1.
Cambios rev. méd ; 21(1): 719, 30 Junio 2022. ilus, grafs.
Artigo em Espanhol | LILACS | ID: biblio-1402501

RESUMO

INTRODUCCIÓN. La estimulación cardíaca temporal de larga duración con cable activo y marcapaso permanente externo es una técnica recientemente incluida en las guías de manejo de bradicardias sintomáticas. CASOS CLÍNICOS. Se describen 4 casos de pacientes sometidos a estimulación cardíaca temporal de larga duración con cable activo y marcapaso permanente externo de la unidad de Hemodinámica del Hospital de Especialidades Carlos Andrade Marín, con indicaciones diversas. DISCUSIÓN. El tiempo medio de permanencia con el cable activo y el marcapaso externalizado fue 23 días. No hubo complicaciones del procedimiento. Un paciente falleció por causas no relacionadas con la estimulación y 2 se recuperaron en sus domicilios. CONCLUSIÓN. La técnica de estimulación temporal utilizando marcapasos permanentes recuperados se muestra extremadamente útil para mantener un marcapaso cardíaco seguro, incluso ambulatorio y por largo tiempo, hasta el implante de dispositivos definitivos. Su limitación es la factibilidad de hacerlo solo en centros de tercer nivel.


INTRODUCTION. Long-duration temporary cardiac pacing with active lead and permanent external pacemaker is a technique recently included in the guidelines for the management of symptomatic bradycardias. CLINICAL CASES. We describe 4 cases of patients who underwent long-duration temporary cardiac pacing with active lead and external permanent pacemaker at the Hemodynamics Unit of the Hospital de Especialidades Carlos Andrade Marín, with different indications. DISCUSSION. The mean length of stay with the active lead and externalized pacemaker was 23 days. There were no procedural complications. One patient died of causes unrelated to pacing and 2 recovered at home. CONCLUSIONS. The technique of temporary pacing using retrieved permanent pacemakers is extremely useful for maintaining safe cardiac pacing, even on an outpatient basis and for a long period of time, until implantation of definitive devices. Its limitation is the feasibility of doing it only in third level centers.


Assuntos
Humanos , Masculino , Feminino , Adulto , Idoso , Idoso de 80 Anos ou mais , Marca-Passo Artificial , Bradicardia , Cardiologia , Coração , Frequência Cardíaca , Hemodinâmica , Próteses e Implantes , Atenção Terciária à Saúde , Estimulação Cardíaca Artificial , Suporte Vital Cardíaco Avançado , Equador , Endocardite , Assistência Hospitalar , Parada Cardíaca , Ventrículos do Coração , Antibacterianos
2.
Rev. bras. enferm ; 75(supl.4): e20210192, 2022. tab
Artigo em Inglês | LILACS-Express | LILACS, BDENF | ID: biblio-1351726

RESUMO

ABSTRACT Objective: to understand how the transitional care of nurses to olde adults with artificial pacemaker occurs. Method: a qualitative research, carried out in a philanthropic hospital in the city of Salvador, Bahia, Brazil. Fourteen nurses working in surgical and cardiac inpatient units participated. Data were collected between August and November 2020, through semi-structured interviews, and analyzed using the methodological framework Discourse of the Collective Subject and discussed in the light of Afaf Meleis' theory of transitions. Results: nurses' incipient knowledge about transitional care was identified. It was observed that the nursing discharge report is a facilitating instrument for transitional care. Final considerations: the study pointed out that the transitional care of nurses to older adults with artificial pacemakers does not have a theoretical foundation, reporting as a priority the care with the pacemaker identification card and with the surgical wound.


RESUMEN Objetivo: comprender cómo se produce el cuidado transitorio del enfermero al anciano con marcapasos artificial. Método: investigación cualitativa, realizada en un hospital filantrópico de la ciudad de Salvador, Bahía, Brasil. Participaron 14 enfermeros que laboran en las unidades de internación quirúrgica y cardíaca. Los datos fueron recolectados entre agosto y noviembre de 2020, a través de entrevistas semiestructuradas, y analizados utilizando el marco metodológico Discurso del Sujeto Colectivo y discutidos a la luz de la teoría de las transiciones de Afaf Meleis. Resultados: se identificó el conocimiento incipiente de las enfermeras sobre los cuidados transicionales. Se observó que el informe de alta de enfermería es un instrumento facilitador para la transición asistencial. Consideraciones finales: el estudio señaló que el cuidado transicional de enfermeras al anciano con marcapasos artificiales no tiene un fundamento teórico, reportando como prioridad el cuidado con la tarjeta de identificación del marcapasos y con la herida quirúrgica.


RESUMO Objetivo: apreender como ocorre o cuidado transicional da enfermeira ao idoso com marcapasso artificial. Método: pesquisa qualitativa, realizada em um hospital filantrópico, na cidade de Salvador, Bahia, Brasil. Participaram 14 enfermeiras atuantes nas unidades de internação cirúrgica e cardiológica. Os dados foram coletados entre agosto e novembro de 2020, por meio de entrevista semiestruturada, e analisados pelo referencial metodológico Discurso do Sujeito Coletivo e discutidos à luz da teoria das transições de Afaf Meleis. Resultados: foi identificado conhecimento insipiente das enfermeiras acerca do cuidado transicional. Observou-se que o relatório de alta de enfermagem constitui um instrumento facilitador para a transição do cuidado. Considerações finais: o estudo apontou que o cuidado transicional de enfermeiras ao idoso com marcapasso artificial não possui fundamentação teórica, relatando como prioridade o cuidado com a carteira de identificação do marcapasso e com a ferida operatória.

3.
Medisur ; 19(6)dic. 2021.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1405850

RESUMO

RESUMEN En Cuba, el primer implante de marcapasos se realizó el 6 de julio de 1964, mientras que en Cienfuegos se inicia esta actividad en 1979, por un grupo de profesionales liderados por el Dr. Francisco Riverón Mena, quien se mantuvo durante más de diez años al frente de la estimulación cardíaca, en el Hospital Dr. Gustavo Aldereguía Lima. El presente trabajo se propone describir el método para el implante de marcapasos permanente aplicado en dicha institución, introducido por el Dr. Riverón, como alternativa al modo convencional. Esta técnica requiere muy poca utilización de radiaciones ionizantes; resulta eficaz y más segura, tanto para el paciente como para el personal de salud, pues se emplea radioscopia solo en el último momento del procedimiento, lo cual la diferencia del método convencional. Aunque en la actualidad no se practica, durante la etapa que se aplicó en el hospital, brindó seguridad a pacientes y personal de salud, por lo que debería retomarse su uso.


ABSTRACT In Cuba, the first pacemaker implant was carried out on July 6, 1964, while in Cienfuegos this activity began in 1979, by a group of professionals led by Dr. Francisco Riverón Mena, who stayed for more than ten years in charge of cardiac stimulation, at the Dr. Gustavo Aldereguía Lima Hospital. The present work aims to describe the method for permanent pacemaker implantation applied in said institution, introduced by Dr. Riverón, as an alternative to the conventional mode. This technique requires very little use of ionizing radiation; It is effective and safer, both for the patient and for the health personnel, since fluoroscopy is used only at the last moment of the procedure, which differentiates it from the conventional method. Although it is not currently practiced, during the stage that it was applied in the hospital, it provided security to patients and health personnel, so its use should be resumed.

4.
Acta méd. colomb ; 46(1): 20-26, ene.-mar. 2021. tab, graf
Artigo em Espanhol | LILACS, COLNAL | ID: biblio-1278151

RESUMO

Resumen Introducción: en una unidad de electrofisiología de un hospital de tercer nivel de Manizales, Caldas, se han atendido pacientes en la cuarta edad; sin embargo, existe poca claridad en la literatura sobre las conductas terapéuticas en este grupo etario. Presentamos nuestra experiencia de atención e intervención en pacientes mayores de 80 años entre el 20 de septiembre de 2017 y 7 de octubre de 2019. Métodos: estudio tipo cohorte longitudinal, se recogió información con base en revisión de historias clínicas. Se realizaron seguimientos telefónicos al tercer y sexto mes del procedimiento. Se incluyeron pacientes mayores de 80 años intervenidos de cualquier procedimiento en la sala de electrofisiología. Se excluyeron los pacientes sin información sobre los datos de seguimiento. Resultados: se recogieron datos de 75 pacientes llevados a procedimiento. El 62.7% de los pacientes fueron hombres, las edades oscilaron entre 80 y 95 años. 32.7%, de pacientes con diagnóstico de disfunción sinusal. La comorbilidad más prevalente fue hipertensión arterial (92%). El procedimiento más realizado fue el implante de marcapaso bicameral. La mediana del tiempo de estancia hospitalaria fue de 1 día. EL 70% de los pacientes tuvieron riesgo medio o bajo según la escala CHA2DS2VASc. En el lapso de seis meses se encontró una incidencia acumulada de complicaciones de 4%, con 8% de reconsultas y una mortalidad de 1.3%. Conclusiones: las complicaciones posquirúrgicas, la necesidad y duración de la hospitalización, la tasa de reconsulta y la mortalidad asociada a los procedimientos en este grupo de edad son similares a las observadas en estudios con población menor de 80 años.


Abstract Introduction: fourth age patients have been cared for in the electrophysiology unit of a tertiary care hospital in Manizales, Caldas; however, there is little clarity in the literature regarding therapeutic conduct in this age group. We present our experience of care and intervention in patients over the age of 80 between September 20, 2017 and October 7, 2019. Methods: a longitudinal cohort study in which data was collected from a chart review. Telephone follow up was performed three and six months after the procedure. Patients over the age of 80 who had undergone any procedure in the electrophysiology lab were included. Patients without follow up information were excluded. Results: data were collected on 75 patients undergoing a procedure: 62.7% of the patients were men, ages ranged from 80 to 95, and 32.7% of the patients had a diagnosis of sinus dysfunction. The most prevalent comorbidity was arterial hypertension (92%). The most frequently performed procedure was dual chamber pacemaker implantation. The median hospital stay was one day. Seventy percent of the patients had a medium or low risk according to the CHA2DS2-VASc scale. Over a six-month period, a 4% cumulative incidence of complications was found, with 8% reconsultation and 1.3% mortality. Conclusions: postsurgical complications, the need for and length of hospitalization, the rate of reconsultation and the mortality associated with procedures in this age group are similar to those seen in studies of populations under 80 years old.


Assuntos
Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Idoso de 80 Anos ou mais , Marca-Passo Artificial , Pacientes , Síndrome do Nó Sinusal , Condutas Terapêuticas Homeopáticas , Prontuários Médicos , Eletrofisiologia Cardíaca
5.
Texto & contexto enferm ; 29: e20180486, Jan.-Dec. 2020. tab
Artigo em Inglês | BDENF, LILACS | ID: biblio-1059147

RESUMO

ABSTRACT Objective: to assess the health-related quality of life of patients with a permanent cardiac pacemaker. Method: descriptive, observational, cross-sectional study conducted in the arrhythmia outpatient unit of a university hospital located in the interior of São Paulo, Brazil. The consecutive and non-probabilistic sample was composed of both sexes, older than 29 years old, having a pacemaker for at least one month. Those lacking the cognitive condition to answer the questionnaires, as well as those with dyspnea, weakness, or fatigue at the time the instruments were applied, or with an implantable cardioverter defibrillator, were excluded. The generic instrument Medical Outcomes Study 36 - Item Short-Form Health Survey, composed of 36 questions distributed into eight domains along with the specific instrument Assessment of Quality of Life and Related Events, composed of 20 questions distributed into three domains, were used to assess health-related quality of life. Results: 88 patients participated; most were men, had a partner, and were aged 64.3 (±13) years old on average. The domains from the Medical Outcomes Study 36 that obtained the highest means, that is, were the best-rated, were Social Functioning (78.1; ±26.8) and Emotional Well-Being (68.2; ±23.9), while the lowest means were obtained by Physical Health (48.2; ±41.4) and Physical Functioning (58.5; ±27.9). In regard to the Assessment of Quality of Life and Related Events, the Arrhythmia domain had the highest mean and best quality of life (78.2; ±20.7), while the lowest mean was Dyspnea (71.1; ±26.8). Conclusion: the patients gave the highest health-related quality of life ratings in regard to mental domains and the lowest ratings for the physical domains.


RESUMEN Objetivo: evaluar la calidad de vida relacionada con la salud de pacientes con marcapaso cardíaco definitivo. Método: estudio observacional descriptivo, transversal, realizado en el ambulatorio de arritmia de un hospital universitario del interior del estado de Sao Paulo. La muestra consecutiva y no probabilística estuvo constituida de pacientes de los dos sexos, mayores de 18 años, con marcapaso hace, por lo menos, un mes. Fueron excluidos los que no presentaron condiciones cognitivas para responder a los cuestionarios, como también aquellos que presentaron disnea, debilidad y fatiga, en el momento de la aplicación de los instrumentos; y, también aquellos con desfibrilador cardioversor implantable. Para la evaluación de la calidad de vida relacionada con la salud, se utilizó el instrumento genéricoMedical Outcomes Study 36 - Item Short-Form Health Survey, compuesto por 36 preguntas distribuidas en ocho dominios, y el instrumento específicoAssessment of Quality of Life and Related Events, compuesto por 20 preguntas distribuidas en tres dominios. Resultados: participaron 88 pacientes, la mayoría del sexo masculino y con compañero, con edad media de 64,3 (±13) años. Los dominios que presentaron mayores medias, así como mejores evaluaciones, fueron Aspectos Sociales (78,1; ±26,8) y Salud Mental (68,2; ±23,9), y las menores fueron Aspectos Físicos (48,2; ±41,4) y Capacidad Funcional (58,5; ±27,9), referentes alMedical OutcomesStudy 36. En cuanto al Assessment of Quality of Life and Related Events, el dominio de mayor media y mejor calidad de vida fue Arritmia (78,2; ±20,7), y el de menor, Disnea (71,1; ±26,8). Conclusión: los pacientes presentaron mejores evaluaciones da calidad de vida relacionada con la salud en los dominios mentales y peores en los dominios físicos.


RESUMO Objetivo: avaliar a qualidade de vida relacionada à saúde de pacientes com marca-passo cardíaco definitivo. Método: estudo observacional descritivo, transversal, realizado no ambulatório de arritmia de um hospital universitário do interior paulista. Amostra consecutiva e não probabilística foi constituída de pacientes de ambos os sexos, maiores de 18 anos, com marca-passo há pelo menos um mês. Foram excluídos os que não apresentaram condições cognitivas para responder aos questionários, como também aqueles que apresentaram dispneia, fraqueza e fadiga no momento da aplicação dos instrumentos e com cardioversor desfibrilador implantável. Para a avaliação da qualidade de vida relacionada à saúde, utilizou-se o instrumento genérico Medical Outcomes Study 36 - Item Short-Form Health Survey, composto por 36 questões distribuídas em oito domínios, e o instrumento específico Assessment of Quality of Life and Related Events, composto por 20 questões distribuídas em três domínios. Resultados: participaram 88 pacientes, a maioria do sexo masculino e com companheiro, com a média de idade de 64,3 (±13). Os domínios que apresentaram maiores médias, assim como melhores avaliações, foram Aspectos Sociais (78,1; ±26,8) e Saúde Mental (68,2; ±23,9), e as menores foram em Aspectos Físicos (48,2; ±41,4) e Capacidade Funcional (58,5; ±27,9), referentes ao Medical Outcomes Study 36. Quanto ao Assessment of Quality of Life and Related Events, o domínio de maior média e melhor qualidade de vida foi Arritmia (78,2; ±20,7), e o de menor, Dispneia (71,1; ±26,8). Conclusão: os pacientes apresentaram melhores avaliações da qualidade de vida relacionada à saúde nos domínios mentais e piores nos domínios físicos.


Assuntos
Humanos , Adulto , Marca-Passo Artificial , Arritmias Cardíacas , Cuidados Pós-Operatórios , Qualidade de Vida , Enfermagem
6.
Rev. colomb. cardiol ; 27(4): 330-336, jul.-ago. 2020. tab, graf
Artigo em Espanhol | LILACS, COLNAL | ID: biblio-1289234

RESUMO

Resumen Introducción: El aumento de los implantes de dispositivos de estimulación cardiaca en los últimos años, aunado a la longevidad y al perfil de morbilidad de los pacientes, ha hecho que la incidencia de infecciones asociadas a estos procedimientos aumente. Sin embargo, existe disparidad en Colombia y en el mundo respecto al esquema apropiado de profilaxis antibiótica. Objetivo: Evaluar la incidencia de infecciones postoperatorias con dos protocolos de antibiótico-profilaxia. Métodos: Ensayo clínico controlado aleatorizado en el que se incluyeron 360 pacientes que recibieron implante de dispositivos cardíacos y fueron aleatorizados en dos grupos para recibir una dosis de antibiótico (cefazolina 1 g) (240 pacientes) o tres dosis (120 pacientes). Se realizó seguimiento durante un año. El desenlace principal fue la incidencia de infecciones postoperatorias. Resultados: No se observó una diferencia significativa entre la incidencia de infección postoperatoria en los dos grupos (tres dosis vs. una dosis: OR crudo 0.92; IC95% 0.23 - 3.64; p 0.912), con una tasa de 2.9% (7/238) en el grupo de una dosis y de 2.7% (3/110) en el grupo de tres dosis. Tras el análisis multivariado se identificó a la enfermedad renal crónica como un predictor independiente para el desarrollo de complicaciones infecciosas (OR ajustado 4.71; IC95% 1,13 - 19,60). Conclusión: El uso de un protocolo de única dosis de antibiótico profiláctico una hora antes del implante de dispositivos de estimulación cardiaca parece no ser inferior al protocolo de tres dosis postoperatorias.


Abstract Introduction: The increase in implantable cardiac stimulation devices in the last few years, along with the longevity and morbidity characteristics of the patient, has led to an increase in infections associated with these procedures. However, there are differences in Colombia and in the rest of the world as regards a suitable antibiotic prophylaxis scheme. Objective: To evaluate the incidence of post-operative infections with two antibiotic prophylaxis protocols. Methods: A controlled, randomised clinical trial was performed, in which 360 patients that had received a cardiac device implant were randomised into two groups: one with 240 patients to receive one dose of antibiotic (1 g cephazolin), and another of 120 patients to receive 3 doses. The patients were followed-up for one year. The primary outcome was the incidence of post-operative infections. Results: No significant difference was observed in the incidence of post-operative infections between the two groups (three doses versus one dose: crude OR, 0.92; 95% CI; 0.23 - 3.64; P = .912), with a rate of 2.9% (7/238) in the one-dose group, and 2.7% (3/110) in the three-dose group. After the multivariate analysis, chronic kidney disease was identified as an independent predictor of developing infectious complications (adjusted OR = 4.71; 95% CI; 1.13 - 19.60). Conclusion: The use of a single-dose prophylaxis antibiotic protocol one hour before the implantation of cardiac stimulator devices does not appear to be inferior to the three-dose post-operative protocol.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Antibioticoprofilaxia , Cefazolina , Antibacterianos
7.
CorSalud ; 11(1): 79-83, ene.-mar. 2019. graf
Artigo em Espanhol | LILACS | ID: biblio-1089714

RESUMO

RESUMEN Las infecciones por los dispositivos cardiovasculares son cada vez más frecuentes. Se presenta el caso de un hombre de 62 años edad con fiebre y toma del estado general, que había sido intervenido hacía siete años para la implantación de un marcapasos. En los complementarios se observaron leucocitosis y hemoglobina por debajo de 10 g/L; y en el ecocardiograma, un electrodo de marcapaso en cavidades derechas con múltiples masas ecodensas que indicaban endocarditis infecciosa. Se realizó extracción quirúrgica del dispositivo y cultivo de muestras de las vegetaciones, con aislamiento de Pseudomonas spp. Se administró terapia antimicrobiana sobre la base del antibiograma y el paciente evolucionó satisfactoriamente. Se debe pensar en esta enfermedad ante todo paciente con marcapasos que presente fiebre y sintomatología general, una vez que se han descartado otros posibles focos de infección; además, se debe actuar rápido para lograr un tratamiento adecuado.


ABSTRACT Infections due to cardiovascular devices are becoming more frequent. Here is presented the case of a 62-year-old male patient with fever and poor general condition, who had been intervened seven years ago for the implantation of a pacemaker. In the blood tests, leukocytosis and hemoglobin below 10 g/L were observed. The echocardiogram showed a pacemaker electrode in the right cavities with multiple echo-dense masses indicating infectious endocarditis. A surgical extraction of the device was performed as well as culture of vegetation samples with the isolation of Pseudomonas spp. An antimicrobial therapy was provided on the basis of the antibiogram, and the patient progressed satisfactorily. This clinical entity should be considered in any patient with a pacemaker who presents fever and general symptoms, once other possible sources of infection are ruled out; in addition to acting quickly in order to achieve an adequate treatment.


Assuntos
Marca-Passo Artificial , Pseudomonas , Endocardite não Infecciosa
8.
Arch. argent. pediatr ; 115(5): 291-293, oct. 2017. ilus
Artigo em Espanhol | LILACS, BINACIS | ID: biblio-887379

RESUMO

La ataxia-telangiectasia es una entidad caracterizada por un cuadro de ataxia cerebelosa progresiva, telangiectasias, defectos inmunológicos y una mayor tendencia al desarrollo de tumores malignos. La mutación genética responsable (ataxia-telangiectasia mutada) parece jugar un papel importante en la función celular normal y el remodelado cardiovascular. Se describe la aparición de una arritmia maligna en un paciente de 14 años con un diagnóstico de ataxia-telangiectasia, en remisión completa de linfoma no Hodgkin B de alto grado. Consultó en el Servicio de Urgencias Pediátricas por episodios de presíncope, y se observó, al ingresar, bloqueo auriculoventricular completo que evolucionó hacia asistolia, por lo que requirió la colocación de un marcapasos definitivo. Las dosis acumuladas de fármacos cardiotóxicos recibidos fueron de bajo riesgo. Sin embargo, es posible que esta enfermedad degenerativa crónica afecte con el tiempo al tejido de citoconducción. En la bibliografía revisada, no existen o se desconocen reportes previos de arritmias malignas en pacientes con ataxia-telangiectasia.


Ataxia-telangiectasia is a disorder characterized by cerebellar ataxia, telangiectasia, immunodeficiency, and increased predisposition to cancer susceptibility. Mutations in the ataxia telangiectasia mutated gene seem to play an important role in normal cell function and in cardiovascular remodeling. We report a case of a 14-year-old boy with ataxia-telangiectasia and high-grade B-non-Hodgkin lymphoma who remained in continuous complete remission after chemotherapy and who was admitted into our Emergency Room presenting with episodes of presyncope. At admission he presented a complete atrioventricular block that evolved into asystole and required placement of a pacemaker. Cumulative cardiotoxic drugs received were at low risk. However, it is possible that this chronic degenerative disease may affect the cardiac conduction system over time. In the reviewed literature there are no or unknown reports of ataxia-telangiectasia with malignant cardiac arrhythmias.


Assuntos
Humanos , Masculino , Adolescente , Ataxia Telangiectasia/complicações , Parada Cardíaca/etiologia , Bloqueio Cardíaco/etiologia
9.
Arch. méd. Camaguey ; 20(2): 135-144, mar.-abr. 2016.
Artigo em Espanhol | LILACS | ID: lil-780710

RESUMO

Fundamento: los avances en los diseños de los marcapasos y su simplificación en la técnica de implantación, han permitido que la estimulación eléctrica del corazón sea una práctica habitual en gran número de hospitales provinciales. Objetivo: describir los resultados de la implantación de marcapasos permanente. Métodos: se realizó un estudio descriptivo, retrospectivo a un universo de 2 590 pacientes, a quienes se les implantó o cambió los marcapasos permanentes, en el Hospital Universitario Manuel Ascunce Domenech, desde enero de 2002 hasta enero de 2015. La información obtenida se procesó mediante el programa estadístico SPSS-19.0 para Windows y estadística descriptiva con distribución de frecuencia y porcientos. Los resultados del estudio se expusieron en tablas y gráficos. Resultados: 2 590 pacientes fueron sometidos al proceder (primoimplante 71, 5 % y recambio 28, 5 %). El rango de edad fluctúo entre 14 y 102 años, con un promedio de edad de 74, 6. La vía de abordaje para introducir el electrodo que predominó fue la disección de la vena cefálica (1 905 eletrodos-90, 1 %). EL síncope en 969 (52, 3 %) de los casos, el bloqueo auriculoventricular en 1 219 (65, 8 %) y la posible fibrosis del sistema de conducción en 897 (48, 4 %), fueron las principales causas del motivo del implante. El modo de estimulación VVI se utilizó en 1 714 enfermos (72, 3 %) y el DDD en 384 (14, 8 %). La principal causa del recambio del dispositivo fue el agotamiento por fin de vida de la batería en 692 casos (93, 9 %). Las complicaciones relacionadas con el proceder fueron en 124 pacientes (4, 8 %). Conclusiones: debe aumentarse el consumo de marcapasos estimado por millón de habitantes en la provincia de Camagüey, así como el modo de estimulación DDD. La implantación es segura en esta provincia.


Background: breakthroughs in the design of pacemakers and their simplification in implantation techniques allow the electric stimulation of the heart to be a usual practice in many provincial hospitals. Objective: to describe the results of permanent pacemaker implantation. Methods: a retrospective and descriptive review between January, 2002 and 2015 was performed. The universe included 2 590 patients, who had their permanent pacemakers implanted or changed at Manuel Ascunce Domenech Hospital. The information obtained was processed with SPSS-19.0 statistical program for Windows and descriptive statistic with frequency distribution and percentage. The results of the review were shown in tables and graphs. Results: 2 590 patients underwent the procedure (first implantation 71, 5 % and reimplantation 28, 5 %). Age range fluctuated between 14 and 102 years, with an age average of 74, 6. The dissection of the cephalic vein (1905 electrodes- 90, 1 %) was the predominant approach to introduce the electrode. Syncope in 969 (52, 3 %) of the cases, atrioventricular block in 1 219 (65, 8 %), and the possible fibrosis of the heart´s conducting system in 897 (48, 4 %) were the main causes of the implantation. VVI stimulation mode was used in 1 714 patients (72, 3 %) and DDD in 384 (14, 8 %). The main cause of the device reimplantation was dead batteries in 692 cases (93, 9 %). Complications related to the procedure arose in 124 patients (4, 8 %). Conclusions: consumption of pacemakers estimated per million inhabitants in the province of Camaguey should be increased along with DDD pacing mode. The implantation is safe in this province.

10.
Arch. méd. Camaguey ; 20(2): 145-157, mar.-abr. 2016.
Artigo em Espanhol | LILACS | ID: lil-780711

RESUMO

Fundamento: actualmente la infección de la bolsa del marcapasos permanente se trata mediante técnicas percutáneas o cirugía cardíaca a cielo abierto, la primera no es una práctica habitual y la segunda muchas veces está contraindicada. Objetivo: valorar la respuesta a la aplicación de una nueva alternativa de intervención en la infección de la bolsa del marcapasos. Métodos: se realizó un estudio de intervención, cuasiexperimental modalidad grupo único. El universo estuvo constituido por 28 pacientes que ingresaron con el diagnóstico de infección de la bolsa del marcapasos, posterior a los seis meses de realizado la implantación, en el Hospital Universitario Manuel Ascunce Domenech, de 2008 a enero 2015. La información obtenida se procesó mediante el programa estadístico SPSS-19.0 para Windows y estadística descriptiva con distribución de frecuencia y porcientos. Los resultados del estudio se expusieron en tablas. Resultados: 28 pacientes fueron sometidos a la nueva alternativa de intervención, con un rango de edad entre 51 y 93 años, con una media de 78, 5 años. Predominó el sexo femenino, 17 pacientes (60, 7 %). La necrosis por presión en nueve pacientes, 32, 1 %, fue el mayor factor predisponente; la infección tuvo mayor relación con el cambio del marcapasos, 26 pacientes (92, 9 %); así como la necrosis séptica 20 pacientes (71, 4 %) fue la forma clínica de presentación más incidente. El staphylococcus epidermidis se aislóen 11 pacientes (39, 3 %). No hubo complicaciones durante el acto quirúrgico y los 28 pacientes (100 %) sometidos a la intervención cumplieron los criterios de curación. Conclusión: la alternativa de intervención en la infección de la bolsa del marcapasos propuesta, es una opción segura y viable en el tratamiento de estos pacientes, y a la vez una variante en sustitución de las técnicas percutáneas o cirugía abierta.


Background: nowadays, permanent pacemaker pocket infection is treated with percutaneous techniques or open heart surgery. The former is not a usual practice and the latter is mostly contraindicated. Objective: to assess the response to the application of a new alternative in surgery of the pacemaker pocket infection. Methods: a unique group quasi-experimental intervention study was conducted after six years of the implantation, at the Manuel Ascunce Domenech Hospital, from January 2008 to January 2015. The universe was composed of 28 patients who were admitted and diagnosed with pacemaker pocket infection. The information obtained was processed through SPSS-19.0 statistical program for Windows, and descriptive statistics with distribution of frequency and percentage. The results of the study were reported in tables. Results: the 51 to 93 age group of twenty-eight patients went through the new alternative of intervention, with an average of 78, 5 years old. Female sex was predominant, 17 patients (60, 7%). Pressure necrosis in nine patients, 32, 1%, was the most predisposing factor. The infection was more related to the change of pacemaker, 26 patients (92, 9%), and septic necrosis (20 patients, 71, 4%) was the most influential clinical presentation form. The staphylococcus epidermidis was isolated in 11 patients (39, 3%). There were no complications during the surgical procedure and the 28 patients (100%) who underwent surgery stuck to the treatment criteria. Conclusion: the proposed alternative of intervention in pacemaker pocket infection is a save and viable option in the treatment of these patients, as well as a variant in the substitution of percutaneous techniques or open surgery.

11.
Iatreia ; 28(2): 198-201, abr.-jun. 2015. ilus, tab
Artigo em Espanhol | LILACS, COLNAL | ID: lil-747610

RESUMO

El síndrome de Twiddler es una complicación infrecuente de los dispositivos de estimulación eléctrica cardíaca; a pesar de su rareza merece ser tenido en cuenta al evaluar pacientes con sospecha de disfunción del marcapasos. Presentamos el caso de un paciente de 62 años portador de marcapasos biventricular quien ingresó al Hospital Universitario San Vicente Fundación por insuficiencia cardíaca descompensada debida a síndrome de Twiddler. Los síntomas se resolvieron con el implante de una nueva terminal de resincronización cardíaca.


Twiddler's syndrome is a rare complication of cardiac conduction devices; despite its low frequency, it should be considered when evaluating patients with suspicion of pacemaker's dysfunction. We report the case of a 62 year old man who consulted Hospital Universitario San Vicente Fundación, in Medellín, Colombia, with decompensated heart failure due to dislodgement of the left ventricle lead of his recently implanted biventricular pacemaker. The patient improved with the placement of a new device.


A síndrome de Twiddler é uma complicação infrequente dos dispositivos de estimulação elétrica cardíaca; apesar de sua raridade merece ser tido em conta ao avaliar pacientes com suspeita de disfunção do marca-passos. Apresentamos o caso de um paciente de 62 anos portador de marca- passos biventricular/desfibrilador quem ingressou ao Hospital Universitário San Vicente Fundação por insuficiência cardíaca descompensada devido a síndrome de Twiddler. Os sintomas se resolveram com o implante de um novo terminal de re-sincronização cardíaca.


Assuntos
Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Síndrome
12.
CCH, Correo cient. Holguín ; 17(4): 443-451, oct.-.-dic. 2013. tab
Artigo em Espanhol | LILACS | ID: lil-696659

RESUMO

Introducción: la terapia con marcapasos constituye un tratamiento eficaz y óptimo para los pacientes con bradiarritmias severas, la cual mejora su pronóstico y calidad de vida. Objetivo: describir las características clínico-epidemiológicas de los pacientes sometidos a implantación de marcapasos definitivos. Métodos: se realizó un estudio retrospectivo de serie de casos en 860 pacientes que recibieron un marcapasos entre enero de 2007 y diciembre de 2009. Se recogieron los datos generales, indicaciones, proceder quirúrgico, modalidad de estimulación, vías de implantación, tiempo quirúrgico, complicaciones y procedencia. Los datos obtenidos fueron reflejados en tablas. Resultados: predominó el grupo de 60-79 años para ambos sexos con el 51,7%; el bloqueo aurículo-ventricular de tercer grado fue la indicación más común (50%), seguida por la enfermedad del nódulo sinusal (37%); los primoimplantes constituyeron el 88,3% y los recambios el 11,7%. La modalidad unicameral con el 67% y el modo VVI-VVIR con el 53% fueron las indicaciones más comunes. Las complicaciones graves aparecieron en el 0,9% y sin fallecidos; la implantación por vena cefálica con el 64,2% y un tiempo quirúrgico entre 30-60 minutos para el 64,2% predominó en esta serie. En la cirugía ambulatoria reportó más del 40% de los casos. Conclusiones: en Holguín continúan incrementándose los pacientes con necesidad de estimulación eléctrica permanente, con predominio de los ancianos con disociación aurículo-ventricular y enfermedad del nodo sinusal, las complicaciones graves fueron escasas y sin fallecidos. Se recomienda perfeccionar el trabajo del equipo para brindar un servicio de alta calidad.


Introduction: pacemaker therapy is an effective and optimal treatment for patients with severe bradyarrhythmia, which improves prognosis and quality of life. Objective: to describe the clinical and epidemiological characteristics of patients undergoing pacemaker implantation. Methods: a retrospective and series of cases study in 860 patients who received a pacemaker between January 2007 and December 2009 was carried out. Data were collected through indications, surgical procedure, and type of stimulation, implementation pathways, surgical time, complications and origin. The data were showed in tables. Results: the age group between 60-79 years of both sexes prevailed (51.7%), the atrioventricular block third degree was the most common indication (50%), followed by sick sinus syndrome (37%); first implants accounted for 88.3% and 11.7% spares. The unicameral mode with 67% and VVI - VVIR with 53% were the most common indications. Serious complications were at 0.9% and no deaths were reported, the cephalic vein implantation to 64.2% and operating time between 30-60 minutes for 64.2% predominated in this series. Outpatient surgery reported in over 40% of cases. Conclusions: the number of patients requiring electrical stimulation continues to increase in Holguín, elderly patients predominated with atrioventricular complete and sinus node disease, and good results have been obtained with few complications and deaths were not reported. The authors recommended to improve the work of the surgical team to provide high quality service.

14.
Arch. méd. Camaguey ; 16(5): 566-578, sep.-oct. 2012.
Artigo em Espanhol | LILACS | ID: lil-665633

RESUMO

La implantación de marcapasos endocárdicos definitivos puede acompañarse de complicaciones sépticas que ensombrecen su pronóstico, de ahí la importancia de suestudio. Objetivo: describir el comportamiento de las complicaciones sépticas de los marcapasos endocárdicos definitivos, en pacientes del Centro de Atención Cardiovascular de Camagüey, entre el año 2001 y el 2009. Método: se realizó un estudio descriptivo transversal en un universo de 49 pacientes con complicaciones sépticas, cuyo registro secundario fue la historia clínica y el libro de registro de implantación de marcapasos y las variables estudiadas fueron: grupos de edades, sexo, tipo de complicaciones sépticas, gérmenes, sensibilidad antimicrobiana, tipo de marcapaso más propenso a complicarse y vía deimplantación. Los datos fueron procesados de forma computarizada y se empleó la estadística descriptiva mediante el uso de medidas deresumen absolutas y relativas. Resultados: predominaron las complicaciones sépticas en el grupo de 60 años y más. La sepsis de la herida quirúrgica y la del bolsillo fueron las más frecuentes, el germen predominante fue Estafilococo aureo y la mayoría de los gérmenes desarrollaron resistencia. Prevalecieron los marcapasos complicados bicamerales y los implantados por punción venosa. Conclusiones: las complicaciones sépticas observadas predominaron en los pacientes mayores de 60 años, en los marcapasos bicamerales e implantados por punción venosa. El germen más frecuente fue Estafilococo aureo y se observó resistencia al tratamiento y multidrogoresistencia


Definite endocardial pacemaker implantation may be accompanied by septic complications that darken its prognosis, hence the importance of its study. Objective: to describe the behavior of septic complications ofdefinite endocardial pacemakers in patients at the Cardiovascular Care Center in Camagüey, from 2001 to 2009. Method: a crosssectional descriptive study was conducted in a universe of 49 patients with septic complications, whose secondary record was their medical histories and the register of pacemaker implantation, the studied variables were: age group, sex, type of septic complications, germs, antimicrobial susceptibility, type of pacemaker most prone to complicate and way of implementation. Data were computer operated, descriptive statistics through absolute and relative summary measures were used. Results: septic complications in the group of 60 years and older prevailed. Surgical wound sepsis and the one from the pocket were the most frequent, aswell as Staphylococcus aureus germ, most of the germs showed resistance. Venipuncture and dual chamber complicated pacemakers prevailed. Conclusions: septic complicationspredominated in patients over than 60 years, regarding dual chamber and venipuncture pacemaker. Staphylococcus aureus was themost frequent germ, resistance to treatment was observed


Assuntos
Humanos , Idoso , Marca-Passo Artificial , Complicações Pós-Operatórias , Sepse/complicações , Estudos Transversais , Epidemiologia Descritiva
15.
Arch. méd. Camaguey ; 16(5): 637-643, sep.-oct. 2012.
Artigo em Espanhol | LILACS | ID: lil-665640

RESUMO

Fundamento: el marcapasos es un dispositivo electrónico generador de impulsos que excita artificial y rítmicamente el corazón cuando los marcapasos naturales del mismo no pueden mantener adecuadamente el ritmo y la frecuencia. Además monitorizan la actividad eléctrica cardíaca espontánea, y según su programación desencadenan impulsos eléctricos o no. Caso clínico: se presenta el caso de un paciente masculino de 72 años de edad con antecedentes de hipertensión arterial para lo cual lleva tratamiento farmacológico con enalapril 20mg y clortalidona 25mg diarios; se le implantó un marcapaso monocameral con censado y estimulación ventricular hace dos años por presentar bloqueo aurículo-ventricular completo, acudió a consulta de programación de marcapasos del Servicio de Cardiología del Hospital Universitario Manuel Ascunce Domenech, de Camagüey por presentar palpitaciones y vértigos; al realizarle electrocardiograma de superficie se observó la existencia de estimulación bicameral, se programó para realizar exploración quirúrgica electiva y se detectó la rotura del aislante del electrodo responsable de la fuga con estimulación auricular.


Background: a pacemaker is an electronic device that generates impulses to control the rate of the heart´s muscular contractions when the natural heart's pacemaker is no longer able to regulate rhythm and frequency. It also monitors spontaneous electrical activity of the heart and according to its programming triggers electrical impulses or not. Case report: a 72-year-old male patient presented with a history of high-blood pressure that was treated with enalapril 20mg and chlorthalidona 25mg daily. This patient was implanted a single chamber pacemaker with census and ventricular stimulation two years ago by suffering from complete atrioventricular block. The patient was present at the pacemaker programming consultation in the Cardiology Center at the Teaching Hospital Manuel Ascunce Domenech in Camaguey, complaining of palpitations and dizziness. Bicameral stimulation was observed in the electrocardiography; therefore the patient was scheduled to perform elective surgical exploration during which was detected the wire-electrode's insulator broken, which is responsible for the leak with atrial stimulation.

16.
Rev. ANACEM (Impresa) ; 6(2): 80-83, ago. 2012. tab, graf
Artigo em Espanhol | LILACS | ID: lil-687052

RESUMO

INTRODUCCIÓN: La implantación de marcapasos definitivo se realiza en portadores de alteraciones en la generación del impulso cardíaco y/o con trastornos de la conducción. OBJETIVO: Caracterizar el perfil clínico-epidemiológico de los pacientes portadores de marcapasos definitivo en la Unidad de Cardiología del Hospital Regional de La Serena, en el período julio - septiembre de 2011. MATERIAL Y MÈTODO: Estudio descriptivo, de corte transversal. Se revisaron 103 fichas clínicas de pacientes marcapaso definitivo mediante muestreo aleatorio en la Unidad de Cardiología del Hospital Regional de La Serena. Se incluyeron pacientes mayores de 15 años con trastornos en generación del impulso y/o conducción irreversible. Se recopilaron y analizaron datos mediante Microsoft Excel 2007, identificándose características como sexo, edad, ruralidad, comorbilidades, manifestaciones clínicas, presencia o ausencia de Enfermedad de Chagas y cardiopatía específica. Se consideró significativo un p<0,05. RESULTADOS: Del total de 103 pacientes, 47,1 por ciento fueron mujeres. La edad promedio fue 74,5 +/- 12 años. La ruralidad fue de 49,51 por ciento Las manifestaciones clínicas más frecuentes fueron síncope (37,24 por ciento), disnea (32,34 por ciento) y mareos (24,46 por ciento). Del total de pacientes, 22 por ciento presentaron serología positiva para Tripanosoma Cruzi, 38 por ciento negativa y 40 por ciento sin serología. DISCUSIÓN: La principal causa de indicación de marcapasos definitivo fue el bloqueo auriculoventricular completo, correlacionándose con la literatura. No se encontró significancia estadística entre la severidad de la clínica y tipo de trastorno de la conducción. Se observó significancia estadística en la asociación entre ruralidad y serología para Tripanosoma Cruzi positiva y/o sin serología.


INTRODUCTION: The implant of definitive pacemaker is indicated in electrical impulse generation disorders and/or hearth electrical conduction abnormalities. OBJETIVE: Characterize clinically and epidemiologically the profile of patients with definitive pacemaker in the Cardiology Unit of the La Serena Regional Hospital, between July and September 2011. MATERIAL AND METHOD: Descriptive transversal cut study. 103 medical records of DPM diagnosed patients were analyzed by simple random sampling in the Cardiology Unit of the La Serena Regional Hospital. Patients with electrical impulse generation disorders and/or hearth electrical conduction abnormalities aged > 18 years old were included. Data collecting and analyzing were realized by Microsoft Excel 2007. The studied variables included: sex, age, rurality, disease, clinical symptoms, presence or absence of Chagas Disease and cardiopathies. Odss Ratio (OR) was calculated in significant differences situations in order to evaluate risk associated. A p< 0.05 was considered significant. RESULTS: Of the total of patients, 47.1 percent was women. The average age was 74.5 +/- 12 years. Rurality condition was 49.51 percent Most frecuent clinical symptoms were syncope (37.24 percent), dyspnoea (32.34 percent), dizziness (24.46 percent).Of 103 patients, 22 percent tested positive for Tripanosoma Cruzi, 38 percent tested negative and 40 percent without serology test. DISCCUSSION: The main definitive pacemaker indication was Complete Atrioventricular block, wich agree the literature. The association between clinical severity and hearth conduction abnormality type was not significant. We observed statistically significant differences between rurality condition and positive and/or without serologic test for Tripanosoma Cruzi.


Assuntos
Humanos , Masculino , Adulto , Feminino , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Cardiopatias/epidemiologia , Cardiopatias/terapia , Marca-Passo Artificial/estatística & dados numéricos , Distribuição por Idade e Sexo , Chile , Comorbidade , Estudos Transversais , Doença de Chagas/epidemiologia , Marca-Passo Artificial/microbiologia , Sorologia , Trypanosoma cruzi/isolamento & purificação
17.
Arch. méd. Camaguey ; 16(1): 53-61, ene.-feb. 2012.
Artigo em Espanhol | LILACS | ID: lil-628109

RESUMO

Con la variante a la técnica de implante de marcapasos a la hora de confeccionar el bolsillo se reduce el tamaño de la incisión y se simplifica el cierre de la herida.Objetivo: mostrar variante de la técnica en la confección clásica del bolsillo del marcapasos. Método: se realizó un estudio descriptivo retrospectivo en un grupo básico de trabajo del servicio de cardiología del Hospital Universitario Manuel Ascunce Domenech de Camagüey, desde enero de 2003 hasta diciembre de 2010. El universo de estudio lo constituyeron 1540 pacientes a los que se les implantó marcapasos. La muestra no aleatoria la constituyeron 598 pacientes. Resultados: predominó el sexo masculino y las edades sobre los 60 años, con 80 implantes como promedio anual. Del total, predominó el implante primario y los generadores monocámaras. Las complicaciones se presentaron en el orden del 1.82 por ciento.Conclusiones: con esta variante técnica para la confección del bolsillo se disminuyó el tamaño de la herida


With the variant to the technique of pacemaker implant, when preparing the pacemaker pocket, the size of the incision is reduced and it is simplified the wound closure. Objective: to show the technical variant in the classical pacemaker pockets manufacture. Method: a retrospective descriptive study was conducted in a basic working group of the Cardiology service at the University Hospital Manuel Ascunce Domenech of Camaguey, from January 2003 to December 2010. The universe of study was constituted by 1540 patients who were implanted pacemakers. Non-random sampling was constituted by 598 patients. Results: male sex and the age group of 60 years predominated, with 80 implants as an annual average. From the total, primary implant and single chamber generators prevailed. The complications were presented in the order of the 1.82 percent. Conclusions: this technical vapercentiant for the pocket manufacturing was reduced the size of the wound


Assuntos
Humanos , Idoso , Masculino , Feminino , Marca-Passo Artificial , Procedimentos Cirúrgicos Cardíacos/métodos , Epidemiologia Descritiva , Estudos Retrospectivos
18.
Rev. eletrônica enferm ; 13(4): 735-742, out.-dez. 2011. tab
Artigo em Português | LILACS, BDENF | ID: lil-693794

RESUMO

Este estudo teve como objetivo avaliar a qualidade de vida (QV) de cardiopatas pós-implante de marcapasso (MP) de uma cidade no interior de Goiás / Brasil. Estudo de intervenção tipo antes e depois. Vinte e três pacientes portadores de MP cardíaco foram avaliados antes e após implante de MP. Os instrumentos utilizados foram o AQUAREL associado ao SF-36. Houve predomínio de indivíduos do sexo feminino (65%), com idade média de 64,9 anos, e baixa escolaridade (43%). Os domínios que evidenciaram melhor QV, através do instrumento AQUAREL, foram desconforto no peito (M=71,60) e arritmia (M=70,87) e menor para dispneia ao exercício (M=61,81). Na comparação de QV antes e após o implante de MP, observou-se melhora significativa nos domínios do SF-36: capacidade funcional, dor, estado geral de saúde, aspecto social e aspecto emocional. De forma geral, os resultados do SF-36 indicam que houve melhora da qualidade de vida após implante de MP.


This study aimed to evaluate the quality of life (QOL) of patients after artificial cardiac pacemaker (PM) implantation in a small city of Goiás/Brazil. This is a before-after trial. Twenty-three patients were evaluated before and after PM implantation. The instruments used were AQUAREL and SF-36. Most of patients were female (65%) with a mean age of 64.9 years, and low formal education (43%). The areas of AQUAREL with better QOL were chest discomfort (M = 71.60) and arrhythmia (M=70.87); the lower areas were exercise dyspnea (M = 61.81). Comparing QOL before and after PM implantation according to SF-36, there was significant improvement in the areas: physical functioning, pain, general health and emotional and social aspects. Globally, the results of SF-36 indicated improvement in quality of life after PM implantation.


Este estudio tuvo como objetivo evaluar la calidad de vida (CV) de cardiópatas post-implantación de marcapasos cardíacos (MP) de una ciudad del interior de Goiás/Brasil. Intervención del estudio de antes y después. Veintitrés pacientes con MP cardiaco fueron evaluados antes y después de la implantación del MP. Los instrumentos utilizados fueron asociados AQUAREL con el SF-36. Predominó personas del sexo femenino (65%) con edad media de 64,9 y con baja escolaridad (43%). Las áreas donde se evidenció mejor CV, por intermedio del AQUAREL, fueron de malestar en el pecho (M=71.60) y arritmia (M=70.87) e inferior para los disnea de esfuerzo (M=61.81). Al comparar CV entre el antes y después de la implantación MP, se observó una mejoría significativa en las áreas del SF-36: funcionamiento físico, dolor corporal, salud general, los aspectos emocionales y sociales. En general,los resultados indicanuna mejora en lacalidad de vidadespués de la implantaciónPM.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Qualidade de Vida , Avaliação em Enfermagem
19.
Arq. bras. cardiol ; 97(5): e113-e120, nov. 2011. tab
Artigo em Português | LILACS | ID: lil-608945

RESUMO

A estimulação cardíaca artificial por meio de marca-passo cardíaco representa uma das alternativas mais promissoras no tratamento das arritmias, entretanto pode ocasionar reações singulares ou complexas, precoces ou tardias. Neste estudo, objetivou-se descrever as evidências científicas sobre o risco de infecção e formação de biofilme associado ao marca-passo cardíaco. Trata-se de um estudo de revisão integrativa da literatura. Totalizaram-se 14 publicações classificadas em três categorias temáticas: diagnóstico (microbiológico e/ou clínico), complicações e terapêutica das infecções. Os Staphylococcus epidermidis e os Staphylococcus aureus foram os microrganismos mais frequentemente isolados. Não foi possível determinar a incidência da infecção associada aos marca-passos, uma vez que os estudos eram em geral de prevalência. Em termos de terapêutica destacou-se a remoção completa dos marca-passos, especialmente nos casos de suspeita de biofilme. Ainda é controverso o uso da profilaxia antibiótica sistêmica na redução da incidência da infecção associada ao implante de marca-passo.


Cardiac pacing through cardiac pacemaker is one of the most promising alternatives in the treatment of arrhythmias, but it can cause reactions natural or complex reactions, either early or late. This study aimed to describe the scientific evidence on the risk of infection and biofilm formation associated with cardiac pacemaker. This is a study of integrative literature review. It included 14 publications classified into three thematic categories: diagnosis (microbiological and/or clinical), complications and therapy of infections. Staphylococcus epidermidis and Staphylococcus aureus were the microorganisms most frequently isolated. It was not possible to determine the incidence of infection associated with pacemakers, since the studies were generally of prevalence. In terms of therapy, the complete removal of pacemakers stood out, especially in cases of suspected biofilm. Still controversial is the use of systemic antibiotic prophylaxis in reducing the incidence of infection associated with implantation of a pacemaker.


La estimulación cardíaca artificial por medio de marcapaso cardíaco representa una de las alternativas más promisorias en el tratamiento de las arritmias, sin embargo, puede ocasionar reacciones singulares o complejas, precoces o tardías. En este estudio, el objetivo fue describir las evidencias científicas sobre el riesgo de infección y formación de biofilm asociado al marcapaso cardíaco. Se trata de un estudio de revisión integrante de la literatura. Se totalizaron 14 publicaciones clasificadas en tres categorías temáticas: diagnóstico (microbiológico y/o clínico), complicaciones y terapéutica de las infecciones. Los Staphylococcus epidermidis y los Staphylococcus aureus fueron los microorganismos más a menudo aislados. No se pudo determinar la incidencia de la infección asociada a los marcapasos, pues los estudios eran en general de prevalencia. En términos de terapéutica se destacó la retirada completa de los marcapasos, especialmente en los casos en que se sospechaba de biofilm. Todavía es algo controvertido el uso de la profilaxis antibiótica sistémica para la reducción de la incidencia de la infección asociada al implante de marcapaso.


Assuntos
Humanos , Infecções Bacterianas/microbiologia , Biofilmes/crescimento & desenvolvimento , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/microbiologia , Infecções Bacterianas/terapia , Infecções Relacionadas à Prótese/terapia
20.
Arq. bras. cardiol ; 93(2): 167-173, ago. 2009. graf, tab
Artigo em Inglês, Espanhol, Português | LILACS | ID: lil-528321

RESUMO

FUNDAMENTO: A estimulação de ventrículo direito pode ser deletéria em pacientes com disfunção ventricular, entretanto há poucas evidências sobre o impacto dessa estimulação em pacientes com função normal. OBJETIVO: Avaliar a evolução clínica e laboratorial de pacientes com função ventricular normal submetidos a implante de marcapasso cardíaco artificial. MÉTODOS: Foram estudados de forma prospectiva 16 pacientes com os seguintes critérios de inclusão: função ventricular normal definida pelo ecocardiograma e presença de estimulação ventricular superior 90 por cento (avaliação por telemetria do gerador). Parâmetros analisados: classe funcional (CF), teste de caminhada, dosagem de BNP, ecocardiograma (convencional e parâmetros de dessincronia intraventricular e teste de qualidade de vida (SF36). Essas medidas fora feitas com 10 dias(d) (t1), 120d(t2) e 240 d(t3). Os dados foram comparados ao longo do tempo segundo método ANOVA. Comparações múltiplas de médias foram efetuadas utilizando-se o método de Tukey. RESULTADOS: Dos dados avaliados os seguintes não apresentaram variação estatística significante (p>0,05): classe funcional, dosagem de BNP, parâmetros ecocardiográficos convencionais, dessincronia intraventricular (Doppler tecidual). Apresentaram piora (p<0,05) o teste de caminhada (entre t2 e t3) e o tempo entre a contração septal e a parede posterior do ventrículo esquerdo, porém sem preencher critérios de dessincronia. Avaliação de qualidade de vida (SF36) mostrou melhora na capacidade funcional, nos aspectos sociais e estado geral de saúde. CONCLUSÃO: Após oito meses, em pacientes com função normal não foram evidenciadas alterações clínicas (CF e SF 36) e laboratoriais (ecocardiografia convencional, parâmetros de dessincronia e dosagem de BNP); entretanto, houve piora no teste de caminhada.


BACKGROUND: The stimulation of the right ventricle (RV) may be deleterious in patients with ventricular dysfunction; however there is little evidence about the impact of this stimulation in patients with normal ventricular function. OBJECTIVES: To assess the clinical and laboratory evolution of patients with normal ventricular function submitted to implant of artificial cardiac pacemaker (PM). METHODS: 16 patients enrolled according to the following inclusion criteria: normal ventricular function defined by echocardiogram and presence of upper ventricular stimulation > 90 percent (generator telemetry assessment) submitted to a PM implant were prospectively studied. The following parameters were assessed: Functional Class (FC), walk test, BNP levels, echocardiography evaluation (conventional and intraventricular dyssynchrony) and quality of life test (SF36). The patients were assessed after 10 (t1), 120 (t2) and 240 days (t3). Data was compared throughout time according to ANOVA. Multiple comparisons of means were performed through Tukey's test. RESULTS: Among the assessed data, the following did not present significant statistic variation (p> 0.05): functional class, BNP levels, conventional echocardiographic parameters, intraventricular dyssynchrony (tissue Doppler). The walk test (between t2 and t3) and the time between septal contraction and LV posterior wall showed worsening (p<0.05), although they did not meet the dyssynchrony criteria. The quality of life assessment (SF36) showed improvement in the functional capacity, social aspects, and general status sub-items. CONCLUSION: After 8 months, patients with normal ventricular function did not show clinical (FC and SF36) or laboratory alterations (conventional echocardiography, dyssynchrony parameters and BNP levels); however, there was a worsening in the walk test.


FUNDAMENTO: La estimulación del ventrículo derecho puede ser dañosa a pacientes con disfunción ventricular. Sin embargo, hay pocas evidencias sobre el impacto de esa estimulación en pacientes con función normal. OBJETIVO: Evaluar la evolución clínica y laboratorial de pacientes con función ventricular normal sometidos a implante de marcapaso cardíaco artificial. MÉTODOS: Se estudiaron de forma prospectiva a 16 pacientes con los siguientes criterios de inclusión: función ventricular normal definida por el ecocardiograma y presencia de estimulación ventricular superior a 90 por ciento (evaluación por telemetría del generador). Parámetros analizados: clase funcional (CF), test de marcha, dosificación de BNP, ecocardiograma (convencional y parámetros de desincronía intraventricular y prueba de calidad de vida (SF36). Esas mediciones se hicieron con 10 días(d) (t1), 120d(t2) y 240 d(t3). Los datos se compararon a lo largo del tiempo según el método ANOVA. Comparaciones múltiples de promedios se efectuaron utilizándose el método de Tukey. RESULTADOS: Desde los datos evaluados, los siguientes no presentaron variación estadística significante (p>0,05): clase funcional, dosificación de BNP, parámetros ecocardiográficos convencionales, desincronía intraventricular (Doppler tisular). Presentaron empeoramiento (p<0,05) el test de marcha (entre t2 y t3) tiempo entre la contratación septal y la pared posterior del ventrículo izquierdo, pero sin atender a criterios de desincronía. La evaluación de calidad de vida (SF36) evidenció mejora en la capacidad funcional, en los aspectos sociales y en el estado general de salud. CONCLUSIÓN: Tras ocho meses en pacientes con función normal no se evidenciaron alteraciones clínicas (CF y SF 36) y laboratoriales (ecocardiografía convencional, parámetros de desincronía y dosificación de BNP); no obstante, hubo empeoramiento en el test de marcha.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Função Ventricular Direita/fisiologia , Ecocardiografia Doppler de Pulso , Métodos Epidemiológicos , Teste de Esforço , Peptídeo Natriurético Encefálico/sangue , Qualidade de Vida , Caminhada/fisiologia