Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Publication year range
1.
J Back Musculoskelet Rehabil ; 28(1): 93-100, 2015.
Article in English | MEDLINE | ID: mdl-25061028

ABSTRACT

BACKGROUND: To improve hamstring extensibility some methods have been analyzed and compared for determining their acute and chronic effectiveness. OBJECTIVE: To compare the immediate effect of electrical muscle elongation (EME) versus Kinesio tape (KT) in hamstring muscle extensibility. METHODS: One hundred and twenty adult amateur athletes with hamstring shortness (straight leg raise test angle <80◦) were randomly assigned to a group: group 1 (EME session of 4 KHz interferential current, bipolar technique and AMF = 100 Hz, n = 40), group 2 (KT, n = 40) or group 3 (control group, no intervention, n = 40). Hamstring extensibility was assessed before and after the intervention through the active knee extension test. Results: Significant improvements were found in both EME and KT groups whereas no changes were detected in the control group. However, no significant differences between both techniques were detected. The EME group showed large effect size (d = 0.843) while the KT group reached medium effect size (d = 0.431). CONCLUSIONS: Both electrical muscle elongation and Kinesio tape are effective techniques in the short-term in amateur athletes with decreased hamstring extensibility. The higher increase of hamstring extensibility, with a better clinical effect was achieved with the application of electrical muscle elongation. However, no significant differences were found when comparing the effectiveness of both techniques.


Subject(s)
Athletic Tape , Leg/physiology , Muscle, Skeletal/physiology , Range of Motion, Articular/physiology , Adult , Electric Stimulation , Female , Humans , Male , Treatment Outcome , Young Adult
2.
Fisioterapia (Madr., Ed. impr.) ; 34(3): 112-117, mayo-jun. 2012.
Article in Spanish | IBECS | ID: ibc-111231

ABSTRACT

Objetivo Conocer el efecto inmediato de la elongación muscular eléctrica por medio de corrientes interferenciales sobre la amplitud articular en sujetos con cortedad isquiotibial. Material y método Se realizó una valoración inicial (pretest) y final (postest) en donde la variable sometida a estudio fue la amplitud articular. Los test aplicados fueron el test de elevación de la pierna recta (EPR) y test de ángulo poplíteo (TAP). Se empleó una corriente interferencial bipolar con una modulación de la amplitud de la frecuencia de 100Hz y una frecuencia portadora de 4Khz.ResultadosSe obtuvieron mejoras estadísticamente significativas en la extensibilidad isquiosural tras aplicar elongación muscular eléctrica para ambos test angulares (p≤0,0001), siendo el tamaño efecto de R2=0,833 para TAP y de R2=0,752 para EPR. Conclusiones La aplicación de elongación muscular mediante corrientes interferenciales logra un aumento inmediato en la extensibilidad de la musculatura isquiosural tras ser medida con EPR y TAP(AU)


Objective To determine the immediate effect of electrical muscle elongation interferential currents through joint range of subjects with hamstring shortness. Material and method We performed an initial (pre-test) and final (post-test) assessment where the variable under study was the joint range. The tests applied were the straight leg raise test (SLR) and passive knee extension test (PKE). We used a bipolar interferential current with an amplitude modulation frequency of 100Hz and 4kHz carrier frequency. Results Statistically significant improvements were obtained in hamstring extensibility after applying electrical muscle elongation angle for both test (p ≤ 0.0001), with effect size for PKE of R2=0.833 and of R2=0.752 and for SLR. Conclusions The use of muscle elongation by interferential currents achieved an immediate increase in hamstring muscle extensibility after being measured by SLR and PKE (AU)


Subject(s)
Humans , Muscle Stretching Exercises/methods , Ischium/physiology , Tibia/physiology , Electric Stimulation/methods , Evaluation of Results of Therapeutic Interventions
3.
Fisioterapia (Madr., Ed. impr.) ; 33(6): 243-247, nov.-dic. 2011.
Article in Spanish | IBECS | ID: ibc-98622

ABSTRACT

Objetivo Establecer y validar un procedimiento de electroterapia con corrientes interferenciales en sujetos con dolor lumbar, así como evaluar la disminución del dolor lumbar inmediato con la aplicación de una corriente interferencial tetrapolar. Material y métodos Equipo de electroterapia Sonopuls 692® (Enraf Nonius). Estudio experimental, longitudinal y prospectivo sin aleatorización ni grupo control. Realizamos mediciones del dolor lumbar mediante la escala analógica visual (EVA) pre y post-intervención de la aplicación de la corriente interferencial, en 22 sujetos (35 y 65 años [51 años±9,11]), de ambos sexos (13 hombres y 9 mujeres).Resultados La disminución del dolor lumbar es estadísticamente significativa en la primera sesión y en la segunda sesión (para p<0,05). Observando una disminución en el valor medio de 4,136 en la primera sesión y 2,909 en la segunda sesión. El tamaño del efecto estadístico es grande (0,76).Conclusión El procedimiento electroterapéutico de corrientes interferenciales es eficaz y clínicamente significativo. La disminución del dolor lumbar con la aplicación de la corriente interferencial es más importante en la primera sesión que en la segunda (AU)


Objective To establish and validate an electrotherapy procedure using interferential currents (IFC) in patients with low back pain as well as to evaluate the immediate reduction of lumbar pain with the application of a tetrapolar interferential current. Material and methods Sonopuls 692® (Enraf Nonius). An experimental, longitudinal and prospective study without randomization or control group (N=22) was performed. Lumbar pain was measured using the Visual Analogue Scale (VAS) before and after the application of the interferential current in 22 subjects (35 y 65 years (51 years±9.11) of both genders (13 men, 9 women).Results The reduction in lumbar pain is statistically significant in the 1st and 2nd session (p<0.05), observing a reduction of the average value of 4.136 in the 1st session and 2.909 in the 2nd session. The size of the statistical effect is wide (0.76).Conclusions The electrotherapeutic procedure of interferential currents is effective and clinically significant. The reduction of lumbar pain with the application of interferential currents is more significant in 1st session than in the 2nd session (AU)


Subject(s)
Humans , Low Back Pain/therapy , /methods , Pilot Projects , Age and Sex Distribution
4.
Rev. iberoam. fisioter. kinesiol. (Ed. impr.) ; 9(1): 20-27, ene. 2006. tab, graf
Article in Es | IBECS | ID: ibc-050398

ABSTRACT

Presentamos un estudio de concordancia entre dos fisioterapeutas que realizan la medición de los niveles de percepción de una corriente TENS. El objetivo principal es comprobar que la diferencia entre las medidas obtenidas en la dosificación de la corriente TENS no se debe a la incidencia de los profesionales que efectúan las mediciones. Se trata de un diseño experimental de dos factores con medidas repetidas en un factor. La muestra la conforman 804 mediciones realizadas en 134 estudiantes de Fisioterapia. Los resultados obtenidos señalan una alta fiabilidad entre las medidas y la consistencia del procedimiento utilizado, demostrándose, mediante el ANOVA, la inexistencia de una influencia sistemática de los profesionales en su aplicación. Podemos concluir que dicho procedimiento constituye una herramienta útil para emplearse en los diversos protocolos de actuación profesional y en estudios de investigación con las corrientes TENS


We present a study of concordance between the measurements carry out by two Physiotherapists of the perception levels of a TENS current. The main objective is to check that the difference between the measurements obtained when administrating TENS, is not due to de incidence of the professionals who take them. It is an experimental design of two factors with repeated measures in one of them. The sample is formed by 804 measurements taken on 134 Physiotherapy students. The results point to a high reliability between the measurements and the method used, proving, through the ANOVA, the nonexistence of a sistematic influence of the professionals in its application. We can conclude this procedure is an useful tool to use in the several protocols of professionals actions and the investigation studies with TENS currents


Subject(s)
Humans , Bias , Reproducibility of Results , Transcutaneous Electric Nerve Stimulation/methods , Physical Therapy Modalities/methods , Clinical Protocols/standards , Analysis of Variance
5.
Fisioterapia (Madr., Ed. impr.) ; 24(4): 219-224, oct. 2002. tab
Article in Es | IBECS | ID: ibc-16097

ABSTRACT

En este trabajo se analizan los cambios producidos en la disciplina de electroterapia, hidroterapia y termoterapia, que es impartida en el primer curso de la diplomatura de Fisioterapia de Cádiz con motivo de la renovación de los planes de estudios. Asimismo se compara esta asignatura con las de igual contenido impartidas en el resto de escuelas andaluzas. También comprobamos la planificación docente específica de Fisioterapia de primer curso de las citadas escuelas con el fin de saber si existe docencia unificada, dado que ésta es la única forma de mejorar y completar la enseñanza, además de conseguir docencia de calidad (AU)


Subject(s)
Humans , Schools, Health Occupations/statistics & numerical data , Educational Measurement , Curriculum , Physical Therapy Specialty/education , Spain
SELECTION OF CITATIONS
SEARCH DETAIL
...