1.
China Occupational Medicine ; (6): 211-214, 2017.
Artigo em Chinês | WPRIM | ID: wpr-881601

RESUMO

OBJECTIVE: To establish a solvent desorption-gas chromatography method for simultaneous determination of 2-methoxyethyl acetate(2-MEA) and 2-ethoxyethyl acetate(2-EEA) in the workplace air. METHODS: 2-MEA and 2-EEA in workplace air were captured by charcoal tubes and desorbed with solution of 5. 00%(V/V) methanol-methylene chloride,separated through capillary chromatographic column,and then analyzed by gas chromatography-flameionization detector. RESULTS: The linear ranges of 2-MEA and 2-EEA were 1. 50-2 403. 84 and 1. 79-2 871. 20 mg/L,respectively.The correlation coefficient were 0. 999 8. The minimum quantification concentrations were 0. 20 and 0. 09 mg/m~3,respectively(3. 00 L sample). The average desorption efficiencies were 98. 08%-99. 67% and 94. 34%-99. 79%,respectively. The within-run relative standard deviations(RSD) were 1. 77%-3. 51% and 1. 72%-3. 01%,respectively.The between-run RSD were 2. 27%-4. 44% and 2. 31%-4. 19%,respectively. The samples could be stored at room temperature for at least 14 days. CONCLUSION: This method could be used for simultaneous sampling and quantitative detection of 2-MEA and 2-EEA in workplace air.

2.
Korean Journal of Occupational and Environmental Medicine ; : 276-286, 1999.
Artigo em Coreano | WPRIM | ID: wpr-87164

RESUMO

This study was carried out to evaluate the association between urinary 2-ethoxyacetic acid(EAA) as a new indicator of biological monitoring for the workers exposed to 2-etho xyethyl acetate(EEA) and independent variables such as the EEA exposure concentration, exposure dose, total EEA absorption amount, work duration, and alcohol consumption. In this study the subjects were the total of 160 drawn from 75 workers who were occupationally exposed to EEA and 85 workers who were not. The results were as follows: 1. In the electronic painting workplace, EEA exposure concentration in the breathing zone of the spray workers was the highest, as showed 2. 88ppm(0. 01-15.1 ppm) and cases of exceeded threshold limit value(TLV = 5ppm) were 12.0% among the total of 75 exposed workers. 2. Four workers(5. 4%) of exposed workers indicated more than 50.0 mg/g creatinine of urinary EAA, the geometric mean urinary EAA in exposed workers was 2.49 mg/g creatinine, and was higher than that of workers who were not exposed. 3. In the spray workers of auto products, the geometric mean of urinary BAA was the highest showing 5.76 mg/g creatinine. 4. The difference of urinary BAA by EEA exposure level was significant and the correlation coefficient between urinary BAA and EEA in air was the highest showing 0. 53O(p < 0.01). In conclusion, the amount of urianry EAA proved to be a good parameter for biological monitoring of workers exposed to EEA.


Assuntos
Absorção , Consumo de Bebidas Alcoólicas , Creatinina , Monitoramento Ambiental , Ocupações , Pintura , Pinturas , Respiração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA