Chinese Medical Equipment Journal ; (6): 86-89, 2017.
Artigo em Chinês | WPRIM | ID: wpr-660203

RESUMO

Objective To discuss the technical specifications of current high-frequency electrotome detection,to avoid the hidden danger of high-frequency electrotome power detectors,and to measure the leakage current of different kinds of highfrequency electrotome accurately.Methods The power and leakage current of the high frequency electrotome were measured by FLUCK QA-ES Ⅱ high frequency electrotome analyzer.The safety of the two methods was compared before and after the improvement of the power measurement.Four parameters of leakage current were repeatedly measured with the ways of high frequency earthing and high frequency isolation respectively.The maximum measurement of leakage current was recorded.Results The improved connection method was safe in the power measurement.For the high-frequency electrotome in the model of high frequency earthing,the values of leakage current were restrained within the range of error with two ways of monopolar loading operation electrode and neutral electrode.For the high-frequency electrotome in the model of high frequency isolation,the values of leakage current were limited within the range of error withtwo ways of monopolar empty operation electrode and neutral electrode.Conclusion The improved high-frequency electrotome power detection method is safe for detectors.The data obtained from the leakage current detection method using the national standard correction method reflect the actual state of the high-frequency electrotome,when the electrotome with earth as the reference is used to detect the leakage current with loading or the insulated electrotome is applied to measuring the leakage current with no loading.

2.
Chinese Medical Equipment Journal ; (6): 86-89, 2017.
Artigo em Chinês | WPRIM | ID: wpr-662519

RESUMO

Objective To discuss the technical specifications of current high-frequency electrotome detection,to avoid the hidden danger of high-frequency electrotome power detectors,and to measure the leakage current of different kinds of highfrequency electrotome accurately.Methods The power and leakage current of the high frequency electrotome were measured by FLUCK QA-ES Ⅱ high frequency electrotome analyzer.The safety of the two methods was compared before and after the improvement of the power measurement.Four parameters of leakage current were repeatedly measured with the ways of high frequency earthing and high frequency isolation respectively.The maximum measurement of leakage current was recorded.Results The improved connection method was safe in the power measurement.For the high-frequency electrotome in the model of high frequency earthing,the values of leakage current were restrained within the range of error with two ways of monopolar loading operation electrode and neutral electrode.For the high-frequency electrotome in the model of high frequency isolation,the values of leakage current were limited within the range of error withtwo ways of monopolar empty operation electrode and neutral electrode.Conclusion The improved high-frequency electrotome power detection method is safe for detectors.The data obtained from the leakage current detection method using the national standard correction method reflect the actual state of the high-frequency electrotome,when the electrotome with earth as the reference is used to detect the leakage current with loading or the insulated electrotome is applied to measuring the leakage current with no loading.

3.
China Medical Equipment ; (12): 25-26,27, 2015.
Artigo em Chinês | WPRIM | ID: wpr-601385

RESUMO

Objective:To study the electrical safety of multi-parameter monitor and defibrillation monitor, and guarantee the safe and effective operation by through the medical equipment electrical safety performance in our hospital.Methods: To test 101 different models of multi-parameter monitor and defibrillation monitor electrical safety.Results: The one-time pass rate of 96%, and the two-time rate was 98%, also one multi-parameter monitor and defibrillation monitor hadn’t meet electrical safety performance after repairing.Conclusion: The equipments that don’t meet electrical safety performance prohibit using for clinical purposes; To ensure the safety of medical equipment and life safety of medical workers and patients by through developing the testing of the medical equipment electrical safety performance in our hospital.

4.
Chinese Medical Equipment Journal ; (6)2003.
Artigo em Chinês | WPRIM | ID: wpr-590382

RESUMO

Objective To discuss how to deal with the problems of LEEP electro-scalpel that are caused by the burn of negative electrode loose and the electric shock of leakage current.Methods The system's security was enhanced by insulation,power and software control and it was also evaluated.Results The electric leakage of LEEP electro-scalpel was acceptable and the preventive support of burn was effective.Conclusion It is proved by the synthetical evaluation that the device's secure design is reliable.