Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Rev. Fac. Odontol. (B.Aires) ; 39(91): 41-48, 2024. ilus
Artigo em Espanhol | LILACS | ID: biblio-1554951

RESUMO

La microtomografía es un estudio que utiliza la ra-diación X para obtener imágenes de tamaños de mi-lésimas de milímetros y de alta resolución. Las imá-genes 2D son procesadas por diferentes softwares para lograr obtener volúmenes capaces de ser ana-lizados tridimensionalmente. La microtomografía es el estudio de elección a la hora de evaluar caracte-rísticas muy pequeñas con gran precisión. La obtu-ración endodóntica buscar lograr un sellado que no tenga espacios vacíos dentro de la masa de obtura-ción. Esto es importante debido a que los poros pue-den permitir, si están en contacto con la pared den-tinaria, la entrada de microorganismos al conducto radicular. El objetivo de este trabajo fue describir el procedimiento para el análisis y visualización de los espacios vacíos dentro de la obturación endodónti-ca, utilizando la microtomografía de rayos x, y esta-blecer un protocolo para ser utilizado por cualquier investigador(AU)


Microtomography is a study that uses X-radiation to obtain high-resolution images of sizes of thousandths of millimeters. The 2D images are processed by different software to obtain volumes capable of being analyzed three-dimensionally. Microtomography is the study of choice when evaluating very small features with great precision. Endodontic filling seeks to achieve a seal that does not have voids within the filling obturation. This is important because the voids can allow, if they are in contact with the dentin wall, the entry of microorganisms into the root canal. The objective of this work was to describe the procedure for the analysis and visualization of voids within the endodontic filling using microtomography and to establish the protocol to be used by any researcher (AU)


Assuntos
Obturação do Canal Radicular/efeitos adversos , Protocolos Clínicos , Microtomografia por Raio-X/métodos , Porosidade , Imageamento Tridimensional/métodos , Infiltração Dentária/prevenção & controle
2.
Acta odontol. latinoam ; 36(3): 163-168, Dec. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1533522

RESUMO

ABSTRACT Root canal morphology and its anatomical variations pose a great challenge to endodontists Aim The aim of this in silico study was to perform a qualitative and quantitative analysis of the threedimensional morphological characteristics of the isthmus in the mesial root canals of mandibular molars using microcomputed tomography (micro-CT) Material and Method Six hundred first mandibular molars were selected, including 317 with two mesial canals with isthmuses between the canals, and fully formed root. Isthmus morphology was determined in 3D longitudinal sections using Fan et al. (2010) classification. Root length, and the volume and area of apical and coronal level were measured. Additionally, the structural model index (SMI) of the canals were also assessed Results The prevalence of isthmuses in the mesial root canals was 32% type II, 29% type III, 22% type IV, and 17% type I. The root length was found to be 9.1±0.5 mm, the volume and area, of all root canal system, were 41.8±40.1 mm3 and 63.6±24.2 mm2 respectively. The isthmi volume and area alone were 11.06±9.03 mm3 and 30.02±11.02 mm2. The study confirmed that isthmuses are present in mesial canals of mandibular first molars, being more frequent in the apical third Conclusion The high prevalence of isthmuses with complex morphological features underscores the importance of using intracanal medications to disinfect areas unprepared by instruments.


RESUMO A morfologia do canal radicular e suas variações anatômicas representam um grande desafio para os endodontistas. O objetivo deste estudo ex vivo foi realizar uma análise qualitativa e quantitativa das características morfológicas tridimensionais do istmo nos canais mesiais de molares inferiores por meio de microtomografia computadorizada (micro-CT) Material e Método Foram selecionados 600 primeiros molares inferiores, incluindo 317 com dois canais mesiais com istmos e raiz totalmente formada. A morfologia do istmo foi determinada em cortes longitudinais 3D usando a classificação Fan et al. (2010). Foram mensurados o comprimento da raiz, o volume e a área apical e coronal e da cavidade pulpar. Adicionalmente, também foram avaliados o structure model index (SMI) dos canais Resultados A prevalência de istmos nos canais mesiais foi de 32% tipo II, 29% tipo III, 22% tipo IV e 17% tipo I. O comprimento da raiz foi de 9,1±0,5 mm, o volume e a área de todo o sistema de canais radiculares foram de 41.8±40.1 mm3 e 63.6±24.2 mm2, respectivamente. O volume e área do istmo isoladamente foram 11.06±9,03 mm3 e 30.02±11.02 mm2. O estudo confirmou que os istmos estão presentes em canais mesiais dos primeiros molares inferiores, sendo mais frequentes no terço apical Conclusão A alta prevalência de istmos com características morfológicas complexas ressalta a importância do uso de medicação intracanal para desinfecção de áreas não tocadas por instrumentos.

3.
Acta odontol. latinoam ; 36(3): 177-182, Dec. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1533524

RESUMO

ABSTRACT Current instrumentation systems cannot fully prepare oval root canal systems. This may cause accumulation of hard tissue debris and fail to eliminate bacteria from areas inaccessible to instrumentation, which could perpetuate periapical inflammation and jeopardize the success of endodontic treatment Aim To evaluate the performance of two endodontic systems in oval canals by investigating the changes in volume, unprepared areas, and centering ability of XP-endo Shaper (XPS) and WaveOne Gold (WOG) in oval canals using microcomputed tomography (micro-CT) Materials and Method Thirty mandibular canines were scanned before and after preparation with WOG (25/.07 and 35/.06) or XPS (30/.01) to evaluate the volume, surface area, and canal centralization at 4 mm and 10 mm from the apical foramen Results Volume and surface area increased significantly after preparation with both systems (p<0.05). However, no significant difference was observed in the unprepared areas, regarding either the entire canal (26.21% for WOG and 30.10% for XPS), or the apical segment (18.82% for WOG and 14.63% for XPS) (p >0.05) Conclusions Both systems maintained canal centralization, with no difference between them. XPS and WOG had similar shaping abilities in the mandibular canine, but left almost one third of the unprepared areas.


RESUMO Os sistemas de instrumentação atuais são incapazes de preparar completamente os sistemas de canais radiculares do canal oval, o que pode levar ao acúmulo de detritos de tecido duro e manter micro-organismos em áreas inacessíveis à instrumentação. Essas bactérias poderiam perpetuar a inflamação periapical e comprometer o sucesso do tratamento endodôntico Objetivo Para avaliar o comportamento de dois sistemas endodônticos em canais ovais, esse estudo investigou as alterações no volume, áreas não preparadas e capacidade de centralização do XP-endo Shaper (XPS) e do WaveOne Gold (WOG) em canais ovais usando microtomografia computadorizada (micro-CT) Material e métodos Trinta caninos inferiores foram escaneados antes e depois do preparo com WOG (25/.07 e 35/.06) ou XPS (30/.01) para avaliar o volume, a área de superfície e a centralização do canal a 4 mm e 10 mm do forame apical Resultados O volume e a área de superfície aumentaram significativamente após o preparo com ambos os sistemas (p<0,05). No entanto, não foram observadas diferenças significativas nas áreas não preparadas, não apenas em todo o canal (26,21% para WOG e 30,10% para XPS), mas também no segmento apical (18,82% para WOG e 14,63% para XPS) (p >0,05) Conclusão Ambos os sistemas mantiveram a centralização do canal, sem diferenças entre eles. O XPS e o WOG tiveram habilidades de modelagem semelhantes no canino mandibular, mas deixaram quase um terço das áreas do canal sem preparo.

4.
Odovtos (En línea) ; 25(3): 32-42, Sep.-Dec. 2023. tab, graf
Artigo em Inglês | LILACS, BBO, SaludCR | ID: biblio-1529067

RESUMO

Abstract The aim of this study was to compare the filling capacity in curved root canal using a new continuous wave of condensation technique (Termo Pack II, Easy Dental Equipments, Brazil) or lateral compaction. The percentage of voids in the filling of mesial root canals of mandibular molars was assessed by micro-computed tomography (micro-CT). Mesial root canals (n=24) of mandibular molars with a degree of curvature between 20° and 40° were prepared using rotary system (ProDesign Logic, Easy, Brazil) up to #35, .05 taper. The root canals were filled by using the continuous wave of condensation system or lateral compaction and AH Plus sealer (n=12). Scanning at 9 µm was performed after preparation and after filling by using micro-CT SkyScan 1176. The volumetric percentage of filling material and voids (total length and in each root canal third) were calculated. Data were analyzed using ANOVA/ Tukey and Student's t tests (α=0.05). Before the filling techniques, the root canals volume after preparation was similar (p>0.05). The root canals filled by the continuous wave of condensation technique presented the lowest percentage of voids, and the greatest percentage of filling material in total length and thirds (cervical, middle and apical) (p<0.05). Both techniques were not able of completely filling the root canals. The continuous wave of condensation technique Termo Pack II promoted better root canal filling in curved root canals, when compared with lateral compaction.


Resumen El objetivo de este estudio fue comparar la capacidad de obturación en conductos radiculares curvos utilizando una nueva técnica de condensación de onda continua (Termo Pack II, Easy Dental Equipments, Brasil) vs compactación lateral. El porcentaje de brechas en la obturación de los conductos radiculares mesiales de los molares mandibulares se evaluó mediante microtomografía computarizada (micro-CT). Se prepararon conductos radiculares mesiales (n=24) de molares mandibulares con un grado de curvatura entre 20° y 40° utilizando un sistema rotatorio (ProDesign Logic, Easy, Brasil) al #35, conicidad 0,05. Los conductos radiculares se obturaron utilizando un sistema de condensación de onda contínua o compactación lateral y cemento AH Plus (n=12). Se realizó un escaneo de 9 µm después de la preparación y después de la obturación usando el micro-CT SkyScan 1176. Se calculó el porcentaje volumétrico de material de obturación y vacíos (longitud total y en cada tercio del conducto radicular). Los datos se analizaron utilizando las pruebas ANOVA/Tukey y t de Student (α=0,05). Antes de las técnicas de obturación, el volumen de los conductos radiculares después de la preparación fue similar (p>0,05). Los conductos radiculares obturados con la técnica de condensación por onda contínua presentaron el menor porcentaje de vacíos y el mayor porcentaje de material de obturación en longitud total y en tercios (cervical, medio y apical) (p<0,05). Ambas técnicas no fueron capaces de llenar completamente los conductos radiculares. La técnica de condensación de onda contínua Termo Pack II promovió un mejor relleno del conducto radicular en conductos radiculares curvos en comparación con la compactación lateral.


Assuntos
Obturação do Canal Radicular/instrumentação , Condensação , Polpa Dentária , Microtomografia por Raio-X/instrumentação
5.
Odovtos (En línea) ; 25(2)ago. 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1448747

RESUMO

The aim of this study was to assess the influence of micro-computed tomography (micro-CT) voxel size on evaluation of root canal preparation using rotary heat-treated nickel-titanium files. Curved mesial root canals of mandibular molars were prepared using ProDesign Logic 30/.05 (PDL) or HyFlex EDM 25/.08 (HEDM) (n=12). The specimens were scanned using micro-CT with 5μm of voxel size before and after root canal preparation. Images with sub-resolution of 10 and 20μm voxel sizes were obtained. The percentage of volume increase, debris and uninstrumented root canal surface were analyzed in the different voxel sizes. Data were compared using unpaired Student's t-test and ANOVA statistical tests (α=0.05). No differences were observed for percentage of volume increase, debris and instrumented surface between the root canals prepared by PDL and HEDM (p>0.05). Both systems promoted higher percentage of debris in the apical third compared to the middle third (p0.05). PDL and HEDM had similar root canal preparation capacity. Micro-CT images using different voxel sizes did not influence the results of volume increase and debris evaluation. However, images at 5µm showed greater accuracy to evaluate the percentage of uninstrumented surfaces.


El objetivo de este estudio fue evaluar la influencia del tamaño de vóxel de la microtomografía computarizada (micro-CT) en la evaluación de la preparación del conducto radicular utilizando limas rotatorias de níquel-titanio tratadas térmicamente. Se prepararon conductos radiculares mesiales curvos de molares mandibulares usando ProDesign Logic 30/.05 (PDL) o HyFlex EDM 25/.08 (HEDM) (n=12). Las muestras se escanearon usando micro-CT con un tamaño de vóxel de 5μm antes y después de la preparación del conducto radicular. Se obtuvieron imágenes con subresolución de vóxeles de 10 y 20μm. Se analizó el porcentaje de aumento de volumen, residuos y superficie del conducto radicular no instrumentado en diferentes tamaños de vóxel. Los datos se compararon usando la prueba t de Student no pareada y las pruebas estadísticas ANOVA (α=0,05). No se observaron diferencias en el porcentaje de aumento de volumen, detritus y superficie instrumentada entre los conductos radiculares preparados por PDL y HEDM (p>0,05). Ambos sistemas promovieron un mayor porcentaje de detritos en el tercio apical en comparación con el tercio medio (p0,05). PDL y HEDM tenían una capacidad de preparación del conducto radicular similar. Las imágenes de micro-CT que utilizan diferentes tamaños de vóxel no influyeron en los resultados de la evaluación del volumen y los desechos. Sin embargo, las imágenes de 5µm mostraron una mayor precisión al evaluar el porcentaje de superficies no instrumentadas.

6.
São José dos Campos; s.n; 2023. 77 p.
Tese em Português | LILACS, BBO | ID: biblio-1427407

RESUMO

Uma vez que o estresse crônico pode estimular o sistema nervoso simpático, diminuindo a resposta imune, favorecendo a perda óssea frente a um processo inflamatório, os objetivos deste estudo foram: 1) Avaliar os efeitos de modelos de indução de estresse no desenvolvimento da periodontite apical (P.a) e avaliar o nível de estresse gerado pelos mesmos; 2) A partir do melhor protocolo de estresse obtido foi avaliado o perfil inflamatório da PA induzida em animais sob condições de estresse, utilizando sistemicamente a Sinvastatina, Propranolol e a Sinvastatina associada ao propranolol. Na primeira parte foram utilizados 32 ratos Wistar (N=8) divididos aleatoriamente em: SE: sem estresse, sem periodontite apical (P.a); SE+P.a: sem estresse, com P.A; EP+P.a: Estresse previsível + P.a; EI+P.a: estresse imprevisível + P.a. Os animais foram submetidos ao estresse crônico por 42 dias sendo que no dia 21 foi induzida a P.a. Para comprovação do estresse foram utilizadas análises de peso e comportamentais de campo aberto (CA) e labirinto em y (Y). Foram realizadas análises micro tomográfica e histológica para avaliar o efeito de ambas as metodologias sobre a progressão da P.a. Os dados foram avaliados estatisticamente. Observou-se que não houve diferença no ganho de peso entre os animais SE e SE+P.a. Em relação aos grupos estressados o grupo estresse imprevisível apresentou menor ganho de peso quando comparado ao grupo sem estresse. Nos testes comportamentais, Y e CA observou-se um mesmo padrão de comportamento nos animais do grupo SE e SE+P.a (p>0.05). Verificou-se diferenças entre os grupos SE+P.a e EI +P.a no volume da lesão periapical, mas não houve diferença entre os protocolos de estresse. A Análise histológica mostrou maior área de P.a nos animais do grupo EI+P.a o que também foi observado pela análise microtomográfica. Na segunda etapa foram utilizados 48 animais divididos em 5 grupos (N=8): SE+P.a: sem estresse e com P.a; E+SS: Estresse + Periodontite Apical + soro; E+SN: Estresse + Periodontite Apical + Sinvastatina; E+P: Estresse + Periodontite Apical + Propranolol e S+SN+P: Estresse + Periodontite Apical + Sinvastatina + Propranolol. O protocolo de estresse utilizado foi o estresse crônico imprevisível por 42 dias. Realizou-se análises de peso e comportamentais de labirinto em y e campo aberto. Após a eutanásia foram realizadas as análises microtomográfica e a análise histológica e histomorfométrica. Os valores obtidos foram analisados estatisticamente.Observouse que todos os grupos medicados apresentaram ganho de peso maior do que o grupo solução salina. No grupo Sinvastatina e no grupo Propranolol, os animais apresentaram maior atividade locomotora do que no grupo Solução salina. O volume da P.a foi significativamente menor nos grupos Sinvastatina e Propranolol quando comparado ao grupo solução salina. Na análise histológica observou-se que a área da lesão foi significativamente menor nos animais do grupo Sinvastatina quando comparado ao da solução salina, bem como menor intensidade e extensão do infiltrado inflamatório. Concluindo-se que o estresse crônico imprevisível aumenta a perda óssea periapical em animais com PA induzida. Além disso, concluiu-se que tanto a Sinvastatina quanto o Propranolol reduze o estresse crônico, reduzindo a perda óssea nestes animias (AU)


Since chronic stress can stimulate the sympathetic nervous system, decreasing the immune response, favoring bone loss in the face of an inflammatory process, the objectives of this study were: 1) To evaluate the effects of stress induction models on the development of apical periodontitis (P.a) and assess the level of stress generated by them; 2) Based on the best stress protocol obtained, the inflammatory profile of BP induced in animals under stress conditions was evaluated, systemically using Simvastatin, Propranolol and Simvastatin associated with propranolol. In the first part, 32 Wistar rats (N=8) were randomly divided into: SE: without stress, without apical periodontitis (P.a); SE+P.a: without stress, with P.A; EP+P.a: Predictable stress + P.a; EI+P.a: unpredictable stress + P.a. The animals were subjected to chronic stress for 42 days, and on the 21st, P.a. To prove the stress, weight and behavioral analyzes of open field (CA) and maze in y (Y) were used. Micro tomographic and histological analyzes were performed to evaluate the effect of both methodologies on the progression of P.a. Data were statistically evaluated. It was observed that there was no difference in weight gain between SE and SE+P.a animals. In relation to the stressed groups, the unpredictable stress group showed less weight gain when compared to the non-stress group. In the behavioral tests, Y and CA, the same pattern of behavior was observed in animals from the SE and SE+P.a groups (p>0.05). There were differences between groups SE+P.a and EI +P.a in the volume of the periapical lesion, but there was no difference between the stress protocols. The histological analysis showed a greater area of P.a in the animals from the EI+P.a group, which was also observed by the microtomographic analysis. In the second stage, 48 animals were divided into 5 groups (N=8): SE+P.a: without stress and with P.a; E+SS: Stress + Apical Periodontitis + serum; E+SN: Stress + Apical Periodontitis + Simvastatin; E+P: Stress + Apical Periodontitis + Propranolol and S+SN+P: Stress + Apical Periodontitis + Simvastatin + Propranolol. The stress protocol used was unpredictable chronic stress for 42 days. Weight and behavioral analyzes of y-maze and open field were performed. After euthanasia, microtomographic analysis and histological and histomorphometric analysis were performed. The values obtained were statistically analyzed. It was observed that all medicated groups had greater weight gain than the saline group. In the Simvastatin group and in the Propranolol group, the animals showed greater locomotor activity than in the Saline group. The BP volume was significantly lower in the Simvastatin and Propranolol groups when compared to the saline group. In the histological analysis, it was observed that the area of the lesion was significantly smaller in the animals of the Simvastatin group when compared to the saline solution, as well as lower intensity and extension of the inflammatory infiltrate. Concluding that unpredictable chronic stress increases periapical bone loss in animals with induced AP. In addition, it was concluded that both Simvastatin and Propranolol reduce chronic stress, reducing bone loss in these animals. (AU)


Assuntos
Animais , Ratos , Periodontite Periapical , Sistema Nervoso Simpático , Aumento de Peso , Sinvastatina
7.
Revista Naval de Odontologia ; 49(1): 19-26, 2022/07/04.
Artigo em Português, Inglês | LILACS-Express | LILACS | ID: biblio-1379020

RESUMO

The objective of this study was to conduct a systematic review focused on studies that used micro-computed tomography (micro-CT) analysis to evaluate untouched canal areas after root canal preparation with continuous rotary and reciprocating kinematics. Electronic search strategies were used in LILACS, PubMed (MedLine), Science Direct, Cochrane, Scopus and Web of Science databases. An additional search for gray literature was performed on Google Scholar, OpenGrey and ProQuest. In addition, manual searches were performed on the reference list of included articles. It covered studies in English, Portuguese and Spanish, without restriction regarding the publication time. The articles selected for inclusion in this review meet all the following criteria: in vitro studies that evaluated, with the use of micro-CT, the percentage of untouched areas after root canal preparation comparing rotary and reciprocating kinematics. A total of 11 studies were selected for qualitative and quantitative analysis. One study showed that the Reciproc system has a smaller percentage of untouched channel walls in lower incisors when compared to BioRace system. Another study showed no significant differences between reciprocating systems Reciproc and WaveOne with BioRace in mesial root canals of lower molars. Similarly, they did not observe any difference between ProTaper Next and ProTaper Universal with WaveOne. A single study showed differences between XP-Endo Shaper system (rotary) compared with WaveOne Gold. The studies evaluated in the present review showed by micro-CT that none of the instrumentation systems, regardless of the kinematics used or NiTi heat treatment, was able to completely touch the root canal walls.


O objetivo deste estudo foi realizar uma revisão sistemática dos estudos que avaliaram por microtomografia computadorizada (micro - CT) as áreas não tocadas do canal radicular após o preparo com cinemática rotatória continua e reciprocante. Foram utilizadas estratégias eletrônicas de busca nas bases LILACS, PubMed (MedLine), Science Direct, Cochrane, Scopus e Web of Science. Uma busca adicional por literatura cinzenta foi realizada no Google Scholar, OpenGrey e ProQuest. A busca abrangeu estudos em inglês, português e espanhol, sem restrição em relação ao tempo de publicação. Adicionalmente, pesquisas manuais foram realizadas na lista de referências dos artigos incluídos. Os artigos selecionados foram estudos in vitro que avaliaram por micro - CT a porcentagem de áreas não tocadas após o preparo do canal radicular, comparando as cinemáticas rotatórias e reciprocante. No total 11 estudos foram selecionados para análise qualitativa e quantitativa. Um estudo mostrou que o sistema Reciproc (reciprocante) tem uma porcentagem menor de paredes não tocadas do canal em incisivos inferiores, quando comparado com o sistema BioRace (rotatório). Outro estudo não mostrou diferenças significativas entre os sistemas reciprocantes Reciproc e WaveOne e o sistema BioRace em canais radiculares mesiais de molares inferiores. Da mesma forma, não foram observadas diferenças entre ProTaper Next, ProTaper Universal (rotat órios) e WaveOne. Um único estudo apresentou diferenças entre as cinemáticas, XP - Endo Shaper (rotatório) mostrou maior porcentagem de áreas tocadas quando comparado com TRUShape e WaveOne Gold. Os estudos avaliados mostraram que nenhum dos sistemas de instrumentação, independente da cinemática, foi capaz de tocar completamente as paredes dos canais radiculares.

8.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385888

RESUMO

ABSTRACT: This study aims to demonstrate, through a clinical case report, the applicability of the use of microtomography (µCT) in the histopathological evaluation of a ranula lesion on the oral floor and to evaluate the use of 2 % elemental iodine solution as a contrast agent, in order to obtain a better contrast effect in a tissue sample, thus facilitating the identificat ion of anatomical structures, the histomorphological evaluation and the potential use of µCT in the imaging diagnosis of lesions. Different parameters were evaluated for obtaining images in SkyScan 1172, in a biopsied piece, when impregnated in a 10 % formalin solution and in a 2 % elemental iodine solution, when impregnated for 24h and 48h. Contrast agent impregnation was evaluated using the Hounsfield unit. The use of µCT allowed the identification of sialoliths dispersed inside the biopsy specimen, while the impregnation with Elemental iodine 2 % for 24h resulted in a better contrast when compared to the other conditions. The use of the Hounsfield unit allowed an adequate evaluation of the contrast obtained when the different parameters of impregnation and image acquisition were applied. The comparison between the 3D images with and without a specific marker highlighted a better evidencing of the soft tissues, with an improvement in the contrast of the images, also allowing the ident ification of the glandular duct obstructed by the sialoliths, allowing a conclusive histopathological evaluation of the biopsied lesion.


RESUMEN: Este estudio tiene como objetivo demostrar, a través de un reporte de caso clínico, la aplicabilidad del uso de la microtomografía (µCT) en la evaluación histopatológica de una lesión de ránula en el piso de la cavidad oral y evaluar el uso de solución de yodo elemental al 2 % como agente de contraste, con el fin de obtener un mejor efecto de contraste en una muestra de tejido, facilitando así la identificación de estructuras anatómicas, la evaluación histomorfológica y el potencial uso de µCT en el diagnóstico por imágenes de lesiones. Se evaluaron diferentes parámetros para la obtención de imágenes en SkyScan 1172, en una pieza biopsiada, cuando se impregna en una solución de formalina al 10 % y en una solución de yodo elemental al 2 %, durante 24 h y 48 h. La impregnación del agente de contraste se evaluó utilizando la unidad Hounsfield. El uso de µCT permitió la identificación de sialolitos dispersos dentro de la muestra de la biopsia, mientras que la impregnación con Yodo Elemental al 2 % durante 24 h resultó en un mejor contraste en comparación con las otras condiciones. El uso de la unidad Hounsfield permitió una adecuada evaluación del contraste obtenido cuando se aplicaron los diferentes parámetros de impregnación y adquisición de imágenes. La comparación entre las imágenes 3D con y sin marcador específico destacó una mejor evidenciación de los tejidos blandos, con una mejora en el contraste de las imágenes, permitiendo además identificar el conducto glandular obstruido por los sialolitos, permitiendo una evaluación histopatológica concluyente de la lesión sometida a biopsia.

9.
Rio de Janeiro; s.n; 2022. 95 p.
Tese em Português | LILACS, BBO | ID: biblio-1554296

RESUMO

O conceito de Endodontia Minimamente Invasiva é amplo, e envolve não só a realização de acessos, mas também o uso de instrumentos com conicidades reduzidas ou geometrias inovadoras. Buscando avaliar se as estratégias minimamente invasivas adotadas apresentam vantagens frente aos tratamentos tradicionais, a presente tese foi dividida em três estudos. O estudo 1 avaliou a preservação da dentina perirradicular e o alargamento da porção apical dos canais de molares inferiores com instrumentos TruNatomy e ProTaper Gold. Para isso, vinte molares inferiores foram microtomografados, pareados e distribuídos em 2 grupos. No grupo ProTaper Gold, os canais mesial e distal foram preparados até os instrumentos F2 e F3, respectivamente, enquanto no grupo TruNatomy, os canais mesial e distal foram ampliados até os instrumentos prime e medium, respectivamente. Após um novo escaneamento, os parâmetros de instrumentação foram calculados. Os dados foram analisados pelos testes de Mann-Whitney, T Student e escalonamento multidimensional não-métrico. Não foram encontradas diferenças entre os grupos em relação à área não preparada e redução de espessura de dentina. O grupo ProTaper Gold removeu mais dentina que o TruNatomy no terço coronal das raízes mesiais. O estudo 2 avaliou a formação de microtrincas dentinárias em molares inferiores acessados de forma ultraconservadora (UltraAC), instrumentados com Reciproc e XP-Endo Shaper. Quarenta molares inferiores foram microtomografados, pareados e distribuídos em 4 grupos de acordo com o tipo de cavidade de acesso e protocolo do sistema de instrumentação: tradicional/Reciproc; tradicional/XP-endo Shaper; UltraAC/Reciproc e UltraAC/XP-endo Shaper. Após os preparos dos canais, os dentes foram escaneados novamente e as imagens transversais das raízes mesiais e distais, do nível da furca ao ápice foram avaliadas com o objetivo de identificar a presença de microtrincas dentinárias. Em todos os grupos, as microtrincas verificadas nas imagens pós-operatórias já estavam presentes no exame pré-operatório. O estudo 3 avaliou a influência de instrumentos com o mesmo diâmetro de ponta e diferentes conicidades no percentual de área não preparada e volume de dentina removida após o preparo dos canais mesiovestibular e distovestibular de molares superiores com ou sem o canal mesiovestibular 2 (MV2). Vinte e dois molares superiores foram selecionados, microtomografados, pareados e classificados em dois grupos, de acordo com a anatomia das raízes: dentes com MV2 e dentes sem MV2. Após o acesso, os canais radiculares foram preparados com instrumentos 25/.01, 25/.03, 25/.05, 25/.06 e 25/.08v. Os dentes foram submetidos a novos escaneamentos por micro-CT após preparo com cada instrumento descrito anteriormente. Os dados foram analisados usando o Modelo linear generalizado misto e aproximação de Kenward-Roger para testes Wald F. Em dentes com e sem canais MV2, a porcentagem de área não preparada apresentou uma diminuição significativa ao longo do tratamento após cada instrumento utilizado e a porcentagem de dentina removida apresentou um aumento significativo ao longo do tratamento. Com base nos estudos, concluiu-se que as estratégias minimamente invasivas adotadas não apresentaram vantagens frente aos tratamentos tradicionais(AU)


The concept of Minimally Invasive Endodontics is broad, and involves not only the realization of accesses, but also the use of instruments with reduced tapers or innovative geometries. Seeking to assess whether the minimally invasive strategies adopted have advantages over traditional treatments, this thesis was divided into three studies. Study 1 evaluated the preservation of periradicular dentin and enlargement of the apical portion of the mandibular molar canals prepared with TruNatomy and ProTaper Gold instruments. For this, twenty lower molars were microtomography, paired and divided into 2 groups. In the ProTaper Gold group, the mesial and distal canals were prepared up to the F2 and F3 instruments, respectively, while in the TruNatomy group, the mesial and distal canals were prepared up to the prime and medium instruments, respectively. After a new scan, the instrumentation parameters were calculated. Data were analyzed by Mann-Whitney, T Student and non-metric multidimensional scaling tests. No differences were found between groups regarding unprepared area and dentin thickness reduction. The ProTaper Gold group removed more dentin than TruNatomy in the coronal third of the mesial roots. Study 2 evaluated the formation of dentinal microcracks in mandibular molars accessed by ultraconservative cavites (UltraAC), instrumented with Reciproc and XP-Endo Shaper. Forty lower molars were microtomography, paired and divided into 4 groups according to the type of access cavity and instrumentation system protocol: traditional/Reciproc; traditional/XP-endo Shaper; UltraAC/Reciproc and UltraAC/XP-endo Shaper. After the root canal preparations, the teeth were scanned again and the transverse images of the mesial and distal roots, from the furcation level to the apex, were evaluated in order to identify the presence of dentinal microcracks. In all groups, the microcracks seen in the postoperative images were already present in the preoperative examination. Study 3 evaluated the influence of instruments with the same tip diameter and different tapers on the percentage of unprepared area and volume of dentin removed after preparation of the mesiobuccal and distobuccal canals of maxillary molars with or without the mesiobuccal canal 2 (MV2). Twenty-two maxillary molars were selected, microtomography, paired and classified into two groups, according to root anatomy: teeth with MV2 and teeth without MV2. After access, the root canals were prepared with instruments 25/.01, 25/.03, 25/.05, 25/.06 and 25/.08v. The teeth were rescanned by micro-CT after preparation with each instrument described above. Data were analyzed using the Generalized Linear Mixed Model and Kenward-Roger approximation for Wald F tests. In teeth with and without MV2 canals, the percentage of unprepared area showed a significant decrease throughout the treatment after each instrument used and the percentage of removed dentin showed a significant increase during treatment. Based on the studies, it was concluded that the minimally invasive strategies adopted did not present advantages over traditional treatments(AU)


Assuntos
Humanos , Masculino , Preparo de Canal Radicular/métodos , Microtomografia por Raio-X , Dente Molar/diagnóstico por imagem , Preparo de Canal Radicular/instrumentação , Cavidade Pulpar
10.
Rev. odontol. UNESP (Online) ; 51: e20220045, 2022. ilus
Artigo em Português | LILACS, BBO | ID: biblio-1424231

RESUMO

Introdução: o desafio no uso do Micro-Ct tem sido estabelecer e padronizar padrões adequados para escaneamento e tratamento das imagens, para que se obtenha o máximo desempenho do equipamento, e permitir a comparação dos achados entre diferentes estudos. Objetivo: o presente estudo tem como objetivo comparar a porcentagem de volume ósseo em regiões com perda óssea periodontal utilizando diferentes metodologias para definição da área a ser analisada (ROI). Material e método: dez ratos foram submetidos à indução de doença periodontal, e, após a eutanásia, as mandíbulas foram escaneadas com cortes de 9 µ e 18 µm de espessura, com passo de rotação de 0.3mm. As imagens foram reconstituídas utilizando o software NRecon, e em seguida, utilizando o software CTAnalyser - CTAn, foram definidas as áreas de interesse (ROI) ao redor dos segundos molares. A primeira área de interesse (ROI1) foi definida em um padrão retangular que se restringiu às regiões interproximais e furca, onde a área total de tecido ósseo foi obtida somando os resultados dos 3 ROIs. A segunda área (ROI2) foi definida no sentido corono/apical ao redor do segundo molar até suas limitações proximais com os dentes vizinhos, onde a porcentagem de tecido ósseo pertencente às raízes foram excluídas das avaliações. As análises foram realizadas com cinco diferentes valores de thresholds (130-50, 130-60, 130-70, 130-80, 130-90 e 130-100). Resultado: a análise entre os diferentes ROIs demonstrou que em ambas as análises foi observada a tendência a menor porcentagem de tecido ósseo quanto maior o contraste de tons de cinza utilizado, no entanto, nos resultados obtidos no ROI2 essa diferença não foi estatisticamente significante. Conclusão: com os resultados obtidos pode se concluir que a utilização de diferentes thresholds para quantificação óssea, em áreas onde houve doença periodontal, pode trazer resultados divergentes; a definição da área de interesse interfere com os resultados obtidos e que a obtenção de uma área de interesse com a remoção das raízes mostrou-se menos susceptível à variação dos parâmetros de escaneamento.


Introduction: the challenge in the use of Micro-Ct has been to establish and standardize adequate standards for scanning and image processing to obtain the maximum performance of the equipment and to allow the comparison of findings between different studies. Objective: this study aims to compare the percentage of bone volume in regions with periodontal bone loss using different methodologies to define the area to be analysed (ROI). Material and method: ten rats were submitted to periodontal disease induction, and, after euthanasia, the mandibles were scanned with slices of 9µ and 18 µm thickness, with a rotation step of 0.3mm. The images were reconstructed using the NRecon software, and then, using the CTAnalyser - CTAn software, the areas of interest (ROI) around the second molars were defined. The first area of interest (ROI1) was defined in a rectangular pattern that was restricted to the interproximal and furcation regions, where the total area of bone tissue was obtained by adding the results of the 3 ROIs. The second area (ROI2) was defined in the coronal/apical direction around the second molar to its proximal limitations with the neighboring teeth, in which the percentage of bone tissue belonging to the roots was excluded from the evaluations. Analyses were performed with five different threshold values (130-50, 130-60, 130-70, 130-80, 130-90, and 130-100). Result: the analysis between the different ROIs showed that, in both analyses, there was a tendency towards a lower percentage of bone tissue the greater the grayscale contrast used. However, in the results obtained in ROI2, this difference was not statistically significant. Conclusion: with the results obtained, it can be concluded that the use of different thresholds for bone quantification, in areas where there was a periodontal disease, can bring divergent results; the definition of the area of ​​interest interferes with the results obtained; and that obtaining an area of interest with the removal of the roots, proved to be less susceptible to the variation of the scanning parameters.


Assuntos
Animais , Ratos , Doenças Periodontais , Periodontite , Perda do Osso Alveolar , Microtomografia por Raio-X , Mandíbula , Dente Molar , Análise de Variância
11.
Rev. odontol. UNESP (Online) ; 51: e20220047, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-1424238

RESUMO

Introduction: Primary stability is one of the goals of modern implant dentistry and if achieved, reduces treatment time for prosthetic rehabilitation and the number of interventions made in patients mouth. Several companies state as protocol for connical conection implants, a subcrestally positioning. Objective: This in vitro study aimed to evaluate the effect of placing a conical connection implant equicrestally and subcrestally on static and loading condition in two types of bone density. Material and method: A total of 200 bone cylinders were extracted from femur of pigs, standardized by means of x-rays and computerized microtomography scan (microCT) and separated in low and high density specimens. The implants were placed on the center of the bone cylinders and were evaluated before and after loading by means of microCT and histomorphometry. Result: The results showed that placing the evaluated implant subcrestally provided better primary stability and performance on static and loading situations on low and high density bone. Conclusion: Placing implant subcrestally improve primary stability outcomes under loading and static situations.


Introdução: A estabilidade primária é um dos objetivos da implantodontia moderna e, caso atingida, reduz o tempo de tratamento para a reabilitação protéticas e o número de intervenções realizadas. Diversas empresas preconizam a posição subcrestal no uso de implantes com conexão cônica interna. Objetivo: Este estudo in vitro avaliou o efeito do posicionamento de implantes de conexão conica interna sub e equicrestal sob condições estáticas e em função, considerando dois tipos de densidades ósseas. Material e método: um total de 200 espécimes de osso extraído do femur de suínos e padronizados por meio de radiografias e microtomografias computadorizadas foram separados em densidade alta e baixa. Implantes foram instalados no centro dos especimes e for a avaliados por meio de microCT e histomorfometria. Resultado: Os resultados demonstraram que a colocação de implante subcrestalmente promoveu melhor estabilidade primária e performance em todas as situações, irrespectivamente à densidade óssea. Conclusão: A colocação de implantes subcrestalmente melhora a estabilidade primária em todas as situações, sendo indicada quando da utilização de conexões cônicas internas.


Assuntos
Técnicas In Vitro , Densidade Óssea , Implantes Dentários , Microtomografia por Raio-X , Carga Imediata em Implante Dentário
12.
Rev. Fac. Odontol. (B.Aires) ; 37(86): 1-12, 2022. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1413026

RESUMO

El objetivo de este estudio fue evaluar con microto-mografía los poros existentes entre el cemento de resina, poste de fibra y paredes del conducto en los distintos tercios radiculares en premolares inferio-res. Se utilizaron 15 premolares inferiores unirra-diculares humanos recientemente extraídos. Se les realizó el tratamiento endodóntico, y se obturó con conos de gutapercha y cemento endodóntico a base de resina. Una vez desobturados se procedió a la ce-mentación de los postes. Cada muestra se posicionó en un accesorio personalizado y se escaneó utilizan-do un Microtomógrafo. Con el software CTAn v.1.12 (Bruker-microCT) se analizaron las microtomografías para obtener el volumen de interés (VOI) que permi-tió calcular el área de superficie (mm2) y volumen de cada poro (mm3) entre la dentina y el poste a nivel co-ronal, medio y apical. Los datos fueron analizados me-diante las pruebas estadísticas de Friedman o ANOVA de medidas repetidas. El volumen de los poros entre los tres tercios radiculares mediante la prueba de Friedman, encontró una diferencia global significativa (F = 30,00; p < 0,05). El tercio en donde los poros presentaron un mayor volumen (mm3) fue el tercio coronal (mediana: 0,29250), seguido por los tercios medio (mediana: 0,03200), y apical (mediana: 0,00140). La comparación de la superficie de los poros entre los 3 tercios brindó un resultado análogo al de la comparación del volumen. La mayor superficie (mm2) correspondió al tercio coronal (media ± DE = 1,66377 ± 0,27175), seguido por los tercios medio (media ± DE = 1,16210 ± 0,20343) y apical (media ± DE = 0,41074 ± 0,12641). La microtomografía permitió realizar un análisis cuantitativo y cualitativo de los poros en toda la muestra, sin deterioro de la misma. Se puede concluir que el tercio coronal presenta más poros que el tercio apical con la técnica de cementación utilizada. En cuanto a la superficie y volumen de los poros, los resultados encontrados son similares a los reporta-dos por diversos autores (AU)


The aim of this study was to evaluate with microtomography the existing pores between the resin cement, fiber post and canal walls in the different in thirds of the canal, in single-root lower premolars. Fifteen recently extracted human single root lower premolars were used, endodontically treated, and filled with gutta-percha cones and resin-based endodontic cement. Once unfilled, the posts were cemented. Each sample was positioned on a custom fixture and scanned using a Microtomograph. Each sample was evaluated using CTAn v.1.12 software (Bruker-microCT) to obtain the surface area (mm2), volume of interest (mm3) of each pore between dentin and post at the coronal, middle and apical levels. Data were analyzed using Friedman's tests or repeated measures ANOVA. The volume of the pores between the three root thirds using the Friedman test, a significant global difference was found (F = 30.00; p < 0.05). The third in which the pores presented a greater volume (mm3) was the coronal third (means: 0.29250), followed by the middle (means: 0.03200) and apical (means: 0.00140) thirds. The comparison of the pore surface between the 3 thirds gave an analogous result to that of the volume comparison. The largest surface area (mm2) corresponded to the coronal third (mean ± SD 1.66377 ± 0.27175), followed by the middle (mean ± 1.16210 ± 0.20343) and apical (mean ± 0.41074 ± 0.12641) thirds.Microtomography allowed a quantitative and qualitative analysis of the pores in the entire sample without deterioration. It can be concluded that the coronal third has more pores than the apical third with the cementation technique used. Regarding the surface and volume of the pores, the results found are similar to those reported by various authors (AU)


Assuntos
Porosidade , Técnica para Retentor Intrarradicular , Cimentação/instrumentação , Microtomografia por Raio-X , Dente Pré-Molar , Análise de Variância , Cimentos de Resina , Imageamento Tridimensional/métodos , Ácidos Fíbricos
13.
Dent. press endod ; 11(1): 72-77, Jan-Apr2021. Tab, Ilus
Artigo em Inglês | LILACS | ID: biblio-1348251

RESUMO

Introdução: O tipo de agulha e fluxo de irrigação é importante para a limpeza adequada no terço apical do canal radicular. Objetivo: Avaliar a influência do tipo de agulha e fluxo de irrigação na limpeza do canal radicular e canais laterais simulados e na extrusão apical do irrigante. Métodos: Trinta e dois dentes de resina foram utiliza- dos. Após a instrumentação do canal radicular, foram feitos quatro canais laterais a 2 e 7 mm do ápice. Os canais radiculares foram preenchidos com solução de contraste. Os canais foram irrigados com dois tipos de agulha, 29G e 31G, com diferentes designs (abertura lateral e apical) e dois fluxos (2 ou 5 mL/min), a 1 mm aquém do comprimento de trabalho. O volume da solução de contraste nos canais principal e laterais após irrigação e a extrusão apical do irrigante (mm3 ) foi avaliado por micro-CT, em comparação com a análise inicial. Os dados em porcentagem foram analisados pelos testes ANOVA e Tukey (α=0,05). Resultados: não houve diferença entre os protocolos de irrigação para limpeza da solução de contraste. Maior volume de extrusão apical com agulha 29G com abertura apical e 5 mL/min foi observado, em comparação ao mesmo tipo de agulha e 2 mL/min (p<0,05). Conclusão: Todos os protocolos de irrigação foram associados à limpeza dos canais radiculares. Maior extrusão apical foi observada com agulha 29G ­ abertura apical com maior fluxo de irrigação (5 mL/min). Implicações clínicas: Irrigação endodôntica com agulha com abertura apical e maior fluxo da solução pode favorecer a extrusão dos irrigantes para os tecidos periapicais (AU).


Introduction: needle and irrigation flow rate are important for proper cleaning of the root canal. Aim: to evaluate the influence of type of needle and irrigation flow rate on cleaning of root canal and simulated lateral canals and the apical extrusion of irrigant. Methods: Thirty-two resin teeth were used. After root canal instrumentation, four lateral canals were made at 2 and 7 mm from the apex. Root canals were filled with contrast solution. The root canals were irrigated with two types of needle, 29G and 31G, with different designs (side and apical opening) and two flow rates (2 or 5 mL/min), at 1 mm short of the working length. The volume of the contrast solution in the main and lateral canals after irrigation and apical extrusion of the irrigant (mm3) were evaluated by Micro-CT, in comparison with the initial analysis. Data in percentage were analyzed by ANOVA and Tukeys tests (α = 0.05). Results: no difference among the irrigation protocols for contrast solution cleaning was observed. Higher volume of apical extrusion using needle 29G-apical opening and 5 mL/min in comparison with the same type of needle and 2 mL/min was observed (p < 0.05). Conclusion: all irrigation protocols were associated with root canals cleaning. Greater apical extrusion was observed for needle 29G-apical opening with higher irrigation flow rate (5 mL/min). Clinical implications: endodontic irrigation using a needle with apical opening and higher flow rate of solution may favor extrusion of irrigant to the periapical tissues (AU).


Assuntos
Tecido Periapical , Irrigantes do Canal Radicular , Microtomografia por Raio-X , Agulhas , Cavidade Pulpar , Zeladoria
14.
Acta odontol. latinoam ; 34(1): 50-55, Apr. 2021. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1284934

RESUMO

ABSTRACT Dental anatomy can vary significantly between different populations from different countries. Dental anatomical variations are of great interest to the dental professional, especially to endodontists, since they can influence the outcome of endodontic treatment. The purpose of the present study was to describe the anatomical variations of the root canal in mandibular first premolars in a populationfrom Colombia, using micro-computed tomography. Fifty mandibular first premolars were scanned on a SkyScan 1174 and the microcomputed tomographic images were reconstructed. Anatomy was assessed using three-dimensional models. The parameters used were: Vertucci's classification, area and volume, perimeter, circularity, and major and minor diameter at 1, 2 and 3 mm from the apical foramen. According to the Vertucci's classification, teeth were classified as: types I (40%), V (24%), VII (4%) and III (4%), with 28% not classifiable. C-shaped canals were found in 1.8% of the sample. Mean evaluations at 1, 2, 3 mm of the foramen were as follows, respectively: perimeter 1.07 ± 0.57, 1.27 ± 0.78 and 1.57 ± 0.84 mm; circularity 0.59 ± 0.19, 0.57 ± 0.20 and 0.56 ± 0.22; maximum diameter 0.41 ± 0.23, 0.48 ± 0.33 and 0.60 ± 0.37 mm; minimum diameter 0.24 ± 0.10, 0.26 ± 0.11 and 0.21 ± 0.13 mm. Mean total area and volume were 61.27 ± 16.47 mm2 and 12.47 ± 4.95 mm3, respectively. There was wide anatomical variation in mandibular first premolars from Colombian individuals, reinforcing the need for proper anatomical knowledge to establish more effective strategies for endodontic treatment.


RESUMO A anatomia dentària pode variar significativamente entre diferentes populagoes, de diferentes países. As variagoes anatómicas dentais sao de grande interesse para o profissionai da odontologia, principalmente para os endodontistas, pois podem influenciar no resultado do tratamento endodóntico. Descrever as variagoes anatómicas do canal radicular dos primeiros pré-molares inferiores em uma populagao da Colómbia, usando a micro tomografia computadorizada. Cinquenta primeiros pré-molares inferiores foram digitalizados em um SkyScan 1174 e as imagens tomográficas foram reconstruidas e a anatomia foi avaliada por meio de modelos tridimensionais. Os parámetros utilizados foram: classificagao de Vertucci, área e volume, perímetro, circularidade e diámetros maior e menor a 1, 2 e 3 mm do forame apical. De acordo com a classificagao de Vertucci, os dentes foram classificados em: tipos I (40%), V (24%), VII (4%) e III (4%), sendo 28% nao classificáveis. Canais em forma de C foram encontrados em 1,8% da amostra. As avaliaçoes médias em 1, 2, 3 mm do forame foram as seguintes, respectivamente: perímetro 1,07 ± 0,57, 1,27 ± 0,78 e 1,57 ± 0,84 mm; circularidade 0,59 ± 0,19, 0,57 ± 0,20 e 0,56 ± 0,22; diámetro maior 0,41 ± 0,23, 0,48 ± 0,33 e 0,60 ± 0,37 mm; diámetro menor 0,24 ± 0,10, 0,26 ± 0,11 e 0,21 ± 0,13 mm. A média da área total e do volume foram 61,27 ± 16,47 mm2 e 12,47 ± 4,95 mm3, respectivamente. Houve uma grande variaçâo anatómica nos primeiros pré-molares inferiores de colombianos, reforçando a necessidade de conhecimento anatómico adequado para estabelecer estratégias mais eficazes para o tratamento endodóntico.

15.
Rio de Janeiro; s.n; 2021. 77 p.
Tese em Português | BBO, LILACS | ID: biblio-1525808

RESUMO

As cavidades de acesso dominaram a recente discussão sobre a Endodontia minimamente invasiva (EMI). No entanto, a rotulagem da EMI é mais ampla, envolvendo o uso de instrumentos com conicidades reduzidas ou geometrias inovadoras que permitam a remoção mínima de dentina. Além disso, aprimoramentos metodológicos têm sido sugeridos para mimetizar condições clínicas. Buscando responder algumas questões acerca da EMI, a presente tese é dividida em dois estudos. O estudo 1 avaliou a influência do acesso ultraconservador (UltraAC) na instrumentação, na qualidade da obturação e na capacidade máxima de carga para fratura em molares inferiores após o preparo do canal com o sistema XP-endo Shaper (XP) ou Reciproc (RC) em condições clínicas simuladas. Para isso, quarenta molares inferiores foram microtomografados e pareados em quatro grupos (n = 10), de acordo com o acesso e a instrumentação: TradAC/RC, TradAC/XP, UltraAC/RC e UltraAC/XP. Os dentes foram reescaneados e os parâmetros da instrumentação e obturação foram analisados. Os dentes foram restaurados e submetidos à ciclagem termomecânica e à capacidade máxima de carga para a fratura. O teste ANOVA foi usado para a análise estatística (P < 0,05). Os grupos TradAC apresentaram menor porcentagem (%) de área não preparada do que os grupos UltraAC (P < 0,05). O grupo UltraAC/XP apresentou a menor % de dentina removida (P < 0,05). A % de debris foi menor nos grupos UltraAC/XP e TradAC/XP do que no UltraAC/RC e TradAC/RC (P < 0,05). Os grupos UltraAC demonstraram maior % de espaços vazios e de material obturador na câmara pulpar (P < 0,05). Não houve diferença na capacidade máxima de carga para a fratura entre os grupos (P > 0,05). O estudo 2 avaliou o uso de instrumentos com conicidade reduzida - Bassi Logic ,03 (BL), com diferentes designs (XP) e como grupo de comparação o sistem Reciproc, na eficácia da instrumentação dos canais em condições clínicas simuladas. Vinte e quatro molares foram microtomografados, acessados de forma tradicional e divididos em três grupos (n = 8), de acordo com o preparo: BL, XP e RC. Nos grupos BL e RC, os canais mesiais foram instrumentados com 25/,03 ou R25 e o canal distal com 25/,03 e 40/,03 ou R25 e R40, respectivamente. No grupo XP, o mesmo instrumento foi utilizado em todos os canais (30/,04). Após o preparo, os dentes foram reescaneados e a % de área não preparada e de dentina removida foram avaliadas separadamente para os canais mesiais e distal. Os dados foram analisados com os testes ANOVA e de Tukey (P < 0,05). Verificou-se que o grupo BL apresentou maior % de área não preparada para ambos os canais em relação aos grupos XP e RC (P < 0,05). No entanto, não houve diferença na % de dentina removida entre os grupos (P > 0,05). Com base nos estudos, conclui-se que as estratégias minimamente invasivas adotadas no acesso e na instrumentação foram desvantajosas frente a tratamentos tradicionais, não justificando o seu uso(AU)


Access cavities have dominated the recent discussion on minimally invasive Endodontics (EMI). However, the issue of MIE is broader than access cavities, such as the use of instruments with reduced taper or innovative geometries that allow minimal dentin removal. Furthermore, methodological improvements have been suggested to mimic clinical conditions. Seeking to answer some questions about EMI, this thesis is divided into two studies. The first study evaluated the influence of ultraconservative access (UltraAC) on canal shaping, filling ability and maximum load capacity for fracture of mandibular molars after root canal preparation with XP-endo Shaper (XP) or Reciproc (RC), under simulated clinical conditions. Thus, forty mandibular molars were scanned and paired into four groups (n = 10), according to access and instrumentation protocol: TradAC/RC, TradAC/XP, UltraAC/RC and UltraAC/XP. Teeth were rescanned and the instrumentation and filling parameters were analyzed. The teeth were restored and submitted to thermomechanical cycling and maximum load capacity for the fracture. ANOVA test was used for statistical analysis (P < 0.05). The TradAC groups had a lower percentage (%) of unprepared area than the UltraAC groups (P < 0.05). The UltraAC/XP group had the lowest % of dentin removed (P < 0.05). The % of debris was lower in the UltraAC/XP and TradAC/XP groups than in the UltraAC/RC and TradAC/RC groups (P < 0.05). The highest % of voids and filling material in the pulp chamber was observed in the UltraAC groups (P < 0.05). There was no difference in the maximum load capacity for the fracture between the groups (P > 0.05). The second study evaluated the use of a reduced taper endodontic instrument system - Bassi Logic .03 taper (BL), expandable heat-treated system (XP) and, as comparison, the Reciproc system, on the ability to shape canals under simulated clinical conditions. For that, twenty-four mandibular molars were scanned and divided into three groups (n = 8), according to root canal instrumentation system: BL, XP and RC. In the BL and RC groups, the mesial canals were instrumented with 25/.03 or R25 and the distal canal with 25/.03 and 40/.03 or R25 and R40, respectively. In the XP group, the same instrument was used in all root canals (30/.04). After preparation, the teeth were rescanned and the % of unprepared area and dentin removed were evaluated separately for the mesial and distal canals. Data were analyzed using ANOVA and Tukey tests (P < 0.05). It was found that the BL group had a higher % of unprepared area for both root canals compared to the XP and RC groups (P < 0.05). However, there was no difference in the % of dentin removed between groups (P > 0.05). Based on the studies, it is concluded that there is no justification for the use of EMI since in general, UltraAC did not promote advantages over TradAC and the use of instruments with reduced taper resulted in a larger unprepared area, which could possibly influence the cleaning of the root canal system (AU)


Assuntos
Humanos , Masculino , Feminino , Procedimentos Cirúrgicos Minimamente Invasivos , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Resistência à Flexão , Microtomografia por Raio-X , Dente Molar
16.
Acta odontol. latinoam ; 34(3): 282-288, 2021. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1383415

RESUMO

ABSTRACT This study compared the shaping ability of single-file reciprocating (WaveOne Gold) and multifile rotary (Mtwo) systems on mandibular oval-shaped canine root canals, using microcomputed tomography (micro-CT). Thirty mandibular canines were scanned by micro-CT and assigned to one of two groups (n=15) according to the system used for root canal preparation: WaveOne Gold or Mtwo. After preparation, the teeth were rescanned, and the percentage of untouched canal area, apical transportation and centering ability were analyzed. The data was evaluated using Kruskal and Mann- Whitney tests (p<0.05). No difference was found in percentage of unprepared canal area between groups in the entire root canal or the apical third, or in centering ability (p>0.05). WaveOne gold had less canal transportation than MTwo at the 5 mm section (p<0.05). WOG and Mtwo systems presented similar shaping ability and centering ability in oval-shaped canals. However, WOG presented less transportation than Mtwo at 5 mm from the apex.


RESUMO Este estudo comparou a capacidade de modelagem dos sistemas reciprocante de lima única (WaveOne Gold) e rotatórios com múltiplas limas (Mtwo) em caninos ovais inferiores, usando microtomografia computadorizada (micro-CT). Trinta caninos inferiores foram escaneados por micro-CT e divididos em dois grupos (n = 15) de acordo com o sistema usado durante o preparo do canal radicular: WaveOne Gold (WOG) e Mtwo. Os dentes foram reeescaneados e a porcentagem de área do canal não preparada, transporte apical e capacidade de centralização foram analisados. Os dados foram avaliados pelos testes de Kruskal Wallis e Mann-Whitney (p<0,05). Nenhuma diferença foi encontrada na porcentagem de área não preparada entre os grupos em todo o canal radicular e no terço apical e na capacidade de centralização (p>0,05). O sistema WOG promoveu menor transporte do canal do que o sistema Mtwo na região de 5mm aquém do ápice (p<0,05). Os sistemas WOG e Mtwo apresentaram capacidade de modelagem e capacidade de centralização semelhantes em canais ovais. No entanto, WOG promoveu menor transporte do que Mtwo a 5 mm do ápice.

17.
Braz. dent. sci ; 24(1): 1-8, 2021. tab, ilus
Artigo em Inglês | BBO, LILACS | ID: biblio-1145442

RESUMO

Objetivo: Estudos demostraram que a zircônia monolítica um dos materiais restauradores desenvolvidos recentemente, resolveu vários problemas de restauração de zircônia. Portanto, a precisão marginal e o ajuste interno são necessários para o sucesso clinico e para a qualidade da restauração, e o espaço do cimento pode influenciar o ajuste marginal. Assim, o presente estudo teve como objetivo investigar os efeitos da espessura do cimento e o tipo de restauração na discrepância marginal. Material e métodos: foram usadas para fabricação de coroa total. Dois tipos de materiais incluindo Zirconia monolítica (Zolid) e Sintron foram usadas para produzir a coroa total. As amostras de cada grupo foram digitalizadas em laboratório dentário por um scanner 3D, projetadas e acessadas usando CAD-CAM. As amostras foram divididas em quatro grupos de cinco com espaço de 30 e 50 mícrons de cimento. Para avaliar a discrepância marginal, as coroas foram colocadas em seus respectivos dentes sem o uso de qualquer intermediário e examinados em micro-CT. Os dados foram avaliados pelo software SPSS. Resultados: Descobriu-se que a discrepância marginal do Sintron é maior que a discrepância da zircônia monolítica. Na verdade, a zircônia monolítica com espaço de 50 µm de cimento exibiu uma menor discrepância marginal, e o espaço de cimento do Sintron não influenciou significantemente na discrepância marginal. Conclusão: Concluiu-se que os tipos de material e o espaço do cimento influencia na discrepância marginal da restauração construída pelo fluxo digital (AU)


Objective: Studies demonstrated that as one of then ewly developed restorative materials, monolithic zirconia resolved several issues of zirconia restoration. Therefore, marginal accuracy and internal fit are necessary for clinical success and quality of restorations, and cement space may influence the marginal fit. Thus, the present research aimed to investigate the effects of the cement thickness and kind of restoration on the marginal discrepancy. Material and methods: In this study, 20 maxillary left first molars, prepared by DRSK Co., were used to fabricate a full crown. Two types of material included monolithic zirconia (Zolid) and Sintron were used to make a full crown. Samples from each group were scanned by dental laboratory 3D scanner and designed and processed using CAD-CAM. The samples were divided into four groups of five with 30-and 50- µm cement spaces. In order to assess the vertical marginal discrepancy, the crowns were fittedon their respective teeth without using any mediator and examined by a micro-CT scanner. Data were analyzed by SPSS software. Results: It has been found that marginal discrepancy in Sintron is higher than the discrepancy of monolithic zirconia. In fact, monolithic zirconia with 50-micron cement space exhibited the least marginal discrepancy and the cement space in Sintron did not significantly influence the marginal discrepancy. Conclusion: It has been concluded that the material kinds and cement space influence the restoration marginal discrepancy constructed by digital workflow (AU)


Assuntos
Adaptação Marginal Dentária , Cimentos Dentários , Microtomografia por Raio-X
18.
Dent. press endod ; 10(3): 49-55, Sept-Dec.2020. Tab, Ilus
Artigo em Inglês | LILACS | ID: biblio-1344785

RESUMO

Objetivo: O presente estudo usou micro-CT para avaliar a quantidade de material obturador remanescente em canais radiculares curvos que tinham sido obturados com cimento Endosequence BC/Cpoint ou com cimento AH/ guta-percha, depois do retratamento utilizando instrumentos rotatórios ou reciprocantes. Métodos: Sessenta canais mesiovestibulares de molares superiores foram instrumentados até MTwo #35.04. As amostras foram randomicamente alocadas em quatro grupos (n=15): os canais do G1 e G2 foram obturados com AH/guta-percha, e os canais do G3 e G4 foram obturados com BC/Cpoint. O material obturador foi removido usando instrumentos rotatórios ou reciprocantes ­ G1 e G3: R25 Reciproc + reinstrumentação com R40; e G2 e G4: Sistema ProTaper Universal Retratamento + reinstrumentação com MTwo 40.06. Micro-CTs foram usadas para medir a quantidade de material obturador remanescente (mm3 ) para o canal inteiro e para cada terço, em dois momentos: 1) após a remoção do material obturador; e 2) após a reinstrumentação. Resultados: Após a remoção do material obturador, BC/CPoint permaneceu mais dentro do canal do que AH/guta-percha quando o canal inteiro (29,92% x 19,25%, p=0,0290) e o terço apical foram analisados. Após a reinstrumentação, BC/CPoint permaneceu mais do que AH/guta-percha somente no terço apical. Protocolos de tratamento com instrumentos rotatórios ou reciprocantes removeram material obturador sem diferença para AH/guta-percha (G1 e G2: p> 0,05) e BC/CPoint (G3 e G4: p> 0,05). Conclusões: BC/Cpoint é mais difícil de ser removido de canais radiculares curvos do que AH/guta-percha. Instrumentos rotatórios e reciprocantes têm habilidade similar na remoção de material obturador (AU).


Objective: This study used micro-CT to evaluate the amount of remaining filling material in curved root canals obturated with Endosequence BC Sealer/Cpoint or AH/gutta-percha after a rotary or reciprocating retreatment. Methods: Sixty mesiobuccal canals of maxillary molars were instrumented up to MTwo #35.04. Samples were randomly assigned to four groups (n=15): canals from G1 and G2 were filled with AH/gutta-percha, and canals from G3 and G4 were filled with BC/Cpoint. Filling material was removed using rotary or reciprocating instruments: G1 and G3: R25 Reciproc + re-shaping with R40; and G2 and G4: ProTaper Universal Retreatment system + re-shaping with MTwo 40.06. Micro-CT was used to measure the remaining amount of filling material (mm3 ), for the whole canal, and for each third, in two moments: 1) after filling removal and 2) after canal re-shaping. Results: After filling removal, BC/CPoint remained more into the canal than AH/Gutta-percha when the whole canal (29.92% x 19.25%, p = 0.0290) and the apical third were analyzed. After re-shaping, BC/CPoint remained more than AH/Gutta-percha only in the apical third. Rotary or reciprocating retreatment protocols removed filling material without difference for AH/gutta-percha (G1 and G2: p > 0.05) and BC/CPoint (G3 and G4: p > 0.05). Conclusion: BC/Cpoint is more difficult to be removed from curved root canals than AH/gutta-percha. Reciprocating and rotary instruments have similar ability to remove filling material (AU).


Assuntos
Materiais Restauradores do Canal Radicular , Biofilmes , Instrumentos Odontológicos , Microtomografia por Raio-X , Remoção , Retratamento , Guta-Percha , Dente Molar
19.
Rev. cuba. estomatol ; 57(2): e2901, abr.-jun. 2020. tab, graf
Artigo em Português | LILACS, CUMED | ID: biblio-1126500

RESUMO

RESUMO Introdução: Os estudos científicos acerca das propriedades físicas e mecânicas apresentadas pelas resinas compostas são cada vez mais necessários diante da grande variedade de produtos disponíveis no mercado atual, resultante do aumento de sua demanda dentro da odontologia que preza por preparos minimamente invasivos com a devolução das características estéticas e funcionais do elemento dentário. Objetivo: Avaliar e comparar a microdureza e porosidade das resinas compostas fotopolimerizavéis Filtek Z350 XT 3M e Zirconfill Technew. Métodos: Foram confeccionados 10 corpos de prova por amostra (n= 10) submetidos a teste microdureza Vickers e porosidade por microtomografia computadorizada. Resultados: Com relação à presença de porosidades, dada em porcentagem, o grupo da Filtek apresentou os menores valores médios. Quando comparado estatisticamente, os grupos apresentaram diferença estatística (p= 0,019), com uma magnitude de efeito alta. Com relação aos valores de microdureza, o grupo da Filtek apresentou os maiores valores médios. Quando comparados estatisticamente, os grupos não apresentaram diferença estatística (p > 0,05). Conclusões: A porosidade foi significativamente diferente entre os grupos estudados, sendo o grupo Filtek Z350XT de menor percentual. No entanto, os grupos não apresentaram diferença estatística para microdureza, apesar do grupo Filtek Z350XT ter apresentado maior valor médio(AU)


RESUMEN Introducción: Los estudios científicos sobre las propiedades físicas y mecánicas presentadas por las resinas compuestas son cada vez más necesarios ante la gran variedad de productos disponibles en el mercado actual, resultante del aumento de su demanda dentro de la odontología que aprecia por preparaciones mínimamente invasivas con la devolución de las características estéticas y funcionales del elemento dental. Objetivo: Evaluar y comparar la microdureza y porosidad de las resinas compuestas fotopolimerizables Filtek Z350 XT 3M y Zirconfill Technew. Métodos: Se han confeccionado 10 cuerpos de prueba por muestra (n= 10) sometidos a prueba de microdureza Vickers y porosidad por microtomografía computarizada. Resultados: Con respecto a la presencia de porosidades, dada en porcentaje, el grupo de Filtek presentó los menores valores medios. Cuando se comparó estadísticamente, los grupos presentaron una diferencia estadística (p= 0,019), con una magnitud de efecto alto. Con respecto a los valores de microdureza, el grupo de Filtek presentó los mayores valores medios. Cuando se comparó estadísticamente, los grupos no presentaron una diferencia estadística (p> 0,05). Conclusiones: La porosidad fue significativamente diferente entre los grupos estudiados, siendo el grupo Filtek Z350XT de menor porcentaje. Sin embargo, los grupos no presentaron diferencia estadística para microdureza, a pesar de que el grupo Filtek Z350XT presentó un valor medio más alto(AU)


ABSTRACT Introduction: Scientific studies about the physical and mechanical properties of composite resins are increasingly needed in view of the wide variety of products available in the market today, resulting from the increase in their demand for dental care purposes, with a preference for minimally invasive preparations aimed at restoring the esthetic and functional characteristics of the treated element. Objective: Evaluate and compare the microhardness and porosity of the photopolymerizable composite resins Filtek Z350 XT and Zirconfill Technew. Methods: Ten test bodies were developed per sample (n= 10) and subjected to Vickers microhardness and porosity testing by computerized microtomography. Results: With respect to the presence of porosity, expressed in percentages, the Filtek group had the lowest mean values. When compared statistically, the two groups showed a statistical difference (p= 0.019) with a high effect magnitude. Regarding microhardness, the Filtek group had the highest mean values. Statistical comparison did not find any difference between the groups (p> 0.05). Conclusions: Porosity was significantly different in the groups studied, the Filtek Z350XT group exhibiting the lowest percentage. However, the groups did not show any statistical difference concerning microhardness, despite the fact that the Filtek Z350XT group had a higher mean value(AU)


Assuntos
Humanos , Assistência Odontológica/efeitos adversos , Resinas Compostas/efeitos adversos , Microtomografia por Raio-X/métodos , Testes de Dureza/métodos
20.
Acta odontol. latinoam ; 33(1): 33-37, June 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1130730

RESUMO

ABSTRACT This study evaluated the internal morphology of lower incisors using computerized microtomography (microCT) images. Eightynine lower incisors were scanned by microCT and reconstructed with NRecon software. 2D parameters (perimeter, root length, circularity and canal diameter) and 3D parameters (volume, surface area and structure model index) were evaluated with CTAn and CTVol software. The results are presented descriptively. It was found that 89.9% of the canals had a single main root canal (type I), followed by type II (6.7%) and III (3.4%), while 5.6% of the specimens presented lateral canals and 1.1% had an apical delta. Mean volume and surface area were 31.80mm³ and 90.58mm², respectively. The most prevalent shape of the root canal at CEJ level was circular (41.6%) and 1mm from the apex, 73% of the samples were classified as oval. Lower incisors with internal anatomical variations may offer a high degree of technical complexity and may result in treatment failure.


RESUMO Este estudo avaliou a morfologia interna dos dentes incisivos inferiores utilizando imagens de microtomografia computado rizada (microTC). 89 incisivos inferiores foram escaneados por microCT e reconstruídos com o programa NRecon. Parâmetros 2D perímetro, comprimento da raiz, circularidade e diâmetro do canal e parâmetros 3D volume, área superficial e índice de modelo de estrutura foram avaliados com os softwares CTAn e CTVol. Os resultados foram apresentados de forma descritiva. 89,9% dos canais apresentaram um único canal radicular principal (tipo I), seguido pelo tipo II (6,7%) e III (3,4%). 5,6% dos espécimes apresentavam canais laterais e 1,1% delta apical. O volume médio e a área de superfície foram 31,80mm³ e 90,58mm², respectivamente. A forma mais prevalente do canal radicular no nível da CEJ foi circular (41,6%) e a 1 mm do ápice, 73% das amostras foram classificadas como ovais. Incisivos inferiores com variações anatômicas internas podem oferecer um alto grau de complexidade técnica e resultar em falha do tratamento.


Assuntos
Humanos , Cavidade Pulpar/diagnóstico por imagem , Microtomografia por Raio-X/métodos , Incisivo/anatomia & histologia , Mandíbula , Processamento de Imagem Assistida por Computador , Incisivo/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA