ABSTRACT
This protocol presents the Variant Nucleotide Guard (VaNGuard) assay, which is robust towards viral mutations and can be performed on purified RNA or directly on nasopharyngeal (NP) swab samples. The procedure typically comprises three parts, namely sample preparation, RT-LAMP reaction, and Cas12a-based detection via fluorescence or lateral flow assay. Sample preparation from NP swabs involves Proteinase K digestion followed by heat inactivation. Purified RNA or digested NP swab samples are then added as templates into RT-LAMP reactions and incubated at 65ºC for 22 minutes. Next, enAsCas12a and ssDNA-probes are added and the reactions are incubated at 60ºC for another 5 minutes. End-point fluorescence can be detected by a plate reader or a real-time PCR machine. Alternatively, a lateral flow strip can be inserted into each reaction tube for equipment-free read-out. The VaNGuard assay is a rapid and convenient point-of-care test for SARS-CoV-2 and is applicable to resource poor settings. 

Texte intégral: Disponible Collection: Preprints Base de données: PREPRINT-RESEARCHSQUARE langue: Anglais Année: 2021 Type de document: Preprint