Your browser doesn't support javascript.
Inactivation characteristics of a 280 nm Deep-UV irradiation dose on aerosolized SARS-CoV-2.
Takamure, Kotaro; Iwatani, Yasumasa; Amano, Hiroshi; Yagi, Tetsuya; Uchiyama, Tomomi.
  • Takamure K; Institute of Materials and Systems for Sustainability, Nagoya University, Nagoya 464-8601, Japan. Electronic address: takamure.kotaro.w3@f.mail.nagoya-u.ac.jp.
  • Iwatani Y; Clinical Research Center, National Hospital Organization Nagoya Medical Center, Nagoya 460-0001, Japan.
  • Amano H; Institute of Materials and Systems for Sustainability, Nagoya University, Nagoya 464-8601, Japan.
  • Yagi T; Department of Infectious Diseases, Nagoya University Hospital, Nagoya 466-0065, Japan.
  • Uchiyama T; Institute of Materials and Systems for Sustainability, Nagoya University, Nagoya 464-8601, Japan.
Environ Int ; 177: 108022, 2023 07.
Artigo em Inglês | MEDLINE | ID: covidwho-20231002
ABSTRACT
A non-filter virus inactivation unit was developed that can control the irradiation dose of aerosolized viruses by controlling the lighting pattern of a 280 nm deep-UV (DUV)-LED and the air flowrate. In this study, the inactivation properties of aerosolized SARS-CoV-2 were quantitatively evaluated by controlling the irradiation dose to the virus inside the inactivation unit. The RNA concentration of SARS-CoV-2 remained constant when the total irradiation dose of DUV irradiation to the virus exceeded 16.5 mJ/cm2. This observation suggests that RNA damage may occur in regions below the detection threshold of RT-qPCR assay. However, when the total irradiation dose was less than 16.5 mJ/cm2, the RNA concentration monotonically increased with a decreasing LED irradiation dose. However, the nucleocapsid protein concentration of SARS-CoV-2 was not predominantly dependent on the LED irradiation dose. The plaque assay showed that 99.16% of the virus was inactivated at 8.1 mJ/cm2 of irradiation, and no virus was detected at 12.2 mJ/cm2 of irradiation, resulting in a 99.89% virus inactivation rate. Thus, an irradiation dose of 23% of the maximal irradiation capacity of the virus inactivation unit can activate more than 99% of SARS-CoV-2. These findings are expected to enhance versatility in various applications. The downsizing achieved in our study renders the technology apt for installation in narrow spaces, while the enhanced flowrates establish its viability for implementation in larger facilities.
Assuntos
Palavras-chave

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: MEDLINE Assunto principal: Vírus / COVID-19 Tipo de estudo: Estudo experimental / Estudo observacional / Estudo prognóstico Limite: Humanos Idioma: Inglês Revista: Environ Int Ano de publicação: 2023 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: MEDLINE Assunto principal: Vírus / COVID-19 Tipo de estudo: Estudo experimental / Estudo observacional / Estudo prognóstico Limite: Humanos Idioma: Inglês Revista: Environ Int Ano de publicação: 2023 Tipo de documento: Artigo