Your browser doesn't support javascript.
Anti-PF4 testing for vaccine-induced immune thrombocytopenia and thrombosis and heparin induced thrombocytopenia: Results from a UK National External Quality Assessment Scheme exercise April 2021.
Reilly-Stitt, Christopher; Kitchen, Steve; Jennings, Ian; Horner, Kevin; Jones, Robert; Makris, Mike; Walker, Isobel D.
  • Reilly-Stitt C; UK NEQAS (Blood Coagulation), Sheffield, UK.
  • Kitchen S; UK NEQAS (Blood Coagulation), Sheffield, UK.
  • Jennings I; Sheffield Haemophilia and Thrombosis Centre, Royal Hallamshire Hospital, Sheffield, UK.
  • Horner K; UK NEQAS (Blood Coagulation), Sheffield, UK.
  • Jones R; Sheffield Haemophilia and Thrombosis Centre, Royal Hallamshire Hospital, Sheffield, UK.
  • Makris M; Sheffield Haemophilia and Thrombosis Centre, Royal Hallamshire Hospital, Sheffield, UK.
  • Walker ID; Sheffield Haemophilia and Thrombosis Centre, Royal Hallamshire Hospital, Sheffield, UK.
J Thromb Haemost ; 19(9): 2263-2267, 2021 09.
Artigo em Inglês | MEDLINE | ID: covidwho-1297836
ABSTRACT

BACKGROUND:

Vaccine-induced immune thrombocytopenia and thrombosis (VITT) following the administration of the AstraZeneca (AZ) ChAdOx1 nCOV-19 vaccine has recently been reported. The associated clinical and laboratory features have included thrombosis at unusual sites, thrombocytopenia, and raised D-dimers with positivity for IgG anti-platelet factor 4 (PF4) antibodies.

OBJECTIVES:

A UK National External Quality Control Assessment Scheme external quality control exercise was carried out by distributing liquid and lyophilized samples from a subject with VITT, a pool of samples from subjects with classical heparin-induced thrombocytopenia (HIT), and a non-VITT/non-HIT case to 85 centers performing HIT testing.

METHODS:

Participating centers employed their locally validated testing methods for HIT assays.

RESULTS:

The lyophilized and liquid samples were found to be commutable for the ELISA assays used in the detection of anti-PF4 antibodies. The Aeskulisa, Stago, Hyphen, and LIFECODES anti-PF4 ELISA assays successfully detected the VITT antibody, whereas the Acustar HIT, Werfen LIA, and the Stago STIC assays did not.

CONCLUSION:

It is important that clinical and laboratory teams are aware of the limitations of some anti-PF4 assays when using them to aid diagnosis of VITT syndrome.
Assuntos
Palavras-chave

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: MEDLINE Assunto principal: Trombocitopenia / Trombose / Vacinas / Púrpura Trombocitopênica Idiopática Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo prognóstico Tópicos: Vacinas Limite: Humanos País/Região como assunto: Europa Idioma: Inglês Revista: J Thromb Haemost Assunto da revista: Hematologia Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Jth.15423

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: MEDLINE Assunto principal: Trombocitopenia / Trombose / Vacinas / Púrpura Trombocitopênica Idiopática Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo prognóstico Tópicos: Vacinas Limite: Humanos País/Região como assunto: Europa Idioma: Inglês Revista: J Thromb Haemost Assunto da revista: Hematologia Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Jth.15423