1.
Journal of Central South University(Medical Sciences) ; (12): 76-83, 2023.
Artigo em Inglês | WPRIM | ID: wpr-971372

RESUMO

OBJECTIVES@#Magnetic resonance diffusion-weighted imaging (DWI) has important clinical value in diagnosis and curative effect evaluation on endometrial carcinoma. How to improve the detection rate of endometrial small lesions by DWI is the research focus of MRI technology. This study aims to analyze the image quality of small field MRI ZOOMit-DWI sequence and conventional single-shot echo-planar imaging (SS-EPI) DWI sequence in the scanning of endometrial carcinoma, and to explore the clinical value of ZOOMit-DWI sequence.@*METHODS@#A total of 37 patients with endometrial carcinoma diagnosed by operation and pathology in the Second Xiangya Hospital of Central South University from July 2019 to May 2021 were collected. All patients were scanned with MRI ZOOMit-DWI sequence and SS-EPI DWI sequence before operation. Two radiologists subjectively evaluated the anatomical details, artifacts, geometric deformation and focus definition of the 2 groups of DWI images. At the same time, the signal intensity were measured and the signal-to-noise ratio (SNR), contrast to noise ratio (CNR), and apparent diffusion coefficient (ADC) of the 2 DWI sequences were calculated for objective evaluation. The differences of subjective score, objective score and ADC value of the 2 DWI sequences were analyzed.@*RESULTS@#The SNR of the ZOOMit-DWI group was significantly higher than that of the SS-EPI DWI group (301.96±141.85 vs 94.66±41.26), and the CNR of the ZOOMit-DWI group was significantly higher than that of the SS-EPI DWI group (185.05±105.45 vs 57.91±31.54, P<0.05). There was no significant difference in noise standard deviation between the ZOOMit-DWI group and the SS-EPI DWI group (P>0.05). The subjective score of anatomical detail and focus definition in the ZOOMit-DWI group was significantly higher than that of the SS-EPI DWI group (both P<0.05). The subjective score of artifacts and geometric deformation of ZOOMit-DWI group was significantly lower than that of the SS-EPI DWI group (both P<0.05). ADC had no significant difference between the ZOOMit-DWI group and the SS-EPI DWI group (P>0.05).@*CONCLUSIONS@#The image quality of ZOOMit-DWI is significantly higher than that of conventional SS-EPI DWI. In the MRI DWI examination of endometrial carcinoma, ZOOMit-DWI can effectively reduce the geometric deformation and artifacts of the image, which is more conducive to clinical diagnosis and treatment.


Assuntos
Feminino , Humanos , Razão Sinal-Ruído , Neoplasias do Endométrio/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Endométrio , Imagem Ecoplanar/métodos , Reprodutibilidade dos Testes
2.
Korean Journal of Radiology ; : 403-410, 2014.
Artigo em Inglês | WPRIM | ID: wpr-109973

RESUMO

OBJECTIVE: The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. MATERIALS AND METHODS: Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of diffusion-weighted (DW) images. To evaluate geometric distortion, a comparison was made between lesion lengths derived from contrast enhanced MR (CE-MR) images and those obtained from the corresponding DW images. For assessment of image parameters, signal-to-noise ratio (SNR), lesion contrast, and contrast-to-noise ratio (CNR) were calculated. RESULTS: The rs-EPI was superior to ss-EPI in most criteria regarding the qualitative image quality. Anatomical structure distinction, delineation of the lesion, ghosting artifact, and overall image quality were significantly better in rs-EPI. Regarding the geometric distortion, lesion length on ss-EPI was significantly different from that of CE-MR, whereas there were no significant differences between CE-MR and rs-EPI. The rs-EPI was superior to ss-EPI in SNR and CNR. CONCLUSION: Readout-segmented EPI is superior to ss-EPI in the aspect of image quality in DW MR imaging of the breast.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Artefatos , Mama/patologia , Neoplasias da Mama/patologia , Meios de Contraste , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Aumento da Imagem/métodos , Variações Dependentes do Observador , Estudos Retrospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído
3.
Korean Journal of Radiology ; : 736-742, 2012.
Artigo em Inglês | WPRIM | ID: wpr-39921

RESUMO

OBJECTIVE: It was reported lately that to obtain consistent liver T1rho measurement, at 3T MRI using six spin-lock times (SLTs), is feasible. In this study, the feasibility of using three or two SLT points to measure liver T1rho relaxation time was explored. MATERIALS AND METHODS: Seventeen healthy volunteers underwent 36 examinations. Three representative axial slices were selected to cut through the upper, middle, and lower liver. A rotary echo spin-lock pulse was implemented in a 2D fast field echo sequence. Spin-lock frequency was 500 Hz and the spin-lock times of 1, 10, 20, 30, 40, and 50 milliseconds (ms) were used for T1rho mapping. T1rho maps were constructed by using all 6 SLT points, three SLT points of 1, 20, and 50 ms, or two SLTs of 1 and 50 ms, respectively. Intra-class correlation coefficient (ICC) and Bland and Altman plot were used to assess the measurement agreement. RESULTS: Two examinations were excluded, due to motion artifact at the SLT of 50 ms. With the remaining 34 examinations, the ICC for 6-SLT vs. 3-SLT T1rho measurements was 0.922, while the ICC for 6-SLT vs. 2-SLT T1rho measurement was 0.756. The Bland and Altman analysis showed a mean difference of 0.19 (95% limits of agreement: -1.34, 1.73) for 6-SLT vs. 3-SLT T1rho measurement, and the mean difference of 0.89 (95% limits of agreement: -1.67, 3.45) for 6-SLT vs. 2-SLT T1rho measurement. The scan re-scan reproducibility ICC (n = 11 subjects) was 0.755, 0.727, and 0.528 for 6-SLT measurement, 3-SLT measurement, and 2-SLT measurement, respectively. CONCLUSION: Adopting 3 SLTs of 1, 20, and 50 ms can be an acceptable alternative for the liver T1rho measurement, while 2 SLTs of 1 and 50 ms do not provide reliable measurement.


Assuntos
Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Ingestão de Alimentos , Imagem Ecoplanar/métodos , Jejum , Fígado/anatomia & histologia , Imageamento por Ressonância Magnética/métodos
4.
Korean Journal of Radiology ; : 295-303, 2010.
Artigo em Inglês | WPRIM | ID: wpr-183840

RESUMO

OBJECTIVE: To evaluate whether the histopathological differentiation and the expression of vascular endothelial growth factor (VEGF) of hepatocellular carcinoma (HCC) do show correlation with the apparent diffusion coefficient (ADC) value on diffusion-weighted imaging (DWI). MATERIALS AND METHODS: Twenty-seven HCCs from 27 patients who had undergone preoperative liver MRI (1.5T) and surgical resection were retrospectively reviewed. DWI was obtained with a single-shot, echo-planar imaging sequence in the axial plane (b values: 0 and 1,000 sec/mm2). On DWIs, the ADC value of the HCCs was measured by one radiologist, who was kept 'blinded' to the histological findings. Histopathologically, the differentiation was classified into well (n = 9), moderate (n = 9) and poor (n = 9). The expression of VEGF was semiquantitatively graded as grade 0 (n = 8), grade 1 (n = 9) and grade 2 (n = 10). We analyzed whether the histopathological differentiation and the expression of VEGF of the HCC showed correlation with the ADC value on DWI. RESULTS: The mean ADC value of the poorly-differentiated HCCs (0.9 +/- 0.13x10(-3) mm2/s) was lower than those of the well-differentiated HCCs (1.2 +/- 0.22x10(-3) mm2/s) (p = 0.031) and moderately-differentiated HCCs (1.1 +/- 0.01x10(-3) mm2/s) (p = 0.013). There was a significant correlation between the differentiation and the ADC value of the HCCs (r = -0.51, p = 0.012). The mean ADC of the HCCs with a VEGF expression grade of 0, 1 and 2 was 1.1 +/- 0.17, 1.1 +/- 0.21 and 1.1 +/- 0.18x10(-3) mm2/s, respectively. The VEGF expression did not show correlation with the ADC value of the HCCs (r = 0.07, p = 0.74). CONCLUSION: The histopathological differentiation of HCC shows inverse correlation with the ADC value. Therefore, DWI with ADC measurement may be a valuable tool for noninvasively predicting the differentiation of HCC.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Carcinoma Hepatocelular/metabolismo , Diferenciação Celular , Meios de Contraste , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Gadolínio DTPA , Aumento da Imagem/métodos , Fígado/metabolismo , Neoplasias Hepáticas/metabolismo , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Fator A de Crescimento do Endotélio Vascular/metabolismo
5.
Korean Journal of Radiology ; : 359-363, 2010.
Artigo em Inglês | WPRIM | ID: wpr-183832

RESUMO

We report a case of intracranial foreign body granuloma that showed features of a high grade tumor on magnetic resonance (MR) imaging. However, the relative cerebral blood volume was not increased in the enhancing mass on perfusion MRI and the choline/creatine ratio only slightly increased on MR spectroscopy. The results suggest that the lesion is benign in nature. Perfusion MRI and MR spectroscopy may be helpful to differentiate a foreign body granuloma from a neoplastic condition.


Assuntos
Adulto , Feminino , Humanos , Volume Sanguíneo , Encéfalo/patologia , Meios de Contraste , Diagnóstico Diferencial , Imagem Ecoplanar/métodos , Seguimentos , Gadolínio , Granuloma de Corpo Estranho/patologia , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos
6.
Indian J Physiol Pharmacol ; 2007 Jan-Mar; 51(1): 81-5
Artigo em Inglês | IMSEAR | ID: sea-107617

RESUMO

Brain mechanisms for the refractory period that characteristically follows ejaculation in animals and human are poorly understood. The possibility of active inhibition of brain areas being responsible for the post-ejaculatory inhibitory state has not been ruled out. Using Blood Oxygen Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) we have mapped brain areas in healthy young volunteers immediately after ejaculation. Functional imaging of the brain for 30 minutes beginning after three minutes of ejaculation induced by masturbation showed spatio-temporal activation in amygdala, temporal lobes and septal areas. The septal areas were observed to be active for a shorter duration than the amygdala and the temporal lobe. Thus the temporal sequence of involvement of the above neural structures may contribute to temporary inhibition of sexual arousal/penile erection during the post-ejaculatory refractory period in humans.


Assuntos
Adulto , Tonsila do Cerebelo/fisiologia , Encéfalo/fisiologia , Imagem Ecoplanar/métodos , Ejaculação/fisiologia , Lobo Frontal/fisiologia , Giro do Cíngulo/fisiologia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Masturbação , Área Pré-Óptica/fisiologia , Tempo de Reação , Período Refratário Eletrofisiológico/fisiologia , Septo do Cérebro/fisiologia , Lobo Temporal/fisiologia , Fatores de Tempo
7.
Artigo em Inglês | IMSEAR | ID: sea-42931

RESUMO

OBJECTIVE: To determine the difference of mean apparent diffusion coefficients (ADC) among different patterns of focal multiple sclerosis (MS) lesions, to compare mean lesion ADC between 2 clinical subgroups and to correlate mean lesion ADC with disability. MATERIAL AND METHOD: Thirty seven patients (26 with relapsing-remitting multiple sclerosis (MS) and 11 with secondary-progressive MS) underwent both conventional and diffusion-weighted MR imaging of the brain. After creating ADC maps, region identification was done by using b = 0 images and T2-weighted images. ADC values were measured for MS lesions and (NAWM). RESULTS: A total of 288 lesions were identified on the images. The mean ADC for the lesions was significantly higher than that of NAWM Hypointense T1 lesions (n = 221) had a significantly higher mean ADC than isointense T1 lesions (n = 67) in both nonenhancing lesions (n = 250) and enhancing lesions (n = 38). The enhanced rim of ring-enhancing lesions (n = 18) had lower ADC than the central nonenhanced portions. Confluent lesions (n = 62) had a substantially higher mean ADC than discrete lesion (n = 226). Mean lesion ADC of secondary progressive MS was significantly higher than relapsing remitting MS. No correlation between mean lesion ADC and (EDSS) score was found CONCLUSION: Quantitative diffusion-weighted imaging is useful to elucidate the heterogeneous pathological substrate of MS in different patterns of MS lesions, to differentiate 2 major clinical subgroups.


Assuntos
Adolescente , Adulto , Fatores Etários , Estudos de Coortes , Intervalos de Confiança , Imagem de Difusão por Ressonância Magnética/métodos , Avaliação da Deficiência , Progressão da Doença , Imagem Ecoplanar/métodos , Feminino , Seguimentos , Gadolínio DTPA/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/diagnóstico , Esclerose Múltipla Crônica Progressiva/diagnóstico , Esclerose Múltipla Recidivante-Remitente/diagnóstico , Estudos Retrospectivos , Medição de Risco , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Fatores Sexuais , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA