Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Artigo em Chinês | WPRIM | ID: wpr-707099

RESUMO

Objective To optimize the process conditions of one-step pelletization of Rouganbao Granules. Methods The factors influencing the pelletization of Rouganbao Granules were investigated by L9(34)orthogonal test, with the indexes of forming rate and fluidity. Results The spraying speed had the greatest effect on one-step pelletization, followed by atomization pressure and material temperature, and wind temperature had the smallest effect. At last, the best process parameters were relative density 1.15 (60 ℃), spray speed 55 mL/min, atomization pressure 0.25 MPa, wind temperature 75 ℃, material temperature 55 ℃, and critical relative humidity was 63%. Conclusion One-step pelletization technology can improve the preparation level and product quality, which can be used for the industrial production of Rouganbao Granules.

2.
Artigo em Chinês | WPRIM | ID: wpr-304892

RESUMO

To optimize the one-step pelletization technology of Fuke IV (FKIV) granules by response surface methodology. With the qualified rate of granules as evaluation indexes, 6 factors affecting one-step pelletization technology were investigated, significant levels of each factor were evaluated and the primal influential factors were determined by Plackett-Burman experimental design. According to the Plackett-Burman experimental design, the qualified rates of granules, moisture capacity and angle of repose as the evaluation indexes, Box-Behnken design with three levels and three factors was established for quadratic regression fitting of the models. Then the experimental results were optimized by Response Optimizer. The best process conditions were determined as follows: the extract relative density of 1.20, inlet air temperature of 88 ℃, and atomization pressure of 0.28 MPa. FKIV granules were prepared by the optimized experimental scheme. The determined qualified rate, moisture capacity and angle of response were 93.65%, 3.76% and 23.19° respectively for the granules, basically similar to the predicted values, indicating that the optimal process conditions were in line with the manufacturing requirements.

3.
Artigo em Chinês | WPRIM | ID: wpr-855036

RESUMO

Objective: To optimize the one-step pelletization technology of Tianshu Capsule by Minitab software. Methods: Using the qualified rates of particles as the evaluation indexes, three significant impact factors (fluid extract-dextrin ratio, infusion frequency, and atomization pressure) of one-step pelletization technology were selected and the levels of non-significant factors were identified by the Plackett-Burman experimental design. According to single factor experiments, choosing the qualified rates of particles, moisture, and angle of repose as the evaluation indexes, three levels of the three factors were selected by Box-Behnken of central composite design to establish the multiple linear regression and binomial fitting, and the experimental data were optimized by the response optimizer. Results: The best conditions were as follows: fluid extract-dextrin of 1.57:1 put in fluid-bed and heated by fan; the temperature of the bottom material in the fluidized state was increased to 50°C, fluid extract of 2% HPMC was sprayed with frequency of 32 Hz, the frequency of fan was 30 Hz, inlet air temperature was 60°C, atomization pressure was 0.21 MPa, and feed temperature was 50°C. Conclusion: Under the Minitab optimized scheme, the average experimental results are similar to the predicted values, and Minitab software could be used in the optimization of one-step pelletization for Chinese materia medica.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA