Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 379
Filtrar
1.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 62-68, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1009110

RESUMO

OBJECTIVE@#To investigate the clinical application of high-frequency color Doppler ultrasound (HFCDU) in detecting perforators in the deep adipose layers for harvesting super-thin anterolateral thigh flap (ALTF).@*METHODS@#Between August 2019 and January 2023, 45 patients (46 sides) with skin and soft tissue defects in the foot and ankle were treated, including 29 males and 16 females, aged from 22 to 62 years, with an average of 46.7 years. The body mass index ranged from 19.6 to 36.2 kg/m 2, with an average of 23.62 kg/m 2. The causes of injury included traffic accident injury in 15 cases, heavy object crush injury in 20 cases, mechanical injury in 8 cases, heat crush injury in 1 case, and chronic infection in 1 case. There were 20 cases on the left side, 24 cases on the right side, and 1 case on both sides. After thorough debridement, the wound size ranged from 5 cm×4 cm to 17 cm×11 cm. All patients underwent free super-thin ALTF transplantation repair. HFCDU was used to detect the location of the perforators piercing the deep and superficial fascia, as well as the direction and branches of the perforators within the deep adipose layers before operation. According to the preoperative HFCDU findings, the dimensions of the super-thin ALTF ranged from 6 cm×4 cm to 18 cm×12 cm. The donor sites of the flaps were directly sutured.@*RESULTS@#A total of 55 perforators were detected by HFCDU before operation, but 1 was not found during operation. During operation, a total of 56 perforators were found, and 2 perforators were not detected by HFCDU. The positive predictive value of HFCDU for identifying perforator vessels was 98.2%, and the sensitivity was 96.4%. Among the 54 perforators accurately located by HFCDU, the orientation of the perforators in the deep adipose layers was confirmed during operation. There were 21 perforators (38.9%) traveled laterally and inferiorly, 12 (22.2%) traveled medially and inferiorly, 14 (25.9%) traveled laterally and superiorly, 5 (9.3%) traveled medially and superiorly, and 2 (3.7%) ran almost vertically to the body surface. Among the 54 perforators accurately located by HFCDU, 35 were identified as type 1 perforators and 12 as type 2 perforators (HFCDU misidentified 7 type 2 perforators as type 1 perforators). The sensitivity of HFCDU in identifying type 1 perforators was 100%, with a positive predictive value of 83.3%. For type 2 perforators, the sensitivity was 63.2%, and the positive predictive value was 100%. The surgeries were successfully completed. The super-thin ALTF had a thickness ranging from 2 to 6 mm, with an average of 3.56 mm. All super-thin ALTF survived, however, 1 flap experienced a venous crisis at 1 day after operation, but it survived after emergency exploration and re-anastomosis of the veins; 1 flap developed venous crisis at 3 days after operation but survived after bleeding with several small incisions; 3 flaps had necrosis at the distal edge of the epidermis, which healed after undergoing dressing changes. All 45 patients were followed up 6-18 months (mean, 13.6 months). Three flaps required secondary defatting procedures, while the rest had the appropriate thickness, and the overall appearance was satisfactory.@*CONCLUSION@#Preoperative application of HFCDU to detect the perforator in the deep adipose layers can improve the success and safety of the procedure by facilitating the harvest of super-thin ALTF.


Assuntos
Masculino , Feminino , Humanos , Coxa da Perna/cirurgia , Procedimentos de Cirurgia Plástica , Estudos Prospectivos , Transplante de Pele , Retalhos de Tecido Biológico , Queimaduras , Lesões dos Tecidos Moles/cirurgia , Ultrassonografia Doppler em Cores , Lesões por Esmagamento/cirurgia , Retalho Perfurante , Resultado do Tratamento
2.
Kinesiologia ; 42(4): 275-284, 20231215.
Artigo em Espanhol, Inglês | LILACS-Express | LILACS | ID: biblio-1552535

RESUMO

Introducción. La ventilación de alta frecuencia (VAF) es utilizada en pacientes graves neonatales con un uso cercano al 10% del total de usuarios en ventilación mecánica (VM). Actualmente estos equipos miden volumen corriente de manera precisa, continua y rutinaria, sin embargo no hay estimaciones del comportamiento mecánico del sistema respiratorio del usuario, como lo es la distensibilidad toracopulmonar, durante el ciclo ventilatorio que sean reportadas por las pantallas de los equipos. Objetivo. Estimar distensibilidad dinámica toracopulmonar en modelos neonatales de VAF. Métodos. Estudio cuantitativo, observacional, descriptivo, y "wench work", donde se midió distensibilidad en VM convencional y volumen corriente (Vt) en VAF con equipo Acutronics Fabian® por 4 evaluadores independientes, en 5 tipos de pulmón de ensayo y bajo diferentes escenarios de parámetros de VAF con ajustes de presión media de la vía aérea (PMVA), amplitud, frecuencia respiratoria, tiempo inspiratorio, volumen garantizado, y tipo de circuito. Mediante suavización de regresiones locales por estimación mínima cuadrática (LOWESS) y análisis de regresión multivariada se obtuvieron los valores asociados a distensibilidad, con los que se construyeron ecuaciones de estimación de distensibilidad en VAF. Resultados. Se realizaron en total 46080 mediciones, con correlación intra e interevaluador > 0.99. La distensibilidad mediana (percentil 25; 75) de los 5 modelos pulmonares fue de 0.455 (0.3; 0.98). Se asociaron a distensibilidad, mediante modelos de regresión lineal múltiple de manera significativa, todas las variables evaluadas, salvo PMVA. Se establecieron asociaciones multivariantes crudas (R2=.311), de distensibilidad predicha por LOWESS (R2=.744) y distensibilidad predicha y variables independientes predichas por regresión lineal simple (R2=.973). Conclusiones. La distensibilidad en VAF esta determinada en pulmones de ensayos por los parámetros programados de: tipo de circuito, uso de volumen garantizado, tiempo inspiratorio, frecuencia respiratoria y amplitud, además del Vt medido. Se reporta ecuación explicativa de distensibilidad en VAF.


Background. Background: High frequency mechanical ventilation (HFV) is used in severe neonatal subjects nearly 10% of total mechanically ventilated (MV) users. Currently, this MV's mode allow to measure tidal volumen in an accurately, continuous and routinarie way in HFV, however there are non estimation to assess mechanical behavior of respiratory system during ventilatory cycle, like thoraco-pulmonary compliance, who be report in the equipment display. Objetive. To estimate thoraco-pulmonary compliance in artificial neonatal lung models in HFV. Methods. Quantitative, observational, descriptive, and wench work study, where distensibility was measured in conventional MV and tidal volume (TV) in HFV with Acutronics Fabian® equipment by 4 independent evaluators, in 5 types of test lung and under different scenarios of HFV parameters with adjustments of mean airway pressure (MAP), amplitude, respiratory rate, inspiratory time, guaranteed volume, and type of circuit. By smoothing local regressions by least quadratic estimation (LOWESS) and multivariate regression analysis, the values associated with distensibility were obtained, with this measures, equations for estimating compliance in VAF were constructed. Results. A total of 46080 measurements were made, with intra and inter-evaluator correlation coefficent > 0.99. The median compliance (25th percentile; 75) of the 5 lung models was 0.455 (0.3; 0.98). All variables evaluated, except MAP, were associated with compliance, by means of multiple linear regression models. Crude multivariate associations (R2 = .311), predicted compliance by LOWESS (R2 = .744) and predicted compliance and independent variables predicted by simple linear regression (R2 = .973) were established to estimate thoraco-pulmonary compliance. Conclusions. Compliance in VAF is determined in test lungs by the programmed parameters of: type of circuit, use of guaranteed volume, inspiratory time, respiratory frequency and amplitude, in addition to the measured Vt. An explanatory equation for distensibility in VAF is reported.

3.
Chinese Journal of Dermatology ; (12): 540-544, 2023.
Artigo em Chinês | WPRIM | ID: wpr-994510

RESUMO

Objective:To investigate imaging characteristics of papulopustular rosacea (PPR) by high-frequency ultrasound combined with color Doppler flow imaging.Methods:From August 2021 to August 2022, 30 patients with PPR were enrolled from the Department of Dermatology, the First Affiliated Hospital of Baotou Medical College in the Inner Mongolia Autonomous Region, and 30 healthy volunteers served as controls. The 22-MHz high-frequency ultrasound combined with color Doppler blood flow imaging was performed to measure the skin thickness, echo and blood flow parameters at the cheek, and the ultrasound results were compared between the two groups. Comparisons between groups were conducted by using t test or chi-square test. The diagnostic value was analyzed using the area under the curve (AUC) in the receiver operating characteristic (ROC) curve. Results:In the case group, there were 12 males and 18 females, and their ages ranged from 22 to 65 years (42.3 ± 12.8 years) ; in the control group, there were 10 males and 20 females, and their ages ranged from 24 to 62 years (41.0 ± 8.4 years) . The epidermal and dermal thicknesses at the cheek were significantly higher in the case group (132.64 ± 12.29 μm, 1 812.29 ± 85.52 μm, respectively) than in the control group (104.34 ± 14.45 μm, 1 671.77 ± 146.55 μm, respectively, both P < 0.05) . High-frequency ultrasound images showed that the case group was mainly characterized by irregular hypoechoic areas in the cheek dermis (80%) , while banded moderately echoic areas were common in the cheek dermis in the control group (90%) ; subepidermal low-echogenic bands and dermal irregular hypoechoic areas were more likely to appear in the case group than in the control group (93.33% vs. 43.33%, 80% vs. 10%, respectively, both P < 0.001) . Compared with the control group, the case group showed a significantly increased proportion of patients with abundant blood flow signals (93.3% vs. 10%, P < 0.05) , and significantly increased blood vessel diameters (1.60 ± 0.42 mm vs. 0.95 ± 0.32 mm, P < 0.05) ; there was no significant difference in peak systolic blood flow velocity and vascular resistance index between the two groups (both P > 0.05) . The AUC of high-frequency ultrasound combined with color Doppler flow imaging quantitative parameters (including epidermal thicknesses, dermal thicknesses, and blood vessel diameters) was 0.989 (95% CI: 0.970 - 1.000) for the diagnosis of PPR, and the sensitivity and specificity were both 96.7%, which were higher than those of single parameter-based diagnostic model. Conclusion:High-frequency ultrasound combined with color Doppler flow imaging can help improve the accuracy of the diagnosis of PPR, by accurately and non-invasively measuring skin thickness and blood flow parameters.

4.
Chinese Journal of Dermatology ; (12): 434-438, 2023.
Artigo em Chinês | WPRIM | ID: wpr-994495

RESUMO

Objective:To measure the skin thickness in patients with erysipelas by high-frequency ultrasonography (HF-USG), and to compare the clinical efficacy of systemic antibiotics alone versus their combination with glucocorticoids in the treatment of erysipelas.Methods:Hospitalized patients with erysipelas were enrolled from Zhongda Hospital, Southeast University from January to December in 2021, and randomly divided into the study group and control group according to the order of visits. The study group was treated with systemic cefathiamidine for 7 days followed by oral methylprednisolone at a dose of 0.4 mg·kg -1·d -1, while the control group was treated with cefathiamidine alone. Before and after the treatment for 10 days, the thicknesses of the epidermis-dermis layers and subcutaneous tissues were measured by HF-USG at the sites of the most severe skin lesions on the affected limbs and at the corresponding sites on the healthy limbs, and white blood cell (WBC) counts, neutrophil (NEU) counts, as well as C-reaction protein (CRP) levels were determined. The t test and non-parametric test were used to compare the efficacy between two groups. Results:A total of 23 patients with erysipelas were enrolled. Among the 12 patients in the study group, 8 were males and 4 were females, and their age was 71.4 ± 11.4 years. Among the 11 patients in the control group, 7 were males and 4 were females, and their age was 67.4 ± 11.1 years. Before treatment, the thicknesses of the epidermis-dermis layers (0.33 ± 0.12 cm) and subcutaneous tissues (1.08 ± 0.49 cm) in the study group were not significantly different from those in the control group (0.25 ± 0.09 cm, 0.98 ± 0.46 cm; t = -1.83, -0.49, P = 0.081, 0.626, respectively). After the 10-day treatment, the thicknesses of the epidermis-dermis layers and subcutaneous tissues of the skin lesions on the affected limbs significantly decreased in both groups compared with those before treatment (both P < 0.05), and the decrease in the thicknesses of subcutaneous tissues was significantly stronger in the study group (0.32 ± 0.33 cm) than in the control group (0.10 ± 0.07 cm; t = 2.20, P = 0.039). Before treatment, the WBC counts ([11.16 ± 4.42] × 10 9/L), NEU counts ([8.26 ± 4.16] × 10 9/L) and CRP levels (median [ Q1, Q3]: 72.20 [19.28, 140.50] mg/L) in the study group were not significantly different from those in the control group ([10.10 ± 4.53] × 10 9/L, [7.21 ± 3.00] × 10 9/L, 34.40 [8.00, 74.20] mg/L, respectively; t or Z = 0.60, 0.71, -0.85, P = 0.578, 0.496, 0.196, respectively). After the 10-day treatment, the WBC counts, NEU counts, and CRP levels significantly decreased in both groups compared with those before treatment (all P < 0.05) . Conclusion:The combined treatment with systemic antibiotics and glucocorticoids could effectively alleviate skin inflammation, and more rapidly reduce the thicknesses of inflamed subcutaneous tissues in patients with erysipelas compared with systemic antibiotics alone.

5.
Chinese Journal of Ultrasonography ; (12): 508-514, 2023.
Artigo em Chinês | WPRIM | ID: wpr-992855

RESUMO

Objective:To discuss the effect of remnant cholesterol (RC) levels on carotid intima thickness (CIT) in patients with type 2 diabetes mellitus (T2DM) by ultra-high frequency ultrasound.Methods:A total of 60 patients with T2DM who received treatment in Henan Provincial People′s Hospital from May 2021 to July 2022 were prospectively recruited, and they were divided into a higher RC group (31 cases) and a lower RC group (29 cases) according to the RC levels. Thirty-one age, sex and body mass index(BMI)-matched healthy volunteers were selected as control group. Carotid CIT, carotid media thickness(CMT) and intima-media thickness(CIMT) were measured by 24 MHz ultra-high frequency ultrasound probe. The difference of general clinical data, laboratory indicators and CIMT, CIT, CMT among the three groups were compared, and the influencing factors of CIT in T2DM patients were explored by multivariate regression analysis.Results:①There were no statistical significances in gender, age, BMI, high-density lipoprotein cholesterol (HDL-C) and CMT among the three groups (all P>0.05). There were no statistical significances in duration of diabetes, fasting blood-glucose and glycated haemoglobin between the two subgroups of T2DM (all P>0.05). ②Compared with the control group, CIMT and CIT were thicker in the T2DM group (both P<0.05). ③CIT was thicker in the higher RC group than in the lower RC group ( P<0.05), while the difference of CIMT was not statistically significant the two groups ( P>0.05). ④Multivariate regression analysis showed that RC was the influence factor of CIT in patients with T2DM(β=0.610, P=0.005). Conclusions:CIT is significantly thicker in T2DM patients with higher RC than in those with lower RC, and RC is the influence factor of CIT, which suggests that more attention should be paid to the detection of RC in T2DM patients.

6.
Chinese Journal of Neonatology ; (6): 151-156, 2023.
Artigo em Chinês | WPRIM | ID: wpr-990736

RESUMO

Objective:To study the risk factors of failure using nasal high frequency oscillatory ventilation (nHFOV) as initial therapy in the treatment of respiratory distress syndrome (RDS) in very low birth weight infants (VLBWIs).Methods:From January 2018 to December 2021, VLBWIs with RDS initially supported by nHFOV in NICU of our hospital were retrospectively analyzed. They were assigned into success and failure groups according to the ventilation efficacy. Demographic data and clinical outcomes of the two groups were compared. Risk factors of initial nHFOV failure were analyzed using binary Logistic regression method.Results:A total of 135 infants were included, including 103 in the success group and 32 in the failure group. The initial nHFOV failure rate was 23.7%. The failure group had lower pH (7.26±0.09 vs. 7.33±0.08) and PaO 2 [61.0 (49.6, 77.2) mmHg vs. 83.6 (64.4, 99.0) mmHg] than the success group ( P<0.05) and higher PaCO 2 than the success group [49.0 (42.3, 58.1) mmHg vs. 43.4 (36.0, 50.0) mmHg] ( P<0.05). Using PaCO 2 as predictor, the area under the curve (AUC) was 0.682 (95% CI 0.575-0.788) and the cut-off value was 44.8 mmHg for nHFOV failure and the AUC was 0.716 (95% CI 0.615-0.817) and the cut-off value was 67.1 mmHg for nHFOV success. The incidences of early onset sepsis (EOS), shock within 3 d and hemodynamically significant patent ductus arteriosus (hsPDA) in the failure group were significantly higher than the success group (40.6% vs. 7.8%, 53.1% vs. 2.9%, 31.3% vs. 13.6%, P<0.05, respectively). Binary logistic regression analysis found that PaO 2<67.1 mmHg ( OR=5.458,95% CI 1.730-17.220) on the first blood gas analysis and shock within 3 d ( OR=26.585,95% CI 3.854-183.396) were independent risk factors for initial nHFOV failure ( P<0.05). Conclusions:The failure of initial nHFOV is correlated with the first blood gas parameters, EOS, hsPDA and shock within 3 d. Shock within 3 d and low PaO 2(<67.1 mmHg) were independent risk factors for initial nHFOV failure.

7.
Chinese Journal of Neonatology ; (6): 101-106, 2023.
Artigo em Chinês | WPRIM | ID: wpr-990731

RESUMO

Objective:To evaluate the efficacy and safety of noninvasive high-frequency oscillatory ventilation (nHFOV) as the initial ventilation mode for respiratory distress syndrome (RDS) in premature infants.Methods:From the establishment of the databases [(PubMed, Embase, Cochrane Library, CNKI, Wanfang database, CQVIP and CBM (SinoMed)] to March 1, 2022, literature on randomized controlled trials (RCTs) using nHFOV and nasal continuous positive airway pressure(NCPAP) as the initial ventilation modes for RDS in premature infants were searched. The qualities of the included literature were evaluated according to Cochrane Evaluation Manual. RevMan 5.4 software was used for Meta-analysis.Results:Seven RCTs involving 786 children were included for the final Meta-analysis, with 395 cases in the nHFOV group and 391 cases in the NCPAP group. The results showed that the nHFOV group had lower intubation rates than the NCPAP group ( OR=0.34, 95% CI 0.22~0.51, P<0.001). No significant differences existed in mortality rates and complication rates between the two groups ( P>0.05). Conclusions:nHFOV as the initial treatment for RDS in premature infants may reduce the incidence of early treatment failure without increasing complications.

8.
International Journal of Biomedical Engineering ; (6): 288-299, 2023.
Artigo em Chinês | WPRIM | ID: wpr-989353

RESUMO

Objective:To improve the users’ comfort of steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) through high-frequency stimulation and overcome the problem of accuracy decline caused by high frequency by combining dual-frequency encoding.Methods:Two dual-frequency high-frequency 60-instruction paradigms based on left and right visual fields and checkerboard stimuli were designed based on the 25.5 - 39.6 Hz frequency. Thirteen subjects participated in the experiment, and spectrum and spatial characteristics analyses were performed on SSVEP signals. The filter bank parameters were optimized based on the spectrum characteristics. Extended canonical correlation analysis (eCCA), ensemble task-related component analysis (eTRCA), and task-discriminant component analysis (TDCA) were used for SSVEP recognition.Results:Stable SSVEP was successfully induced in both the left and right visual fields and the checkerboard grid paradigm. The left and right visual fields had high signal-to-noise ratios for the fundamental frequency and its harmonics and weak signal-to-noise ratios for intermodulation components, whereas the intermodulation components of the 2 stimulus frequencies of the checkerboard grid, f1 + f2, had significantly higher signal-to-noise ratios than the second harmonic components above 30 Hz, and there was also a f2 ? f1 component and a 2 f1 ? f2 component. Combined with brain topography, it can be seen that the f1 and f2 response components of the left and right visual fields are located on opposite sides of the visual field, while the checkerboard grids are both concentrated in the center of the occipital region. Regarding the lateralization of brain topography amplitude and signal-to-noise ratio, the mean values of the PO3 and PO4 signal-to-noise ratios at the stimulation frequency of the left and right visual fields are consistent with the contralateral response characteristics. The 5 fb ? 1 method is the optimal filter set setting method, and the recognition correctness rate of TDCA for the left and right visual fields is the highest. However, the comparison of the recognition correctness rate of tessellated lattice eTRCA and TDCA is not statistically significant ( P > 0.05). The information transmission rates of the three algorithms all increase and then decrease with the increase in data length. Conclusions:The designed dual-frequency, high-frequency SSVEP-BCI paradigm is able to better balance performance and comfort and provides a basis for practical large instruction set BCI design methods.

9.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 160-168, 2023.
Artigo em Chinês | WPRIM | ID: wpr-988192

RESUMO

ObjectiveTo explore the macroscopic medication pattern of traditional Chinese medicine (TCM) in treating esophageal cancer (EC) and provide medication references for the clinical application of TCM in EC treatment. MethodRelevant literature on TCM treatment of EC was retrieved from three major Chinese databases: China National Knowledge Infrastructure (CNKI), Wanfang Data, and VIP. Information about Chinese herbal medicines was entered into Excel to establish a prescription database for EC. The data were standardized, summarized, and subjected to frequency analysis, association rules, and cluster analysis of medication in the prescriptions. Based on the TCM classification of EC syndromes, clinical indications corresponding to each syndrome were identified, and high-frequency drugs and drug pairs were analyzed correspondingly with syndromes. ResultA total of 136 prescriptions containing 240 Chinese herbal medicines were screened, with a cumulative frequency of 1 853 times. The top 5 frequently used Chinese herbal medicines were Glycyrrhizae Radix et Rhizoma, Poria, Atractylodis Macrocephalae Rhizoma, Astragali Radix, and Pinelliae Rhizoma. In terms of functions, the Chinese herbal medicines were mainly deficiency-tonifying, urination-promoting and dampness-draining, deficiency-tonifying, deficiency-tonifying, and phlegm-resolving and cough and dyspnea-relieving ones. The statistical analysis of flavor, property, and meridian tropism showed that Chinese herbal medicines were mainly bitter and sweet, warm, cold, and neutral, and acted on the spleen, lung, and stomach meridians. Association rule analysis yielded nine potential drug combinations, and cluster analysis of high-frequency drugs resulted in four combination categories. The four TCM syndromes for EC corresponded to respective clinical indications, treatment drugs, and drug pairs. ConclusionTonifying deficiency, reinforcing healthy Qi, descending adverse Qi, resolving phlegm, activating blood, and resolving stasis are the basic principles of TCM treatment for EC, which are supplemented by clearing heat and dissipating mass while focusing on regulating and smoothing the qi movement. The drug combinations obtained from high-frequency drug and association rule analysis provide references for different TCM syndrome treatments of EC, offering valuable insights for clinical medication.

10.
Journal of Modern Urology ; (12): 588-590, 2023.
Artigo em Chinês | WPRIM | ID: wpr-1006028

RESUMO

【Objective】 To investigate the efficacy of in vitro local high-frequency hyperthermia combined with drugs in the treatment of type Ⅲb chronic prostatitis (CP). 【Methods】 A total of 148 patients with type Ⅲb CP treated in our hospital during Jun.2020 and Jun.2022 were randomly divided into control group (n=74) and combination group (n=74). The control group received only drug treatment, while the combination group received extracorporeal local high-frequency hyperthermia treatment. The National Institutes of Health Chronic Prostatitis Symptom Index (NIH-CPSI), maximum urinary flow rate (MFR), average urinary flow rate (AFR) and International Index of Erectile Function-5 (IIEF-5) score were compared between the two groups. 【Results】 There were no significant differences between the two groups in terms of NIH-CPSI, MFR, AFR and IIEF-5 score before treatment(P>0.05). After treatment, these indexes increased in both groups (P<0.05), and the improvements in the combination group were more significant (P<0.05). 【Conclusion】 Medication combined with in vitro local high-frequency hyperthermia is effective in improving the clinical symptoms of type Ⅲb CP, which is worth clinical promotion.

11.
Journal of Environmental and Occupational Medicine ; (12): 1196-1200, 2023.
Artigo em Chinês | WPRIM | ID: wpr-998777

RESUMO

Background The influencing factors of noise hazards in the automotive manufacturing industry are complex, diverse, and mutually correlated, resulting in significant health impacts on workers. Objective To explore the application of generalized estimating equations (GEE) to analyze the factors affecting high-frequency hearing loss among noise-exposed workers in an automotive manufacturing company, guiding enterprises to scientifically carry out employee hearing protection programs. Methods The data of occupational health field evaluation and occupational health surveillance of an automobile manufacturing company for five consecutive years from 2018 to 2022 were collected, and 806 noise-exposed workers with pure tone hearing test results for all five consecutive years were selected as study participants. The retrieved indicators were gender, physical examination year, noise intensity, blood pressure, white blood cell counts, red blood cell counts, platelet counts, concentrations of hemoglobin, alanine transaminase, aspartate aminotransferase, smoking, drinking, etc. Gender, noise intensity, blood pressure, white blood cell counts, red blood cell counts, concentrations of hemoglobin, platelet counts, glutamate aminotransferase, glutamate aminotransferase, smoking, and drinking were set as independent variables, and occurrence of high-frequency hearing loss was set as a dependent variable, and GEE were constructed by using the statistical software of SPSS 20.0 to analyze the influencing factors of high-frequency hearing loss. Results Of the 806 workers, 698 were male (86.6%) and 108 were female (13.4%). The detection rates of high-frequency hearing loss in each year from 2018 to 2022 were 66.4% (535/806), 69.8% (563/806), 70.0% (564/806), 68.9% (555/806), and 68.2% (550/806), respectively. The detection rate of high-frequency hearing loss in the company was varied significantly by gender, lowered white blood cell counts, lowered red blood cell counts, lowered platelet counts, smoking, and drinking (P<0.05). The results of GEE analysis showed that after adjusting for selected confounding factors and excluding interaction effects, the risk of high-frequency hearing loss was higher in men than in women (P=0.001; OR=1.907, 95%CI: 1.286, 2.829); it was higher in workplace with disqualified noise intensity than in those without (P=0.043; OR=1.289, 95%CI: 1.009, 1.648); it was also higher in smokers than in non-smokers (P=0.004; OR=1.507, 95%CI: 1.137, 1.999). Conclusion Gender, noise intensity, and smoking are the main influencing factors of high-frequency hearing loss in noise-exposed workers in this automobile manufacturing company. Controlling smoking and reducing noise exposure intensity may reduce the occurrence of high-frequency hearing loss in workers.

12.
China Occupational Medicine ; (6): 507-511, 2023.
Artigo em Chinês | WPRIM | ID: wpr-1013317

RESUMO

{L-End}Objective To study the situation of occupational noise exposure and hearing loss in workers in petrochemical enterprises. {L-End}Methods A total of 2 052 workers from four large-scale petrochemical enterprises in China were selected as the research subjects using convenience sampling method. The noise-exposed level of job position was detected by individual noise dosimeters, and pure-tone audiometry of the workers was conducted. {L-End}Results The noise-exposed levels at various job positions in the workplace of the enterprises ranged from 83.2 to 86.7 dB(A), and 61.1% of the job positions had a cumulative noise exposure (CNE) > 95.0 dB(A) per year. The detection rate of high-frequency hearing loss was 12.6%(259/2 052) among the research subjects. The detection rate of speech frequency hearing loss was 5.5%(112/2 052) among the research subjects. The result of CNE stratified analysis showed that the detection rate of hearing loss at frequencies of 2.0, 3.0, 4.0, and 6.0 kHz, as well as high frequencies, gradually increased with increasing CNE (all P<0.05). {L-End}Conclusion The noise hazard in petrochemical enterprises is severe, and long-term occupational noise exposure can increase the risk of hearing loss among workers. Efforts should be made to strengthen noise control and hearing protection measures.

13.
Journal of Preventive Medicine ; (12): 957-960, 965, 2023.
Artigo em Chinês | WPRIM | ID: wpr-1013265

RESUMO

Objective @#To investigate the current status of hearing loss in a fastener manufacturing enterprise, and to analyze its influencing factors, so as to provide insights into occupational disease prevention and control. @*Methods@#The occupational health examination data of noise exposed workers and the workplace occupational disease hazard factors detection data in a fastener manufacturing enterprise in Jiaxing City in 2022 were collected through the Occupational Disease and Occupational Health Hazard Factors Detection System of China Disease Prevention and Control Information System, and factors affecting the development of high-frequency noise-induced hearing loss (HFNIHL) and speech-frequency noise-induced hearing loss (SFNIHL) were analyzed. @*Results@#Totally 625 workers were investigated, with a median age of 44.00 (interquartile range, 13.00) years and a median length of service of 8.00 (interquartile range, 9.00) years, and including 519 men (83.04%) and 106 women (16.96%). There were 309 workers with single noise exposure (49.44%) and 316 workers with joint noise exposure (50.56%), and 518 workers exposed to noise with the normalized continuous A-weighted sound pressure level equivalent to a 40 h working week (LEX,40 h) that exceeded the national standard (82.88%). The detection rates of HFNIHL and SFNIHL were 49.12% and 35.04%, respectively. Multivariable logistic regression analysis indicated that males (OR=10.528, 95%CI: 5.271-21.025), length of service of 10 years and longer (OR=2.451, 95%CI: 1.599-3.759), LEX,40 h of >85 dB (A) (OR=2.227, 95%CI: 1.318-3.764) and joint noise exposure (OR=3.002, 95%CI: 2.080-4.334) were associated with an increased risk of HFNIHL, and male (OR=9.400, 95%CI: 4.211-20.985), LEX,40 h of >85 dB (A) (OR=2.305, 95%CI: 1.345-3.951), and joint noise exposure (OR=3.880, 95%CI: 2.677-5.623) were associated with an increased risk of SFNIHL.@*Conclusion@#Gender, length of service, noise intensity and exposure mode are factors affecting the risk of HFNIHL, while gender, noise intensity and exposure mode are factors affecting the risk of SFNIHL.

14.
Acta Academiae Medicinae Sinicae ; (6): 436-439, 2023.
Artigo em Chinês | WPRIM | ID: wpr-981288

RESUMO

Objective To investigate the clinical value of high-frequency ultrasound in the diagnosis of pronator teres syndrome (PTS). Methods The high-frequency ultrasound was employed to examine and measure the median nerve of the pronator teres muscle in 30 patients with PTS and 30 healthy volunteers (control group).The long-axis diameter (LA),short-axis diameter (SA) and cross-sectional area (CSA) of the median nerve were measured.The receiver operating characteristic curve of the median nerve ultrasonic measurement results was established,and the area under the curve (AUC) was calculated.The diagnostic efficiency of each index for PTS was compared with the surgical results as a reference. Results The PTS group showed larger LA[(5.02±0.50) mm vs.(3.89±0.41) mm;t=4.38,P=0.013],SA[(2.55±0.46) mm vs.(1.70±0.41) mm;t=5.19,P=0.009],and CSA[(11.13±3.72) mm2 vs.(6.88±2.68) mm2;t=8.42,P=0.008] of the median nerve than the control group.The AUC of CSA,SA,and LA was 94.3% (95%CI=0.912-0.972,Z=3.586,P=0.001),77.7% (95%CI=0.734-0.815,Z=2.855, P=0.006),and 78.8% (95%CI=0.752-0.821,Z=3.091,P=0.004),respectively.With 8.63 mm2 as the cutoff value,the sensitivity and specificity of CSA in diagnosing PTS were 93.3% and 90.0%,respectively. Conclusion High-frequency ultrasound is a practical method for diagnosing PTS,and the CSA of median nerve has a high diagnostic value.


Assuntos
Humanos , Antebraço/inervação , Músculo Esquelético/inervação , Nervo Mediano/diagnóstico por imagem , Ultrassonografia/métodos , Sensibilidade e Especificidade
15.
International Eye Science ; (12): 425-429, 2023.
Artigo em Chinês | WPRIM | ID: wpr-964242

RESUMO

ArcScan Insight 100 very high-frequency(VHF)digital ultrasound scanner is a new ocular ultrasonic measuring instrument, which can detect and measure the anterior segment. It can be used for screening before corneal refractive surgery and follow-up after corneal refractive surgery, measuring anterior segment parameters before implantable collamer lens(ICL)implantation, predicting preoperative vault, measuring postoperative vault, early screening keratoconus, and diagnosing glaucoma, cataract and eye injuries, etc. Taking the advantages of a wide range examination of ultrasound biomicroscope(UBM)and simple operation of optical coherence tomography(OCT), it has a broad prospect for clinical application. In this paper, the measurement principle, application method, parameters and clinical application progress of ArcScan Insight 100 VHF digital ultrasound scanner are reviewed in detail.

16.
Chinese Journal of Contemporary Pediatrics ; (12): 295-301, 2023.
Artigo em Chinês | WPRIM | ID: wpr-971076

RESUMO

OBJECTIVES@#To systematically evaluate the efficacy and safety of noninvasive high-frequency oscillatory ventilation (NHFOV) versus nasal intermittent positive pressure ventilation (NIPPV) as post-extubation respiratory support in preterm infants.@*METHODS@#China National Knowledge Infrastructure, Wanfang Data, Chinese Journal Full-text Database, China Biology Medicine disc, PubMed, Web of Science, and the Cochrane Library were searched for articles on NHFOV and NIPPV as post-extubation respiratory support in preterm infants published up to August 31, 2022. RevMan 5.4 software and Stata 17.0 software were used for a Meta analysis to compare related indices between the NHFOV and NIPPV groups, including reintubation rate within 72 hours after extubation, partial pressure of carbon dioxide (PCO2) at 6-24 hours after switch to noninvasive assisted ventilation, and the incidence rates of bronchopulmonary dysplasia (BPD), air leak, nasal damage, periventricular leukomalacia (PVL), intraventricular hemorrhage (IVH), and retinopathy of prematurity (ROP).@*RESULTS@#A total of 9 randomized controlled trials were included. The Meta analysis showed that compared with the NIPPV group, the NHFOV group had significantly lower reintubation rate within 72 hours after extubation (RR=0.67, 95%CI: 0.52-0.88, P=0.003) and PCO2 at 6-24 hours after switch to noninvasive assisted ventilation (MD=-4.12, 95%CI: -6.12 to -2.13, P<0.001). There was no significant difference between the two groups in the incidence rates of complications such as BPD, air leak, nasal damage, PVL, IVH, and ROP (P>0.05).@*CONCLUSIONS@#Compared with NIPPV, NHFOV can effectively remove CO2 and reduce the risk of reintubation, without increasing the incidence of complications such as BPD, air leak, nasal damage, PVL, and IVH, and therefore, it can be used as a sequential respiratory support mode for preterm infants after extubation.


Assuntos
Lactente , Recém-Nascido , Humanos , Recém-Nascido Prematuro , Ventilação com Pressão Positiva Intermitente , Extubação , Ventilação não Invasiva , Displasia Broncopulmonar , Ventilação de Alta Frequência , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Pressão Positiva Contínua nas Vias Aéreas
17.
Journal of Biomedical Engineering ; (6): 155-162, 2023.
Artigo em Chinês | WPRIM | ID: wpr-970686

RESUMO

Steady-state visual evoked potential (SSVEP) has been widely used in the research of brain-computer interface (BCI) system in recent years. The advantages of SSVEP-BCI system include high classification accuracy, fast information transform rate and strong anti-interference ability. Most of the traditional researches induce SSVEP responses in low and middle frequency bands as control signals. However, SSVEP in this frequency band may cause visual fatigue and even induce epilepsy in subjects. In contrast, high-frequency SSVEP-BCI provides a more comfortable and natural interaction despite its lower amplitude and weaker response. Therefore, it has been widely concerned by researchers in recent years. This paper summarized and analyzed the related research of high-frequency SSVEP-BCI in the past ten years from the aspects of paradigm and algorithm. Finally, the application prospect and development direction of high-frequency SSVEP were discussed and prospected.


Assuntos
Humanos , Interfaces Cérebro-Computador , Potenciais Evocados Visuais , Algoritmos
18.
Chinese Journal of Contemporary Pediatrics ; (12): 1101-1106, 2023.
Artigo em Chinês | WPRIM | ID: wpr-1009854

RESUMO

OBJECTIVES@#To investigate the therapeutic efficacy of volume-guaranteed high frequency oscillation ventilation (HFOV-VG) versus conventional mechanical ventilation (CMV) in the treatment of preterm infants with respiratory failure.@*METHODS@#A prospective study was conducted on 112 preterm infants with respiratory failure (a gestational age of 28-34 weeks) who were admitted to the Department of Neonatology, Jiangyin Hospital Affiliated to Medical School of Southeast University, from October 2018 to December 2022. The infants were randomly divided into an HFOV-VG group (44 infants) and a CMV group (68 infants) using the coin tossing method based on the mode of mechanical ventilation. The therapeutic efficacy was compared between the two groups.@*RESULTS@#After 24 hours of treatment, both the HFOV-VG and CMV groups showed significant improvements in arterial blood pH, partial pressure of oxygen, partial pressure of carbon dioxide, and partial pressure of oxygen/fractional concentration of inspired oxygen ratio (P<0.05), and the HFOV-VG group had better improvements than the CMV group (P<0.05). There were no significant differences between the two groups in the incidence rate of complications, 28-day mortality rate, and length of hospital stay (P>0.05), but the HFOV-VG group had a significantly shorter duration of invasive mechanical ventilation than the CMV group (P<0.05). The follow-up at the corrected age of 6 months showed that there were no significant differences between the two groups in the scores of developmental quotient, gross motor function, fine motor function, adaptive ability, language, and social behavior in the Pediatric Neuropsychological Development Scale (P>0.05).@*CONCLUSIONS@#Compared with CMV mode, HFOV-VG mode improves partial pressure of oxygen and promotes carbon dioxide elimination, thereby enhancing oxygenation and shortening the duration of mechanical ventilation in preterm infants with respiratory failure, while it has no significant impact on short-term neurobehavioral development in these infants.


Assuntos
Lactente , Criança , Recém-Nascido , Humanos , Recém-Nascido Prematuro , Estudos Prospectivos , Idade Gestacional , Dióxido de Carbono , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Ventilação de Alta Frequência/métodos , Respiração Artificial , Insuficiência Respiratória/terapia , Oxigênio , Infecções por Citomegalovirus
19.
China Journal of Orthopaedics and Traumatology ; (12): 1080-1084, 2023.
Artigo em Chinês | WPRIM | ID: wpr-1009189

RESUMO

OBJECTIVE@#To study and analyze the diagnostic value and interventional treatment value of high-frequency ultrasound for elbow cyst.@*METHODS@#From February 2018 to February 2021, the data of 60 patients with elbow cyst treated by high-frequency ultrasound interventional therapy were retrospectively analyzed, including 30 males and 30 females with an average age of (30.93±5.32) years old ranging from 20 to 54 years old. The course of disease ranged from 1 to 10 years with an average of (3.45±0.25) years. High-frequency ultrasound features of all patients were analyzed. The clinical efficacy, the occurrence of adverse events and the changes of psychological status before and after treatment were analyzed.@*RESULTS@#In 60 cases of elbow cyst, the cyst size was from 6 mm×7 mm to 111 mm×60 mm. The characteristics of ultrasonic images included such as most of the morphology was regular, which was round or oval, and a few were irregular;the boundary was clear, there was a capsule wall, most of the inside of the capsule was good, no echo;when accompanied by bleeding or infection, small dense points can be seen floating;the cystic wall of the patients with long course of disease was coarser, and the internal light bands were separated, showing multilocular shape;no significant blood flow signal was observed. Final results involved olecranon bursa cysts in 19 cases, annular ligament cysts in 10 cases, radial bursa cysts in 9 cases, accessory ligament cysts in 7 cases, epidermoid cysts in 4 cases, ganglion cysts in 6 cases, nerve sheath cysts in 5 cases. After treatment, 33 cases were cured, 16 cases had obvious effect, 11 cases were improved, 0 cases were invalid. After treatment, mild adverse events occurred in 1 case, moderate adverse events in 1 case, and severe adverse events in 0 cases, with a total incidence of 3.33% (2/60). After treatment, positive affect score (38.04±1.74) was higher than that before treatment (35.92±2.34), and negative affect score (24.61±1.51) was lower than that before treatment (30.15±3.46), with statistical significance(P<0.05).@*CONCLUSION@#High-frequency ultrasound has high diagnostic value for elbow cyst, and it has ideal effect in interventional therapy.


Assuntos
Masculino , Feminino , Humanos , Adulto , Adulto Jovem , Pessoa de Meia-Idade , Estudos Retrospectivos , Cotovelo , Cistos , Ultrassonografia , Resultado do Tratamento
20.
Journal of Biomedical Engineering ; (6): 886-893, 2023.
Artigo em Chinês | WPRIM | ID: wpr-1008913

RESUMO

In this paper, the differences between air probe and filled probe for measuring high-frequency dielectric properties of biological tissues are investigated based on the equivalent circuit model to provide a reference for the methodology of high-frequency measurement of biological tissue dielectric properties. Two types of probes were used to measure different concentrations of NaCl solution in the frequency band of 100 MHz-2 GHz. The results showed that the accuracy and reliability of the calculated results of the air probe were lower than that of the filled probe, especially the dielectric coefficient of the measured material, and the higher the concentration of NaCl solution, the higher the error. By laminating the probe terminal, liquid intrusion could be prevented, to a certain extent, to improve the accuracy of measurement. However, as the frequency decreased, the influence of the film on the measurement increased and the measurement accuracy decreased. The results of the study show that the air probe, despite its simple dimensional design and easy calibration, differs from the conventional equivalent circuit model in actual measurements, and the model needs to be re-corrected for actual use. The filled probe matches the equivalent circuit model better, and therefore has better measurement accuracy and reliability.


Assuntos
Reprodutibilidade dos Testes , Cloreto de Sódio , Calibragem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA