Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Korean Journal of Oral and Maxillofacial Radiology ; : 63-68, 2010.
Artigo em Coreano | WPRIM | ID: wpr-103561

RESUMO

PURPOSE: To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. MATERIALS AND METHODS: Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, rho (g/cm3), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. RESULTS: CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were rho=0.001H+1.07 with R2 value of 0.999 for Somatom Emotion, rho=0.002H+1.09 with R2 value of 0.991 for Alphard VEGA, rho=0.001H+1.43 with R2 value of 0.980 for i-CAT and rho=0.001H+1.30 with R2 value of 0.975 for Implagraphy. CONCLUSION: CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Modelos Lineares , Nylons , Plásticos , Poliestirenos , Tomografia Computadorizada por Raios X , Água
2.
Korean Journal of Oral and Maxillofacial Radiology ; : 81-87, 2009.
Artigo em Coreano | WPRIM | ID: wpr-180455

RESUMO

PURPOSE : To evaluate the anteroposterior length and buccal angle of the anterior loop, and the size and location of the mental foramen using cone beam computed tomography (CBCT). MATERIALS AND METHODS : 100 CBCT images from 87 adults (43 males and 44 females) ranging in age from 20 to 73 years (average 50 years) with edentulous ridge of the mandibular premolar region were obtained. Axial, sagittal, coronal images were reconstructed from Dental and Block Images of CBCT. The anteroposterior length, shape and buccal angle of the anterior loop, and the size and location of the mental foramen were calculated from reconstructed images of axial, sagittal and coronal CBCT. RESULTS : The anteroposterior length and buccal angle of the mental canal was 4.0+/-1.2 mm, 37.8+/-11.6 degrees respectively. The loop type with straight course was the most common shape of the mental canal. The location of the mental foramen below the apex of the lower second premolar (78%) was the most common. The maximum size of the mental foramen was 4.6+/-1.0 mm in width and 3.0+/-0.6 mm in height. The inner size of the mental canal was 2.6+/-0.6 mm in width and 2.1mm+/-0.4 mm in height. CONCLUSION : CBCT is useful to evaluate the anterior loop and mental foramen of the mandibular canal. Safe guideline of 4 mm from the most anterior point of the mental foramen is recommended for implant and surgical treatment.


Assuntos
Adulto , Humanos , Masculino , Dente Pré-Molar , Tomografia Computadorizada de Feixe Cônico
3.
Korean Journal of Oral and Maxillofacial Radiology ; : 27-33, 2009.
Artigo em Coreano | WPRIM | ID: wpr-15100

RESUMO

PURPOSE: The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. MATERIALS AND METHODS: Five partially edentulous dry human mandibles, with 1x1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographies were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0(R) (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. RESULTS: There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). CONCLUSION: Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.


Assuntos
Humanos , Tomografia Computadorizada de Feixe Cônico , Implantes Dentários , Guta-Percha , Mandíbula , Microcomputadores
4.
Korean Journal of Oral and Maxillofacial Radiology ; : 95-101, 2008.
Artigo em Coreano | WPRIM | ID: wpr-115518

RESUMO

PURPOSE: To assess the positional relationship between the maxillary sinus floor and the apex of the maxillary first molar using cone beam computed tomograph (CBCT). MATERIALS AND METHODS: CBCTs from 127 subjects were analysed. A total of 134 maxillary first molars were classified according to their vertical and horizontal positional relationship to the maxillary sinus floor and measured according to the distance between the maxillary sinus floor and the maxillary first molar. RESULTS: Type III (The root projected laterally on the sinus cavity but its apex is outside the sinus boundaries) was dominated between 10 and 19 years and type I (The root apex was not in contact with the cortical borders of the sinus) was dominated (P<0.05) between 20 and 72 years on the vertical relationship between the maxillary sinus floor and the apex of the maxillary first molar. The maxillary sinus floor was located more at the apex (78.2%) than at the furcation (21.3%) for the palatal root. The distance from the root apex to the maxillary sinus floor confined to type I was increased according to the ages (P<0.05). Type M (The maxillary sinus floor was located between the buccal and the palatal root) was most common (72.4%) on the horizontal relationship between the maxillary sinus floor and the apex of the maxillary first molar. CONCLUSION: CBCT can provide highly qualified images for the maxillary sinus floor and the root apex of the maxillary first molar.


Assuntos
Pisos e Cobertura de Pisos , Seio Maxilar , Dente Molar
5.
Korean Journal of Oral and Maxillofacial Radiology ; : 153-161, 2008.
Artigo em Coreano | WPRIM | ID: wpr-41311

RESUMO

PURPOSE: To compare and evaluate the diagnostic ability of cone beam computed tomography (CBCT) and magnetic resonance imaging (MRI) of the temporomandibular joint (TMJ). MATERIALS AND METHODS: CBCT and MRI of 46 TMJs of 23 patients with TMJ disorders were evaluated. They were divided into 3 groups according to the position of the articular disc of the TMJ at closed mouth position and the reduction of the disc during open mouth position on MRI : no disc displacement group (NDD), disc displacement with reduction group (DDR), and disc displacement without reduction group (DDWR). With PACS viewing softwares, position of mandibular condyle in the articular fossa, osseous change of mandibular condyle, shape of articular fossa, and mediolateral and anteroposterior dimensions of mandibular condyle were evaluated on CBCT and MRI. Each value was tested statistically. RESULTS: The position of mandibular condyle in the articular fossa were concentric in the NDD, DDR, and DDWR of CBCT and NDD of MRI. However, condyle was positioned posteriorly in DDR and DDWR of MRI. Flattening, sclerosis and osteophyte of the mandibular condyle were much more apparent on DDR of CBCT than MRI. And the erosion of the condyle was much more apparent on DDWR of MRI than CBCT. Box and Sigmoid types of articular fossa were found most frequently in DDR of MRI. Flattened type was found most frequently in DDR of CBCT and deformed type was found most frequently in DDWR of CBCT. No significant difference in mediolateral and anteroposterior dimensions were shown on CBCT and MRI. CONCLUSION: Since MRI and CBCT has unique diagnostic imaging ability, both modalities should be used together to supplement each other to evaluate TMJ.


Assuntos
Humanos , Colo Sigmoide , Tomografia Computadorizada de Feixe Cônico , Diagnóstico por Imagem , Deslocamento Psicológico , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Magnetismo , Imãs , Côndilo Mandibular , Boca , Osteófito , Esclerose , Articulação Temporomandibular , Transtornos da Articulação Temporomandibular
6.
Korean Journal of Oral and Maxillofacial Radiology ; : 169-176, 2008.
Artigo em Coreano | WPRIM | ID: wpr-41309

RESUMO

PURPOSE: To assess the diagnostic accuracy and value in an imaging technique field through the comparison of cone beam computed tomography and conventional panoramic radiography in assessing the topographic relationship between the mandibular canal and impacted third molars. MATERIALS AND METHODS: Participants consisted of 100 patients offered the images through cone beam computed tomography and panoramic radiography. PSR-9000(TM) Dental CT system (Asahi Roentgen Ind. Co., Ltd, Japan) was used as the unit of cone beam computed tomography. CE-II (Asahi Roentgen Ind. Co., Ltd, Japan) and Pro Max (Planmeca Oy, Finland) were used as the unit of panoramic radiography. The images obtained through panoramic radiography were classified into 3 types according to the distance between mandibular canal and root of mandibular third molar. And they were classified into 4 types according to the proximity of radiographic feature. The images obtained through cone beam computed tomography based on the classification above were classified into 4 types according to the location between the mandibular canal and the root and were analyzed. And they were classified into buccal, inferior, lingual, and between roots, according to the location between mandibular canal and root. The data were statistically analyzed and estimated by chi-square-test. RESULTS: 1. There was no statistical significance according to 3 types (type l, type ll, type lll) through CBCT. 2. The results of 4 types (type A, type B, type C, type D) through CBCT were as high prevalence of CBCT 1 in type A, CBCT 2 in type B, CBCT 3 in type C, and CBCT1 in type D and those of which showed statistical significance (P value=0.03). 3. The results according to location between mandibular canal and root through CBCT recorded each 49, 25, 17, 9 as buccal, inferior, lingual, between roots. CONCLUSION: When estimating the mandibular canal and the roots through the panoramic radiography, it could be difficult to drive the views of which this estimation was considerable. Thus it is required to have an accurate diagnostic approaching through CBCT that could estimate the location between mandibular canal and roots.


Assuntos
Humanos , Tomografia Computadorizada de Feixe Cônico , Nervo Mandibular , Dente Serotino , Prevalência , Radiografia Panorâmica
7.
Korean Journal of Oral and Maxillofacial Radiology ; : 1-5, 2008.
Artigo em Coreano | WPRIM | ID: wpr-78073

RESUMO

PURPOSE: The primary aims of this retrospective study were to compare subjective bone quality and bone quality based on the Hounsfield scale in different segments of the edentulous jaw, and to establish quantitative and objective assessment of the bone quality. MATERIALS AND METHODS: Twenty eight randomly selected cone-beam computed tomographic (CBCT) scans were analyzed. For evaluation one hundred and twelve edentulous areas were selected. Implant recipient sites were evaluated visually for Lekholm and Zarb classification. The same sites were subsequently evaluated digitally using the Hounsfield scale with Vimplant2.0(TM), and the results were correlated with visual classification. Data was subject for statistical analysis in order to determine correlation between recorded HU and the regions of the mouth with the Kruskal-Wallis test. RESULTS: The highest unit/mean density value (311 HU) was found in the anterior mandible, followed by 259 HU for the posterior mandible, 216 HU for the anterior maxilla, and 127 HU for the posterior maxilla. These results demonstrate a strong correlation for HU depending on the region of the mouth (p<0.001). The relationship between HU and type 4 bone was found to be significant (r=0.74). CONCLUSION: Knowledge of the Hounsfield value as a quantitative measurement of bone density can be helpful as a diagnostic tool by using CBMercuRay(TM) with Vimplant(TM) software.


Assuntos
Densidade Óssea , Tomografia Computadorizada de Feixe Cônico , Arcada Edêntula , Mandíbula , Maxila , Boca , Estudos Retrospectivos
8.
Korean Journal of Oral and Maxillofacial Radiology ; : 7-15, 2008.
Artigo em Coreano | WPRIM | ID: wpr-78072

RESUMO

PURPOSE: This study provides comparative measurements of absorbed and effective doses for newly developed cone beam computed tomography (CT) in comparison with these doses for conventional CT. MATERIALS AND METHODS: Thermoluminescent dosimeter rods (TLD rod: GR-200, Thermo Fisher Scientific Inc., Waltham, MA, USA) were placed at 25 sites throughout the layers of Male ART Head and Neck Phantom (Radiology Support Devices Inc., Long Beach, USA) for dosimetry. Implagraphy, DCT Pro (Vatech Co., Hwasung, Korea) units, SCT-6800TXL (Shimadzu Corp., Kyoto, Japan), and Cranex 3+ (Soredex Orion Corp., Helsinki, Finland) were used for radiation exposures. Absorption doses were measured with Harshaw 3500TLD reader (Thermo Fisher Scientific Inc., Waltham, MA, USA). Radiation weighted doses and effective doses were measured and calculated by 2005 ICRP tissue weighting factors. RESULTS: Absorbed doses in Rt. submandibular gland were 110.57 mGy for SCT 6800TXL (Implant), 24.56 mGy for SCT 6800TXL (3D), 22.39 mGy for Implagraphy3, 7.19 mGy for DCT Pro, 5.96 mGy for Implagraphy1, 0.70 mGy for Cranex 3+. Effective doses (E2005draft) were 2.551 mSv for SCT 6800TXL (Implant), 1.272 mSv for SCT 6800TXL (3D), 0.598 mSv for Implagraphy3, 0.428 mSv for DCT Pro and 0.146 mSv for Implagraphy1. These are 108.6, 54.1, 25.5, 18.2 and 6.2 times greater than panoramic examination (Cranex 3+) doses (0.023 mSv). CONCLUSION: Cone beam CT machines recently developed in Korea, showed lower effective doses than conventional CT. Cone beam CT provides a lower dose and cost alternative to conventional CT, promising to revolutionize the practice of oral and maxillofacial radiology.


Assuntos
Humanos , Masculino , Absorção , Tomografia Computadorizada de Feixe Cônico , Cabeça , Coreia (Geográfico) , Pescoço , Radiografia Panorâmica , Radiometria , Glândula Submandibular , Tomografia Computadorizada por Raios X
9.
Korean Journal of Oral and Maxillofacial Radiology ; : 17-22, 2008.
Artigo em Coreano | WPRIM | ID: wpr-78071

RESUMO

PURPOSE: It is important to determine the bucco-lingual inclination of implants on radiographs before the implant surgery. The purpose of this study was to compare the buccolingual inclination in alveolar bone and the tooth with dental cone beam CT and to prepare the standard for the buccolingual inclination of implant. MATERIALS AND METHODS: Axial, panoramic, and buccolingually sectioned images of 80 implant cases with stent including straight marker using CB Mercuray(TM) (Hitachi, Japan) were evaluated. The comparison of the buccolingual inclination of remained alveolar bone with the tooth and the marker on buccolingually sectioned views was performed statistically. RESULTS: The average buccolingual inclination of remained alveolar bone and tooth was 82.8+/-4.6degrees and 85.8+/-4.7degrees (p0.05, r=0.12) at the 2nd premolar area in upper jaw. The average buccolingual inclination of remained alveolar bone and tooth was 81.3+/-8.3degrees and 87.5+/-6.3degrees (p>0.05, r=0.85) at the lower 2nd premolar area and 94.3+/-6.6degrees and 93.3+/-7.2degrees respectively (p>0.05, r=0.91) at the 1st molar area in lower jaw. The inclinations of markers were very different from those of remained bone at the most of areas except the upper 2nd premolar area (r=0.79). CONCLUSION: We recommend dental CBCT analysis for determining the buccolingual inclination of dental implant, because of significant difference, in average, between the buccolingual inclination of remained alveolar bone and tooth.


Assuntos
Dente Pré-Molar , Tomografia Computadorizada de Feixe Cônico , Implantes Dentários , Arcada Osseodentária , Dente Molar , Stents , Dente
10.
Korean Journal of Oral and Maxillofacial Radiology ; : 23-27, 2008.
Artigo em Coreano | WPRIM | ID: wpr-78070

RESUMO

PURPOSE: The aim of this study was to evaluate the change in the position of the mandibular condyle within articular fossa by a CBCT after wearing complete denture (CD). MATERIALS AND METHODS: CBCT of 34 temporomandibular joints were taken from 9 male and 8 female patients with CB Mercuray(TM) (Hitachi, Japan) before and after wearing a CD for rehabilitation. Position of mandibular condyle within articular fossa at centric occlusion was evaluated with Vimplant2.0(TM) (CyberMed, Korea) on the central parasagittal view and curved panoramic coronal view of the condylar head. A statistical evaluation was done with SPSS. RESULTS: The range of anteroposterior positional rate (AP) of condylar head within articular fossa was -16-5 and -10-12 respectively on the right and left sides. Before wearing CD, the AP rate showed discrepancy between right and left sides (p<0.05). After wearing CD, both condyles showed a tendency to decrease in posterior condylar position (right side; p<0.05). The average discrepancy between right and left side in mediolateral positional rate (MD) was 15.5 and 4.5 respectively before and after wearing CD. The improvement was observed in mediolateral relationship of both condylar heads after wearing CD (p<0.01). Before wearing CD, the average horizontal angle of long axis of condylar head was 79.6+/-2.7degrees and 80.1+/-5.7degrees respectively on the right and left sides. After wearing CD, both condyles were rotated in the same direction in average on axial plane. CONCLUSION: We observed with CBCT the significant clinical evidence in case of positional change of mandibular condyle after wearing complete denture.


Assuntos
Feminino , Humanos , Masculino , Vértebra Cervical Áxis , Tomografia Computadorizada de Feixe Cônico , Prótese Total , Cabeça , Côndilo Mandibular , Articulação Temporomandibular
11.
Korean Journal of Oral and Maxillofacial Radiology ; : 49-56, 2008.
Artigo em Coreano | WPRIM | ID: wpr-78067

RESUMO

PURPOSE: Diagnostic estimation of destruction and formation of bone has the typical limit according to capacity of x-ray generator and image detector. So the aim of this study was to find out how much it can reproduce the shape and the density of bone in the case of using recently developed dental type of cone beam computed tomography, and which image is applied by new detector and mathematic calculation. MATERIALS AND METHODS: Cone beam computed tomography (PSR 9000N, Asahi Roentgen Ind. Co., Ltd., Japan) and soft x-ray radiography were executed on dry mandible that was already decalcified during 5 hours, 10 hours, 15 hours, 20 hours, and 25 hours. Estimating and comparing of those came to the following results. RESULTS: The change of inferior border of mandible and anterior border of ramus in the region of cortical bone was observed between first 5 and 10 hours of decalcification. The reproduction of shape and density in the region of cortical bone and cancellous bone can be hardly observed at cone beam computed tomography compared with soft x-ray radiography. The difference of decrease of bone density according to hours of decalcification increase wasn't reproduced at cone beam computed tomography compared with soft x-ray radiography. CONCLUSION: CBCT images revealed higher spatial resolution. However, contrast resolution in region of low contrast sensitivity is the inferiority of images' property.


Assuntos
Densidade Óssea , Tomografia Computadorizada de Feixe Cônico , Sensibilidades de Contraste , Mandíbula , Matemática , Porfirinas , Reprodução
12.
Korean Journal of Oral and Maxillofacial Radiology ; : 197-203, 2007.
Artigo em Inglês | WPRIM | ID: wpr-13527

RESUMO

PURPOSE: To provide diagnostic information by evaluation of the positional relationship between the mandibular third molar and the mandibular canal. MATERIALS AND METHODS: Eighty-nine mandibular third molars were classified as mesioangular, horizontal, vertical, distoangular groups. The distances between the mandibular third molar and the mandibular canal were measured in cone-beam computed tomographs. The height and width ratios of distances from the mandibular third molar and the mandibular canal to the mandibular inferior border and to the lingual cortical plate were calculated. RESULTS: The vertical and buccolingual distances between the mandibular third molar and the mandibular canal were 0.03 mm, 2.96 mm in the mesioangular, 0.37 mm, 3.38 mm in the horizontal, -1.50 mm, 1.38 mm in the vertical, -1.10 mm, 4.20 mm in the distoangular group. There were significant differences in vertical (P0.05). The height and width ratios of distances on the mandibular third molar were 47.1%, 36.1% in the mesioangular, 47.4%, 34.4% in the horizontal, 37.0%, 46.7% in the vertical, 40.9%, 37.4% in the distoangular group. There were significant differences between the mesioangular and the vertical group, and the horizontal and the vertical group in height ratio (P0.05). CONCLUSION: The mesioangular group showed the nearest distance between the mandibular third molar and the mandibular canal vertically. The root apex of the mandibular third molar was positioned more buccally in the vertical group than in the mesioangular group.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Dente Serotino
13.
Korean Journal of Oral and Maxillofacial Radiology ; : 205-209, 2007.
Artigo em Inglês | WPRIM | ID: wpr-13526

RESUMO

PURPOSE: To determine the physical properties of a newly developed cone beam computed tomography (CBCT). MATERIALS AND METHODS: We measured and compared the imaging properties for the indirect-type flat panel detector (FPD) of a new CBCT and the single detector array (SDA) of conventional helical CT (CHCT). RESULTS: First, the modulation transfer function (MTF) of the CBCT were superior to those of the CHCT. Second, the noise power spectrum (NPS) of the CBCT were worse than those of the CHCT. Third, detective quantum efficiency (DQE) of the indirect-type CBCT were worse than those of the CHCT at lower spatial frequencies, but were better at higher spatial frequencies. Although the comparison of contrast-to-noise ratio (CNR) was estimated in the limited range of tube current, CNR of CBCT were worse than those of CHCT. CONCLUSION: This study shows that the indirect-type FPD system may be useful as a CBCT detector because of high resolution.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Ruído , Tomografia Computadorizada Espiral
14.
Korean Journal of Oral and Maxillofacial Radiology ; : 69-77, 2007.
Artigo em Coreano | WPRIM | ID: wpr-134261

RESUMO

PURPOSE: To evaluate the accuracy of the imaging reformation of cone beam computed tomography for the assessment of bone defect healing in rat model. MATERIALS AND METHODS: Sprague-Dawley strain rats weighing about 350 gms were selected. Then critical size bone defects were done at parietal bone with implantation of collagen sponge. The rats were divided into seven groups of 3 days, 1 week, 2 weeks, 3 weeks, 4 weeks, 6 weeks, and 8 weeks. The healing of surgical defect was assessed by multiplanar reconstruction (MPR) images and three-dimensional (3-D) images of cone beam computed tomography, compared with soft X-ray radiograph and histopathologic examination. RESULTS: MPR images and 3-D images showed similar reformation of the healing amount at 3 days, 1 week, 2 weeks, and 8 weeks, however, lower reformation at 3 weeks, 4 weeks, and 6 weeks. According to imaging-based methodologies, MPR image revealed similar reformation of the healing amount than 3-D images compare with soft X-ray image. Among the four threshold values for 3-D images, 400-500 HU revealed similar reformation of the healing amount. Histopathologic examination confirmed the newly formed trabeculation correspond with imagingbased methologies. CONCLUSION: MPR images revealed higher accuracy of the imaging reformation of cone beam computed tomography and cone beam computed tomography is a clinically useful diagnostic tool for the assessment of bone defect healing.


Assuntos
Animais , Ratos , Colágeno , Tomografia Computadorizada de Feixe Cônico , Imageamento Tridimensional , Modelos Animais , Osso Parietal , Poríferos , Ratos Sprague-Dawley
15.
Korean Journal of Oral and Maxillofacial Radiology ; : 69-77, 2007.
Artigo em Coreano | WPRIM | ID: wpr-134260

RESUMO

PURPOSE: To evaluate the accuracy of the imaging reformation of cone beam computed tomography for the assessment of bone defect healing in rat model. MATERIALS AND METHODS: Sprague-Dawley strain rats weighing about 350 gms were selected. Then critical size bone defects were done at parietal bone with implantation of collagen sponge. The rats were divided into seven groups of 3 days, 1 week, 2 weeks, 3 weeks, 4 weeks, 6 weeks, and 8 weeks. The healing of surgical defect was assessed by multiplanar reconstruction (MPR) images and three-dimensional (3-D) images of cone beam computed tomography, compared with soft X-ray radiograph and histopathologic examination. RESULTS: MPR images and 3-D images showed similar reformation of the healing amount at 3 days, 1 week, 2 weeks, and 8 weeks, however, lower reformation at 3 weeks, 4 weeks, and 6 weeks. According to imaging-based methodologies, MPR image revealed similar reformation of the healing amount than 3-D images compare with soft X-ray image. Among the four threshold values for 3-D images, 400-500 HU revealed similar reformation of the healing amount. Histopathologic examination confirmed the newly formed trabeculation correspond with imagingbased methologies. CONCLUSION: MPR images revealed higher accuracy of the imaging reformation of cone beam computed tomography and cone beam computed tomography is a clinically useful diagnostic tool for the assessment of bone defect healing.


Assuntos
Animais , Ratos , Colágeno , Tomografia Computadorizada de Feixe Cônico , Imageamento Tridimensional , Modelos Animais , Osso Parietal , Poríferos , Ratos Sprague-Dawley
16.
Korean Journal of Oral and Maxillofacial Radiology ; : 87-92, 2007.
Artigo em Coreano | WPRIM | ID: wpr-134255

RESUMO

Purpose: To measure the absorbed doses of cone beam computed tomography (CBCT), which is recently being more frequently used, and to compare them with those of panoramic radiography. Materials and Methods: To measure the absorbed doses of CBCT (PSR-9000N(TM), Asahi Roentgen Ind. Co., Japan), we placed TLD chips on the skin regions above the parotid and thyroid glands, and on the dorsum of tongue in a dental head phantom. We used two image acquisition modes of the Dental and Panoramic modes of CBCT, which differed in the field of view. Also, panoramic radiographs (Auto IIIN, Asahi Roentgen Ind. Co., Japan) were taken to compare with the absorbed doses of CBCT. Result: In the Dental mode of CBCT, the absorbed doses of the parotid gland, dorsum of tongue, and thyroid gland were 3.53, 3.13, and 0.36 mGy, respectively. In the Panoramic mode of CBCT, they were 9.57, 9.15, and 0.85 mGy, respectively. The panoramic mode showed higher absorbed doses than those of the Dental mode. In the panoramic radiography, the absorbed doses of the parotid gland, dorsum of tongue, and thyroid gland were 1.21, 1.19, and 0.16 mGy, respectively. And they were about 1/3 of the Dental mode and 1/9 of the Panoramic mode of CBCT. Conclusion: Absorbed doses of CBCT are higher than those of panoramic radiography, and dependent upon the field of view.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Cabeça , Glândula Parótida , Doses de Radiação , Radiografia Panorâmica , Pele , Glândula Tireoide , Língua
17.
Korean Journal of Oral and Maxillofacial Radiology ; : 87-92, 2007.
Artigo em Coreano | WPRIM | ID: wpr-134254

RESUMO

Purpose: To measure the absorbed doses of cone beam computed tomography (CBCT), which is recently being more frequently used, and to compare them with those of panoramic radiography. Materials and Methods: To measure the absorbed doses of CBCT (PSR-9000N(TM), Asahi Roentgen Ind. Co., Japan), we placed TLD chips on the skin regions above the parotid and thyroid glands, and on the dorsum of tongue in a dental head phantom. We used two image acquisition modes of the Dental and Panoramic modes of CBCT, which differed in the field of view. Also, panoramic radiographs (Auto IIIN, Asahi Roentgen Ind. Co., Japan) were taken to compare with the absorbed doses of CBCT. Result: In the Dental mode of CBCT, the absorbed doses of the parotid gland, dorsum of tongue, and thyroid gland were 3.53, 3.13, and 0.36 mGy, respectively. In the Panoramic mode of CBCT, they were 9.57, 9.15, and 0.85 mGy, respectively. The panoramic mode showed higher absorbed doses than those of the Dental mode. In the panoramic radiography, the absorbed doses of the parotid gland, dorsum of tongue, and thyroid gland were 1.21, 1.19, and 0.16 mGy, respectively. And they were about 1/3 of the Dental mode and 1/9 of the Panoramic mode of CBCT. Conclusion: Absorbed doses of CBCT are higher than those of panoramic radiography, and dependent upon the field of view.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Cabeça , Glândula Parótida , Doses de Radiação , Radiografia Panorâmica , Pele , Glândula Tireoide , Língua
18.
Korean Journal of Oral and Maxillofacial Radiology ; : 93-102, 2007.
Artigo em Coreano | WPRIM | ID: wpr-134253

RESUMO

PURPOSE: Cone beam computed tomography (CBCT) provides a lower dose and cost alternative to conventional CT, promising to revolutionize the practice of oral and maxillofacial radiology. The purpose of this study was to evaluate the absorbed and effective doses of Implagraphy and VCT (Vatech Co., Hwasung, Korea) and compare them with those of panoramic radiography. MATERIALS AND METHODS: Thermoluminescent dosimeter (TLD) chips were placed at 27 sites throughout the layers of Female ART Head and Neck Phantom for dosimetry. Implagraphy, VCT units, and Planmeca Proline XC panoramic unit were used for radiation exposures. Radiation weighted doses and effective doses were measured and calculated using 1990 and 2005 ICRP tissue weighting factors. RESULTS: Effective doses in Sv (ICRP 2005, ICRP 1990) were 90.19, 61.62 for Implagraphy at maxillay molar area, 123.20, 90.02 for Implagraphy at mandibular molar area, 183.55, 139.26 for VCT and 40.92, 27.16 for panoramic radiography. CONCLUSION: Effective doses for VCT and Implagraphy were only about 2.2 to 4.5 times greater than those for panoramic radiography. VCT and Implagraphy, CBCT machines recently developed in Korea, showed moderately low effective doses.


Assuntos
Feminino , Humanos , Tomografia Computadorizada de Feixe Cônico , Cabeça , Coreia (Geográfico) , Dente Molar , Pescoço , Prolina , Radiografia Panorâmica
19.
Korean Journal of Oral and Maxillofacial Radiology ; : 93-102, 2007.
Artigo em Coreano | WPRIM | ID: wpr-134252

RESUMO

PURPOSE: Cone beam computed tomography (CBCT) provides a lower dose and cost alternative to conventional CT, promising to revolutionize the practice of oral and maxillofacial radiology. The purpose of this study was to evaluate the absorbed and effective doses of Implagraphy and VCT (Vatech Co., Hwasung, Korea) and compare them with those of panoramic radiography. MATERIALS AND METHODS: Thermoluminescent dosimeter (TLD) chips were placed at 27 sites throughout the layers of Female ART Head and Neck Phantom for dosimetry. Implagraphy, VCT units, and Planmeca Proline XC panoramic unit were used for radiation exposures. Radiation weighted doses and effective doses were measured and calculated using 1990 and 2005 ICRP tissue weighting factors. RESULTS: Effective doses in Sv (ICRP 2005, ICRP 1990) were 90.19, 61.62 for Implagraphy at maxillay molar area, 123.20, 90.02 for Implagraphy at mandibular molar area, 183.55, 139.26 for VCT and 40.92, 27.16 for panoramic radiography. CONCLUSION: Effective doses for VCT and Implagraphy were only about 2.2 to 4.5 times greater than those for panoramic radiography. VCT and Implagraphy, CBCT machines recently developed in Korea, showed moderately low effective doses.


Assuntos
Feminino , Humanos , Tomografia Computadorizada de Feixe Cônico , Cabeça , Coreia (Geográfico) , Dente Molar , Pescoço , Prolina , Radiografia Panorâmica
20.
Korean Journal of Oral and Maxillofacial Radiology ; : 103-110, 2007.
Artigo em Coreano | WPRIM | ID: wpr-134251

RESUMO

PURPOSE: To examine the danger zone of mesial root of mandibular first molar of patient without extraction using CBCT(cone -beam computed tomography) to avoid the risk of root perforation. MATERIALS AND METHODS: 20 mandibular first molars without caries and restorations were collected. CT images were obtained by CBCT(PSR9000N TM, Asahi Roentgen Co., Japan), reformed and analyzed by V-work 5.0 (CyberMed Inc., Korea). Distance between canal orifice and furcation was measured. In cross sectional images at 3, 4 and 5 mm below the canal orifice, distal wall thickness of mesiobuccal canal (MB-D), distal wall thickness of mesiolingual canal (ML-D), distal wall thickness of central part (C-D), mesial wall thickness of mesiobuccal canal (MB-M) and mesial wall thickness of mesiolingual canal (ML-M) were measured. RESULTS: The mean distance between the canal orifice and the furcation of the roots is 2.40 mm. Distal wall is found to be thinner than mesial wall. Mean dentinal wall thickness of distal wall is about 1 mm. The wall thickness is thinner as the distance from the canal orifice is farther. But significant differences are not noted between 4 mm and 5 mm in MB-D and C-D. MB-D is thinner than ML-D although the differences is not significant. CONCLUSION: The present study confirmed the anatomical weakness of distal surface of the coronal part of the mesial roots of mandibular first molar by CBCT and provided an anatomical guide line of wall thickness during endodontic treatment.


Assuntos
Humanos , Tomografia Computadorizada de Feixe Cônico , Dentina , Dente Molar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA