Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Acta Academiae Medicinae Sinicae ; (6): 280-284, 2023.
Artigo em Chinês | WPRIM | ID: wpr-981264

RESUMO

Objective To explore the optimal parameters for virtual mono-energetic imaging of liver solid lesions. Methods A retrospective analysis was performed on 60 patients undergoing contrast-enhanced spectral CT of the abdomen.The iodine concentration values of hepatic arterial phase images and the CT values of different mono-energetic images were measured.The correlation coefficient and coefficient of variation were calculated. Results The average correlation coefficients between iodine concentrations and CT values of hepatic solid lesion images at 40,45,50,55,60,65,and 70 keV were 0.996,0.995,0.993,0.989,0.978,0.970,and 0.961,respectively.The correlation coefficients at 40(P=0.007),45(P=0.022),50 keV (P=0.035)were higher than that at 55 keV,and the correlation coefficients at 40 keV(P=0.134) and 45 keV(P=0.368) had no significant differences from that at 50 keV.The coefficients of variation of the CT values at 40,45,and 50 keV were 0.146,0.154,and 0.163,respectively. Conclusion The energy of 40 keV is optimal for virtual mono-energetic imaging of liver solid lesions in the late arterial phase,which is helpful for the diagnosis of liver diseases.


Assuntos
Humanos , Tomografia Computadorizada por Raios X , Estudos Retrospectivos , Abdome , Iodo , Fígado/diagnóstico por imagem , Razão Sinal-Ruído , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
2.
Acta Academiae Medicinae Sinicae ; (6): 359-363, 2020.
Artigo em Chinês | WPRIM | ID: wpr-826356

RESUMO

To evaluate the effect of monochromatic energy image on inferior vena cava imaging quality on dual-layer detector spectral CT. Totally 39 patients who were clinically suspected of abdominal disease and referred to perform contrast-enhanced computed tomography(CT)were prospectively enrolled and underwent abdominal examination using a single-source,dual-detector spectral CT.The delayed phase scan was performed 3 minutes after injection of 60 ml of iopamidol(320 mg/ml)at a rate of 3 ml/s.The raw images were reconstructed to obtain conventional mixed energy images and spectral based images(SBI).The 40,50,60,and 70 keV single energy images were obtained.The CT value,noise,and signal-to-noise(SNR)of inferior vena cava and the contrast-to-noise(CNR)of inferior vena cava relative to psoas major on conventional mixed energy images and the 40,50,60,70 keV single energy images were measured.The SNRs and CNRs on monoenergetic 40-70 keV images were compared with polychromatic 120 kVp images.ANOVA was used to compare the CT value,noise,SNR,and CNR among these five groups.The optimal monoenergetic image set was chosen. The differences in CT value,noise,SNR,CNR of inferior vena cava were statistically significant among five groups(all <0.05).The SNR and CNR in 40 keV group and 50 keV group were significantly higher than those in other groups(all <0.05).The SNR of 40 keV group was significantly higher than that of 50 keV group(=0.002).The CNR of 40 keV group was not statistical different compared with that of 50 keV group(=0.630). 40 keV is the optimal monoenergetic energy level for the inferior vena cava on dual-layer detector spectral CT and may be valuable for the diagnosis of inferior vena cava disease.


Assuntos
Humanos , Abdome , Interpretação de Imagem Radiográfica Assistida por Computador , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X , Veia Cava Inferior
SELEÇÃO DE REFERÊNCIAS