1.
Chinese Journal of Medical Instrumentation ; (6): 96-98, 2022.
Artigo em Chinês | WPRIM | ID: wpr-928866

RESUMO

Bacterial endotoxin is considered as one of the critical risk factors in medical devices, especially implanted devices that directly or indirectly contact with blood circulating system. In that case, endotoxin limits for implanted medical devices is important in determine the safety of medical devices. According to GB/T 14233.2-2005, the requirements of endotoxin index for intrathoracic medical devices is 2.15 EU per device. However, the definition of "intrathoracic medical devices" is vague. Specifically, "for cardiovascular system application" instead of "intrathoracic application" is more reasonable. With the deeper understanding of the risk of endotoxin in medical devices and considering the internationally accepted standards, the limits of endotoxin in medical devices for cardiovascular system application is acceptable at 20 EU per device.


Assuntos
Endotoxinas
2.
Chinese Pharmacological Bulletin ; (12): 944-948, 2022.
Artigo em Chinês | WPRIM | ID: wpr-1014095

RESUMO

Aim To establish a batch of endotoxin standard for baeterial endotoxin detection of insoluble samples.Methods Candidate A and candidate B were prepared by freeze -drying bacterial endotoxin without excipient.The two batches of candidates were calibrated by three methods, including 13 laboratories for gel method, 9 laboratories for kinetic-turbidimetric assay and 5 laboratories for kinetic chromogenic assay.Results After statistical analysis, the geometric mean values of gel method, kinetic-turbidimetric assay and kinetic chromogenic assay calibration of candidate A were 680.1 EU, 827.0 EU and 800.8 EU, with RSD of 22.4%, 16.2% and 16.7%, respectively.The P value of variance analysis of calibration results of the three methods was 0.067, showing no significant difference.The weighted mean of potency was 774.0 EU (95% confidence interval 721.0 - 831.0, FL% 7.10).The geometric mean values of the calibration of candidate B by gel method, kinetic-turbidimetric assay and kinetic chromogenic assay method were 1 640.6 EU, 1 828.6 EU and 3 224.8 EU, with RSD of 33.9% , 47.0% and 54.4% , respectively.The P val¬ue of variance analysis of the calibration results of the three methods was 0.030, showing significant differ¬ence.Chi-square test was used to correct the weight of each method , and weighted average of the results of the three methods was used to obtain a corrected weighted average efficiency value of 1 822.7 EU (95% confi¬dence interval 1 548.7 -2 145.2, FL% 16.4).Can¬didate B was eliminated based on the results.Conclu¬sion Candidate A has become the first batch of na¬tional standard bacterial endotoxin (for insoluble sam¬ples only) approved by National Standard Substance Committee of China, and the potency is 700 EU.

3.
Chinese Pharmacological Bulletin ; (12): 1110-1113, 2022.
Artigo em Chinês | WPRIM | ID: wpr-1014071

RESUMO

Aim To explore the feasibility of the micro- dynamic chromogenic method for quantitative detection of bacterial endotoxin in recombinant novel coronavirus vaccine ( CHO cell).Methods The micro-dynamic color method of Limulus reagent was used to establish a bacterial endotoxin standard curve.The dilution factor was determined through interference pre -experiment, the recoverv rate of the endotoxin added to the test so- J lution was determined, and the interference test to complete the quantitative detection test of the bacterial endotoxin content in the test product was performed, and the results were compared with those of the gel-clot method.Results Hie linear range of the concentration of the standard curve was 0.02 to 2.0 EU • mL 1 , and the regression equation of the standard curve was lgT =-0.302 7 lgC +2.858 7( r = 0.998 9).When recombinant novel coronavirus vaccine ( CHO cell) was cliluted 40 times or below, the micro -dynamic chromogenic reagent did not interfere with the bacterial endotoxin agglutination reaction, and the recovery rate was 50% to 200%.The test results were consistent with the gel- clot method.Conclusions The micro-dynamic chromogenic method can be used for the quantitative detection of bacterial endotoxins in recombinant novel coronavirus vaccine ( CHO cell) with accurate results, high sensitivity, and process monitoring.

4.
Chinese Pharmacological Bulletin ; (12): 1107-1110, 2022.
Artigo em Chinês | WPRIM | ID: wpr-1014070

RESUMO

Aim To evaluate the equivalence between micro kinetic chromogenic assay anrl kinetic chromogenic assay in order to provide data support for the use of alternative methods.Methods Detection conditions; micro kinetic chromogenic assay and kinetic chromogenic assay limulus reagent were used, sample amount of each well and limulus reagent was 25 jxL ( kinetic chromogenic assay was 100 jxL) , detection wavelength was 405 nm, ONSET OD value was 0.03, and half- well elisa plate was used for detection ( kinetic chromogenic assay was ordinary ELISA plate).The equivalence of the two methods was evaluated by various statistical methods, such as equivalence test, in collaboration with four laboratories in China.Results The results of one-way an OVA, paired T test and equivalence test were consistent, indicating that there were some differences between the existing kinetic chromogenic assay of different manufacturers, while there was no significant difference between the trace or conventional amount of reagent used by each manufacturer.Conclusions Micro kinetic chromogenic assay is e- quivalent to existing reagents in terms of accuracy and recoverv.J.

5.
Chinese Pharmacological Bulletin ; (12): 1227-1230, 2022.
Artigo em Chinês | WPRIM | ID: wpr-1014038

RESUMO

Abstract; Aim To solve the problems in the appliea- tion of egg yolk leeithin endotoxin test method, and and to establish the baeterial endotoxin examination method for egg yolk lecithin (for injeetion). Methods The ethanol solution of Tween 80 ( the volume ratio of tween 80 to anhydrous ethanol was 2. 5 • 2. 7, mixed for 4 min) was used to prepare lecithin solution of egg yolk at 0. 1 kg • L 1 , and 10 test water was added to 1 mL lecithin solution of egg yolk (500 EU • mL 1 standard solution of endotoxin IOjxL was added for pos¬itive control). After diluted 20 times with endotoxin test water, the standard curve range was 10 ~0. 01 EU • mL 1 by kinetic-turbidimetrie assay. Methodology of endotoxin test was studied using limulus lysate from two manufacturers and eight hatches of samples. Results The recoveries of eight hatches of samples all met the requirement of interference test between 50% and 200% stipulated in the pharmacopoeia, which solved the problems of the current endotoxin test method in practical application. Conclusions The bacterial en¬dotoxin test method of egg yolk lecithin with good dura-bility is established to provide the basis for the revision of pharmacopoeia.

6.
Chinese Pharmacological Bulletin ; (12): 1717-1722, 2022.
Artigo em Chinês | WPRIM | ID: wpr-1013995

RESUMO

Aim To design and implement the bacteri¬al endotoxin test proficiency testing plan to evaluate the laboratory's ability and level to determine bacterial en¬dotoxin. Methods According to the Chinese Pharma-copoeia (2015 edition, Vol IV) -1143 Bacterial Endo¬toxin Test-Photometric Method ( Method 2 ) , each la¬boratory used any of these methods to determine the endotoxin content of the sample to be tested. The stati- stical software JMP13 was used for statistical analysis of the feedback results of the participating laboratories. The consensus value of the participants, namely the ro¬bust average value of the effective test results of all the participating laboratories, was used as the assigned value X of the endotoxin content of the samples to be tested in the proficiency testing of the round. The re¬sults of participating laboratories were evaluated ac¬cording to the following criteria: (1) the laboratory test results were within 50% to 200% of the assigned value of the sample, which was evaluated satisfactory; ( 2 ) the laboratory test results were not within the 50 -200% range of the assigned value of the sample, which was evaluated dissatisfactory. Results A total of laboratories participated in this capacity verification plan, with 45 in the laboratory with satisfactory re¬sults, with a satisfaction of 91. 8% ; There were 4 la¬boratories that received "dissatisfaction" results, all of which were not within the range of 50% -200% of the assigned value of samples, and the dissatisfaction of 8. 2% . Conclusions Most of the participating labora¬tories can accurately detect the bacterial endotoxin con¬tent in the sample to be tested, indicating that the level of bacterial endotoxin detection in our country is gener¬ally good at present.

7.
Acta Pharmaceutica Sinica ; (12): 1836-1840, 2020.
Artigo em Chinês | WPRIM | ID: wpr-825157

RESUMO

This paper mainly studied the effect of Xiyanping injection on the bacterial endotoxin lipopolysaccharide (LPS)-induced fever in rabbits, preliminarily investigated the mechanisms, and provided pharmacological basis for the clinical application. The rabbit model of endotoxin-induced fever was established by using LPS as the inducer; The changes of rectal temperature were measured; The levels of prostaglandin E2 (PGE2), tumor necrosis factor-α (TNF-α), interleukin-1β (IL-1β), and phospholipaseA2 (PLA2) in the serum were measured; The levels of PGE2, cyclic adenosine monophosphate (cAMP), and arginine vasopressin (AVP) in cerebrospinal fluid as well as hypothalamus were detected. The animal welfare and experimental process are in accordance with the regulations of the Animal Ethics Committee of China Pharmaceutical University in this study. The results showed that Xiyanping injection (12.5, 25, and 50 mg·kg-1) could significantly reduce LPS-upregulated body temperature of rabbits, and the duration of action could reach 5.5-8.5 h. At the doses of 25 and 50 mg·kg-1, the antipyretic effect of Xiyanping injection was comparable to that of analgin injection (50 mg·kg-1). Furthermore, Xiyanping injection and analgin injection both reduced the levels of PGE2, IL-1β, TNF-α, and PLA2 in the serum of febrile rabbits to the varying degrees. In addition, Xiyanping injection also down-regulated the levels of PGE2, cAMP, and AVP in the hypothalamus, and PGE2 and cAMP in the cerebrospinal fluid. The level of AVP in the cerebrospinal fluid was up-regulated. This study indicated that Xiyanping injection could significantly improve the endotoxin-induced fever in rabbits, and mechanisms were closely related to the regulation of the levels of PGE2, TNF-α, IL-1β, PLA2, cAMP, and AVP in serum, hypothalamus, and cerebrospinal fluid.

8.
São Paulo; s.n; s.n; 2019. 109 p. graf, tab.
Tese em Português | LILACS | ID: biblio-1022813

RESUMO

A fim de garantir a qualidade final de produtos os laboratórios de análise microbiológica fornecem dados sobre a qualidade dos mesmos em todas as suas etapas de produção. A crescente preocupação com a saúde dos pacientes conduz à busca de métodos que forneçam resultados precisos e rápidos, pois possibilitam que ações corretivas sejam tomadas em tempo real. O presente trabalho teve por objetivo avaliar o potencial de tecnologia alternativa no monitoramento de endotoxina bacteriana na água tratada para diálise e dialisato e avaliar o potencial da citometria de fluxo na análise de água. Para isso utilizou-se Portable Test System (PTS®) como método alternativo para detecção de endotoxina bacteriana no monitoramento da água tratada para diálise e dialisato, o qual foi validado frente ao método convencional farmacopeico. Paralelamente realizou-se revisão narrativa da literatura a fim de avaliar a aplicabilidade da citometria de fluxo em análises de água. A análise dos diferentes parâmetros de validação para endotoxina bacteriana no método alternativo mostrou que, exceto para a menor diluição analisada, houve linearidade e precisão nos resultados. Por outro lado a concentração de 0,25 UE/mL foi a menor que apresentou exatidão e especificidade. Observou-se ainda, que o limite de detecção foi de 0,125UE/mL e o de quantificação de 0,25 UE/mL, portanto o intervalo foi de 0,25-1,0 UE/mL. Adicionalmente pela análise de resistência pode-se perceber que ao variar analistas não houve diferença significativa. Em relação ao tempo de análise em uma condição de rotina laboratorial com muitas amostras, o PTS® mostrou-se demorado. Ressalta ainda, que seria importante que a legislação vigente determinasse a análise mensal de endotoxinas no dialisato. A revisão da literatura evidencia o potencial da tecnologia de citometria de fluxo, pois a mesma mostrou-se satisfatória quando comparada a metodologias convencionais para análise de água. O trabalho desenvolvido permitiu concluir que o PTS®) mostrou-se adequado para analisar amostras in loco, permitindo análises em tempo real, que para as quais haja a expectativa de ausência de endotoxinas ou de concentração respeitando o intervalo de 0,25 UE/mL a 1,0 UE/mL. Quanto a citometria de fluxo, esta mostrou-se uma tecnologia promissora em analisar amostras de água, sendo portanto recomendável proceder a estudos de validação e aplicabilidade


In order to guarantee the final quality of products, the microbiological analysis laboratories provide data about their quality at all production stages. The growing concern for patients' health leads to the search for methods that provide accurate and fast results, as they enable corrective actions to be taken in real time. The present work aimed to evaluate the alternative technology potential in the monitoring of bacterial endotoxin in treated water for dialysis and dialysate and to evaluate the potential of flow cytometry in water analysis. The different validation parameters analysis for bacterial endotoxin in alternative method showed that, except for the lowest dilution analyzed, there was linearity and precision in the results. On the other hand, the concentration of 0.25 EU / mL was the lowest that presented accuracy and specificity. It was further observed that the detection limit was 0.125UE / mL and the quantification limit was 0.25 EU / mL, so the range was 0.25-1.0 EU / mL. Additionally by the ruggedness analysis it was possible to perceived that when varying analysts there was no significant difference. Regarding the analysis time in a laboratory routine condition with many samples, the PTS® was was time consuming. It was also observed that it would be important to determine monthly analysis of endotoxins in dialysate. The literature review evidence the flow cytometry technology potential of the because it was satisfactory when compared to conventional methodologies for water analysis. The research showed that the PTS® was suitable for analyzing samples in loco, allowing real-time analyzes, for which there is expectation of endotoxins absence or concentration respecting the range of 0.25 EU / mL to 1.0 EU / mL. For the flow cytometry, it was shown to be a promising technology for analyzing water samples, and it is therefore advisable to carry out validation and applicability studies


Assuntos
/classificação , Diálise Renal , Diálise , Endotoxinas/análise , Citometria de Fluxo/instrumentação
9.
Chinese Pharmaceutical Journal ; (24): 1888-1894, 2019.
Artigo em Chinês | WPRIM | ID: wpr-857858

RESUMO

OBJECTIVE: To remove bacterial endotoxin from glycyrrhizic acid for injection by ultrasonic-assisted ultrafiltration technology. METHODS: On the basis of clarifying the influences of molecular weight cut off, ultrasonic power, glycyrrhizic acid concentration and pH,the ultrafiltration transmittance of glycyrrhizic acid and the rejection of bacterial endotoxin were selected as indexes to optimize the parameters for ultrasonic-assisted ultrafiltration. RESULTS: The impact of glycyrrhizic acid concentration was relatively low. The optimal separation conditions were as following: molecular weight cut off 10×103, ultrasonic power 300 W and pH 7.7. The predicted value of the ultrafiltration rejection of bacterial endotoxin was 93.7%, meanwhile the transmittance of glycyrrhizic acid was 92.2%, which was close to the model-predictive value. CONCLUSION: This mathematical model has good regression with high fitting degree, and can solve the separation contradiction between glycyrrhizic acid and bacterial endotoxin. This study provides scientific data for the purification of pharmaceutics in which saponins are the main components.

10.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 196-203, 2019.
Artigo em Chinês | WPRIM | ID: wpr-802052

RESUMO

Endometriosis is a multiple disease that afflicts the health of women at childbearing age,and its incidence rate has been increasing year by year,furthermore,there has been a trend to be younger.At present,the pathogenesis of endometriosis has been not expounded completely,its cure rate is not high with high recurrence rate.In recent years,studies have shown that the human is a commensal body composed of a large number of microorganisms,and especially the microorganisms in the intestinal are closely related to the health of the body.Based on the previous studies on endometriosis,this paper proposes that its pathogenesis may be related to intestinal microbiological disorder,and aims to provide new ideas for the treatment of endometriosis.

11.
Asian Pacific Journal of Tropical Medicine ; (12): 48-52, 2018.
Artigo em Chinês | WPRIM | ID: wpr-972501

RESUMO

Objective: To investigate the effects of a dry aqueous extract of Notobasis syriaca (N. syriaca) on lipopolysaccharide (LPS)-induced inflammation in rats. Methods: Rats were fed the dried extract [500 mg/(kg•d)] for three consecutive days and then were intraperitoneally injected with LPS (1 mg/kg). Two hours after LPS injection, rats were sacrificed and blood and brain regions were collected. Inflammatory mediators' levels in plasma and homogenates of brain regions were determined by ELISA. Results: Pretreatment with the N. syriaca extract resulted in significant anti-inflammatory effects (P<0.05), including: i) attenuated LPS-induced hypothermia; ii) decreased hypothalamus and hippocampus prostaglandin E2 levels in the LPStreated rats; and, iii) reduced hypothalamus and hippocampus interleukin-6 and tumor necrosis factor-levels in the LPS-treated rats. Conclusions: These results suggest that N. syriaca possesses anti-inflammatory properties. Thus, it is possible that long-term consumption of this plant may result in beneficial pharmacological effects.

12.
Asian Pacific Journal of Tropical Medicine ; (12): 48-52, 2018.
Artigo em Inglês | WPRIM | ID: wpr-825813

RESUMO

Objective:To investigate the effects of a dry aqueous extract of Notobasis syriaca (N. syriaca) on lipopolysaccharide (LPS)-induced inflammation in rats.Methods:Rats were fed the dried extract [500 mg/(kgod)] for three consecutive days and then were intraperitoneally injected with LPS (1 mg/kg). Two hours after LPS injection, rats were sacrificed and blood and brain regions were collected. Inflammatory mediators’ levels in plasma and homogenates of brain regions were determined by ELISA.Results:Pretreatment with the N. syriaca extract resulted in significant anti-inflammatory effects (P<0.05), including: i) attenuated LPS-induced hypothermia; ii) decreased hypothalamus and hippocampus prostaglandin EConclusions:These results suggest that N. syriaca possesses anti-inflammatory properties. Thus, it is possible that long-term consumption of this plant may result in beneficial pharmacological effects.

13.
China Pharmacist ; (12): 365-368, 2018.
Artigo em Chinês | WPRIM | ID: wpr-705535

RESUMO

Objective:To establish the bacterial endotoxin test for HSSYO-001-3S. Methods: HSSYO-001-3S was dissolved in dimethylsulfoxide,diluted by BET water and centrifuged,and then the supernatant was used for the bacterial endotoxin test. The ex-periment was carried out according to the gel-clot technique for bacterial endotoxin inspection and the related regulations in Chinese Pharmacopoeia (2015 edition,volumeⅣ,general rule 1443). Results:HSSYO-001-3S was added with cosolvent and diluted by BET water to 1 mg·ml-1,and there was no interference effects to bacterial endotoxin test from the supernatant diluted four times or more. Conclusion:Bacterial endotoxin test can be used to control the quality of HSSYO-001-3S.

14.
China Pharmacist ; (12): 583-586, 2017.
Artigo em Chinês | WPRIM | ID: wpr-510064

RESUMO

Objective:To establish a bacterial endotoxin test for safflower yellow for injection to control the drug quality and reduce the incidence of clinical pyrogenic reaction. Methods:The bacterial endotoxin test was carried out according to the methods and guid-ing principles in Chinese Pharmacopoeia ( 2015 edition, volumeⅣ) . A systematic study was carried out to investigate the interference of safflower yellow for injection with limulus reagent and agglutination reaction to bacterial endotoxin in order to detect the non-interfer-ence concentration of bacterial endotoxin. Results: Safflower yellow for injection with the concentration below or equal to 0. 4 mg· ml-1 had no interference with tachypiens amebocyte lysate. Conclusion: Bacterial endotoxin test ( gel method) can be used for the limit test of bacterial endotoxin of safflower yellow for injection, and the results are accurate and reproducible.

15.
China Pharmacy ; (12): 2576-2578, 2017.
Artigo em Chinês | WPRIM | ID: wpr-619855

RESUMO

OBJECTIVE:To adopt gel method for the determination of bacterial endotoxin in Fat emulsion(10%)/amino acid (15)/glucose (20%) injection. METHODS:According to the gel method in term ofbacterial endotoxin test methodin Chinese Pharmacopeia(2015 edition),the maximal valid dilution(MVD)of samples were determined through interference test and the vali-dated. The results were compared with chromogenic method. RESULTS:In gel method,the interference to agglutination reaction of TAL and bacterial endotoxin can be excluded when samples were diluted 24 times or less. In chromogenic method,the samples should be diluted 76 times or less. CONCLUSIONS:Gel method can be used for bacterial endotoxin test of Fat emulsion(10%)/amino acid(15)/glucose(20%)injection.

16.
China Pharmacist ; (12): 1208-1211, 2016.
Artigo em Chinês | WPRIM | ID: wpr-494959

RESUMO

Objective:To establish the bacterial endotoxin test method and the abnormal toxicity test method for reduced glutathi -one for injection.Methods:According to the requirements and methods in Chinese Pharmacopoeia (2015 edition, part IV), the bacte-rial endotoxin test and the abnormal toxicity test for reduced glutathione were studied .Results:The limit of bacterial endotoxin for re-duced glutathione was 0.125 EU· mg-1 , and the limit of abnormal toxicity was 1.0 g· kg-1 .Conclusion: The bacterial endotoxin test method and the abnormal toxicity test method are feasible .The abnormal toxicity should be supplemented in the quality standard for reduced glutathione , and the bacterial endotoxin test can replace the pyrogen test .

17.
China Pharmacist ; (12): 384-386,387, 2016.
Artigo em Chinês | WPRIM | ID: wpr-603470

RESUMO

Objective:To establish a method to determine the content of bacterial endotoxin in iodixanol. Methods:The standard curve of kinetic turbidimetric method was established and the dilution ratio was optimized by interference test. Bacterial endotoxin in the samples was determined. Results:The dilution ratio of 1 ∶12 did not interfere with the test. The recovery rate of bacterial endotox-in was 50%-200%. Conclusion:The kinetic turbidimetric method is suitable for the determination of bacterial endotoxin in iodixanol.

18.
China Pharmacy ; (12): 2999-3000, 2015.
Artigo em Chinês | WPRIM | ID: wpr-500790

RESUMO

OBJECTIVE:To establish a method for the bacterial endotoxin test of vinpocetine raw material. METHODS:Ac-cording to the bacterial endotoxin test in the Chinese Pharmacopoeia(2010 edition,Ⅱ)Appendix Ⅺ E,the samples with different batches were used for interference test and bacterial endotoxin test by tachypleus amebocyte lysate from 2 manufacturers. RE-SULTS:The vinpocetine solutions with high concentration have interference effect on the agglutination reaction of bacterial endotox-in and the interference can be eliminated by diluting. CONCLUSIONS:The non-interference concentration of vinpocetine solutions is 0.25 mg/ml. Bacterial endotoxin test can be used to control the quality.

19.
Chinese Pharmaceutical Journal ; (24): 1251-1254, 2015.
Artigo em Chinês | WPRIM | ID: wpr-859567

RESUMO

OBJECTIVE: To summarize and analyze the factors of building the bacterial endotoxin test laboratory. These factors should meet the GPCL quality management concepts. METHODS: Give Some specific methods and experience in five aspects were given, which combine the GPCL quality management concepts with the characteristics of bacterial endotoxin test. RESULTS AND CONCLUSION: Summarizes The applications of GPCL concept for bacterial endotoxin test laboratory is summarized.

20.
China Pharmacist ; (12): 2010-2012, 2015.
Artigo em Chinês | WPRIM | ID: wpr-670098

RESUMO

Objective:To establish bacterial endotoxin test for brozopine. Methods: Interference pre-test and interfering factors test were conduced on 3 batches of samples from 2 manufacturers to confirm the applicability of bacterial endotoxin test and the non-in-terfering concentration. The bacterial endotoxin test was carried out based on the method described in the second part of Chinese Phar-macopeia (2010 edition) and relevant standards and guidelines. Results: The three batches of brozopine showed no interference in bacterial endotoxin test at the concentration less than or equal to 2. 5 mg·ml-1 . The bacterial endotoxin test of the three bathes of samples all met the requirements. Conclusion:Bacterial endotoxin test can be used for the quality control of brozopine.