Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
Article in English | MEDLINE | ID: mdl-38631927

ABSTRACT

This narrative review aims to summarize available evidence on the IVF-associated outcomes after surgery for endometriosis. Only one retrospective study investigated if surgical treatment of superficial/peritoneal endometriosis may modify the outcomes of IVF; therefore, more data are needed to confirm the benefit of surgery for this type of disease for improving ART outcomes, and to be able to support it in routine practice. Solid evidence from several meta-analyses demonstrates that surgical treatment of endometriomas does not enhance the outcomes of IVF. In contrast, surgical treatment of ovarian endometriosis may lead to a reduction in ovarian reserve, especially in cases involving bilateral endometriomas or repeated surgical procedures. Some non-randomized studies have examined if surgical treatment on deep endometriosis may influence IVF outcomes. A systematic review with meta-analysis revealed that patients who underwent surgery before IVF exhibited significantly higher pregnancy rates per patient, pregnancy rates per cycle, and live birth rates per patient compared to those without prior surgery. However, the available data are insufficient to recommend surgical excision of deep endometriosis as the first-line treatment for asymptomatic patients to enhance IVF outcomes.


Subject(s)
Endometriosis , Fertilization in Vitro , Infertility, Female , Pregnancy Rate , Female , Humans , Pregnancy , Endometriosis/surgery , Infertility, Female/etiology , Infertility, Female/surgery , Live Birth , Ovarian Reserve , Treatment Outcome
2.
J Clin Med ; 13(1)2023 Dec 27.
Article in English | MEDLINE | ID: mdl-38202159

ABSTRACT

BACKGROUND: Infective endocarditis (IE) is a serious disease, and in many cases, surgery is necessary. Whether the type of prosthesis implanted for aortic valve replacement (AVR) for IE impacts patient survival is a matter of debate. The aim of the present study is to quantify differences in long-term survival and recurrence of endocarditis AVR for IE according to prosthesis type among patients aged 40 to 65 years. METHODS: This was an analysis of the INFECT-REGISTRY. Trends in proportion to the use of mechanical prostheses versus biological ones over time were tested by applying the sieve bootstrapped t-test. Confounders were adjusted using the optimal full-matching propensity score. The difference in overall survival was compared using the Cox model, whereas the differences in recurrence of endocarditis were evaluated using the Gray test. RESULTS: Overall, 4365 patients were diagnosed and operated on for IE from 2000 to 2021. Of these, 549, aged between 40 and 65 years, underwent AVR. A total of 268 (48.8%) received mechanical prostheses, and 281 (51.2%) received biological ones. A significant trend in the reduction of implantation of mechanical vs. biological prostheses was observed during the study period (p < 0.0001). Long-term survival was significantly higher among patients receiving a mechanical prosthesis than those receiving a biological prosthesis (hazard ratio [HR] 0.546, 95% CI: 0.322-0.926, p = 0.025). Mechanical prostheses were associated with significantly less recurrent endocarditis after AVR than biological prostheses (HR 0.268, 95%CI: 0.077-0.933, p = 0.039). CONCLUSIONS: The present analysis of the INFECT-REGISTRY shows increased survival and reduced recurrence of endocarditis after a mechanical aortic valve prosthesis implant for IE in middle-aged patients.

3.
Clin. infect. dis ; 73(11): 3750-e:3758, Dec. 2021. graf, tab
Article in English | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1353336

ABSTRACT

BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE (CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.


Subject(s)
Endocarditis , Transcatheter Aortic Valve Replacement
4.
G Ital Cardiol (Rome) ; 22(4): 327-331, 2021 Apr.
Article in Italian | MEDLINE | ID: mdl-33783453

ABSTRACT

The allocation of clinical and economic resources is an emerging issue in health management. A useful update necessarily depends on the evaluation of long-term outcomes of clinical and surgical resources that can permit emphasis on all amendable fields, improve quality of care, and reduce health costs. The PRIORITY (PRedictIng long term Outcomes afteR Isolated coronary arTery bypass surgerY) study represents the first innovative step toward the updating of health management in a selected field, surgery for coronary artery disease, which is one of the most prevalent diseases and requires allocation of high-cost resources, although information on long-term outcomes is limited. The aims of the PRIORITY study are the identification of preoperative risk factors for long-term outcomes and the development of clinical and administrative preoperative scores that can guide clinicians and the national health system to more appropriate actions for increasing quality of care and reducing costs.


Subject(s)
Coronary Artery Bypass , Coronary Artery Disease , Coronary Artery Disease/surgery , Humans , Risk Factors , Treatment Outcome
5.
Clin Infect Dis ; 73(11): e3750-e3758, 2021 12 06.
Article in English | MEDLINE | ID: mdl-33733675

ABSTRACT

BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE ( CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.


Subject(s)
Endocarditis, Bacterial , Endocarditis , Transcatheter Aortic Valve Replacement , Endocarditis/epidemiology , Endocarditis/etiology , Endocarditis/surgery , Endocarditis, Bacterial/epidemiology , Endocarditis, Bacterial/etiology , Endocarditis, Bacterial/surgery , Humans , Incidence , Postoperative Complications/epidemiology , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
6.
Am J Cardiol ; 138: 66-71, 2021 01 01.
Article in English | MEDLINE | ID: mdl-33065081

ABSTRACT

Permanent pacemaker implantation (PPI) represents a rare complication after cardiac surgery, with no uniform agreement on timing and no information on follow-up. A multicenter retrospective study was designed to assess pacemaker dependency (PMD) and long-term mortality after cardiac surgery procedures. Between 2004 and 2016, PPI-patients from 18 centers were followed. Time-to-event data were evaluated with semiparametric regression Cox models and semiparametric Fine and Gray model for competing risk framework. Of 859 (0.90%) PPI-patients, 30% were pacemaker independent (PMI) at 6 months. PMD showed higher mortality compared with PMI (10-year survival 80.1% ± 2.6% and 92.2% +2.4%, respectively, log-rank p-value < 0.001) with an unadjusted hazard ratio for death of 0.36 (95% CI 0.20 to 0.65, p< 0.001 favoring PMI) and an adjusted hazard ratio of 0.19 (95% CI 0.08 to 0.45, p< 0.001 with PMD as reference). Crude cumulative incidence function of restored PMI rhythm at follow-up at 6 months, 1 year and 12 years were 30.5% (95% CI 27.3% to 33.7%), 33.7% (95% CI 30.4% to 36.9%) and 37.2% (95% CI 33.8% to 40.6%) respectively. PMI was favored by preoperative sinus rhythm with normal conduction (SR) (HR 2.37, 95% CI 1.65 to 3.40, p< 0.001), whereas coronary artery bypass grafting and aortic valve replacement were independently associated with PMD (HR 0.63, 95% CI 0.45 to 0.88, p = 0.006 and HR 0.807, 95% CI 0.65 to 0.99, p = 0.047 respectively). Time-to-implantation was not associated with increased rate of PMI. Although 30% of PPI-patients are PMI after 6 months, PMD is associated with higher mortality at long term.


Subject(s)
Atrioventricular Block/epidemiology , Bradycardia/epidemiology , Cardiac Pacing, Artificial , Cardiac Surgical Procedures , Mortality , Pacemaker, Artificial , Postoperative Complications/epidemiology , Aged , Aged, 80 and over , Atrioventricular Block/therapy , Bradycardia/therapy , Coronary Artery Bypass , Female , Heart Valve Prosthesis Implantation , Humans , Male , Middle Aged , Postoperative Complications/therapy , Proportional Hazards Models , Retrospective Studies
8.
Circulation ; 142(15): 1497-1499, Oct. 2020. graf
Article in English | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1148174
9.
Circ Cardiovasc Interv ; 12(11): e007938, 2019 11.
Article in English | MEDLINE | ID: mdl-31694412

ABSTRACT

BACKGROUND: No data exist about the characteristics of infective endocarditis (IE) post-transcatheter aortic valve replacement (TAVR) according to transcatheter valve type. We aimed to determine the incidence, clinical characteristics, and outcomes of patients with IE post-TAVR treated with balloon-expandable valve (BEV) versus self-expanding valve (SEV) systems. METHODS: Data from the multicenter Infectious Endocarditis After TAVR International Registry was used to compare IE patients with BEV versus SEV. RESULTS: A total of 245 patients with IE post-TAVR were included (SEV, 47%; BEV, 53%). The timing between TAVR and IE was similar between groups (SEV, 5.5 [1.2-15] months versus BEV, 5.3 [1.7-11.4] months; P=0.89). Enterococcal IE was more frequent in the SEV group (36.5% versus 15.4%; P<0.01), and vegetation location differed according to valve type (stent frame, SEV, 18.6%; BEV, 6.9%; P=0.01; valve leaflet, SEV, 23.9%; BEV, 38.5%; P=0.01). BEV recipients had a higher rate of stroke/systemic embolism (20.0% versus 8.7%, adjusted OR: 2.46, 95% CI: 1.04-5.82, P=0.04). Surgical explant of the transcatheter valve (SEV, 8.7%; BEV, 13.8%; P=0.21), and in-hospital death at the time of IE episode (SEV, 35.6%; BEV, 37.7%; P=0.74) were similar between groups. After a mean follow-up of 13±12 months, 59.1% and 54.6% of the SEV and BEV recipients, respectively, had died (P=0.66). CONCLUSIONS: The characteristics of IE post-TAVR, including microorganism type, vegetation location, and embolic complications but not early or late mortality, differed according to valve type. These results may help to guide the diagnosis and management of IE and inform future research studies in the field.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Balloon Valvuloplasty , Endocarditis, Bacterial/epidemiology , Heart Valve Prosthesis , Prosthesis-Related Infections/epidemiology , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Clinical Decision-Making , Device Removal , Endocarditis, Bacterial/microbiology , Endocarditis, Bacterial/mortality , Endocarditis, Bacterial/surgery , Female , Humans , Incidence , Male , Patient Selection , Prosthesis Design , Prosthesis-Related Infections/microbiology , Prosthesis-Related Infections/mortality , Prosthesis-Related Infections/surgery , Registries , Reoperation , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
10.
Circ. cardiovasc. interv ; 12(11): 1-8, nov., 2019. ilus., graf., tab.
Article in English | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1049984

ABSTRACT

BACKGROUND: No data exist about the characteristics of infective endocarditis (IE) post-transcatheter aortic valve replacement (TAVR) according to transcatheter valve type. We aimed to determine the incidence, clinical characteristics, and outcomes of patients with IE post-TAVR treated with balloon-expandable valve (BEV) versus self-expanding valve (SEV) systems. METHODS: Data from the multicenter Infectious Endocarditis After TAVR International Registry was used to compare IE patients with BEV versus SEV. RESULTS: A total of 245 patients with IE post-TAVR were included (SEV, 47%; BEV, 53%). The timing between TAVR and IE was similar between groups (SEV, 5.5 [1.2-15] months versus BEV, 5.3 [1.7-11.4] months; P=0.89). Enterococcal IE was more frequent in the SEV group (36.5% versus 15.4%; P<0.01), and vegetation location differed according to valve type (stent frame, SEV, 18.6%; BEV, 6.9%; P=0.01; valve leaflet, SEV, 23.9%; BEV, 38.5%; P=0.01). BEV recipients had a higher rate of stroke/systemic embolism (20.0% versus 8.7%, adjusted OR: 2.46, 95% CI: 1.04-5.82, P=0.04). Surgical explant of the transcatheter valve (SEV, 8.7%; BEV, 13.8%; P=0.21), and in-hospital death at the time of IE episode (SEV, 35.6%; BEV, 37.7%; P=0.74) were similar between groups. After a mean follow-up of 13±12 months, 59.1% and 54.6% of the SEV and BEV recipients, respectively, had died (P=0.66). CONCLUSIONS: The characteristics of IE post-TAVR, including microorganism type, vegetation location, and embolic complications but not early or late mortality, differed according to valve type. These results may help to guide the diagnosis and management of IE and inform future research studies in the field. (AU)


Subject(s)
Registries , Incidence , Endocarditis , Transcatheter Aortic Valve Replacement
12.
Int J Cardiol ; 241: 97-102, 2017 Aug 15.
Article in English | MEDLINE | ID: mdl-28390740

ABSTRACT

BACKGROUND: The aim of this large retrospective study was to provide a logistic risk model along an additive score to predict early mortality after surgical treatment of patients with heart valve or prosthesis infective endocarditis (IE). METHODS: From 2000 to 2015, 2715 patients with native valve endocarditis (NVE) or prosthesis valve endocarditis (PVE) were operated on in 26 Italian Cardiac Surgery Centers. The relationship between early mortality and covariates was evaluated with logistic mixed effect models. Fixed effects are parameters associated with the entire population or with certain repeatable levels of experimental factors, while random effects are associated with individual experimental units (centers). RESULTS: Early mortality was 11.0% (298/2715); At mixed effect logistic regression the following variables were found associated with early mortality: age class, female gender, LVEF, preoperative shock, COPD, creatinine value above 2mg/dl, presence of abscess, number of treated valve/prosthesis (with respect to one treated valve/prosthesis) and the isolation of Staphylococcus aureus, Fungus spp., Pseudomonas Aeruginosa and other micro-organisms, while Streptococcus spp., Enterococcus spp. and other Staphylococci did not affect early mortality, as well as no micro-organisms isolation. LVEF was found linearly associated with outcomes while non-linear association between mortality and age was tested and the best model was found with a categorization into four classes (AUC=0.851). CONCLUSIONS: The following study provides a logistic risk model to predict early mortality in patients with heart valve or prosthesis infective endocarditis undergoing surgical treatment, called "The EndoSCORE".


Subject(s)
Cardiac Surgical Procedures/mortality , Endocarditis/diagnosis , Endocarditis/mortality , Heart Valve Prosthesis , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/mortality , Adult , Aged , Aged, 80 and over , Cardiac Surgical Procedures/trends , Female , Heart Valve Prosthesis/microbiology , Humans , Logistic Models , Male , Middle Aged , Predictive Value of Tests , Retrospective Studies , Treatment Outcome
13.
JAMA ; 316(10): 1083-92, 2016 Sep 13.
Article in English | MEDLINE | ID: mdl-27623462

ABSTRACT

IMPORTANCE: Limited data exist on clinical characteristics and outcomes of patients who had infective endocarditis after undergoing transcatheter aortic valve replacement (TAVR). OBJECTIVE: To determine the associated factors, clinical characteristics, and outcomes of patients who had infective endocarditis after TAVR. DESIGN, SETTING, AND PARTICIPANTS: The Infectious Endocarditis after TAVR International Registry included patients with definite infective endocarditis after TAVR from 47 centers from Europe, North America, and South America between June 2005 and October 2015. EXPOSURE: Transcatheter aortic valve replacement for incidence of infective endocarditis and infective endocarditis for in-hospital mortality. MAIN OUTCOMES AND MEASURES: Infective endocarditis and in-hospital mortality after infective endocarditis. RESULTS: A total of 250 cases of infective endocarditis occurred in 20 006 patients after TAVR (incidence, 1.1% per person-year; 95% CI, 1.1%-1.4%; median age, 80 years; 64% men). Median time from TAVR to infective endocarditis was 5.3 months (interquartile range [IQR], 1.5-13.4 months). The characteristics associated with higher risk of progressing to infective endocarditis after TAVR was younger age (78.9 years vs 81.8 years; hazard ratio [HR], 0.97 per year; 95% CI, 0.94-0.99), male sex (62.0% vs 49.7%; HR, 1.69; 95% CI, 1.13-2.52), diabetes mellitus (41.7% vs 30.0%; HR, 1.52; 95% CI, 1.02-2.29), and moderate to severe aortic regurgitation (22.4% vs 14.7%; HR, 2.05; 95% CI, 1.28-3.28). Health care-associated infective endocarditis was present in 52.8% (95% CI, 46.6%-59.0%) of patients. Enterococci species and Staphylococcus aureus were the most frequently isolated microorganisms (24.6%; 95% CI, 19.1%-30.1% and 23.3%; 95% CI, 17.9%-28.7%, respectively). The in-hospital mortality rate was 36% (95% CI, 30.0%-41.9%; 90 deaths; 160 survivors), and surgery was performed in 14.8% (95% CI, 10.4%-19.2%) of patients during the infective endocarditis episode. In-hospital mortality was associated with a higher logistic EuroSCORE (23.1% vs 18.6%; odds ratio [OR], 1.03 per 1% increase; 95% CI, 1.00-1.05), heart failure (59.3% vs 23.7%; OR, 3.36; 95% CI, 1.74-6.45), and acute kidney injury (67.4% vs 31.6%; OR, 2.70; 95% CI, 1.42-5.11). The 2-year mortality rate was 66.7% (95% CI, 59.0%-74.2%; 132 deaths; 115 survivors). CONCLUSIONS AND RELEVANCE: Among patients undergoing TAVR, younger age, male sex, history of diabetes mellitus, and moderate to severe residual aortic regurgitation were significantly associated with an increased risk of infective endocarditis. Patients who developed endocarditis had high rates of in-hospital mortality and 2-year mortality.


Subject(s)
Endocarditis, Bacterial/epidemiology , Endocarditis/etiology , Hospital Mortality/trends , Transcatheter Aortic Valve Replacement/adverse effects , Age Factors , Aged , Endocarditis, Bacterial/etiology , Female , Follow-Up Studies , Heart Failure , Humans , Male , Odds Ratio , Registries , Risk Factors , Sex Factors , Staphylococcal Infections/epidemiology , Staphylococcal Infections/etiology , Staphylococcus aureus , Treatment Outcome
14.
JAMA ; 316(10): 1083-1092, 2016.
Article in English | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1064090

ABSTRACT

IMPORTANCE: Limited data exist on clinical characteristics and outcomes of patients who had infective endocarditis after undergoing transcatheter aortic valve replacement (TAVR). OBJECTIVE: To determine the associated factors, clinical characteristics, and outcomes of patients who had infective endocarditis after TAVR. DESIGN, SETTING, AND PARTICIPANTS: The Infectious Endocarditis after TAVR International Registry included patients with definite infective endocarditis after TAVR from 47 centers from Europe, North America, and South America between June 2005 and October 2015. EXPOSURE: Transcatheter aortic valve replacement for incidence of infective endocarditis and infective endocarditis for in-hospital mortality. MAIN OUTCOMES AND MEASURES: Infective endocarditis and in-hospital mortality after infective endocarditis. RESULTS: A total of 250 cases of infective endocarditis occurred in 20 006 patients after TAVR (incidence, 1.1% per person-year; 95% CI, 1.1%-1.4%; median age, 80 years; 64% men). Median time from TAVR to infective endocarditis was 5.3 months (interquartile range [IQR], 1.5-13.4 months). The characteristics associated with higher risk of progressing to infective endocarditis after TAVR was younger age (78.9 years vs 81.8 years; hazard ratio [HR], 0.97 per year; 95% CI, 0.94-0.99), male sex (62.0% vs 49.7%; HR, 1.69; 95% CI, 1.13-2.52), diabetes mellitus (41.7% vs 30.0%; HR, 1.52; 95% CI, 1.02-2.29), and moderate to severe aortic regurgitation (22.4% vs 14.7%; HR, 2.05; 95% CI, 1.28-3.28). Health care-associated infective endocarditis was present in 52.8% (95% CI, 46.6%-59.0%) of patients...


Subject(s)
Endocarditis , Endocarditis, Bacterial , Transcatheter Aortic Valve Replacement
16.
Eur J Cardiothorac Surg ; 46(1): 44-8, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24401691

ABSTRACT

OBJECTIVES: Age, creatinine, ejection fraction (ACEF) score is a simplified algorithm for prediction of mortality after elective cardiac surgery. Although mainly conceived for elective cardiac surgery, no information is available on its performance in non-elective surgery and on comparison with the new EuroSCORE II. This study was undertaken to compare the performance of ACEF score and EuroSCORE II within classes of urgency. METHODS: Complete data on 13 871 consecutive patients who underwent major cardiac surgery in a 6-year period were retrieved from three prospective institutional databases. Discriminatory power was assessed using the c-index and h with Delong, bootstrap and Venkatraman methods. Calibration was evaluated with calibration curves and associated statistics. RESULTS: The in-hospital mortality rate was 2.5%. The discriminatory power of ACEF score within elective and non-elective surgery was similar (area under the curve (AUC) 0.71, 95% confidence interval (CI) 0.67-0.74 and AUC 0.68, 95% CI 0.62-0.73, respectively) but significantly lower than that of EuroSCORE II (AUC 0.80, 95% CI 0.77-0.83 for elective surgery; AUC 0.82, 95% CI 0.78-0.85 for non-elective surgery). The calibration patterns were different in the two subgroups, but the summary statistics underscored a miscalibration in both of them (U-statistic and Spiegelhalter Z-test P-values <0.05). Even the calibration of EuroSCORE II was insufficient, although it was demonstrated to be well calibrated in the first tertile of predicted risk. CONCLUSIONS: This study demonstrated that the performance of ACEF score in predicting in-hospital mortality in elective and non-elective cardiac surgery is comparable. Nonetheless, it is not as satisfactory as the new EuroSCORE II, as its discrimination is significantly lower and it is also miscalibrated.


Subject(s)
Cardiovascular Surgical Procedures/mortality , Hospital Mortality , Risk Assessment/methods , Age Factors , Aged , Creatinine/analysis , Data Interpretation, Statistical , Elective Surgical Procedures , Female , Humans , Male , ROC Curve , Risk Factors , Stroke Volume
18.
Artif Organs ; 36(10): 868-74, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22845744

ABSTRACT

The comparison of hemodilution at the end of surgery is of limited use as it represents only a snapshot of a dynamic phenomenon. This study was undertaken to compare the perioperative hemoglobin curves of isolated coronary artery bypass grafting performed with minimized extracorporeal circulation, traditional cardiopulmonary bypass, and off-pump technique. The propensity score method was used to select three groups of patients, homogenous regarding preoperative and operative data, who underwent isolated coronary artery bypass grafting. A generalized linear mixed model was used for estimating differences in perioperative hemoglobin trends among groups. The three groups were each composed of 50 patients with no differences in demographic data, preoperative risk profile, preoperative hemoglobin, or type of surgery. There was no significant difference in major postoperative complications. The pattern of the hemodilution curves was similar in patients operated with mini-circuit and off-pump technique (P > 005). Mini-circuit led to a 3.1 ± 11.9% hemoglobin reduction, which was similar to the off-pump group (1.6 ± 8.9%, P = 0.99 at ANOVA) and significantly different from the standard extracorporeal circuit group (16.0 ± 10.3%, P < 0.001 at ANOVA). The generalized linear mixed model determined that the standard circuit was the only independent predictor for increased hemodilution. Its effect on hemodilution was time-dependent and the slope of the hemoglobin curve was more pronounced between systemic heparinization and the end of surgery. Perioperative hemoglobin trends of patients who underwent myocardial revascularization with mini-circuit were similar to those of off-pump surgery and significantly less pronounced than those of standard extracorporeal circulation.


Subject(s)
Cardiopulmonary Bypass/methods , Coronary Artery Bypass, Off-Pump/methods , Hemoglobins/analysis , Aged , Extracorporeal Circulation/methods , Female , Hemodilution , Humans , Male , Middle Aged , Prospective Studies
20.
Int J Cardiol ; 144(2): 343-5, 2010 Oct 08.
Article in English | MEDLINE | ID: mdl-19344966

ABSTRACT

EuroSCORE algorithms were developed to predict perioperative mortality in cardiac surgery. This study was designed to evaluate the reliability of EuroSCORE algorithms and to analyze the predicting role of the scoring system's factors on patients that undergo isolate AVR. 339 patients underwent aortic valve replacement. Data collection was prospective and the logistic and additive EuroSCORE algorithms were calculated according to published guidelines. The observed-over-expected mortality ratio was 0.096. In the ROC curve analysis, the asymptotic significance was greater than 0.05. On multivariate analysis, only critical preoperative state remained significant independent predictor of in-hospital mortality (Odds Ratio 1.6, CI 1.2-2.1). These outcomes suggest that EuroSCORE models may fail in predicting hospital mortality in subsets of cardiac surgery patients and dedicated risk models for isolate aortic valvular surgery may be useful to provide more precise estimates of hospital mortality.


Subject(s)
Algorithms , Aortic Valve/surgery , Heart Valve Diseases/surgery , Heart Valve Prosthesis , Aged , Female , Humans , Male , Prognosis , Prospective Studies , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...