Acta Pharmaceutica Sinica ; (12): 64-67, 2004.
Artigo em Inglês | WPRIM | ID: wpr-301147

RESUMO

<p><b>AIM</b>To establish a new and simple flow injection method for the rapid determination of acetylspiramycin (ASPM).</p><p><b>METHODS</b>ASPM was determined by chemiluminescence (CL) method combined with flow injection (FI) technology, which was based on the inhibitive effect of ASPM on the chemiluminescence reaction of the luminol-K3Fe (CN)6 system.</p><p><b>RESULTS</b>The decrease of chemiluminescence intensity was proportional to the logarithm of ASPM concentration (0.1-100) microgram.L-1, the detection limit was 40 ng.L-1 (3 sigma). The whole process, including sampling and washing, could be completed in 0.5 min with a RSD less than 3.0% (n = 5).</p><p><b>CONCLUSION</b>The FI-CL method is of both high sensitivity and good selectivity giving a throughput of 120 h-1. The proposed method was applied successfully to the determination of ASPM in pharmaceutical preparations and human urine without any pre-treatment. It was found that the ASPM concentration reached its maximum after being orally administrated for two hours.</p>


Assuntos
Humanos , Masculino , Antibacterianos , Sangue , Urina , Análise de Injeção de Fluxo , Medições Luminescentes , Luminol , Química , Microquímica , Espiramicina , Sangue , Urina
2.
Acta Pharmaceutica Sinica ; (12): 793-797, 2002.
Artigo em Inglês | WPRIM | ID: wpr-312047

RESUMO

<p><b>AIM</b>To establish a simple and novel method for the determination of vitamin B2 rapidly in pharmaceutical preparations.</p><p><b>METHODS</b>Vitamin B2 was determined by a chemiluminescence (CL) sensor combined with flow-injection (FI) technology. The analytical reagents involved in the CL reaction, luminol and hexacyanoferrate (III), were both immobilized on an anion-exchange resin column in FI system. The CL signal produced by the reaction between luminol and hexacyanoferrate (III), which were eluted from the column through sodium phosphate injection, decreased in the presence of vitamin B2.</p><p><b>RESULTS</b>The decreased CL intensity was linearly correlated with the vitamin B2 concentration in the range of 0.01-1.0 microgram.mL-1, the detection limit was 4.0 ng.mL-1 vitamin B2 (3 sigma). At a flow rate of 2.0 mL.min-1, the procedure including sampling and washing could be performed in 2 min with a relative standard deviation of less than 3.0%.</p><p><b>CONCLUSION</b>The flow sensor exhibited both good sensitivity and stability. It could be reused more than 450 times and has been applied successfully to the analysis of vitamin B2 in pharmaceutical preparations.</p>


Assuntos
Análise de Injeção de Fluxo , Métodos , Medições Luminescentes , Luminol , Riboflavina , Comprimidos , Química