Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 47
Filter
1.
Circ. cardiovasc. interv ; 12(11): 1-8, nov., 2019. ilus., graf., tab.
Article in English | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1049984

ABSTRACT

BACKGROUND: No data exist about the characteristics of infective endocarditis (IE) post-transcatheter aortic valve replacement (TAVR) according to transcatheter valve type. We aimed to determine the incidence, clinical characteristics, and outcomes of patients with IE post-TAVR treated with balloon-expandable valve (BEV) versus self-expanding valve (SEV) systems. METHODS: Data from the multicenter Infectious Endocarditis After TAVR International Registry was used to compare IE patients with BEV versus SEV. RESULTS: A total of 245 patients with IE post-TAVR were included (SEV, 47%; BEV, 53%). The timing between TAVR and IE was similar between groups (SEV, 5.5 [1.2-15] months versus BEV, 5.3 [1.7-11.4] months; P=0.89). Enterococcal IE was more frequent in the SEV group (36.5% versus 15.4%; P<0.01), and vegetation location differed according to valve type (stent frame, SEV, 18.6%; BEV, 6.9%; P=0.01; valve leaflet, SEV, 23.9%; BEV, 38.5%; P=0.01). BEV recipients had a higher rate of stroke/systemic embolism (20.0% versus 8.7%, adjusted OR: 2.46, 95% CI: 1.04-5.82, P=0.04). Surgical explant of the transcatheter valve (SEV, 8.7%; BEV, 13.8%; P=0.21), and in-hospital death at the time of IE episode (SEV, 35.6%; BEV, 37.7%; P=0.74) were similar between groups. After a mean follow-up of 13±12 months, 59.1% and 54.6% of the SEV and BEV recipients, respectively, had died (P=0.66). CONCLUSIONS: The characteristics of IE post-TAVR, including microorganism type, vegetation location, and embolic complications but not early or late mortality, differed according to valve type. These results may help to guide the diagnosis and management of IE and inform future research studies in the field. (AU)


Subject(s)
Registries , Incidence , Endocarditis , Transcatheter Aortic Valve Replacement
2.
JACC Cardiovasc Interv ; 11(17): 1669-1679, 2018 09 10.
Article in English | MEDLINE | ID: mdl-30190058

ABSTRACT

OBJECTIVES: The authors aimed to determine the procedural learning curve and minimum annual institutional volumes associated with optimum clinical outcomes for transcatheter aortic valve replacement (TAVR). BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a complex procedure requiring significant training and experience for successful outcome. Despite increasing use of TAVR across institutions, limited information is available for its learning curve characteristics and minimum annual volumes required to optimize clinical outcomes. METHODS: The study collected data for patients at 16 centers participating in the international TAVR registry since initiation of the respective TAVR program. All cases were chronologically ordered into initial (1 to 75), early (76 to 150), intermediate (151 to 225), high (226 to 300), and very high (>300) experience operators for TAVR learning curve characterization. In addition, participating institutions were stratified by annual TAVR case volume into low-volume (<50), moderate-volume (50 to 100), and high-volume (>100) groups for comparative analysis. Procedural and 30-day clinical outcomes were collected and multivariate regression analysis performed for 30-day mortality and the early safety endpoint. RESULTS: A total of 3,403 patients comprised the study population. On multivariate analysis, all-cause mortality was significantly higher for initial (odds ratio [OR]: 3.83; 95% confidence interval [CI]: 1.93 to 7.60), early (OR: 2.41; 95% CI: 1.51 to 5.03), and intermediate (OR: 2.53; 95% CI: 1.19 to 5.40) experience groups compared with the very high experience operators. In addition, the early safety endpoint was significantly worse for all experience groups compared with the very high experience operators. Low annual volume (<50) TAVR institutions had significantly higher all-cause 30-day mortality (OR: 2.70; 95% CI: 1.44 to 5.07) and worse early safety endpoint (OR: 1.60; 95% CI: 1.17 to 2.17) compared with the moderate- and high-volume groups. There was no difference in patient outcomes between intermediate and high annual volume groups. CONCLUSIONS: TAVR procedures display important learning curve characteristics with both greater procedural safety and a lower mortality when performed by experienced operators. In addition, TAVR performed at low annual volume (<50 procedures) institutions is associated with decreased procedural safety and higher patient mortality. These findings have important implications for operator training and patient care at centers performing TAVR.


Subject(s)
Clinical Competence/standards , Hospitals, High-Volume/standards , Hospitals, Low-Volume/standards , Learning Curve , Outcome and Process Assessment, Health Care/standards , Surgeons/standards , Transcatheter Aortic Valve Replacement/standards , Aged , Aged, 80 and over , Female , Humans , Male , Patient Safety/standards , Postoperative Complications/epidemiology , Registries , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , Workload/standards
3.
JACC cardiovasc. interv ; 11(17): 1669-1679, Sept. 2018. graf, tab
Article in English | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1247793

ABSTRACT

OBJECTIVES: The authors aimed to determine the procedural learning curve and minimum annual institutional volumes associated with optimum clinical outcomes for transcatheter aortic valve replacement (TAVR).BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a complex procedure requiring significant training and experience for successful outcome. Despite increasing use of TAVR across institutions, limited information is available for its learning curve characteristics and minimum annual volumes required to optimize clinical outcomes. METHODS: The study collected data for patients at 16 centers participating in the international TAVR registry since initiation of the respective TAVR program. All cases were chronologically ordered into initial (1 to 75), early (76 to 150), intermediate (151 to 225), high (226 to 300), and very high (>300) experience operators for TAVR learning curve characterization. In addition, participating institutions were stratified by annual TAVR case volume into low-volume (<50), moderate-volume (50 to 100), and high-volume (>100) groups for comparative analysis. Procedural and 30-day clinical outcomes were collected and multivariate regression analysis performed for 30-day mortality and the early safety endpoint. RESULTS: A total of 3,403 patients comprised the study population. On multivariate analysis, all-cause mortality was significantly higher for initial (odds ratio [OR]: 3.83; 95% confidence interval [CI]: 1.93 to 7.60), early (OR: 2.41; 95%CI: 1.51 to 5.03), and intermediate (OR: 2.53; 95% CI: 1.19 to 5.40) experience groups compared with the very high experience operators. In addition, the early safety endpoint was significantly worse for all experience groups compared with the very high experience operators. Low annual volume (<50) TAVR institutions had significantly higher all-cause30-day mortality (OR: 2.70; 95% CI: 1.44 to 5.07) and worse early safety endpoint (OR: 1.60; 95% CI: 1.17 to 2.17) compared with the moderate- and high-volume groups. There was no difference in patient outcomes between intermediate and high annual volume groups. CONCLUSIONS: TAVR procedures display important learning curve characteristics with both greater procedural safety and a lower mortality when performed by experienced operators. In addition, TAVR performed at low annual volume (<50 procedures) institutions is associated with decreased procedural safety and higher patient mortality. These findings have important implications for operator training and patient care at centers performing TAVR.


Subject(s)
Humans , Female , Aged, 80 and over , Learning Curve , Transcatheter Aortic Valve Replacement/adverse effects
4.
Arq. bras. cardiol ; 109(6): 550-559, Dec. 2017. tab, graf
Article in English | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-887985

ABSTRACT

Abstract Background: Transcatheter aortic valve implantation (TAVI) is a well-established procedure; however, atrioventricular block requiring permanent pacemaker implantation (PPI) is a common complication. Objectives: To determine the incidence, predictors and clinical outcomes of PPI after TAVI, focusing on how PPI affects left ventricular ejection fraction (LVEF) after TAVI. Methods: The Brazilian Multicenter TAVI Registry included 819 patients submitted to TAVI due to severe aortic stenosis from 22 centers from January/2008 to January/2015. After exclusions, the predictors of PPI were assessed in 670 patients by use of multivariate regression. Analysis of the ROC curve was used to measure the ability of the predictors; p < 0.05 was the significance level adopted. Results: Within 30 days from TAVI, 135 patients (20.1%) required PPI. Those patients were older (82.5 vs. 81.1 years; p = 0.047) and mainly of the male sex (59.3% vs 45%; p = 0.003). Hospital length of stay was longer in patients submitted to PPI (mean = 15.7 ± 25.7 vs. 11.8 ± 22.9 days; p < 0.001), but PPI affected neither all-cause death (26.7% vs. 25.6%; p = 0.80) nor cardiovascular death (14.1% vs. 14.8%; p = 0.84). By use of multivariate analysis, the previous presence of right bundle-branch block (RBBB) (OR, 6.19; 3.56-10.75; p ≤ 0.001), the use of CoreValve® prosthesis (OR, 3.16; 1.74-5.72; p ≤ 0.001) and baseline transaortic gradient > 50 mm Hg (OR, 1.86; 1.08-3.2; p = 0.025) were predictors of PPI. The estimated risk of PPI ranged from 4%, when none of those predictors was present, to 63%, in the presence of all of them. The model showed good ability to predict the need for PPI: 0.69 (95%CI: 0.64 - 0.74) in the ROC curve. The substudy of 287 echocardiograms during the 1-year follow-up showed worse LVEF course in patients submitted to PPI (p = 0.01). Conclusion: BRD prévio, gradiente aórtico médio > 50 mmHg e CoreValve® são preditores independentes de implante de MPD pós-TAVI. Ocorreu implante de MPD em aproximadamente 20% dos casos de TAVI, o que prolongou a internação hospitalar, mas não afetou a mortalidade. O implante de MPD afetou negativamente a FEVE pós-TAVI.


Resumo Fundamento: O implante valvar aórtico transcateter (TAVI) está bem estabelecido, porém, o bloqueio atrioventricular, com necessidade de marca-passo definitivo (MPD), é complicação frequente. Objetivo: Determinar a incidência, preditores e desfechos clínicos de implante de MPD após TAVI, focando em como a evolução da fração de ejeção do ventrículo esquerdo (FEVE), após o TAVI, é afetada pelo MPD. Métodos: No registro brasileiro foram incluídos 819 pacientes submetidos a TAVI por estenose aórtica severa em 22 centros entre janeiro/2008 e janeiro/2015. Após exclusões, os preditores de implante de MPD foram avaliados em 670 pacientes por regressão multivariada. Análise da curva ROC foi utilizada para medir a habilidade dos preditores; p < 0,05 foi considerado significativo. Resultados: Aos 30 dias, 135 pacientes (20,1%) necessitaram de MPD. Tais pacientes eram mais velhos (82,5 vs. 81,1 anos; p = 0,047) e predominantemente homens (59,3% vs 45%; p = 0,003). A permanência hospitalar foi maior no Grupo MPD (média= 15,7 ± 25,7 vs. 11,8 ± 22,9 dias; p < 0,001), mas o implante não afetou morte por qualquer causa (26,7% vs. 25,6%; p = 0,80) nem morte cardiovascular (14,1% vs. 14,8%; p = 0,84). Por análise multivariada, a presença prévia de bloqueio de ramo direito (BRD) (OR, 6,19; 3,56-10,75; p ≤ 0,001), o uso da prótese CoreValve® (OR, 3,16; 1,74-5,72; p ≤ 0,001) e gradiente transaórtico basal > 50 mmHg (OR, 1,86; 1,08-3,2; p= 0,025) foram preditores de implante de MPD. O risco estimado de implante de MPD foi 4%, quando nenhum dos fatores de risco estava presente, e 63% na presença de todos. O modelo mostrou boa habilidade de prever a necessidade de MPD: 0,69 (IC95%: 0,64 - 0,74) na curva ROC. Subestudo de 287 ecocardiogramas durante o seguimento de 1 ano mostrou pior evolução da FEVE no Grupo MPD (p = 0,01). Conclusão: Em crianças de 6 a 11 anos, circunferência da cintura aumentada está associada à PA elevada, mesmo quando o IMC é normal. (Arq Bras Cardiol. 2017; [online].ahead print, PP.0-0)


Subject(s)
Humans , Male , Female , Aged, 80 and over , Aortic Valve/surgery , Pacemaker, Artificial/adverse effects , Bundle-Branch Block/surgery , Heart Valve Prosthesis/adverse effects , Cardiac Pacing, Artificial/methods , Heart Valve Prosthesis Implantation/adverse effects , Atrioventricular Block/surgery , Aortic Valve Stenosis/surgery , Postoperative Complications , Brazil , Risk Factors , Electrocardiography , Atrioventricular Block/physiopathology
5.
Arq Bras Cardiol ; 109(6): 550-559, 2017 Dec.
Article in English, Portuguese | MEDLINE | ID: mdl-29185614

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a well-established procedure; however, atrioventricular block requiring permanent pacemaker implantation (PPI) is a common complication. OBJECTIVES: To determine the incidence, predictors and clinical outcomes of PPI after TAVI, focusing on how PPI affects left ventricular ejection fraction (LVEF) after TAVI. METHODS: The Brazilian Multicenter TAVI Registry included 819 patients submitted to TAVI due to severe aortic stenosis from 22 centers from January/2008 to January/2015. After exclusions, the predictors of PPI were assessed in 670 patients by use of multivariate regression. Analysis of the ROC curve was used to measure the ability of the predictors; p < 0.05 was the significance level adopted. RESULTS: Within 30 days from TAVI, 135 patients (20.1%) required PPI. Those patients were older (82.5 vs. 81.1 years; p = 0.047) and mainly of the male sex (59.3% vs 45%; p = 0.003). Hospital length of stay was longer in patients submitted to PPI (mean = 15.7 ± 25.7 vs. 11.8 ± 22.9 days; p < 0.001), but PPI affected neither all-cause death (26.7% vs. 25.6%; p = 0.80) nor cardiovascular death (14.1% vs. 14.8%; p = 0.84). By use of multivariate analysis, the previous presence of right bundle-branch block (RBBB) (OR, 6.19; 3.56-10.75; p ≤ 0.001), the use of CoreValve® prosthesis (OR, 3.16; 1.74-5.72; p ≤ 0.001) and baseline transaortic gradient > 50 mm Hg (OR, 1.86; 1.08-3.2; p = 0.025) were predictors of PPI. The estimated risk of PPI ranged from 4%, when none of those predictors was present, to 63%, in the presence of all of them. The model showed good ability to predict the need for PPI: 0.69 (95%CI: 0.64 - 0.74) in the ROC curve. The substudy of 287 echocardiograms during the 1-year follow-up showed worse LVEF course in patients submitted to PPI (p = 0.01). CONCLUSION: BRD prévio, gradiente aórtico médio > 50 mmHg e CoreValve® são preditores independentes de implante de MPD pós-TAVI. Ocorreu implante de MPD em aproximadamente 20% dos casos de TAVI, o que prolongou a internação hospitalar, mas não afetou a mortalidade. O implante de MPD afetou negativamente a FEVE pós-TAVI.


Subject(s)
Aortic Valve/surgery , Atrioventricular Block/surgery , Bundle-Branch Block/surgery , Cardiac Pacing, Artificial/methods , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis/adverse effects , Pacemaker, Artificial/adverse effects , Aged, 80 and over , Aortic Valve Stenosis/surgery , Atrioventricular Block/physiopathology , Brazil , Electrocardiography , Female , Humans , Male , Postoperative Complications , Risk Factors
6.
J Phys Act Health ; 13(11): 1174-1182, 2016 11.
Article in English | MEDLINE | ID: mdl-27633621

ABSTRACT

BACKGROUND: Promoting physical activity (PA) in low- and middle-income countries is an important public health topic as well as a challenge for practice. This study aimed to assess the effect of a school-based intervention on different PA-related variables among students. METHODS: This cluster-randomized-controlled trial included 548 students in the intervention group and 537 in the control group (11-18 years-old) from 6 schools in neighborhoods with low Human Development Index (0.170-0.491) in Fortaleza, Brazil. The intervention included strategies focused on training teachers, opportunities for PA in the school environment and health education. Variables measured at baseline and again at the 4-months follow-up included the weekly time in different types of moderate-to-vigorous PA (MVPA), preference for PA during leisure-time, PA behavioral change stage and active commuting to school. Generalized linear models and binary logistic regressions were used. RESULTS: An intervention effect was found by increasing the weekly time in MVPA (effect size = 0.17), popular games (effect size = 0.35), and the amount of PA per week (effect size = 0.27) among students (all P < .05). CONCLUSIONS: The intervention was effective in promoting improvements in some PA outcomes, but the changes were not sufficient to increase the proportion of those meeting PA recommendations.


Subject(s)
Adolescent Behavior , Exercise , Poverty , Adolescent , Adolescent Health , Child , Child Health , Female , Humans , Male , School Health Services , Schools , Students , Treatment Outcome
7.
JAMA ; 316(10): 1083-92, 2016 Sep 13.
Article in English | MEDLINE | ID: mdl-27623462

ABSTRACT

IMPORTANCE: Limited data exist on clinical characteristics and outcomes of patients who had infective endocarditis after undergoing transcatheter aortic valve replacement (TAVR). OBJECTIVE: To determine the associated factors, clinical characteristics, and outcomes of patients who had infective endocarditis after TAVR. DESIGN, SETTING, AND PARTICIPANTS: The Infectious Endocarditis after TAVR International Registry included patients with definite infective endocarditis after TAVR from 47 centers from Europe, North America, and South America between June 2005 and October 2015. EXPOSURE: Transcatheter aortic valve replacement for incidence of infective endocarditis and infective endocarditis for in-hospital mortality. MAIN OUTCOMES AND MEASURES: Infective endocarditis and in-hospital mortality after infective endocarditis. RESULTS: A total of 250 cases of infective endocarditis occurred in 20 006 patients after TAVR (incidence, 1.1% per person-year; 95% CI, 1.1%-1.4%; median age, 80 years; 64% men). Median time from TAVR to infective endocarditis was 5.3 months (interquartile range [IQR], 1.5-13.4 months). The characteristics associated with higher risk of progressing to infective endocarditis after TAVR was younger age (78.9 years vs 81.8 years; hazard ratio [HR], 0.97 per year; 95% CI, 0.94-0.99), male sex (62.0% vs 49.7%; HR, 1.69; 95% CI, 1.13-2.52), diabetes mellitus (41.7% vs 30.0%; HR, 1.52; 95% CI, 1.02-2.29), and moderate to severe aortic regurgitation (22.4% vs 14.7%; HR, 2.05; 95% CI, 1.28-3.28). Health care-associated infective endocarditis was present in 52.8% (95% CI, 46.6%-59.0%) of patients. Enterococci species and Staphylococcus aureus were the most frequently isolated microorganisms (24.6%; 95% CI, 19.1%-30.1% and 23.3%; 95% CI, 17.9%-28.7%, respectively). The in-hospital mortality rate was 36% (95% CI, 30.0%-41.9%; 90 deaths; 160 survivors), and surgery was performed in 14.8% (95% CI, 10.4%-19.2%) of patients during the infective endocarditis episode. In-hospital mortality was associated with a higher logistic EuroSCORE (23.1% vs 18.6%; odds ratio [OR], 1.03 per 1% increase; 95% CI, 1.00-1.05), heart failure (59.3% vs 23.7%; OR, 3.36; 95% CI, 1.74-6.45), and acute kidney injury (67.4% vs 31.6%; OR, 2.70; 95% CI, 1.42-5.11). The 2-year mortality rate was 66.7% (95% CI, 59.0%-74.2%; 132 deaths; 115 survivors). CONCLUSIONS AND RELEVANCE: Among patients undergoing TAVR, younger age, male sex, history of diabetes mellitus, and moderate to severe residual aortic regurgitation were significantly associated with an increased risk of infective endocarditis. Patients who developed endocarditis had high rates of in-hospital mortality and 2-year mortality.


Subject(s)
Endocarditis, Bacterial/epidemiology , Endocarditis/etiology , Hospital Mortality/trends , Transcatheter Aortic Valve Replacement/adverse effects , Age Factors , Aged , Endocarditis, Bacterial/etiology , Female , Follow-Up Studies , Heart Failure , Humans , Male , Odds Ratio , Registries , Risk Factors , Sex Factors , Staphylococcal Infections/epidemiology , Staphylococcal Infections/etiology , Staphylococcus aureus , Treatment Outcome
8.
JAMA ; 316(10): 1083-1092, 2016.
Article in English | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1064090

ABSTRACT

IMPORTANCE: Limited data exist on clinical characteristics and outcomes of patients who had infective endocarditis after undergoing transcatheter aortic valve replacement (TAVR). OBJECTIVE: To determine the associated factors, clinical characteristics, and outcomes of patients who had infective endocarditis after TAVR. DESIGN, SETTING, AND PARTICIPANTS: The Infectious Endocarditis after TAVR International Registry included patients with definite infective endocarditis after TAVR from 47 centers from Europe, North America, and South America between June 2005 and October 2015. EXPOSURE: Transcatheter aortic valve replacement for incidence of infective endocarditis and infective endocarditis for in-hospital mortality. MAIN OUTCOMES AND MEASURES: Infective endocarditis and in-hospital mortality after infective endocarditis. RESULTS: A total of 250 cases of infective endocarditis occurred in 20 006 patients after TAVR (incidence, 1.1% per person-year; 95% CI, 1.1%-1.4%; median age, 80 years; 64% men). Median time from TAVR to infective endocarditis was 5.3 months (interquartile range [IQR], 1.5-13.4 months). The characteristics associated with higher risk of progressing to infective endocarditis after TAVR was younger age (78.9 years vs 81.8 years; hazard ratio [HR], 0.97 per year; 95% CI, 0.94-0.99), male sex (62.0% vs 49.7%; HR, 1.69; 95% CI, 1.13-2.52), diabetes mellitus (41.7% vs 30.0%; HR, 1.52; 95% CI, 1.02-2.29), and moderate to severe aortic regurgitation (22.4% vs 14.7%; HR, 2.05; 95% CI, 1.28-3.28). Health care-associated infective endocarditis was present in 52.8% (95% CI, 46.6%-59.0%) of patients...


Subject(s)
Endocarditis , Endocarditis, Bacterial , Transcatheter Aortic Valve Replacement
9.
Rev. bras. cardiol. invasiva ; 22(4): 315-319, Oct-Dec/2015. tab, graf
Article in Portuguese | LILACS, Sec. Est. Saúde SP | ID: lil-744565

ABSTRACT

Introdução: Polímeros biodegradáveis foram desenvolvidos para reduzir a reação de hipersensibilidade associada aos polímeros duráveis dos stents farmacológicos de primeira geração, mantendo sua eficácia antiproliferativa e aumentado sua segurança. Avaliamos os resultados angiográficos de 9 meses e os resultados clínicos de longo prazo dos stents farmacológicos com polímeros biodegradáveis em pacientes com alto risco de reestenose. Métodos: Pacientes com diâmetro de referência ≤ 2,5 mm, extensão da lesão ≥ 15 mm, diabetes, ou uma combinação dessas características foram selecionados da população do estudo PAINT. Esses pacientes foram previamente randomizados e alocados para intervenção coronária percutânea recebendo os stents farmacológicos com polímeros biodegradáveis com sirolimus ou com paclitaxel ou stents metálicos, na razão 2:2:1. Resultados: Cento e setenta e oito pacientes foram tratados com stents farmacológicos com polímeros biodegradáveis (n = 142) ou stents metálicos (n = 36). No acompanhamento angiográfico de 9 meses, os primeiros mostraram menor perda tardia (0,40 ± 0,42 mm vs. 0,90 ± 0,47 mm; p < 0,01) e reestenose binária (7,4% vs. 25%; p < 0,01). No acompanhamento clínico de 5 anos, o grupo com stents farmacológicos com polímeros biodegradáveis mostrou menores taxas do desfecho combinado de morte cardíaca, infarto do miocárdio e revascularização do vaso-alvo (16,2% vs. 38,0%; p = 0,03), principalmente devido à redução da revascularização do vaso-alvo (9,9% vs. 36,1%; p < 0,01). Morte total, morte cardíaca e infarto do miocárdio não foram diferentes entre os grupos. A trombose do stent, provável ou definitiva, ocorreu em 2,8% vs. 0% (p = 0,30). Conclusões: Os stents farmacológicos com polímeros biodegradáveis eluidores de paclitaxel ou sirolimus foram eficazes na redução de reestenose angiográfica aos 9 meses e na necessidade de reintervenção por reestenose clínica em 5 anos, sem aumentar o risco de...


Background: Biodegradable polymers were developed to reduce the hypersensitivity reaction associated to durable polymers found with the first generation drug-eluting stents, while maintaining antiproliferative efficacy and increasing safety. This study evaluated the 9-month angiographic follow-up and long-term clinical outcomes of biodegradable polymer-coated drug-eluting stents compared with identical platform metallic stents in patients with high-risk for restenosis. Methods: Patients with a reference diameter ≤ 2.5 mm, lesion length ≥ 15 mm, diabetes, or a combination of these characteristics were selected from the population of the PAINT trial. These patients were previously randomized and allocated for percutaneous coronary intervention with either a sirolimus-eluting biodegradable polymer-coated stent, a paclitaxel-eluting biodegradable polymer-coated stent, or an identical metallic platform stent, at a ratio of 2:2:1. Results: One hundred and seventy-eight patients were treated with biodegradable polymer-coated drug-eluting stents (n = 142) or bare metal stents (n = 36). At the 9-month angiographic follow-up, biodegradable polymercoated drug-eluting stents had lower rates of late loss (0.40 ± 0.42 mm vs. 0.90 ± 0.47 mm; p < 0.01) and binary restenosis (7.4% vs. 25%; p <0.01). In the 5-year clinical follow-up, the group with biodegradable polymer-coated drug-eluting stents had lower rates of the composite endpoint of cardiac death, myocardial infarction, and target vessel revascularization (16.2% vs. 38.0%; p = 0.03), especially due to the reduction of target vessel revascularization (9.9% vs. 36.1%; (p 0.01). Total death, cardiac death and myocardial infarction were not different among groups. 0% (p = 0.30). Conclusions: Paclitaxel or sirolimus-eluting biodegradable polymer-coated stents were effective in reducing angiographic restenosis at 9 months and the need of reintervention for clinical restenosis in 5...


Subject(s)
Humans , Male , Female , Middle Aged , Coronary Angiography/methods , Polymers/therapeutic use , Coronary Restenosis/therapy , Stents , Drug-Eluting Stents , Coronary Thrombosis/therapy , Data Interpretation, Statistical , Risk Assessment/methods , Paclitaxel/therapeutic use , Treatment Outcome , Sirolimus/therapeutic use , Coronary Vessels/surgery
10.
Braz. J. Psychiatry (São Paulo, 1999, Impr.) ; 36(1): 76-88, Jan-Mar. 2014. tab, graf
Article in English | LILACS | ID: lil-702630

ABSTRACT

Objective: To review information regarding the association of physical activity (PA) with quality of life (QoL) in the elderly and to identify the study designs and measurement instruments most commonly used in its assessment, in the period 2000-2012. Methods: Relevant articles were identified by a search of four electronic databases and cross-reference lists and by contact with the authors of the included manuscripts. Original studies on the association between PA and QoL in individuals aged 60 years or older were examined. The quality of studies as well as the direction and the consistency of the association between PA and QoL were evaluated. Results: A total of 10,019 articles were identified as potentially relevant, but only 42 (0.42%) met the inclusion criteria and were retrieved and examined. Most studies demonstrated a positive association between PA and QoL in the elderly. PA had a consistent association with the following QoL domains: functional capacity; general QoL; autonomy; past, present and future activities; death and dying; intimacy; mental health; vitality; and psychological. Conclusion: PA was positively and consistently associated with some QoL domains among older individuals, supporting the notion that promoting PA in the elderly may have an impact beyond physical health. However, the associations between PA and other QoL domains were moderate to inconsistent and require further investigation. .


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Exercise/physiology , Motor Activity/physiology , Quality of Life/psychology , Exercise/psychology , Surveys and Questionnaires , Social Environment , Time Factors
11.
J Public Health (Oxf) ; 36(4): 608-14, 2014 Dec.
Article in English | MEDLINE | ID: mdl-24504146

ABSTRACT

BACKGROUND: Economic and technological improvements can help increase screen time use among adolescents, but evidence in developing countries is scarce. The aim of this study was to examine changes in TV watching and computer/video game use patterns on week and weekend days after a decade (2001 and 2011), among students in Santa Catarina, southern Brazil. METHODS: A comparative analysis of two cross-sectional surveys that included 5 028 and 6 529 students in 2001 and 2011, respectively, aged 15-19 years. The screen time use indicators were self-reported. 95% Confidence intervals were used to compare the prevalence rates. All analyses were separated by gender. RESULTS: After a decade, there was a significant increase in computer/video game use. Inversely, a significant reduction in TV watching was observed, with a similar magnitude to the change in computer/video game use. The worst trends were identified on weekend days. CONCLUSIONS: The decrease in TV watching after a decade appears to be compensated by the increase in computer/video game use, both in boys and girls. Interventions are needed to reduce the negative impact of technological improvements in the lifestyles of young people, especially on weekend days.


Subject(s)
Adolescent Behavior , Computer Terminals/statistics & numerical data , Television/statistics & numerical data , Video Games/statistics & numerical data , Adolescent , Brazil , Cross-Sectional Studies , Developing Countries , Female , Humans , Male , Prevalence , Rest , Sex Distribution , Students , Surveys and Questionnaires , Television/trends , Young Adult
12.
Braz J Psychiatry ; 36(1): 76-88, 2014.
Article in English | MEDLINE | ID: mdl-24554274

ABSTRACT

OBJECTIVE: To review information regarding the association of physical activity (PA) with quality of life (QoL) in the elderly and to identify the study designs and measurement instruments most commonly used in its assessment, in the period 2000-2012. METHODS: Relevant articles were identified by a search of four electronic databases and cross-reference lists and by contact with the authors of the included manuscripts. Original studies on the association between PA and QoL in individuals aged 60 years or older were examined. The quality of studies as well as the direction and the consistency of the association between PA and QoL were evaluated. RESULTS: A total of 10,019 articles were identified as potentially relevant, but only 42 (0.42%) met the inclusion criteria and were retrieved and examined. Most studies demonstrated a positive association between PA and QoL in the elderly. PA had a consistent association with the following QoL domains: functional capacity; general QoL; autonomy; past, present and future activities; death and dying; intimacy; mental health; vitality; and psychological. CONCLUSION: PA was positively and consistently associated with some QoL domains among older individuals, supporting the notion that promoting PA in the elderly may have an impact beyond physical health. However, the associations between PA and other QoL domains were moderate to inconsistent and require further investigation.


Subject(s)
Exercise/physiology , Motor Activity/physiology , Quality of Life/psychology , Aged , Aged, 80 and over , Exercise/psychology , Female , Humans , Male , Middle Aged , Social Environment , Surveys and Questionnaires , Time Factors
13.
Cardiovasc Diagn Ther ; 4(6): 480-6, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25610805

ABSTRACT

BACKGROUND: Few studies have examined the very long-term outcomes after implantation of drug-eluting stents (DES) coated with biodegradable polymers (BP). This report presents the 5-year clinical follow-up of patients treated with BP-DES in the randomized PAINT trial. METHODS: The PAINT study is a prospective, multicenter randomized controlled trial that allocated 274 patients for treatment with two BP-DES formulations [paclitaxel-eluting stents (PES) or sirolimus-eluting stents (SES)] or bare metal stents (BMS) in a 1:2:2 ratio, respectively. The primary end-point of this sub-study was defined as the composite of the major cardiac adverse events (MACE) cardiac death, myocardial infarction (MI) or ischemia-driven target vessel revascularization (TVR) at 5 years. RESULTS: The 5-year MACE rates were different among the groups: 35.3%, 22.5% and 16.9% for BMS, PES and SES, respectively (P<0.05 for both DES vs. bare stent comparisons). The primary end-point was mainly driven by TVR: 31.8%, 14.1% and 12.2% for bare stents, PES and SES, respectively (P<0.05 for both DES vs. bare stent comparisons). The incidence of stent thrombosis (ST) was null for BMS during the entire follow-up. There was no definite or probable ST in the SES group after the second year, while one patient (1.0%) presented with a definite ST episode in the PES group between 4 and 5 years. CONCLUSIONS: The tested biodegradable-polymer coated stents releasing either paclitaxel or sirolimus, compared with same bare metal platform, sustained their effectiveness in reducing combined major adverse cardiac events and re-intervention without an increase in ST during 5 years of follow-up.

14.
Arq. bras. cardiol ; 99(6): 1129-1134, dez. 2012. tab
Article in Portuguese | LILACS | ID: lil-662373

ABSTRACT

FUNDAMENTO: A exposição ao meio de contraste radiográfico pode causar comprometimento agudo da função renal. Há evidências limitadas e conflitantes de que a hidratação com bicarbonato de sódio previne a Nefropatia Induzida por Contraste (NIC) em pacientes submetidos a cateterismo cardíaco. OBJETIVO: O presente estudo teve como objetivo determinar se o bicarbonato de sódio é superior à hidratação com soro fisiológico para evitar a nefropatia em pacientes de risco submetidos a cateterismo cardíaco. MÉTODOS: Trezentos e um pacientes submetidos a intervenção coronariana percutânea ou angiografia coronariana com creatinina sérica > 1,2 mg/dL ou Taxa de Filtração Glomerular (TFG) < 50 mL/min, foram randomizados para receber hidratação com bicarbonato de sódio a partir de 1 hora antes do procedimento, e 6 horas após o procedimento, ou hidratação com solução salina a 0,9%. A NIC foi definida como um aumento de 0,5 mg/dL na creatinina em 48h. RESULTADOS: Dezoito pacientes (5,9%) desenvolveram nefropatia induzida por contraste: 9 pacientes no grupo do bicarbonato (6,1%) e 9 pacientes no grupo da solução salina (6,0%), p = 0,97. A variação na creatinina sérica foi semelhante em ambos os grupos, 0,01 ± 0,26 mg/dL no grupo do bicarbonato, e 0,01 ± 0,35 mg/dL no grupo da solução salina, p = 0,9. Não foi observada diferença estatística entre a alteração na taxa de filtração glomerular (0,89 ± 9 mL/ min vs. 2,29 ± 10 mL/min, p = 0,2, grupo do bicarbonato e grupo da solução salina, respectivamente). CONCLUSÃO: A hidratação com bicarbonato de sódio não foi superior ao soro fisiológico na prevenção a nefropatia induzida pelo contraste, em pacientes de risco submetidos a cateterismo cardíaco.


BACKGROUND: Radiographic contrast media exposition can cause acute renal function impairment. There is limited and conflicting evidence that hydration with sodium bicarbonate prevents contrast-induced nephropathy (CIN) in patients undergoing cardiac catheterization. OBJECTIVE: The present study was aimed at determining whether sodium bicarbonate is superior to hydration with saline to prevent nephropathy in patients at risk undergoing cardiac catheterization. METHODS: Three hundred and one patients undergoing coronary angiography or percutaneous coronary intervention with serum creatinine > 1.2mg/dL or glomerular filtration rate (GFR) < 50ml/min were randomized to receive hydration with sodium bicarbonate starting 1 hour before the procedure and 6 hours after the procedure, or hydration with 0.9% saline. CIN was defined as an increase of 0.5mg/dL in creatinine in 48h RESULTS: Eighteen patients (5.9%) developed contrast induced nephropathy: 9 patients in the bicarbonate group (6.1%) and 9 patients in the saline group (6.0%), p = 0.97. The change in serum creatinine was similar in both groups, 0.01 ± 0.26 mg/dL in the bicarbonate group and 0.01 ± 0.35 mg/dL in the saline group, p = 0.9. No statistical difference was observed between the change in glomerular filtration rate (0.89 ± 9 ml/min vs. 2.29 ± 10 ml/min, p = 0.2 bicarbonate group and saline group, respectively). CONCLUSION: Hydration with sodium bicarbonate was not superior to saline to prevent contrast media induced nephropathy in patients at risk undergoing cardiac catheterization.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Cardiac Catheterization , Contrast Media/adverse effects , Fluid Therapy/methods , Kidney Diseases/chemically induced , Kidney Diseases/prevention & control , Sodium Bicarbonate/therapeutic use , Creatinine/blood , Glomerular Filtration Rate/drug effects , Risk Factors , Statistics, Nonparametric , Sodium Chloride/therapeutic use , Time Factors , Treatment Outcome
15.
Rev. salud pública ; 14(6): 30-40, nov.-dic. 2012. ilus
Article in Portuguese | LILACS | ID: lil-703433

ABSTRACT

Objetivo O presente estudo objetivou analisar a associação entre o estado nutricional (sobrepeso e obesidade) e a percepção de saúde em idosas de regiões de baixa renda do município de Curitiba, Brasil. Métodos A amostra foi composta por 449 idosas, participantes do programa Idoso em Movimento em alguns bairros de baixa renda do referido município. O peso corporal e a estatura foram mensurados para cálculo do Índice de Massa Corporal (IMC). Os pontos de corte do IMC de 25 e 30 kg/m² foram considerados para determinação do sobrepeso e obesidade, respectivamente. Uma questão específica foi utilizada para avaliar a percepção de saúde das idosas, sendo classificada como percepção de saúde positiva ou negativa. A análise dos dados apropriou-se da estatística descritiva, teste de Kruskal-Wallis e Qui-quadrado. A regressão logística binária foi utilizada para identificar a associação entre o estado nutricional e percepção de saúde, sendo controlada pela idade, classificação econômica, estado civil, anos de escolaridade, situação ocupacional e tempo semanal de atividade física. O nível de significância foi de 5 %. Resultados A obesidade esteve significativamente associada à percepção de saúde negativa (p<0,05). Idosas com obesidade tiveram cerca de duas vezes mais chances de ter uma percepção de saúde negativa. A condição de sobrepeso não esteve associada com uma percepção de saúde negativa. Conclusão A redução da obesidade em populações de baixa renda pode ser fundamental para a promoção de uma percepção de saúde positiva entre idosas.


Objective The present study was aimed at analyzing the association between elderly women's perception of their nutritional status (overweight and obesity) regarding their overall health in low-income neighborhoods in Curitiba, Brazil. Methods The sample consisted of 449 elderly women participating in the Idoso em Movimento program in low-income neighborhoods in Curitiba. Body weight and height were measured to calculate their Body Mass Index (BMI); 25 kg/m² and 30 kg/m² cut-off points were considered for determining weight status regarding being overweight and obese, respectively. A specific question concerning elderly health perception was used for classifying them into negative or positive health perception categories. Kruskal-Wallis and Chi-square tests were used for data analysis in terms of descriptive statistics. Binary logistic regression was used for analyzing the association between weight status and health perception, controlling for age, economic status, marital status, years spent in formal education, occupational status and time spent on physical activity per week. A 5 % significance level was used. Results Obesity was significantly associated with a perception of suffering negative health (p<0.05). Obese elderly women were twice as likely to have a negative perception of their health. Being overweight was not associated with a negative perception of health. Conclusion Decreasing obesity in obese low-income elderly is paramount for promoting better health perception in this risk group.


Objetivo Analizar la asociación entre el estado nutricional (sobrepeso y obesidad) y la percepción de salud de mujeres adultas mayores en localidades de bajos ingresos de la ciudad de Curitiba, Brasil. Métodos La muestra contó con 449 participantes de la tercera edad en el programa de movimiento en algunos barrios de bajos ingresos de esta ciudad. El peso corporal y la estatura se midieron para calcular el Índice de Masa Corporal (IMC). Los puntos de corte de IMC de 25 y 30 kg/m² fueron considerados para determinar el sobrepeso y la obesidad, respectivamente. Fue incluida una pregunta para evaluar la percepción de salud. Análisis de los datos utilizó la estadística descriptiva, prueba de Kruskal-Wallis y Chi-cuadrado. La regresión logística binaria se utilizó para determinar la asociación entre el estado nutricional y la percepción de la salud, controlado por edad, situación económica, estado civil, escolaridad, situación laboral y la actividad física. El nivel de significancia utilizado fue 5 %. Resultados La obesidad se asoció significativamente con la percepción de salud negativa. Las adultas mayores con obesidad fueron dos veces más propensas a tener una percepción negativa de la salud. La condición de sobrepeso no se asoció con una percepción negativa de la salud. Conclusión Los programas dirigidos a la prevención de la obesidad y la promoción de la salud en adultas mayores de bajos recursos pueden orientar sus acciones para una mejor percepción para la salud en este subgrupo.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Middle Aged , Nutritional Status , Obesity , Self Concept , Body Mass Index , Brazil , Cross-Sectional Studies , Obesity/psychology , Poverty
16.
Arq Bras Cardiol ; 99(6): 1129-34, 2012 Dec.
Article in English, Portuguese | MEDLINE | ID: mdl-23184077

ABSTRACT

BACKGROUND: Radiographic contrast media exposition can cause acute renal function impairment. There is limited and conflicting evidence that hydration with sodium bicarbonate prevents contrast-induced nephropathy (CIN) in patients undergoing cardiac catheterization. OBJECTIVE: The present study was aimed at determining whether sodium bicarbonate is superior to hydration with saline to prevent nephropathy in patients at risk undergoing cardiac catheterization. METHODS: Three hundred and one patients undergoing coronary angiography or percutaneous coronary intervention with serum creatinine > 1.2mg/dL or glomerular filtration rate (GFR) < 50 ml/min were randomized to receive hydration with sodium bicarbonate starting 1 hour before the procedure and 6 hours after the procedure, or hydration with 0.9% saline. CIN was defined as an increase of 0.5mg/dL in creatinine in 48 h RESULTS: Eighteen patients (5.9%) developed contrast induced nephropathy: 9 patients in the bicarbonate group (6.1%) and 9 patients in the saline group (6.0%), p = 0.97. The change in serum creatinine was similar in both groups, 0.01 ± 0.26 mg/dL in the bicarbonate group and 0.01 ± 0.35 mg/dL in the saline group, p = 0.9. No statistical difference was observed between the change in glomerular filtration rate (0.89 ± 9 ml/min vs. 2.29 ± 10 ml/min, p = 0.2 bicarbonate group and saline group, respectively). CONCLUSION: Hydration with sodium bicarbonate was not superior to saline to prevent contrast media induced nephropathy in patients at risk undergoing cardiac catheterization.


Subject(s)
Cardiac Catheterization , Contrast Media/adverse effects , Fluid Therapy/methods , Kidney Diseases/chemically induced , Kidney Diseases/prevention & control , Sodium Bicarbonate/therapeutic use , Aged , Creatinine/blood , Female , Glomerular Filtration Rate/drug effects , Humans , Male , Middle Aged , Risk Factors , Sodium Chloride/therapeutic use , Statistics, Nonparametric , Time Factors , Treatment Outcome
17.
EuroIntervention ; 8(1): 117-9, 2012 May 15.
Article in English | MEDLINE | ID: mdl-22580255

ABSTRACT

AIMS: The long-term clinical performance of drug-eluting stents (DES) coated with biodegradable polymers is poorly known. METHODS AND RESULTS: A total of 274 coronary patients were randomly allocated to paclitaxel-eluting stents, sirolimus-eluting stents, or bare metal stents (2:2:1 ratio). The two DES used the same biodegradable polymers and were identical except for the drug. At three years, the pooled DES population had similar rates of cardiac death or myocardial infarction (9.0% vs. 7.1; p=0.6), but lower risk of repeat interventions (10.0% vs. 29.9%; p<0.01) than controls with bare stents. The cumulative 3-year incidence of definite or probable stent thrombosis in the pooled DES group was 2.3% (first year: 1.8%; second year: 0.4%; third year: zero). There were no significant differences in outcomes between paclitaxel- and sirolimus-eluting stents. CONCLUSIONS: The biodegradable-polymer coated DES releasing either paclitaxel or sirolimus were effective in reducing the 3-year rate of re-interventions.


Subject(s)
Absorbable Implants , Angioplasty, Balloon, Coronary/instrumentation , Coronary Artery Disease/therapy , Drug-Eluting Stents , Polymers , Aged , Angioplasty, Balloon, Coronary/adverse effects , Cardiovascular Agents/administration & dosage , Coronary Artery Disease/mortality , Female , Follow-Up Studies , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Myocardial Infarction/etiology , Paclitaxel/administration & dosage , Proportional Hazards Models , Prosthesis Design , Risk Assessment , Risk Factors , Sirolimus/administration & dosage , Thrombosis/etiology , Time Factors , Treatment Outcome
18.
Arq. bras. cardiol ; 98(4): 290-299, abr. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-639415

ABSTRACT

FUNDAMENTO: Não há consenso sobre o impacto do implante de stent sobre a função endotelial no longo prazo. Há relatos de disfunção endotelial aumentada com stent com sirolimus quando comparado com o stent metálico convencional (BMS). OBJETIVO: Este estudo visa a avaliar o impacto do BMS e o efeito do sirolimus por via oral sobre a função endotelial. MÉTODOS: Quarenta e cinco pacientes foram randomizados em três grupos: BMS + altas doses de sirolimus oral (dose inicial de 15 mg, seguida de 6 mg/dia durante quatro semanas); BMS + baixa dose de sirolimus (6 mg, seguida de 2 mg por dia durante quatro semanas) e BMS sem sirolimus. Mudanças na vasoconstrição ou vasodilatação, em um segmento de 15 milímetros começando pelo extremo distal do stent em resposta a acetilcolina e nitroglicerina, foram avaliadas por angiografia quantitativa. RESULTADOS: Os grupos apresentaram características angiográficas semelhantes. A variação percentual de diâmetro em resposta a acetilcolina foi semelhante em todos os grupos, nos dois momentos (p = 0,469). Quatro horas após o implante de stent, o segmento alvo apresentou uma disfunção endotelial que se manteve após oito meses em todos os grupos. Em todos os grupos, a vasomotricidade independente de endotélio em resposta a nitroglicerina foi semelhante, às quatro horas e aos oito meses, com diâmetro do segmento alvo aumentado após a infusão de nitroglicerina (p = 0,001). CONCLUSÃO: A disfunção endotelial esteve igualmente presente no segmento distal de 15 milímetros do segmento tratado, às 4 horas e aos 8 meses após implante do stent. O sirolimus administrado por via oral durante quatro semanas para evitar a reestenose não afetou o estado de vasomotricidade endotélio dependente e independente.


BACKGROUND: There is no consensus regarding the impact of stenting on long-term endothelial function. There have been reports of increased endothelial dysfunction with sirolimus-eluting stents as compared to bare metal stenting (BMS). OBJECTIVE: This study aims to assess the impact of BMS and the effect of oral sirolimus on endothelial function. METHODS: Forty-five patients were randomized into three groups: BMS + high-dose oral sirolimus (initial dose of 15 mg, followed by 6 mg/day for four weeks); BMS + low-dose sirolimus (6 mg followed by 2 mg daily for four weeks); and BMS without sirolimus. Changes in vasoconstriction or vasodilation in a 15 mm segment starting at the distal stent end in response to acetylcholine and nitroglycerin were assessed by quantitative angiography. RESULTS: The groups had similar angiographic characteristics. The percent variation in diameter in response to acetylcholine was similar in all groups at the two time points (p = 0.469). Four hours after stenting, the target segment presented an endothelial dysfunction that was maintained after eight months in all groups. In all groups, endothelium-independent vasomotion in response to nitroglycerin was similar at four hours and eight months, with increased target segment diameter after nitroglycerin infusion (p = 0.001). CONCLUSION: The endothelial dysfunction was similarly present at the 15 mm segment distal to the treated segment, at 4 hours and 8 months after stenting. Sirolimus administered orally during 4 weeks to prevent restenosis did not affect the status of endothelium-dependent and independent vasomotion.


Subject(s)
Adult , Female , Humans , Middle Aged , Coronary Vessels/drug effects , Endothelium, Vascular/drug effects , Immunosuppressive Agents/pharmacology , Sirolimus/pharmacology , Stents/adverse effects , Vasomotor System/drug effects , Administration, Oral , Analysis of Variance , Acetylcholine/pharmacology , Acetylcholine/therapeutic use , Coronary Vessels/physiopathology , Endothelium, Vascular/physiopathology , Immunosuppressive Agents/administration & dosage , Nitroglycerin/pharmacology , Nitroglycerin/therapeutic use , Sirolimus/administration & dosage , Time Factors , Vasoconstriction/drug effects , Vasoconstriction/physiology , Vasodilation/drug effects , Vasodilation/physiology , Vasodilator Agents/pharmacology , Vasodilator Agents/therapeutic use , Vasomotor System/physiopathology
19.
Arq Bras Cardiol ; 98(4): 290-8, 2012 Apr.
Article in English, Portuguese | MEDLINE | ID: mdl-22406990

ABSTRACT

BACKGROUND: There is no consensus regarding the impact of stenting on long-term endothelial function. There have been reports of increased endothelial dysfunction with sirolimus-eluting stents as compared to bare metal stenting (BMS). OBJECTIVE: This study aims to assess the impact of BMS and the effect of oral sirolimus on endothelial function. METHODS: Forty-five patients were randomized into three groups: BMS + high-dose oral sirolimus (initial dose of 15 mg, followed by 6 mg/day for four weeks); BMS + low-dose sirolimus (6 mg followed by 2 mg daily for four weeks); and BMS without sirolimus. Changes in vasoconstriction or vasodilation in a 15 mm segment starting at the distal stent end in response to acetylcholine and nitroglycerin were assessed by quantitative angiography. RESULTS: The groups had similar angiographic characteristics. The percent variation in diameter in response to acetylcholine was similar in all groups at the two time points (p = 0.469). Four hours after stenting, the target segment presented an endothelial dysfunction that was maintained after eight months in all groups. In all groups, endothelium-independent vasomotion in response to nitroglycerin was similar at four hours and eight months, with increased target segment diameter after nitroglycerin infusion (p = 0.001). CONCLUSION: The endothelial dysfunction was similarly present at the 15 mm segment distal to the treated segment, at 4 hours and 8 months after stenting. Sirolimus administered orally during 4 weeks to prevent restenosis did not affect the status of endothelium-dependent and independent vasomotion.


Subject(s)
Coronary Vessels/drug effects , Endothelium, Vascular/drug effects , Immunosuppressive Agents/pharmacology , Sirolimus/pharmacology , Stents/adverse effects , Vasomotor System/drug effects , Acetylcholine/pharmacology , Acetylcholine/therapeutic use , Administration, Oral , Adult , Analysis of Variance , Coronary Vessels/physiopathology , Endothelium, Vascular/physiopathology , Female , Humans , Immunosuppressive Agents/administration & dosage , Male , Middle Aged , Nitroglycerin/pharmacology , Nitroglycerin/therapeutic use , Sirolimus/administration & dosage , Time Factors , Vasoconstriction/drug effects , Vasoconstriction/physiology , Vasodilation/drug effects , Vasodilation/physiology , Vasodilator Agents/pharmacology , Vasodilator Agents/therapeutic use , Vasomotor System/physiopathology
20.
Rev Salud Publica (Bogota) ; 14(6): 923-36, 2012 Oct.
Article in Portuguese | MEDLINE | ID: mdl-24892433

ABSTRACT

OBJECTIVE: The present study was aimed at analyzing the association between elderly women's perception of their nutritional status (overweight and obesity) regarding their overall health in low-income neighborhoods in Curitiba, Brazil. METHODS: The sample consisted of 449 elderly women participating in the Idoso em Movimento program in low-income neighborhoods in Curitiba. Body weight and height were measured to calculate their Body Mass Index (BMI); 25 kg/m(2) and 30 kg/m(2) cut-off points were considered for determining weight status regarding being overweight and obese, respectively. A specific question concerning elderly health perception was used for classifying them into negative or positive health perception categories. Kruskal-Wallis and Chi-square tests were used for data analysis in terms of descriptive statistics. Binary logistic regression was used for analyzing the association between weight status and health perception, controlling for age, economic status, marital status, years spent in formal education, occupational status and time spent on physical activity per week. A 5 % significance level was used. RESULTS: Obesity was significantly associated with a perception of suffering negative health (p<0.05). Obese elderly women were twice as likely to have a negative perception of their health. Being overweight was not associated with a negative perception of health. CONCLUSION: Decreasing obesity in obese low-income elderly is paramount for promoting better health perception in this risk group.


Subject(s)
Nutritional Status , Obesity , Self Concept , Aged , Aged, 80 and over , Body Mass Index , Brazil , Cross-Sectional Studies , Female , Humans , Middle Aged , Obesity/psychology , Poverty
SELECTION OF CITATIONS
SEARCH DETAIL