Preprints publicados online permitem que os autores recebam feedback rápido, e toda a comunidade científica pode avaliar o trabalho independentemente e responder adequadamente. Estes comentários são publicados juntamente com os preprints para qualquer pessoa ler e servir como uma avaliação pós-publicação.
Performance of antigen lateral flow devices in the United Kingdom during the Alpha, Delta, and Omicron waves of the SARS-CoV-2 pandemic (preprint)
medrxiv; 2022.
Preprint
em Inglês
| medRxiv | ID: ppzbmed-10.1101.2022.11.29.22282899
ABSTRACT
Background Antigen lateral flow devices (LFDs) have been widely used to control SARS-CoV-2. Changes in LFD sensitivity and detection of infectious individuals during the pandemic with successive variants, vaccination, and changes in LFD use are incompletely understood. Methods Paired LFD and PCR tests were collected from asymptomatic and symptomatic participants, across multiple settings in the UK between 04-November-2020 and 21-March-2022. Multivariable logistic regression was used to analyse LFD sensitivity and specificity, adjusting for viral load, LFD manufacturer, setting, age, sex, assistance, symptoms, vaccination, and variant. National contact tracing data were used to estimate the proportion of transmitting index cases (with [≥]1 PCR/LFD-positive contact) potentially detectable by LFDs over time, accounting for viral load, variant, and symptom status. Findings 4131/75,382 (5.5%) participants were PCR-positive. Sensitivity vs. PCR was 63.2% (95%CI 61.7-64.6%) and specificity 99.71% (99.66-99.74%). Increased viral load was independently associated with being LFD-positive. There was no evidence LFD sensitivity differed between Delta vs. Alpha/pre-Alpha infections, but Omicron infections were more likely to be LFD positive. Sensitivity was higher in symptomatic participants, 68.7% (66.9-70.4%) than in asymptomatic participants, 52.8% (50.1-55.4%). 79.4% (68.6-81.3%) of index cases resulting in probable onward transmission with were estimated to have been detectable using LFDs, this proportion was relatively stable over time/variants, but lower in asymptomatic vs. symptomatic cases. Interpretation LFDs remained able to detect most SARS-CoV-2 infections throughout vaccine roll-out and different variants. LFDs can potentially detect most infections that transmit to others and reduce risks. However, performance is lower in asymptomatic compared to symptomatic individuals. Funding UK Government.
Texto completo:
Disponível
Coleções:
Preprints
Base de dados:
medRxiv
Assunto principal:
Síndrome Respiratória Aguda Grave
Idioma:
Inglês
Ano de publicação:
2022
Tipo de documento:
Preprint
Similares
MEDLINE
...
LILACS
LIS