Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 998
Filtrar
1.
J. oral res. (Impresa) ; 13(1): 160-169, mayo 29, 2024. ilus
Artigo em Inglês | LILACS | ID: biblio-1563437

RESUMO

Objective: To evaluate the influence of opacity and the layering technique on the fluorescence of different composite resins. Materials and Methods: Two opacities (enamel and dentin) and the layering technique (enamel + dentin) of the composite resins: Filtek® Z350 and Palfique LX5 were evaluated in vitro. Composite resin discs were fabricated using a preformed matrix of 10 mm diameter and 0.5 mm thick for the single opacity groups and 10 mm thick for the layering technique groups, using 2 layers of 0.5 mm thickness of each opacity (n = 5). Specimens were analyzed using the Raman spectroscopy method. Data were analyzed using the Kruskall-wallis and Mann-Whitney U tests. Results: When evaluating the intensity of fluorescence, no statistically significant difference was found when comparing the layering technique and enamel opacity (p2> 0.05) and an increase in the dentin opacity value for both brands of composite resin. Regarding wavelength, no statistically significant difference was found when comparing the layering technique with enamel opacity and dentin opacity for both Filtek® Z350 and Palfique LX5® composite resins (p2 > 0.05). Conclusions: The fluorescence intensity of the layering technique is similar to enamel opacity for both composite resins. Likewise, the wavelength of the layering technique is similar to the enamel opacity and dentin opacity for both brands.


Objetive: Evaluar la influencia de la opacidad y de la técnica de estratificación en la fluorescencia de diferentes resinas compuestas. Materiales y Métodos: Se evaluó in vitro 2 opacidades (Esmalte y Dentina) y la técnica de estratificación (Esmalte + Dentina) de las resinas compuestas: Filtek® Z350 y Palfique LX5. Se fabricaron discos de resina compuesta, utilizando una matriz preformada de 10 mm de diámetro y 0,5 mm de grosor para los grupos de opacidad única y 10 mm de grosor para los grupos de técnica estratificada, utilizando 2 capas de 0,5 mm de cada opacidad (n = 5). Los especímenes se analizaron mediante el método de Espectroscopía Raman. Los datos se analizaron utilizando la prueba de Kruskall-wallis y Prueba U de Mann Whitney. Resultado: Al evaluar la intensidad de fluorescencia no se encontró diferencia estadísticamente significativa entre los pares: Técnica estratificada versus Opacidad Esmalte para ambas marcas de resina compuesta Filtek® Z350 y para Palfique LX5® (p2 > 0,05). Para longitud de onda no se encontró diferencia estadísticamente significativa entre los pares: Técnica estratificada versus Opacidad Esmalte y Técnica estratificada VS Opacidad Dentina para ambas resinas compuesta Filtek® Z350 y Palfique LX5® (p2> 0,05). Conclusión: La intensidad de fluorescencia de la técnica estratificada es similar a la opacidad Esmalte para ambas resinas compuestas. De igual manera la longitud de onda de la técnica estratificada es similar a la opacidad Esmalte y opacidad Dentina para ambas marcas.


Assuntos
Humanos , Resinas Compostas/química , Nanotecnologia/métodos , Análise Espectral , Técnicas In Vitro
2.
Int. j. morphol ; 42(2)abr. 2024.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1558122

RESUMO

SUMMARY: Over time, Goldner's trichrome staining has been essential in paraffin soft tissue research. However, its classic application involves prior decalcification, generating disadvantages in the integrity of the samples and the interpretation of results. This study seeks to overcome the limitations associated with decalcification when applying Goldner's trichrome stain with plastic resins. It focuses on detailed visualization of non-decalcified bone and dental samples in animal models. Samples of jaw and tooth from a dog (Canis familiaris) were used, as well as tibia from a rabbit (Oryctolagus cuniculus) with a titanium dental implant and bone graft substitute. Adjustments were made to the original protocol, including a surface treatment prior to staining. Plastination and inclusion in specific plastic resins were part of the process. The microplastinated and stained samples showed optimal quality for optical microscopy. Those from dogs allowed detailed observation of the tooth-periodontal tissue relationship, while those from rabbits revealed a clear differentiation between mineralized and osteoid bone tissue. The staining made it easy to examine the precise interface between soft tissues, bone graft, and implant. The successful adaptation of Goldner's trichrome stain to specimens in plastic resins represents a significant advance in histological investigation of hard tissues. This methodology stands out as an effective tool to evaluate implants and biomaterials in animal models, providing detailed visualization without compromising the integrity of the samples. The combination of histochemistry and plastic resins offers a valuable alternative for microanatomical studies, opening new possibilities in hard tissue research and evaluation of bone structures.


A lo largo del tiempo, la tinción tricrómica de Goldner ha sido esencial en la investigación de tejidos blandos en parafina. Sin embargo, su aplicación clásica conlleva la descalcificación previa, generando desventajas en la integridad de las muestras y la interpretación de resultados. Este estudio busca superar las limitaciones asociadas con la descalcificación al aplicar la tinción tricrómica de Goldner con resinas plásticas. Se enfoca en visualizar detalladamente muestras óseas y dentales no descalcificadas en modelos animales. Se emplearon muestras de mandíbula y diente de perro (Canis familiaris), así como tibia de conejo (Oryctolagus cuniculus) con implante dental de titanio y substituto de injerto óseo. Se realizaron ajustes al protocolo original, incluyendo un tratamiento superficial previo a la tinción. La plastinación y la inclusión en resinas plásticas específicas fueron parte del proceso. Las muestras microplastinadas y teñidas mostraron una calidad óptima para microscopía óptica. Las de perro permitieron la observación detallada de la relación diente-tejido periodontal, mientras que las de conejo revelaron una clara diferenciación entre tejido óseo mineralizado y osteoide. La tinción facilitó examinar la interface precisa entre tejidos blandos, injerto óseo e implante. La adaptación exitosa de la tinción tricrómica de Goldner a muestras en resinas plásticas representa un avance significativo en la investigación histológica de tejidos duros. Esta metodología destaca como una herramienta eficaz para evaluar implantes y biomateriales en modelos animales, brindando una visualización detallada sin comprometer la integridad de las muestras. La combinación de histoquímica y resinas plásticas ofrece una alternativa valiosa para estudios microanatómicos, abriendo nuevas posibilidades en la investigación de tejidos duros y evaluación de estructuras óseas.

3.
Rev. estomatol. Hered ; 34(1): 7-16, ene.-mar. 2024. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1565539

RESUMO

RESUMEN Objetivo : Comparar la microdureza de la resina compuesta con técnica índex convencional y modificada con cubeta impresa en dos fotopolimerizaciones. Materiales y métodos : Se contó con seis grupos de estudio de acuerdo a la técnica y a la cantidad de fotopolimerizaciones: técnica directa con una fotopolimerización (D1F), directa con dos fotopolimerizaciones (D2F), índex convencional con una fotopolimerización (IC1F), índex convencional con dos fotopolimerizaciones (IC2F), índex modificada con una fotopolimerización (IM1F), índex modificada con dos fotopolimerizaciones (IM2F). Se utilizaron quince muestras por cada grupo. Las muestras tuvieron dimensiones de 2 mm de altura por 5 mm de diámetro. Se realizó la fotopolimerización siguiendo las indicaciones del grupo al que corresponde, para luego someter a la prueba de dureza de Vickers a tres indentaciones por cada cara con carga de 200 g por 15 segundos. Se realizaron dos registros de microdureza, una superficial y otra a 2 mm. Se recolectaron los datos en el instrumento confeccionado y fueron procesados mediante SPSS v. 26. Resultados : Existe una diferencia significativa entre los grupos de microdureza superficial de primera fotopolimerización (p < 0,001); y también existe diferencia significativa entre los grupos de microdureza a 2 mm de primera fotopolimerización (p < 0,001). Asimismo, no existen diferencias significativas entre los grupos de microdureza superficial de segunda fotopolimerización (p = 0,519) ni en los grupos de microdureza a 2 mm de segunda fotopolimerización (p = 0,279). Conclusiones: No existen diferencias significativas en la microdureza superficial y a 2 mm de profundidad con técnica índex convencional y modificada en cubeta impresa en dos fotopolimerizaciones.


ABSTRACT Objective : To compare the microhardness of composite resin with conventional and modified index techniques with a printed tray in two light cures. Materials and methods : There were six study groups according to the technique and the number of photopolymerizations: direct technique with one photopolymerization (D1F), direct with two photopolymerizations (D2F), conventional index with one photopolymerization (IC1F), conventional index with two photopolymerizations (IC2F), modified index with one photopolymerization (IM1F), modified index with two photopolymerizations (IM2F). Fifteen samples were used for each group. The samples had dimensions of 2 mm in height by 5 mm in diameter. The photopolymerization was performed following the indications of the group to which it corresponds and then subjected to the Vickers hardness test with three indentations on each side with a load of 200 g for 15 seconds. Two microhardness recordings were made, one superficial and the other at 2 mm. Results : There is a significant difference between the first light-curing surface microhardness groups (p < 0.001), and there is also a significant difference between the first light-curing 2 mm microhardness groups (p < 0.001). Likewise, there are no significant differences between the second light-curing surface microhardness groups (p = 0.519) or the second light-curing 2 mm microhardness groups (p = 0.279). Conclusions : There are no significant differences in surface microhardness and microhardness at 2 mm depth with conventional and modified index techniques in printed trays in two photopolymerizations.


RESUMO Objetivo : Comparar a microdureza da resina composta com a técnica de índice convencional e modificada com moldeira impressa em duas fotopolimerizações. Materiais e métodos : Foram constituídos seis grupos de estudo de acordo com a técnica e o número de ciclos de fotopolimerização: técnica direta com um ciclo de fotopolimerização (D1F), direta com dois ciclos de fotopolimerização (D2F), índice convencional com um ciclo de fotopolimerização (IC1F), índice convencional com dois ciclos de fotopolimerização (IC2F), índice modificado com um ciclo de fotopolimerização (IM1F), índice modificado com dois ciclos de fotopolimerização (IM2F). Foram utilizadas quinze amostras para cada grupo. Os espécimes tinham 2 mm de altura por 5 mm de diâmetro. A fotopolimerização foi efetuada de acordo com as indicações do grupo a que corresponde, e depois submetida ao teste de dureza Vickers com três indentações de cada lado com uma carga de 200 g durante 15 segundos. Foram efetuados dois registos de microdureza, um superficial e outro a 2 mm. Os dados foram recolhidos no instrumento e processados utilizando o SPSS v. 26. Resultados : Há uma diferença significativa entre os primeiros grupos de microdureza superficial fotopolimerizável (p < 0,001); e há também uma diferença significativa entre os primeiros grupos de microdureza de 2 mm fotopolimerizável (p < 0,001). Da mesma forma, não há diferença significativa entre os grupos de microdureza da superfície do segundo fotopolimerizador (p = 0,519) e nos grupos de microdureza de 2 mm do segundo fotopolimerizador (p = 0,279). Conclusões : Não existem diferenças significativas na microdureza da superfície e na microdureza a 2 mm de profundidade com a técnica de índice convencional e modificada em duas fotopolimerizações.

4.
Braz. j. oral sci ; 23: e241938, 2024. ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-1532506

RESUMO

Aim: To evaluate changes in the surface roughness and morphology of a nanofilled composite following toothbrushing with a whitening (WT) or regular toothpaste (RT), alone or combined with 35% hydrogen peroxide bleaching (HP). Methods: Seventy disc-shaped nanofilled composite (Filtek Z350XT) specimens were randomly divided into groups (n=10): WT, RT, TB (without toothpaste ­ control) or the combinations WT/ HP, RT/HP, TB/HP and HP. All groups underwent toothbrushing simulation (60,000 cycles) and bleaching treatment (4 sessions). Mean surface roughness (Ra, µm) was measured before (T0) and after treatments (TB). Surface morphology was assessed by scanning electron microscopy (SEM) at TB. Mean Ra was analyzed using general mixed models and multiple comparisons by the Tukey-Kramer test (α=5%). Results: HP caused no surface roughness changes on the nanofilled composite after treatment (p>0.05). RT toothbrushing, combined or not with HP, increased the surface roughness (p<0.05). WT and WT/ HP protocols had no effect on the surface roughness of the composite (p>0.05). The nanofilled composite submitted to RT toothbrushing combined with HP (RT/HP) presented substantial surface alterations under SEM, showing deep depressions and round-shaped defects. Toothbrushing with RT combined with the bleaching agent increased exposure of the inorganic fillers. Conclusion: WT toothbrushing, regardless of HP combination, or the single HP protocol had no effect on the surface roughness of the nanofilled composite. However, RT combined with HP negatively affected surface roughness and presented the most noticeable surface changes among groups


Assuntos
Clareamento Dental , Cremes Dentais , Microscopia Eletrônica de Varredura , Resinas Compostas , Peróxido de Hidrogênio
5.
Pesqui. bras. odontopediatria clín. integr ; 24: e220192, 2024. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-1550593

RESUMO

ABSTRACT Objective: To investigate the effects of two different dentifrice fluoride concentrations on the color stability of the composite. Material and Methods: Twenty-seven specimens (2×4×5 mm) each of microfilled (Gradia, GC, Japan) and nanohybrid (Grandio, VOCO, Germany) composites were prepared. The specimens were randomly divided into six groups (control, Fluoflor caries protection toothpaste with 1450ppm Fluoride (EXW, France), and Fluoflor kids toothpaste with 500ppm Fluoride (EXW, France) (n = 9). The specimens were immersed in a mixture of artificial saliva and toothpaste in a ratio of 1:3 and applied for 60 seconds every 12 hours for 42 days. The control samples were incubated in artificial saliva at 37°C. Primary and secondary color measurements were performed using color parameters (L∗a∗b) with a spectrophotoshade (MHT Optic Research AG, Niederhasli, Switzerland). Data were analyzed using a two-way analysis of variance at a significance level of 0.05. Results: According to the two-way ANOVA analysis, there was no significant difference in color change between the composites and no difference in the level of discoloration between different fluoride concentrations(p>0.05). Also, None of the dentifrices caused clinically significant color changes(∆E˂3.3). Conclusion: No clinically unacceptable color changes were observed in the microfilled and nanofilled composites with different concentrations of fluoride toothpaste.


Assuntos
Cremes Dentais/química , Cor , Resinas Compostas/química , Fluoretos/química , Técnicas In Vitro/métodos , Análise de Variância , Dentifrícios
6.
Pesqui. bras. odontopediatria clín. integr ; 24: e220113, 2024. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-1529140

RESUMO

Abstract Objective: To evaluate the effect of different pressures of an oral irrigation device (OID) and the irrigation solution type on the surface roughness of the giomer restorative material. Material and Methods: In this in vitro study, disk-shaped giomer samples were fabricated and assigned to 5 groups (n=23): Group 1, storage in distilled water (control); Group 2, OID #7 pressure/ water; Group 3, OID #10 pressure/ water; Group 4, OID #7 pressure/ 0.05% CHX; Group 5, OID #10 pressure/ 0.05% CHX. The samples' treatment simulated a one-year application of OID. Surface roughness (Ra) and topography of the giomer were evaluated using profilometry and scanning electron microscopy. The data were analyzed with Paired t-test, Tukey, and ANOVA tests (α=0.05). Results: The Ra of the samples increased significantly after treatment with OID (p<0.001). The roughness increase in groups with a pressure of 10 was higher than those with a pressure of 7 (p<0.001). The effect of pressure on surface changes was significant (p<0.001). However, the solution type and the cumulative effect of these two factors were insignificant (p=0.08 and p=0.43, respectively). Conclusion: Oral irrigation device with both solutions significantly increased the surface roughness and topographic changes of the giomer. The severity of these changes was related to the device's pressure.


Assuntos
Biguanidas , Água Destilada , Clorexidina/efeitos adversos , Resinas Compostas , Propriedades de Superfície , Técnicas In Vitro/métodos , Análise de Variância , Testes de Dureza/métodos
7.
Braz. j. oral sci ; 23: e240398, 2024. tab
Artigo em Inglês | LILACS, BBO | ID: biblio-1553456

RESUMO

Aim: This study aimed to assess the polymerization effectiveness of bulk-fill composite resins in longitudinal microhardness. Methods: Blocks of bulk-fill composite resin with thicknesses of 6 mm were analyzed with Vickers microhardness. The resin blocks were divided into two groups (n=6): resin AURA and OPUS. The microhardness test was performed before (base and top) and after (longitudinal microhardness) sectioning the blocks at distances of 2 mm, 4 mm, and 6 mm from the top of the block. The mean microhardness values were tabulated and subjected to ANOVA followed by Tukey's test (p<0.05). Results: The OPUS bulk-fill resin samples presented microhardness means of 55.9 kgf/mm2, 53.7 kgf/mm2, and 49.3 kgf/mm2, the AURA bulk-fill resin samples presented microhardness means of 57,02 kgf/mm2, 55,86 kgf/mm2 e 51,77 kgf/mm2 for the distances of 2 mm, 4 mm, and 6 mm, respectively. Tukey's statistical test showed a significant difference in microhardness values at different distances of 2 mm, 4 mm, and 6 mm (p<0.001) for each resin. Although there was a statistically significant difference within and between the groups assessed, all samples showed polymerization effectiveness when comparing the top and base of the block. Conclusion: Polymerization was effective in different thicknesses (2 mm, 4 mm, and 6 mm) in both resins studied. The microhardness ratio was adequate when comparing the base and top


Assuntos
Eficácia , Resinas Compostas , Polimerização , Dureza
8.
Braz. oral res. (Online) ; 38: e032, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1557352

RESUMO

Abstract This study assessed the reliability of a color measurement method using images obtained from a charge-coupled device (CCD) camera and a stereoscopic loupe. Disc-shaped specimens were created using the composite Filtek Z350 XT (shades DA1, DA2, DA3, and DA4) (n = 3). CIELAB color coordinates of the specimens were measured using the spectrophotometer SP60 over white and black backgrounds. Images of the same specimens were taken using a CCD camera attached to a stereoscopic loupe. The color of the image was measured (red-green-blue [RGB]) using an image processing software and converted to CIELAB coordinates. For each color coordinate, data from images were adjusted using linear regressions predicting those values from SP60. The whiteness index for dentistry (WID) and translucency parameter (TP00) of the specimens as well as the color differences (ΔE00) among pairwise shades were calculated. Data were analyzed via repeated-measures analysis of variance and Tukey's post hoc test (α = 0.05). Images obtained using the loupe tended to be darker and redder than the actual color. Data adjustment resulted in similar WID, ΔE00, and TP00 values to those observed for the spectrophotometer. Differences were observed only for the WID of shade DA3 and ΔE00 for comparing DA1 and DA3 over the black background. However, these differences were not clinically relevant. The use of adjusted data from images taken using a stereoscopic loupe is considered a feasible method for color measurement.

9.
Braz. oral res. (Online) ; 38: e030, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1557363

RESUMO

Abstract This study aimed to evaluate volumetric polymerization shrinkage, degree of conversion and Vickers hardness of four bulk-fill resin composites light-activated with their dedicated light curing units (LCUs). Four groups were evaluated, according to the type of composite and curing mode: Tetric EvoCeram Bulk-fill (TEBO) and Tetric EvoFlow Bulk-fill (TEBF) were light-activated with Bluephase Style 20i (20s, in high-mode), while Tetric Powerfill (TEPO) and Tetric Powerflow (TEPF) were light-activated with Bluephase PowerCure (3s). Volumetric polymerization shrinkage test (n = 6) was performed in standardized box-shaped class-I cavities of extracted third molars (4 x 4 x 4 mm). Teeth were scanned before and after resin composite application by micro-computed tomography, and acquired data were evaluated with Amira software. Degree of conversion (n = 5) was evaluated at the top and bottom surfaces of composite cylindric samples (4 mm diameter, 4 mm thickness) using an FT-IR spectrometer (spectra between 1,500 and 1,800 cm-1, 40 scans at a resolution of 4 cm-1). Three Vickers indentations (50 g / 15 s), spaced 500 μm apart, were performed on the top and bottom composite surfaces and averaged. One-way ANOVA was used for data evaluation. TEPF showed the lowest volumetric polymerization shrinkage (p < 0.05), while the other composites were not significantly different within each other (p > 0.05). All materials presented a significant decrease in degree of conversion and Vickers hardness when compared top to bottom surfaces (p < 0.05). Bottom to top surface ratios for degree of conversion ranged from 0.8 (TEBO and TEPO) to 0.9 (TEBF and TEPF), and from 0.4 (TEPO) to 0.7 (TEBF and TEPF) for hardness. In conclusion, resinous materials present a decrease in hardness and degree of conversion from top to bottom even when a higher power is used, while the flowable material TEPF showed the lowest volumetric shrinkage values compared to the other materials.

10.
J. appl. oral sci ; 32: e20230397, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1558244

RESUMO

Abstract Specific products containing natural resources can contribute to the innovation of complete denture hygiene. Objective: To conduct an in vitro evaluation of experimental dentifrices containing essential oils of Bowdichia virgilioides Kunth (BvK), Copaifera officinalis (Co), Eucalyptus citriodora (Ec), Melaleuca alternifolia (Ma) and Pinus strobus (Ps) at 1%. Methodology: The variables evaluated were organoleptic and physicochemical characteristics, abrasiveness (mechanical brushing machine) simulating 2.5 years, and microbial load (Colony Forming Units - CFU/mL), metabolic activity (XTT assay) and cell viability (Live/Dead® BacLight™ kit) of the multispecies biofilm (Streptococcus mutans: Sm, Staphylococcus aureus: Sa, Candida albicans: Ca and Candida glabrata: Cg). Specimens of heat-polymerized acrylic resins (n=256) (n=96 specimens for abrasiveness, n=72 for microbial load count, n=72 for biofilm metabolic activity, n=16 for cell viability and total biofilm quantification) with formed biofilm were divided into eight groups for manual brushing (20 seconds) with a dental brush and distilled water (NC: negative control), Trihydral (PC: positive control), placebo (Pl), BvK, Co, Ec, Ma or Ps. After brushing, the specimens were washed with PBS and immersed in Letheen Broth medium, and the suspension was sown in solid specific medium. The organoleptic characteristics were presented by descriptive analysis. The values of density, pH, consistency and viscosity were presented in a table. The data were analyzed with the Wald test in a generalized linear model, followed by the Kruskal-Wallis test, Dunn's test (mass change) and the Bonferroni test (UFC and XTT). The Wald test in Generalized Estimating Equations and the Bonferroni test were used to analyze cell viability. Results: All dentifrices showed stable organoleptic characteristics and adequate physicochemical properties. CN, Ec, Ps, Pl and PC showed low abrasiveness. There was a significant difference between the groups (p<0.001) for microbial load, metabolic activity and biofilm viability. Conclusions: It was concluded that the BvK, Ec and Ps dentifrices are useful for cleaning complete dentures, as they have antimicrobial activity against biofilm. The dentifrices containing Bowdichia virgilioides Kunth showed medium abrasiveness and should be used with caution.

11.
J. appl. oral sci ; 32: e20230326, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1558246

RESUMO

Abstract Studies evaluating the roughness, wettability and microbial adhesion of 3D-printed resins for complete denture bases and teeth are scarce. Objective This study evaluated the surface roughness, wettability and adhesion of multispecies biofilms (Candida albicans, Staphylococcus aureus and Streptococcus mutans) on 3D-printed resins for complete denture bases and teeth compared to conventional resins (heat-polymerized acrylic resin; artificial pre-fabricated teeth). Methodology Circular specimens (n=39; 6.0 mm Ø × 2.0 mm) of each group were subjected to roughness (n=30), wettability (n=30) and biofilm adhesion (n=9) tests. Three roughness measurements were taken by laser confocal microscopy and a mean value was calculated. Wettability was evaluated by the contact angle of sessile drop method, considering the mean of the three evaluations per specimen. In parallel, microorganism adhesion to resin surfaces was evaluated using a multispecies biofilm model. Microbial load was evaluated by determining the number of Colony Forming Units (CFU/mL) and by scanning electron microscopy (SEM). Data were subjected to the Wald test in a generalized linear model with multiple comparisons and Bonferroni adjustment, as well as two-way ANOVA (α=5%). Results The roughness of the conventional base resin (0.01±0.04) was lower than that of the conventional tooth (0.14±0.04) (p=0.023) and 3D-printed base (0.18±0.08) (p<0.001). For wettability, conventional resin (84.20±5.57) showed a higher contact angle than the 3D-printed resin (60.58±6.18) (p<0.001). Higher microbial loads of S. mutans (p=0.023) and S. aureus (p=0.010) were observed on the surface of the conventional resin (S. mutans: 5.48±1.55; S. aureus: 7.01±0.57) compared to the 3D-printed resin (S. mutans: 4.11±1.96; S. aureus: 6.42±0.78). The adhesion of C. albicans was not affected by surface characteristics. The conventional base resin showed less roughness than the conventional dental resin and the printed base resin. Conclusion The 3D-printed resins for base and tooth showed less hydrophobicity and less adhesion of S. mutans and S. aureus than conventional resins.

12.
Braz. oral res. (Online) ; 38: e003, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1528147

RESUMO

Abstract Resin composites containing surface pre-reacted glass (S-PRG) have been introduced to reduce demineralization and improve remineralization of the tooth structure. However, water diffusion within the material is necessary for its action, which can impair its overall physicomechanical properties over time, including color stability. This study aimed to evaluate the color stability and related degree of conversion (DC) of four resin composites. Discs (6 x 4 mm, n = 5/group) of microhybrid (MH), nanofilled (NF), nanohybrid (NH), and S-PRG-based nanohybrid (S-PRG-NH) composites with two opacities (A2/A2E and A2O/A2D) were prepared. Color (CIELab and CIEDE2000) was evaluated with a spectrophotometer after aging in grape juice (2 x 10 min/10mL/7days). The DC was analyzed by using Fourier transform infrared spectroscopy before and after light-curing. Data were statistically analyzed by using two-way analysis of variance and post-hoc least significant difference tests (p<0.05). In the color stability analysis, the interaction between filler type and opacity was significant (CIELab, p = 0.0015; CIEDE2000, p = 0.0026). NH presented the highest color stability, which did not differ from that of MH. The greatest color alteration was observed for S-PRG-NH. S-PRG fillers also influenced DC (p < 0.05). The nanohybrid resin composite presented favorable overall performance, which is likely related to its more stable organic content. Notwithstanding the benefits of using S-PRG-based nanohybrid resins, mostly in aesthetic procedures, professionals should consider the susceptibility of such resins to color alteration, probably due to the water-based bioactive mechanism of action.

13.
J. appl. oral sci ; 32: e20230219, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1528890

RESUMO

Abstract Objective: In this study, a comparative evaluation of the physicochemical properties of Cention N and other direct restorative materials was performed. Three restorative materials—a resin-modified glass ionomer (Fuji II LC), an alkasite-based resinous material (Cention N), and a resin composite (Tetric N Ceram)—were characterized in terms of degree of conversion, Knoop hardness number (KHN) ratio, flexural strength, elastic modulus, water sorption, water solubility, microshear bond strength to dentin, immediate microleakage, and radiopacity. Methodology: The microshear bond strength to dentin and microleakage of Cention N were evaluated with and without the application of an adhesive system (Tetric N Bond Universal). A one-way ANOVA test was used to analyze the data in terms of degree of conversion, KHN ratio, water sorption, water solubility, microshear bond strength to dentin, and radiopacity. A two-way ANOVA test (carried out considering the material type and ethanol aging as factors) was used to analyze the data in terms of flexural strength and elastic modulus. The Kruskal-Wallis test was used to statistically analyze the data on microleakage. A significance level of α=0.05 was used for all tests. Results: Fuji II LC was found to have the highest degree of conversion, water sorption, and microleakage, as well as the lowest flexural strength. Cention N had the highest solubility; when used with an adhesive system, it achieved bond strength and microleakage similar to those of the Tetric N Ceram composite. Tetric N Ceram had the highest degree of conversion, KHN ratio, and radiopacity. Conclusion: The properties of Cention N validate its efficacy as an alternative direct restorative material when used in conjunction with an adhesive system.

14.
Braz. oral res. (Online) ; 38: e062, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1564197

RESUMO

Abstract This study investigated the impact of 'storage condition' and 'period of storage' on selected physico-mechanical properties and fracture reliability of a resin-based composite (RBC). Specimens, prepared from a nanofilled RBC (Filtek Z350 XT; 3M ESPE), underwent tests for degree of conversion (DC), flexural strength (σ), flexural modulus (E), and hardness. The specimens were initially grouped into dry storage at 37°C or wet storage in distilled water at 37°C. Subsequently, they were further divided into four subgroups based on the period of storage: 6, 24, 72, or 168 hours. Specimens tested immediately after preparation served as control. Data analysis employed two-way ANOVA and Weibull analysis (α = 5%). Compared to the control, an increase in DC was observed only after 72 hours of dry storage; σ showed higher values after both dry and wet storage, regardless of the storage period (except for the group wet-stored for 168 hours); E increased with dry storage for at least 24 hours or wet storage for 72 hours; and hardness increased after dry storage for at least 24 hours or wet storage for up to 72 hours. The Weibull modulus remained unchanged under any of the distinct storage conditions. Dry storage resulted in greater characteristic strength than the control, whereas wet storage contributed to higher strength values only at shorter periods (up to 24 hours). Overall, the inherent properties of RBCs with a similar composition to that tested in this study may change with varying storage conditions and periods.

15.
Pesqui. bras. odontopediatria clín. integr ; 24: e230179, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1564868

RESUMO

ABSTRACT Objective: To evaluate the pulpal temperature changes due to the polymerisation of resin and glass ionomer-based materials in dentine thicknesses in immature permanent teeth with open apices. Material and Methods: Forty extracted sound human third molar teeth with open apices were included. The width of the cavities prepared on the occlusal surface was 4×5 mm. The depth was 2 mm in the resin groups. 4 mm in the groups in which glass ionomer liner was applied before composite restoration. The coronal parts of the samples were then placed on an acrylic plate with three gaps for feeding-extraction needles and the thermocouple. The temperature changes were recorded. The data was analyzed by SPSS. Statistical significance was accepted as p<0.05. Results: The temperature increase in the group of 1 mm remaining dentin thickness revealed higher results than the values detected from the 2 mm group (1.01 °C) (p=0.00). The mean values (1.49 °C, 1mm) of temperature changes in only glass ionomer applied group were lower than the avarage values (2.210°C, 1mm) determined in the polymerization process of resin composites with light-emitting diode devices. Conclusion: In a remaining dentin thickness of 1 mm in teeth with open apices, using a glass ionomer liner might be a useful effort for protecting the pulp from the heat generated by polymerisation devices.

16.
Braz. dent. j ; 35: e24, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1550091

RESUMO

Abstract This research aimed to evaluate the effect of the radiopacity of a Bulk-Fill composite (X-TraFil, VOCO, Germany) and a Conventional composite (P60, 3M ESPE, USA) and assessment of the margin location in the enamel and dentin on the diagnosis of secondary caries. 76 intact premolars with MOD preparation were divided into two equal groups and filled with the conventional and bulk-fill composite. Four regions were considered to simulate carious lesions (two regions in enamel and two regions in dentin). In each group, half of the regions in the dentin and half in the enamel were randomly selected for secondary caries simulation and filled with a wax-plaster combination while the remaining regions stayed intact. Bitewing imaging was done using the PSP digital sensor. Five examiners reviewed the images, and lesions were recorded. Caries diagnosis indicators and paired-sample t-test were used for statistical analysis. The reproducibility and accuracy of the examiners' responses were evaluated using the kappa and agreement coefficient (α=0.05). The sensitivity, specificity, and accuracy of diagnosing secondary carious lesions in enamel were significantly better under conventional than bulk-fill composite. Similarly, the sensitivity and accuracy of diagnosing secondary caries in dentin were significantly higher under conventional composite than bulk-fill composite (p<0.05). No significant differences were found in the agreement and kappa coefficient between conventional and bulk-fill composites in the enamel and dentin (p>0.05). The diagnostic accuracy of carious lesions was higher under conventional composite than bulk-fill composite. However, the location of the secondary was ineffective in caries diagnosis.


Resumo Essa pesquisa teve como objetivo avaliar o efeito da radiopacidade de resina composta Bulk-Fill (X-TraFil, VOCO, Alemanha) e de resina composta convencional (P60, 3M ESPE, EUA) e a avaliação da localização da margem no esmalte e na dentina no diagnóstico de cárie secundária. 76 pré-molares intactos com preparo MOD foram divididos em dois grupos iguais e restaurados de acordo com o grupo experimental. Quatro regiões foram consideradas para simular lesões de cárie (duas regiões no esmalte e duas regiões na dentina). Em cada grupo, metade das regiões na dentina e metade no esmalte foram selecionadas aleatoriamente para a simulação de cárie secundária e preenchidas com uma combinação de cera e gesso, enquanto as regiões restantes permaneceram intactas. As imagens de bitewing foram feitas usando o sensor digital PSP. Cinco examinadores analisaram as imagens, e as lesões foram registradas. Os indicadores de diagnóstico de cárie e o teste t de amostra pareada foram usados para análise estatística. A reprodutibilidade e a precisão das respostas dos examinadores foram avaliadas usando o kappa e o coeficiente de concordância (α=0,05). A sensibilidade, a especificidade e a precisão do diagnóstico de lesões cariosas secundárias no esmalte foram significativamente melhores com a resina composta convencional do que com a resina composta bulk-fill. Da mesma forma, a sensibilidade e a precisão do diagnóstico de cáries secundárias na dentina foram significativamente maiores com a resina convencional do que com a resina bulk-fill (p<0,05). Não foram encontradas diferenças significativas na concordância e no coeficiente kappa entre as resinas convencionais e bulk-fill no esmalte e na dentina (p>0,05). A precisão do diagnóstico de lesões cariosas foi maior com a resina composta convencional do que com a resina composta bulk-fill. Entretanto, a localização do secundário foi ineficaz no diagnóstico de cárie.

17.
J. appl. oral sci ; 32: e20230278, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1550476

RESUMO

Abstract Objective The present in vitro study incorporated niobium oxyhydroxide fillers into an experimental high-viscosity bulk-fill resin composite to improve its mechanical performance and provide it a bioactive potential. Methodology Scanning electron microscopy synthesized and characterized 0.5% niobium oxyhydroxide fillers, demonstrating a homogeneous morphology that represented a reinforcement for the feature. Fillers were weighed, gradually added to the experimental resin composite, and homogenized for one minute, forming three groups: BF (experimental high-viscosity bulk-fill resin composite; control), BF0.5 (experimental high-viscosity bulk-fill resin composite modified with 0.5% niobium oxyhydroxide fillers), and BFC (commercial bulk-fill resin composite Beautifil Bulk U, Shofu; positive control). In total, 10 specimens/groups (8 × 2 × 2 mm) underwent flexural strength (FS) tests in a universal testing machine (Instron) (500N). Resin composites were also assessed for Knoop hardness (KH), depth of cure (DoC), degree of conversion (DC), elastic modulus (E), and degree of color change (ΔE). The bioactive potential of the developed resin composite was evaluated after immersing the specimens into a simulated body fluid in vitro solution and assessing them using a Fourier-transformed infrared spectroscope with an attenuated total reflectance accessory. One-way ANOVA, followed by the Tukey's test (p<0.05), determined FS, DC, KH, and ΔE. For DoC, ANOVA was performed, which demonstrated no significant difference between groups (p<0.05). Conclusions The high-viscosity bulk-fill resin composite with 0.5% niobium oxyhydroxide fillers showed promising outcomes as reinforcement agents and performed well for bioactive potential, although less predictable than the commercial resin composite with Giomer technology.

18.
Braz. j. oral sci ; 23: e241390, 2024. ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-1550150

RESUMO

Aim: To evaluate the surface roughness and color stability of bulk-fill resin composites after simulated toothbrushing with whitening dentifrices. The radioactive/relative dentin abrasion (RDA) and radioactive/relative enamel abrasion (REA) of dentifrices were also assessed. Methods: Specimens (n=10) of Tetric N Ceram Bulk Fill (TNCB), Filtek One Bulk Fill (FOB) resin composites, and Z100(Control) were prepared using a cylindrical Teflon matrix. Surface roughness (Ra, µm) was assessed by a roughness meter and the color evaluations (ΔEab , ΔE00 , WID ) were performed using a digital spectrophotometer based on the CIELAB system. Three measurements were performed per sample, before and after simulated toothbrushing with 3D Oral-B White Perfection (3DW) and Black is White (BW) dentifrices. The abrasivity (REA and RDA values) of the used dentifrices was also determined by the Hefferren abrasivity test. Results: The Ra values increased significantly in all resin composites after 3DW and BW toothbrushing. The acceptable threshold color varied among resin composites, and TNCB and Z100 presented the highest ΔEab and ΔE00 for BW dentifrice. The 3DW dentifrice was significantly more abrasive than BW dentifrice on enamel and dentin. Conclusions: simulated toothbrushing with tested whitening dentifrices increased the surface roughness at acceptable levels. The Tetric N Ceram Bulk-fill and Z100 composite showed the highest color alteration in BW. 3D White Perfection dentifrice was more abrasive on dentin and enamel than Black is White.


Assuntos
Cor , Resinas Compostas , Esmalte Dentário , Dentifrícios , Dentina , Clareadores
19.
Rev. Fac. Odontol. Porto Alegre ; 64(1): e130840, dez 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1526324

RESUMO

Objetivo: Avaliar o efeito de dois métodos de profilaxia sobre a rugosidade superficial de diferentes resinas compostas. Materiais e Métodos: Dez amostras (7 mm x 2 mm) foram confeccionadas para cada resina testada: MH - resina microhíbrida (viscosidade regular - Opallis); NH ­ resina nanohíbrida (viscosidade regular - Vittra APS); BF ­ resina bulk fill (alta viscosidade - Opus Bulk Fill); MHF ­ resina fluida microhíbrida (Opallis flow); e OS ­ resina nanohíbrida camaleão (viscosidade regular - Vittra Unique). Os valores iniciais de rugosidade (Rai) foram obtidos para cada amostra e então subdivididas em dois grupos (n = 5) seguindo o método de profilaxia: SB ­ jato de bicarbonato de sódio (125µm, 30 s, 10 mm de distância, 2 bar); e PP ­ profilaxia com pasta de pedra-pomes e escova rotatória (30 s, 3000 rpm e pressão de 150 g). Após, uma nova medida de Ra (Raf) foi obtida, e a diferença calculada (ΔRa). Os dados foram analisados pelo teste ANOVA três fatores e teste de Bonferroni, e a diferença de rugosidade (ΔRa) pelo teste Anova dois fatores e teste de Tukey (p<0,05). Resultados: MHF apresentou maior rugosidade após profilaxia com jato de bicarbonato, enquanto para NH a abrasão com pedra pomes foi mais deletéria. Para os demais grupos não houve diferença. Discussão: A alteração na rugosidade promovida pela profilaxia é material-dependente. Conclusão: A profilaxia profissional com jato de bicarbonato ou abrasão com pedra-pomes induziu alterações na rugosidade das resinas.


Aim: This study evaluated the effect of two prophylaxis methods over the surface roughness of different resin composites. Materials and Methods: Ten disc-shaped specimens (7 mm x 2 mm) were made for each composite tested: MH - microhybrid composite with regular viscosity (Opallis); NH ­ nanohybrid composite with regular viscosity (Vittra APS); BF ­ high-viscosity bulk fill composite (Opus Bulk Fill); MHF - microhybrid flowable composite (Opallis flow); and OS ­ nanohybrid one-shade composite with regular viscosity (Vittra Unique). Initial roughness (Ra) values were obtained from each sample, and then they were divided into two groups (n = 5) following the prophylaxis method: SB ­ prophylaxis with sodium bicarbonate powder (125µm grain) using an air-powder polishing device (30 s application distanced 10 mm with 2 bar); and PP ­ prophylaxis with pumice paste and rotatory brush (30 s, 3000 rpm and pressure of 150 g). After that, a new Ra measurement (Raf) was obtained, and the difference was calculated (ΔRa). Data were compared using Three-way ANOVA followed by Bonferroni teste and the Ra difference (ΔRa) was analyzed by Two-way ANOVA followed by the Tukey test (p<0.05). Results: MHF presented higher Ra values after receiving prophylaxis with SB, while for NH, the abrasion with pumice increased the Ra, and for the other groups, no differences were found. Discussion: Alteration promoted by prophylaxis is material dependent. Conclusion: Professional prophylaxis with a bicarbonate jet or abrasion with pumice-based paste can induce changes in the composites' roughness.

20.
Rev. Fac. Odontol. Porto Alegre ; 64(1): e130840, dez 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1526407

RESUMO

Objetivo: Avaliar o efeito de dois métodos de profilaxia sobre a rugosidade superficial de diferentes resinas compostas. Materiais e Métodos: Dez amostras (7 mm x 2 mm) foram confeccionadas para cada resina testada: MH - resina microhíbrida (viscosidade regular - Opallis); NH ­ resina nanohíbrida (viscosidade regular - Vittra APS); BF ­ resina bulk fill (alta viscosidade - Opus Bulk Fill); MHF ­ resina fluida microhíbrida (Opallis flow); e OS ­ resina nanohíbrida camaleão (viscosidade regular - Vittra Unique). Os valores iniciais de rugosidade (Rai) foram obtidos para cada amostra e então subdivididas em dois grupos (n = 5) seguindo o método de profilaxia: SB ­ jato de bicarbonato de sódio (125µm, 30 s, 10 mm de distância, 2 bar); e PP ­ profilaxia com pasta de pedra-pomes e escova rotatória (30 s, 3000 rpm e pressão de 150 g). Após, uma nova medida de Ra (Raf) foi obtida, e a diferença calculada (ΔRa). Os dados foram analisados pelo teste ANOVA três fatores e teste de Bonferroni, e a diferença de rugosidade (ΔRa) pelo teste Anova dois fatores e teste de Tukey (p<0,05). Resultados: MHF apresentou maior rugosidade após profilaxia com jato de bicarbonato, enquanto para NH a abrasão com pedra pomes foi mais deletéria. Para os demais grupos não houve diferença. Discussão: A alteração na rugosidade promovida pela profilaxia é material-dependente. Conclusão: A profilaxia profissional com jato de bicarbonato ou abrasão com pedra-pomes induziu alterações na rugosidade das resinas.


Aim: This study evaluated the effect of two prophylaxis methods over the surface roughness of different resin composites. Materials and Methods: Ten disc-shaped specimens (7 mm x 2 mm) were made for each composite tested: MH - microhybrid composite with regular viscosity (Opallis); NH ­ nanohybrid composite with regular viscosity (Vittra APS); BF ­ high-viscosity bulk fill composite (Opus Bulk Fill); MHF - microhybrid flowable composite (Opallis flow); and OS ­ nanohybrid one-shade composite with regular viscosity (Vittra Unique). Initial roughness (Ra) values were obtained from each sample, and then they were divided into two groups (n = 5) following the prophylaxis method: SB ­ prophylaxis with sodium bicarbonate powder (125µm grain) using an air-powder polishing device (30 s application distanced 10 mm with 2 bar); and PP ­ prophylaxis with pumice paste and rotatory brush (30 s, 3000 rpm and pressure of 150 g). After that, a new Ra measurement (Raf) was obtained, and the difference was calculated (ΔRa). Data were compared using Three-way ANOVA followed by Bonferroni teste and the Ra difference (ΔRa) was analyzed by Two-way ANOVA followed by the Tukey test (p<0.05). Results: MHF presented higher Ra values after receiving prophylaxis with SB, while for NH, the abrasion with pumice increased the Ra, and for the other groups, no differences were found. Discussion: Alteration promoted by prophylaxis is material dependent. Conclusion: Professional prophylaxis with a bicarbonate jet or abrasion with pumice-based paste can induce changes in the composites' roughness.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA