Your browser doesn't support javascript.
A DNA Barcode-Based Aptasensor Enables Rapid Testing of Porcine Epidemic Diarrhea Viruses in Swine Saliva Using Electrochemical Readout.
Victorious, Amanda; Zhang, Zijie; Chang, Dingran; Maclachlan, Roderick; Pandey, Richa; Xia, Jianrun; Gu, Jimmy; Hoare, Todd; Soleymani, Leyla; Li, Yingfu.
  • Victorious A; School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario, L8S 4K1, Canada.
  • Zhang Z; Department of Biochemistry and Biomedical Sciences, McMaster University, Canada.
  • Chang D; Department of Biochemistry and Biomedical Sciences, McMaster University, Canada.
  • Maclachlan R; Department of Engineering Physics, McMaster University, Canada.
  • Pandey R; School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario, L8S 4K1, Canada.
  • Xia J; Department of Biochemistry and Biomedical Sciences, McMaster University, Canada.
  • Gu J; Department of Biochemistry and Biomedical Sciences, McMaster University, Canada.
  • Hoare T; School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario, L8S 4K1, Canada.
  • Soleymani L; Department of Chemical Engineering, McMaster University, Canada.
  • Li Y; School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario, L8S 4K1, Canada.
Angew Chem Int Ed Engl ; 61(31): e202204252, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: covidwho-1843851
ABSTRACT
Pen-side testing of farm animals for infectious diseases is critical for preventing transmission in herds and providing timely intervention. However, most existing pathogen tests have to be conducted in centralized labs with sample-to-result times of 2-4 days. Herein we introduce a test that uses a dual-electrode electrochemical chip (DEE-Chip) and a barcode-releasing electroactive aptamer for rapid on-farm detection of porcine epidemic diarrhea viruses (PEDv). The sensor exploits inter-electrode spacing reduction and active field mediated transport to accelerate barcode movement from electroactive aptamers to the detection electrode, thus expediting assay operation. The test yielded a clinically relevant limit-of-detection of 6 nM (0.37 µg mL-1 ) in saliva-spiked PEDv samples. Clinical evaluation of this biosensor with 12 porcine saliva samples demonstrated a diagnostic sensitivity of 83 % and specificity of 100 % with a concordance value of 92 % at an analysis time of one hour.
Asunto(s)
Palabras clave

Texto completo: Disponible Colección: Bases de datos internacionales Base de datos: MEDLINE Asunto principal: Enfermedades de los Porcinos / Infecciones por Coronavirus / Virus de la Diarrea Epidémica Porcina Tipo de estudio: Estudios diagnósticos / Estudio experimental / Estudio pronóstico Límite: Animales Idioma: Inglés Revista: Angew Chem Int Ed Engl Año: 2022 Tipo del documento: Artículo País de afiliación: Anie.202204252

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Colección: Bases de datos internacionales Base de datos: MEDLINE Asunto principal: Enfermedades de los Porcinos / Infecciones por Coronavirus / Virus de la Diarrea Epidémica Porcina Tipo de estudio: Estudios diagnósticos / Estudio experimental / Estudio pronóstico Límite: Animales Idioma: Inglés Revista: Angew Chem Int Ed Engl Año: 2022 Tipo del documento: Artículo País de afiliación: Anie.202204252