Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Artigo em Chinês | WPRIM | ID: wpr-1031886

RESUMO

ObjectiveTo construct a quantitative prediction model of three indicators(moisture absorption rate, film thickness and coating weight gain) during the coating process of Vitamin C Yinqiao tablets(VCYT) by near-infrared spectroscopy(NIRS), and to realize the endpoint judgment. MethodReal-time NIRS data of 4 batches of VCYT during the coating process were collected by diffuse reflection method. The coating method employed was the rolling coating method, and the samples were obtained at the spray stage from the coater's sampling port every 10 minutes, and 57 batches of samples(about 1 800 tablets) were collected at various coating times, the tablets were embedded in molten paraffin, cut longitudinally, and observed by stereomicroscope. The film thickness, with a target value of 38 μm, was then measured using Motic Images Advanced 3.2 software. Furthermore, the mositure absorption rate of samples, aiming for a target value of 3%, was determined in accordance with guiding principles for drug hygroscopicity testing in the 2020 edition of Chinese Pharmacopoeia, and 3 samples were randomly selected from each batch(10 tablets per batch), and the coating weight gain was calculated(target value of 4%). Partial least squares regression(PLSR) was used to construct a quantitative model of the 3 coating indicators, and the predicted values of the coating indicators were smoothed using the moving average method and used to determine the coating endpoints. ResultThe prediction determination coefficients(Rp2) for moisture absorption rate, film thickness and coating weight gain were 0.933 4, 0.932 6 and 0.965 9, the root mean square errors of prediction(RMSEP) were 0.163 5%, 1.870 9 μm and 0.240 3%, the relative percent deviations(RPD) were 3.711 0, 2.760 7 and 5.415 8, respectively. The results of the external validation set demonstrated that the real-time predicted values obtained by the models exhibited the same trend as the measured values, and the coating endpoint could be accurately predicted(with a prediction error of less than 7.32 min and a relative error of less than 5.63%). ConclusionThe established NIRS model exhibits excellent predictive performance and can be used for quality control of VCYT during the coating process.

2.
Artigo em Chinês | WPRIM | ID: wpr-862702

RESUMO

<b>Objective::To investigate the feasibility of near-infrared spectroscopy for detecting the coating film thickness of Tianshu tablets. <b>Method::Nine batches of Tianshu tablets were taken during the coating process. Then, their near-infrared diffuse reflection spectra were collected. The sample set was divided into calibration set and validation set by Kennard-Stone algorithm. The preprocessing method was selected. The synergy interval partial least squares (siPLS) and moving window partial least squares (mwPLS) were employed to screen the optimal spectral interval. And the corresponding quantitative calibration model of partial least squares (PLS) were established. Some evaluation parameters were adopted to assess the performance of the model. <b>Result::The method of first derivative and Norris Derivative smoothing combined with standard normal variate transformation was suitable for processing the spectra. The optimal PLS model was established in the preferred band interval of siPLS. The correlation coefficient between the predicted value and the measured value of calibration set was 0.966, and the correlation coefficient between the predicted value and the measured value of validation set was 0.991.Both root mean square error of calibration (RMSEC) and root mean square error of prediction (RMSEP) values were small, which showed the fitness and predictive performance of the model were favorable. <b>Conclusion::The near-infrared spectroscopy technique can be used to determine coating film thickness of Tianshu tablets with high accuracy, which provides technical supports for the in-line determination of coating thickness in the production process of traditional Chinese medicine tablets.

3.
China Pharmacist ; (12): 2244-2248, 2017.
Artigo em Chinês | WPRIM | ID: wpr-664093

RESUMO

Objective:To prepare Shengmai pulse controlled release dropping pills and investigate the in vitro release. Methods:Shengmai dropping pills were placed in a fluidized bed and coated respectively with an aqueous solution of a swelling layer ( containing croscarmellose sodium) and a controlled release layer ( containing ethylcellulose aqueous dispersion) . The effects of different coating weight gain on the drug release from the swelling layer and the controlled release layer were studied by central composite design-re-sponse surface methodology and in vitro dissolution test. Results:The weight gain of the swelling layer and the controlled release layer was 20% and 10%, respectively, and the expected release time was 4 h. Conclusion:By adjusting the coating weight gain, the drop-ping pills with different release time can be obtained.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA