in the field testing.


Assuntos
Animais , Humanos , Anticorpos Anti-Helmínticos , Sangue , Carbono , Química , Coloides , Química , Imunoensaio , Métodos , Schistosoma japonicum , Alergia e Imunologia , Esquistossomose Japônica , Sangue , Diagnóstico , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA