Conversion of positive-pressure cardiac catheterization and electrophysiology laboratories to a novel 2-zone negative-pressure system during COVID-19 pandemic.
Truesdell, Monica; Guttman, Paul; Clarke, Barbara; Wagner, Sheryl; Bloom, Jim; DuShane, Jeff; Richardson, Linda; VanderElzen, Kristen; Chetcuti, Stanley; Oral, Hakan.
  • Truesdell M; Cardiac Procedures Unit, Interventional Cardiology and Cardiac Arrhythmia Service, University of Michigan, Ann Arbor, Michigan.
  • Guttman P; Cardiac Procedures Unit, Interventional Cardiology and Cardiac Arrhythmia Service, University of Michigan, Ann Arbor, Michigan.
  • Clarke B; Cardiac Procedures Unit, Interventional Cardiology and Cardiac Arrhythmia Service, University of Michigan, Ann Arbor, Michigan.
  • Wagner S; Cardiac Procedures Unit, Interventional Cardiology and Cardiac Arrhythmia Service, University of Michigan, Ann Arbor, Michigan.
  • Bloom J; Cardiac Procedures Unit, Interventional Cardiology and Cardiac Arrhythmia Service, University of Michigan, Ann Arbor, Michigan.
  • DuShane J; Cardiac Procedures Unit, Interventional Cardiology and Cardiac Arrhythmia Service, University of Michigan, Ann Arbor, Michigan.
  • Richardson L; Cardiac Procedures Unit, Interventional Cardiology and Cardiac Arrhythmia Service, University of Michigan, Ann Arbor, Michigan.
  • VanderElzen K; Cardiac Procedures Unit, Interventional Cardiology and Cardiac Arrhythmia Service, University of Michigan, Ann Arbor, Michigan.
  • Chetcuti S; Cardiac Procedures Unit, Interventional Cardiology and Cardiac Arrhythmia Service, University of Michigan, Ann Arbor, Michigan.
  • Oral H; Cardiac Procedures Unit, Interventional Cardiology and Cardiac Arrhythmia Service, University of Michigan, Ann Arbor, Michigan.
J Cardiovasc Electrophysiol ; 31(8): 1901-1903, 2020 08.
Artículo en Inglés | MEDLINE | ID: covidwho-342782
ABSTRACT
During coronavirus disease-2019 (COVID-19) pandemic, there continues to be a need to utilize cardiac catheterization and electrophysiology laboratories for emergent and urgent procedures. Per infection prevention guidelines and hospital codes, catheterization and electrophysiology laboratories are usually built as positive-pressure ventilation rooms to minimize the infection risk. However, patients with highly transmissible airborne diseases such as COVID-19 are best caredfor in negative ventilation rooms to minimize the risk of transmission. From a mechanical and engineering perspective, positive-pressure ventilation rooms cannot be readily converted to negative-pressure ventilation rooms. In this report, we describe a novel, quick, readily implantable, and resource-friendly approach on how to secure air quality in catheterization and electrophysiology laboratories by converting a positive-pressure ventilation room to a two-zone negative ventilation system to minimize the risk of transmission.
Asunto(s)
Palabras clave

Texto completo: Disponible Colección: Bases de datos internacionales Base de datos: MEDLINE Asunto principal: Ventilación / Cateterismo Cardíaco / Control de Infecciones / COVID-19 Tipo de estudio: Estudio pronóstico Límite: Humanos Idioma: Inglés Revista: J Cardiovasc Electrophysiol Asunto de la revista: Angiología / Cardiología / Fisiología Año: 2020 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponible Colección: Bases de datos internacionales Base de datos: MEDLINE Asunto principal: Ventilación / Cateterismo Cardíaco / Control de Infecciones / COVID-19 Tipo de estudio: Estudio pronóstico Límite: Humanos Idioma: Inglés Revista: J Cardiovasc Electrophysiol Asunto de la revista: Angiología / Cardiología / Fisiología Año: 2020 Tipo del documento: Artículo