Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 146
Filter
1.
Cir Cir ; 92(4): 426-436, 2024.
Article in English | MEDLINE | ID: mdl-39079248

ABSTRACT

OBJECTIVE: To share our experience in creating precise anatomical models using available open-source software. METHODS: An affordable method is presented, where from a DICOM format of a computed tomography, a segmentation of the region of interest is achieved. The image is then processed for surface improvement and the DICOM format is converted to STL. Error correction is achieved and the model is optimized to be printed by stereolithography with a desktop 3D printer. RESULTS: Precise measurements of the dimensions of the DICOM file (CT), the STL file, and the printed model (3D) were carried out. For the C6 vertebra, the dimensions of the horizontal axis were 55.3 mm (CT), 55.337 mm (STL), and 55.3183 mm (3D). The dimensions of the vertebral body were 14.2 mm (CT), 14.551 mm (STL), and 14.8159 mm (3D). The length of the spinous process was 18.2 mm (CT), 18.283 mm (STL), and 18.2266 mm (3D), while its width was 8.5 mm (CT), 8.3644 mm (STL), and 8.3226 mm (3D). For the C7 vertebra, the dimensions of the horizontal axis were 58.6 mm (CT), 58.739 mm (STL), and 58.7144 mm (3D). The dimensions of the vertebral body were 14 mm (CT), 14.0255 mm (STL), and 14.2312 mm (3D). The length of the spinous process was 18.7 mm (CT), 18.79 mm (STL), and 18.6458 mm (3D), and its width was 8.9 mm (CT), 8.988 mm (STL), and 8.9760 mm (3D). CONCLUSION: The printing of a 3D model of bone tissue using this algorithm is a viable, useful option with high precision.


OBJETIVO: Compartir nuestra experiencia para crear modelos anatómicos precisos utilizando software con licencia abierta disponibles. MÉTODOS: Se presenta un método asequible, en donde a partir de un formato DICOM de una tomografía computarizada se logra una segmentación de la región de interés. Posteriormente se procesa la imagen para una mejora de superficie y se realiza la conversión de formato DICOM a STL. Se logra la corrección de errores y se optimiza el modelo para luego ser impreso por medio de estereolitografía con una impresora 3D de escritorio. RESULTADOS: Se efectuaron mediciones precisas de las dimensiones del archivo DICOM (TC), del archivo STL y del modelo impreso (3D). Para la vértebra C6, las dimensiones del eje horizontal fueron 55.3 mm (TC), 55.337 mm (STL) y 55.3183 mm (3D). Las dimensiones del cuerpo vertebral fueron 14.2 mm (TC), 14.551 mm (STL) y 14.8159 mm (3D). La longitud de la apófisis espinosa fue de 18.2 mm (TC), 18.283 mm (STL) y 18.2266 mm (3D), mientras que su ancho fue de 8.5 mm (TC), 8.3644 mm (STL) y 8.3226 mm (3D). Para la vértebra C7, las dimensiones del eje horizontal fueron 58.6 mm (TC), 58.739 mm (STL) y 58.7144 mm (3D). Las dimensiones del cuerpo vertebral fueron 14 mm (TC), 14.0255 mm (STL) y 14.2312 mm (3D). La longitud de la apófisis espinosa fue de 18.7 mm (TC), 18.79 mm (STL) y 18.6458 mm (3D), y su ancho fue de 8.9 mm (TC), 8.988 mm (STL) y 8.9760 mm (3D). CONCLUSIÓN: La impresión de un modelo en 3D de tejido óseo mediante este algoritmo resulta una opción viable, útil y con una alta precisión.


Subject(s)
Models, Anatomic , Printing, Three-Dimensional , Tomography, X-Ray Computed , Humans , Software , Imaging, Three-Dimensional/methods , Stereolithography , Cervical Vertebrae/diagnostic imaging , Cervical Vertebrae/anatomy & histology
2.
Int. j. morphol ; 42(3): 692-697, jun. 2024. ilus
Article in English | LILACS | ID: biblio-1564635

ABSTRACT

SUMMARY: To measure and study the anatomical morphological data of the lumbar 5 to sacral 1 intervertebral space with the aid of CT and design an anatomical anterior lumbosacral 3D printed integrated interbody fusion for the treatment of degenerative lumbosacral spine diseases. 100 adults (50 of each sex) who underwent CT examination of the lumbar spine in our hospital were selected, and their lumbar 5 to sacral 1 intervertebral space anatomical data were measured, including the anterior lumbar convexity angle, different sagittal and coronal heights, and the sagittal and coronal diameters of the superior and inferior endplates. The measured data were also statistically analyzed, and morphological design and study of the 3D printed integrated fusion device in the anterior lumbosacral spine was performed by applying computer software. When comparing the coronal and sagittal diameters of the superior and inferior endplates from lumbar 5 to sacral 1, the differences were statistically greater in men than in women (P0.001). When comparing the height at different positions in the median sagittal plane, both males and females showed an anterior high and posterior low pattern. In the coronal plane, both males and females showed the highest height in the middle position (P0.001). CT can measure the anatomical data of the lumbosacral spinal hiatus more accurately. The 3D-printed anterior integrated fusion device of the lumbosacral spine designed according to the analysis of the data results is more in line with the anatomical structure of the lumbosacral spine, fits well with the superior and inferior endplates, and effectively restores the height and anterior convexity angle of the lumbosacral space.


El objetivo de este trabajo fue medir y estudiar los datos morfológicos anatómicos del espacio intervertebral lumbar 5 a sacro 1 con la ayuda de TC y diseñar una fusión intersomática integrada anatómica lumbosacra anterior impresa en 3D para el tratamiento de enfermedades degenerativas de la columna lumbosacra. Se seleccionaron en nuestro hospital 100 adultos (50 de cada sexo) que se sometieron a un examen de TC de la columna lumbar y se midieron los datos anatómicos del espacio intervertebral lumbar 5 al sacro 1, incluyendo el ángulo de la convexidad lumbar anterior, diferentes alturas sagital y coronal, y los diámetros sagital y coronal de las placas terminales superior e inferior. Los datos medidos también se analizaron estadísticamente y se realizó el diseño morfológico y el estudio del dispositivo de fusión integrado impreso en 3D en la columna lumbosacra anterior mediante la aplicación de software informático. Al comparar los diámetros coronal y sagital de las placas terminales superior e inferior desde lumbar 5 hasta sacro 1, las diferencias fueron estadísticamente mayores en hombres que en mujeres (P 0,001). Al comparar la altura en diferentes posiciones en el plano mediano, tanto hombres como mujeres mostraron un patrón anterior alto y posterior bajo. En el plano coronal, tanto hombres como mujeres mostraron la altura más alta en la posición media (P0,001). La TC puede medir los datos anatómicos del hiato espinal lumbosacro con mayor precisión. El dispositivo de fusión anterior integrado impreso en 3D de la columna lumbosacra diseñado de acuerdo con el análisis de los resultados de los datos está más en línea con la estructura anatómica de la columna lumbosacra, se adapta bien a las placas terminales superior e inferior y restaura eficazmente la altura y la parte anterior del ángulo de convexidad del espacio lumbosacro.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Young Adult , Printing, Three-Dimensional , Lumbar Vertebrae/diagnostic imaging , Spine , Tomography, Spiral Computed , Lumbar Vertebrae/anatomy & histology
3.
Endocrinol Diabetes Nutr (Engl Ed) ; 71(3): 133-137, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38555110

ABSTRACT

Secondary basilar invagination or basilar impression is an anomaly at the craniovertebral junction where the odontoid process prolapses into the foramen magnum with the risk of compressing adjacent structures and obstructing the proper flow of cerebrospinal fluid (CSF). The incidence is less than 1% in the general population and occurs mainly in the first three decades of life when it is associated with malformations of the neuroaxis. In older age, the main aetiologies are diseases that alter bone mineral density. The clinical course is usually progressive and the most common symptoms are asthenia, cervical pain and restricted movement, but also dysphonia, dyspnoea and dysphagia. It is a progressive disease which, if left untreated, can cause severe neurological damage and death. We report the case of a 79-year-old woman with osteoporosis and progressive dysphagia leading to severe malnutrition, which conditioned the decision not to intervene due to the high perioperative risk.


Subject(s)
Deglutition Disorders , Odontoid Process , Platybasia , Female , Humans , Aged , Platybasia/complications , Platybasia/diagnosis , Platybasia/surgery , Deglutition Disorders/etiology , Foramen Magnum , Odontoid Process/abnormalities , Odontoid Process/surgery
4.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1558176

ABSTRACT

Actualmente los factores que influyen en la supervivencia de los dientes trasplantados han podido ser controlados con el uso de la tecnología. El autotrasplante dental guiado ha logrado más predictibilidad y eficiencia, además, h a reducido los tiempos de transferencia desde la extracción hasta el trasplante. El objetivo de esta revisión es describir los protocolos de autotrasplante dental guiado, sus tasas de supervivencia y éxito publicados en la literatura actual. Esta revisió n fue realizada siguiendo la pauta PRISMA. La búsqueda se realizó en MEDLINE, Google Académico, ScienceDirect y SciELO, con los términos "autotransplant", "autotransplantation", "autotransplanting", "dental", "tooth", "teeth", "guided", "guide" con filtro de publicación de 10 años. Se realizó evaluación de riesgo de sesgo mediante pautas Joanna Briggs Institute (JBI) a los estudios, incluyendo en esta revisión sólo con riesgo medio y bajo. Los datos de cada artículo se tabularon en una tabla realizada en el procesador de texto en línea "Google Docs". Diez estudios cumplieron los criterios mencionados y fueron incluidos. Fueron evaluados un total de 37 pacientes entre 9 a 64 años. Los dientes donantes más frecuentes fueron premolares y terceros molares. En la mayoría de los casos los pacientes se encontraban sin antecedentes mórbidos de relevancia. El éxito fue evaluado mediante diversos criterios clínicos y radiográficos. Por otro lado, la supervivencia fue evaluada durante los seguimientos respecto a la permanencia del diente en boca. Este tipo de tratamiento no es muy conocido y los estudios incluidos fueron escasos, por otro lado, estos son de bajo nivel de evidencia (reportes de casos y serie de casos). Los protocolos evaluados difieren en algunas características, sin embargo, todos logran altas tasas de supervivencia y éxito. Igualmente, se presentan algunos fracasos, dónde los dientes debieron ser extraídos por movilidad e inflamación.


Currently, the factors that influence the survival of transplanted teeth have been controlled with the use of technology. Guided dental autotransplantation has achieved greater predictability and efficiency, and has also reduced transfer times from extraction to transplantation. The aim of this review is to describe the protocols of guided dental autotransplantation, their survival and success rates published in the current literature. This review was performed following the PRISMA guideline. The search was carried out in MEDLINE, Google Scholar, ScienceDirect and SciELO, with the terms "autotransplant", "autotransplantation", "autotransplanting", "autotransplanting", "dental", "tooth", "teeth", "guided", "guide" with a 10-year publication filter. Studies were assessed for risk of bias using Joanna Briggs Institute (JBI) guidelines, including only medium and low risk studies in this review. The data for each article were tabulated in a table created in the online word processor "Google Docs". Ten studies met the selection criteria and were included. A total of 37 patients between 9 and 64 years of age were evaluated. The most frequent donor teeth were premolars and third molars. In most cases the patients had no relevant morbid history. Success was evaluated by means of various clinical and radiographic criteria. On the other hand, survival was evaluated during the follow-ups with respect to the permanence of the tooth in the mouth. This type of treatment is not very well known, and the studies included were scarce; on the other hand, they are of a low level of evidence (case reports and case series). The evaluated protocols differ in some characteristics, however, all of them achieve high survival and success rates. There are also some failures, where teeth had to be extracted due to mobility and inflammation.

5.
Neurocirugía (Soc. Luso-Esp. Neurocir.) ; 35(1): 30-40, enero-febrero 2024. ilus, tab
Article in Spanish | IBECS | ID: ibc-229500

ABSTRACT

Objetivo: El objetivo principal de este estudio ha sido demostrar por qué la impresión aditiva permite hacer más visibles y entendibles los procesos patológicos quirúrgicos complejos que afectan al raquis, aumentando la precisión, la seguridad y la fiabilidad del procedimiento quirúrgico.MetodologíaSe realizó una revisión sistemática de los trabajos publicados en los últimos 10 años, sobre la cirugía de raquis asistida por impresión 3D, de acuerdo con la declaración PRISMA 2020. Con las palabras clave «printing 3D» y «spine surgery» se hicieron búsquedas en las bases de datos Pubmed, Embase, Cochrane Database of Systematic Reviews, Google Scholar y Opengrey, que se completó con la búsqueda manual a través de la lista de referencias bibliográficas de los artículos que fueron seleccionados siguiendo los criterios de inclusión y exclusión definidos.ResultadosDel análisis de los 38 estudios seleccionados resultó que la impresión 3D es útil en la planificación quirúrgica, en la enseñanza médica, en la relación médico-paciente, así como en el diseño de plantillas de navegación e implantes de raquis y, en investigación, ofreciendo un magnífico apoyo al proceder quirúrgico.ConclusionesEl uso de biomodelos impresos de forma tridimensional permite: hacer más visibles y entendibles los procesos patológicos quirúrgicos complejos que afectan al raquis; aumentar la exactitud, precisión y seguridad del procedimiento quirúrgico; y abrir la posibilidad de poner en práctica tratamientos personalizados, fundamentalmente en la cirugía tumoral. (AU)


Objective: The main objective of this study has been to demonstrate why additive printing allows to make complex surgical pathological processes that affect the spine more visible and understandable, increasing precision, safety and reliability of the surgical procedure.MethodsA systematic review of the articles published in the last 10 years on 3D printing-assisted spinal surgery was carried out, in accordance with PRISMA 2020 declaration. Keywords «3D printing» and «spine surgery» were searched in Pubmed, Embase, Cochrane Database of Systematic Reviews, Google Scholar and Opengrey databases, which was completed with a manual search through the list of bibliographic references of the articles that were selected following the defined inclusion and exclusion criteria.ResultsFrom the analysis of the 38 selected studies, it results that 3D printing is useful in surgical planning, medical teaching, doctor–patient relationship, design of navigation templates and spinal implants, and research, optimizing the surgical process by focusing on the patient, offering magnificent support during the surgical procedure.ConclusionsThe use of three-dimensional printing biomodels allows: making complex surgical pathological processes that affect the spine more visible and understandable; increase the accuracy, precision and safety of the surgical procedure, and open up the possibility of implementing personalized treatments, mainly in tumor surgery. (AU)


Subject(s)
Humans , Physician-Patient Relations , Printing, Three-Dimensional , Prostheses and Implants , Reproducibility of Results
6.
Neurocirugía (Soc. Luso-Esp. Neurocir.) ; 35(1): 51-56, enero-febrero 2024. ilus
Article in English | IBECS | ID: ibc-229503

ABSTRACT

Neurosurgical management of basilar invagination (BI) has traditionally been aimed at direct cervicomedullary decompression through transoral dens resection or suboccipital decompression with supplemental instrumented fixation. Dr. Goel introduced chronic atlantoaxial dislocation (AAD) as the etiology in most cases of BI and described a technique for distracting the C1–C2 joint with interfacet spacers to achieve reduction and anatomic realignment. We present our modification to Goel’s surgical technique, in which we utilize anterior cervical discectomy (ACD) cages as C1–C2 interfacet implants. A young adult male presented to our institution with BI, cervicomedullary compression, occipitalization of C1, and Chiari 1 malformation. There was AAD of C1 over the C2 lateral masses. This reduced some with preoperative traction. He underwent successful C1–C2 interfacet joint reduction and arthrodesis with anterior cervical discectomy (ACD) cages and concomittant occiput to C2 instrumented fusion. BI can be effectively treated through reduction of AAD and by utilizing ACD cages as interfacet spacers. (AU)


El tratamiento neuroquirúrgico tradicional para la impresión basilar es principalmente a través de un abordaje trans-oral para la resección del proceso odontoide, seguido de una descompresión suboccipital con instrumentación posterior cervical. Dr. Goel presenta la dislocación atlanto-axial (AA) como una de las etiologías principales en los casos de impresión basilar. A su vez, describió la técnica quirúrgica que incluye la distracción de la articulación AA con cajas para fusión permitiendo la reducción y reajuste anatómico cervical. En este artículo presentamos una variación a la técnica quirúrgica del Dr. Goel en el cual utilizamos implantes utilizados en la discectomía y fusión cervical anterior (DFCA) para la articulación facetaria de C1–C2. Presentamos un paciente adulto masculino que evaluamos en nuestra institución con impresión basilar, compresión cérvico-medular, fusión occipital con el atlas y malformación de Chiari tipo 1. En adición, el paciente tenía evidencia radiográfica de dislocación AA. Se logro obtener reducción mínima de la impresión basilar con tracción cervical pre-operatoria. Luego, se sometió al tratamiento quirúrgico que consistió en el uso de implantes cervicales para la reducción y fusión de la articulación facetaria de C1–C2 complementado por instrumentación y fusión craneocervical. Esta técnica presentada sugiere que la reducción y reajuste anatómico cervical de la dislocación AA con implantes utilizados para DFCA puede ser efectivo para el tratamiento de impresión basilar. (AU)


Subject(s)
Humans , Decompression, Surgical/methods , Joint Dislocations/diagnostic imaging , Platybasia , Diskectomy, Percutaneous
7.
Rev. cir. (Impr.) ; 76(1)feb. 2024.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1565444

ABSTRACT

Introducción: La anatomía hepática siempre ha sido un reto por su complejidad y variabilidad. En los últimos años, el abaratamiento de los costes ha permitido la generación de modelos 3D individualizados para cada paciente que pueden facilitar el abordaje quirúrgico de las lesiones. El objetivo principal fue determinar la utilidad del modelado 3D preoperatorio para la planificación quirúrgica en pacientes con lesiones hepáticas. Métodos: Se trata de un estudio de casos de 38 pacientes intervenidos por lesiones hepáticas múltiples ocupantes de espacio, en el cual, en un grupo seleccionado, en 19 pacientes se utilizó un modelo impreso 3D para planificar la cirugía (grupo 3D) y el otro grupo sin el modelo impreso 3D (grupo control). Resultados: Se observó una diferencia de medias significativa en el número de lesiones; mayor en el grupo 3D al realizar el test de Wilcoxon (p < 0,001) y un mayor número de casos con afectación vascular en este mismo grupo al realizar Chi cuadrado Pearson (p = 0,008). El resto de variables no mostraron diferencias estadísticamente significativas. A pesar de esto, la mortalidad se redujo a 0 cuando se usan modelos impresos en 3D. Conclusión: La impresión 3D permite planear, de manera más precisa, cirugías complejas del hígado, ayuda a la inclusión y exclusión de los pacientes para la cirugía, disminuyendo el tiempo de la sala de operaciones, la posterior hospitalización y las complicaciones quirúrgicas.


Introduction: Liver anatomy has always been a challenge due to its complexity and variability. In recent years, lower costs has allowed the generation of individualized 3D models for each patient, which can facilitate the surgical approach to liver lesions. The main objective was to determine usefulness of preoperative 3D modeling for surgical planning in patients with liver lesions. Methods: Quasi-experimental before-after study. 19 cases were included in which surgery was planned using a 3D printed model (13 bilobar hepatectomies, 3 of them with vascular involvement, and 6 unilobar hepatectomies, 1 of them with vascular involvement), and another 19 cases whose planning was carried out without a 3D printed model (7 bilobar segmental hepatic resections and 12 unilobar segmental resections. None of these cases had vascular involvement). Results: A significant difference in mean lesion count was observed, higher in the group of cases when performing the Wilcoxon test (p < 0.001), and a higher number of cases with vascular involvement in the same group when performing the Pearson chi-square test (p = 0.008). The rest of the variables did not show statistically significant differences. Despite this, mortality was reduced to 0 when 3D printed models were used. Conclusion: 3D printing allows for more precise planning of complex liver surgeries, helps with the inclusion and exclusion of patients for surgery, reduces operating room time, postoperative hospitalization, and surgical complications.

8.
Rev Esp Cir Ortop Traumatol ; 68(3): T262-T270, 2024.
Article in English, Spanish | MEDLINE | ID: mdl-38253238

ABSTRACT

INTRODUCTION: Bone defects are one of the main limitations in orthopaedic surgery and traumatology. For this reason, multiple bone replacement systems have been developed, either by prosthetic implant or by substitution with osteoforming substances, whose limitations are their survival and lack of structurality, respectively. The objective of this work is the generation of a new material for the creation of biologically active structures that have sufficient tensile strength to maintain the structure during remodelling. MATERIAL AND METHODS: A new filament based on the fusion of natural polylactide acid (PLA) powder was designed for the generation of pieces by means of fused deposition modelling (FDM) on which to carry out tensile mechanical tests of osteosynthesis material. A total of 13 groups with different cortical thickness, filling and layer height were carried out, with 10 tensile tests in each group, defining the tensile breaking limit for each group. The regression lines for each group and their mechanical resistance to traction on the filament used were determined. RESULTS: The filament ratio per contact surface unit with the osteosynthesis used was the main determinant of the mechanical resistance to traction, either at the expense of the increase in cortical thickness or by the increase in the percentage of cancellous bone filling. Layer height had a minor effect on tensile strength. The regression value was high for cortical thickness and cancellous filling, being elements with a predictable biomechanical behaviour. CONCLUSIONS: The new methodology allows the creation of personalised neutral and implantable PLA bone matrices for the reconstruction of large bone defects by means of 3D printing by FDM with a mechanical resistance to traction greater than that of current biological support structures.

9.
Rev. estomatol. Hered ; 34(1): 69-75, ene.-mar. 2024. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1565546

ABSTRACT

RESUMEN El diseño asistido por computadora y la fabricación asistida por ordenador (CAD-CAM, por sus siglas en inglés) se ha aplicado en odontología para la confección y el análisis de diversos tratamientos dentales. Inicia con la captura de imágenes a través de escáneres intraorales, contando con diversos tipos de softwares y sistemas de exportación de imágenes y tecnología. Las ventajas de este flujo de trabajo digital son el mejor ajuste, el empleo de menor tiempo clínico y la celeridad en tratamientos dentales, además de que brinda una mayor practicidad en el uso de los cirujanos dentistas. La precisión que brinda es clínicamente aceptable en comparación con los métodos convencionales, por lo cual existe suficiente evidencia para su validez; sin embargo, se debe tener en cuenta que diversos factores pueden alterar el resultado, como la experiencia del operador, el tipo de escáner, el tipo de software, la actualización del software, el principio de escaneo del escáner, el ambiente, la secuencia de escaneo y las estructuras bucales. El presente artículo de revisión tiene como objetivo analizar la literatura sobre las diferentes características y propiedades que presentan los escáneres intraorales en la actualidad, así como la evidencia de los posibles beneficios y la precisión de las técnicas de impresión digital frente a las técnicas de impresión convencionales.


ABSTRACT Computer-aided design and computer-aided manufacturing (CAD-CAM) has been applied in dentistry for the preparation and analysis of various dental treatments. It starts with capturing images through intraoral scanners, having different types of software and image export systems and technology. The advantages of this digital workflow are the following: better adjustment, shorter clinical time, and speed in dental treatments, in addition to providing greater practicality for dental surgeons. The accuracy he provide is clinically acceptable in comparison with conventional methods, so there is sufficient evidence for their validity; however, it should be taken into account that several factors can alter the result, such as the operator's experience, the type of scanner, the type of software, the software update, the scanning principle of the scanner, the environment, the scanning sequence, and the oral structures. The present review article aims to analyze the literature on the different characteristics and properties that intraoral scanners present today and the evidence of the potential benefits and accuracy of digital impression techniques versus conventional impression techniques.


RESUMO O desenho assistido por computador e o fabrico assistido por computador (CAD-CAM) têm sido aplicados na medicina dentária para a preparação e análise de vários tratamentos dentários. Começa com a captura de imagens através de scanners intraorais, com vários tipos de software e sistemas e tecnologia de exportação de imagens. As vantagens deste fluxo de trabalho digital são as seguintes: melhor ajuste, menor tempo clínico, rapidez nos tratamentos dentários, além de proporcionar maior praticidade no uso dos cirurgiões-dentistas. A precisão que proporcionam é clinicamente aceitável quando comparada com os métodos convencionais, pelo que existem evidências suficientes para a sua validade; no entanto, deve ter-se em conta que vários fatores podem alterar o resultado, tais como a experiência do operador, o tipo de scanner, o tipo de software, a atualização do software, o princípio de digitalização do scanner, o ambiente, a sequência de digitalização e as estruturas orais. Este artigo de revisão tem como objetivo analisar a literatura sobre as diferentes características e propriedades dos scanners intraorais atuais, bem como a evidência dos potenciais benefícios e precisão das técnicas de moldagem digital em comparação com as técnicas de moldagem convencionais.

10.
Neurocirugia (Astur : Engl Ed) ; 35(1): 51-56, 2024.
Article in English | MEDLINE | ID: mdl-36934973

ABSTRACT

Neurosurgical management of basilar invagination (BI) has traditionally been aimed at direct cervicomedullary decompression through transoral dens resection or suboccipital decompression with supplemental instrumented fixation. Dr. Goel introduced chronic atlantoaxial dislocation (AAD) as the etiology in most cases of BI and described a technique for distracting the C1-C2 joint with interfacet spacers to achieve reduction and anatomic realignment. We present our modification to Goel's surgical technique, in which we utilize anterior cervical discectomy (ACD) cages as C1-C2 interfacet implants. A young adult male presented to our institution with BI, cervicomedullary compression, occipitalization of C1, and Chiari 1 malformation. There was AAD of C1 over the C2 lateral masses. This reduced some with preoperative traction. He underwent successful C1-C2 interfacet joint reduction and arthrodesis with anterior cervical discectomy (ACD) cages and concomittant occiput to C2 instrumented fusion. BI can be effectively treated through reduction of AAD and by utilizing ACD cages as interfacet spacers.


Subject(s)
Atlanto-Axial Joint , Joint Dislocations , Young Adult , Male , Humans , Atlanto-Axial Joint/diagnostic imaging , Atlanto-Axial Joint/surgery , Joint Dislocations/diagnostic imaging , Joint Dislocations/surgery , Decompression, Surgical/methods
11.
Neurocirugia (Astur : Engl Ed) ; 35(1): 30-40, 2024.
Article in English | MEDLINE | ID: mdl-37473871

ABSTRACT

OBJECTIVE: The main objective of this study has been to demonstrate why additive printing allows to make complex surgical pathological processes that affect the spine more visible and understandable, increasing precision, safety and reliability of the surgical procedure. METHODS: A systematic review of the articles published in the last 10 years on 3D printing-assisted spinal surgery was carried out, in accordance with PRISMA 2020 declaration. Keywords "3D printing" and "spine surgery" were searched in Pubmed, Embase, Cochrane Database of Systematic Reviews, Google Scholar and Opengrey databases, which was completed with a manual search through the list of bibliographic references of the articles that were selected following the defined inclusion and exclusion criteria. RESULTS: From the analysis of the 38 selected studies, it results that 3D printing is useful in surgical planning, medical teaching, doctor-patient relationship, design of navigation templates and spinal implants, and research, optimizing the surgical process by focusing on the patient, offering magnificent support during the surgical procedure. CONCLUSIONS: The use of three-dimensional printing biomodels allows: making complex surgical pathological processes that affect the spine more visible and understandable; increase the accuracy, precision and safety of the surgical procedure, and open up the possibility of implementing personalized treatments, mainly in tumor surgery.


Subject(s)
Printing, Three-Dimensional , Spine , Humans , Physician-Patient Relations , Prostheses and Implants , Reproducibility of Results , Spine/surgery
12.
Article in English | LILACS-Express | LILACS | ID: biblio-1550993

ABSTRACT

Introduction: Three-dimensional printing is one of the technologies that promote change at an economic and social level, and one of the fundamental elements of industry 4.0. It has enormous potential for the future of medicine, establishing itself as a new paradigm. Despite its advantages, its use in our environment is incipient. Objective: To design and develop solutions based on three-dimensional technologies for the teaching and practice of biomedical sciences. Materials and methods: A technological development investigation was carried out between the Center for Assisted and Sustainable Manufacturing of the University of Matanzas and Matanzas University of Medical Sciences, between September 2019 and July 2022. The designs and fabrications were made from the acquisition of computed tomography images, or from a surface scanner, which were then processed, converted into Standard Tessellation Language format, printed, and post-processed. Virtual designs were developed using computer-aided design software. Results: Various solutions were developed including prototypes: biomodels for craniosynostosis repair and anatomical figures, custom cranial prosthesis mold, hand prosthesis, O2 line splitters, tissue scaffolds, syringe gun, face shields, breast prosthesis; autologous restoration mold and tissue expander. Conclusions: In all areas of application of this technology in medicine―except the printing of medicines, in the current context―, it is feasible to obtain solutions in the territory of Matanzas. It is therefore imperative that managers and the medical community in general, begin to acquire awareness, knowledge, and experience to ensure the optimal use of this technology.


Introducción: La impresión tridimensional es una de las tecnologías que promueve el cambio a nivel económico y social, y uno de los elementos fundamentales de la industria 4.0. Asimismo, constituye un enorme potencial para el futuro de la medicina, estableciéndose como un nuevo paradigma. A pesar de sus ventajas, su explotación en nuestro medio es incipiente. Objetivos: Diseñar y desarrollar soluciones basadas en tecnologías tridimensionales para la enseñanza y la práctica de las ciencias biomédicas. Materiales y métodos: Se realizó una investigación colaborativa, de desarrollo tecnológico entre el Centro de Fabricación Asistida y Sostenible de la Universidad de Matanzas y la Universidad de Ciencias Médicas de Matanzas, entre septiembre de 2019 y julio de 2022. Los diseños y fabricaciones se realizaron a partir de la adquisición de imágenes de tomografía computarizada, o desde un escáner de superficie, las que luego se procesaron, se convirtieron en formato Standard Tessellation Language, se imprimieron y posprocesaron. Los diseños virtuales se desarrollaron empleando un software de diseño asistido por computadora. Resultados: Se desarrollaron varias soluciones que incluyen varios prototipos: biomodelos para reparación de craneosinostosis y figuras anatómicas, molde de prótesis craneal personalizada, prótesis de mano, divisores de líneas de O2, andamios tisulares, pistola portajeringas, protectores faciales, prótesis de mama, molde para restauración autóloga y expansor tisular. Conclusiones: En todas las áreas de aplicación de esta tecnología en medicina―salvo en la impresión de medicamentos, en el contexto actual―, es factible obtener soluciones en el territorio de Matanzas. Es un imperativo, pues, que directivos y la comunidad médica en general, comiencen a adquirir conciencia, conocimientos y experiencias para garantizar la utilización óptima de esta tecnología.

13.
Odontoestomatol ; 26(43)2024.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1558608

ABSTRACT

Objetivo. Comparar la estabilidad dimensional de un hidrocoloide irreversible de vaciado convencional con hidrocoloides irreversibles de vaciado extendido. Metodología. Fueron evaluados cuatro productos con indicación de vaciado extendido: Jeltrate Plus (Denstply Sirona), Hydrogum 5 (Zhermack SpA), Algimax (Major), Kromopan (Lascod) y un producto de vaciado convencional (Tropicalgin; Zhermack SpA). Con cada producto se realizaron 10 impresiones y se vaciaron en yeso tipo III en cinco tiempos de almacenamiento diferentes (0, 24, 96, 120 y 168 horas). Un escáner para modelos tridimensionales se utilizó para digitalizar los modelos de yeso y realizar las mediciones correspondientes: sumatoria de las longitudes, variabilidad dimensional, porcentaje de variabilidad. Resultados. Las cinco marcas comerciales presentaron una sumatoria de longitudes mayor al grupo control (p<0,033). A las 0, 24 y 96h Tropicalgin e Hydrogum 5 presentaron significativamente menor variación dimensional en comparación con el modelo maestro (p<0,001). Los porcentajes de variabilidad oscilaron entre un 0.24 a 0.91%. Conclusiones. La estabilidad dimensional depende del producto utilizado. Almacenado correctamente, el hidrocoloide irreversible de vaciado convencional parece no sufrir alteraciones significativas hasta 96h, mientras que en el caso de Hydrogum 5 parece mantener su estabilidad dimensional hasta 168h.


Objetivo. Comparar a estabilidade dimensional de um hidrocolóide irreversível de vazamento convencional com hidrocolóides irreversíveis de vazamento prolongado. Metodologia. Foram avaliados quatro produtos com indicação de vazamento estendido: Jeltrate Plus (Denstply Sirona), Hydrogum 5 (Zhermack SpA), Algimax (Major), Kromopan (Lascod) e um produto de vaziamento convencional (Tropicalgin; Zhermack SpA). Para cada produto foram feitas 10 impressões e vazadas em gesso tipo III em cinco tempos de armazenamento diferentes (0, 24, 96, 120 e 168 horas). Um scanner de modelos tridimensionais foi utilizado para digitalizar os modelos de gesso e fazer as medições correspondentes: soma dos comprimentos, variabilidade dimensional, percentagem de variabilidade. Resultados. As cinco marcas comerciais apresentaram somatório de comprimentos maior que o grupo controle (p<0,033). Nos tempos 0, 24 e 96h Tropicalgin e Hydrogum 5 apresentaram variação dimensional significativamente menor em comparação ao modelo Mestre (p<0,001). Os percentuais de variabilidade variaram de 0,24 a 0,91%. Conclusões. A estabilidade dimensional depende do produto utilizado. Armazenado corretamente, o hidrocolóide irreversível de vaziamento convencional convencionalmente parece não sofrer alterações significativas até 96h, enquanto no caso do Hydrogum 5 parece manter sua estabilidade dimensional até 168h.


Aim . Compare the dimensional stability of a conventional pouring irreversible hydrocolloid with extended pouring irreversible hydrocolloids. Methodology. Four products with extended emptying indication were evaluated: Jeltrate Plus (Denstply Sirona), Hydrogum 5 (Zhermack SpA), Algimax (Major), Kromopan (Lascod) and a conventional emptying product (Tropicalgin; Zhermack SpA). For each product, 10 impressions were made and cast in type III plaster at five different storage times (0, 24, 96, 120 and 168 hours). A three-dimensional model scanner was used to digitize the plaster models and make the corresponding measurements: sum of lengths, dimensional variability, percentage of variability. Results . The five commercial brands presented a greater sum of lengths than the control group (p<0,033). At 0, 24 and 96h Tropicalgin and Hydrogum 5 presented significantly less dimensional variation compared to the master model (p<0,001). The variability percentages ranged from 0.24 to 0.91%. Conclusions. Dimensional stability depends on the product used. Stored correctly, the conventionally cast irreversible hydrocolloid appears not to undergo significant alterations up to 96h, while in the case of Hydrogum 5 it appears to maintain its dimensional stability up to 168h.

14.
Humanidad. med ; 23(3)dic. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1534560

ABSTRACT

Las enfermedades raras son aquellas que tienen baja prevalencia y que, por lo tanto, el desarrollo de medicamentos para tratarlas no es rentable para las empresas farmacéuticas debido a la baja demanda. A pesar de que ya se cuenta con diferentes políticas públicas alrededor del mundo para incentivar a las industrias farmacéuticas a investigar estos medicamentos, conocidos como medicamentos huérfanos, su desarrollo conlleva muchas dificultades en las evaluaciones clínicas y el precio final para el público es muy elevado. Si bien en años recientes se ha planteado el uso de tecnología de impresión en 3D para producir estos medicamentos o incluso recurrir a otros medicamentos previamente aprobados para tratar enfermedades raras, existe un historial de mal uso de las legislaciones por parte de las empresas con el fin de generar beneficios comerciales, por lo que estas políticas deben reforzarse para que cumplan su propósito; ayudar a una población muy vulnerable. El objetivo del presente texto es exponer los resultados de una revisión documental sobre el panorama científico y sociopolítico en el que se encuentra el problema de las enfermedades raras y los medicamentos huérfanos, así como las posibles soluciones que se están desplegando para abordarlo. Deriva de un estudio que se desarrolla en el momento actual en la Universidad Autónoma Metropolitana, de Ciudad de México.


The strange illnesses are those that have low prevalence and that, therefore, the development of medications to treat them is not profitable for the pharmaceutical companies due to the drop demands. Although it is already counted with different political public around the world to motivate to the pharmaceutical industries to investigate these medications, well-known as orphan medications, their development bears many difficulties in the clinical evaluations and the final price for the public it is very high. Although in recent years he/she has thought about the use of impression technology in 3D to produce these medications or even to appeal to other medications previously approved to treat strange illnesses, a record of wrong use of the legislations exists on the part of the companies with the purpose of generating commercial benefits, for what these politicians should be reinforced so that they complete its purpose; to help a very vulnerable population. The objective of the present text is to expose the results of a documental revision on the scientific and sociopolitical panorama in which is the problem of the strange illnesses and the orphan medications, as well as the possible solutions that they are spreading to approach it. It derives of a study that is developed in the current moment in the Metropolitan Autonomous University, of Mexico City.

15.
Odovtos (En línea) ; 25(3): 82-98, Sep.-Dec. 2023. tab, graf
Article in English | LILACS, SaludCR | ID: biblio-1529071

ABSTRACT

Abstract To evaluate the microtensile bond strength (µTBS) of two resin cements to 3D printed and milled CAD/CAM resins used for provisional fixed partial dentures. Blocks (5 x 5 x 5 mm) of three 3D-printed resins (Cosmos3DTemp / Yller; Resilab3D Temp / Wilcos and SmartPrint BioTemp, / MMTech) were printed (Photon, Anycubic Technology Co.). A milled material (VitaCAD-Temp, VITA) was used as control. Half the specimens were sandblasted and the rest were untreated. Two blocks were bonded with the corresponding resin cement: PanaviaV5 (Kuraray Noritake) and RelyX Ultimate (3M Oral Care). After 24 hours, the bonded blocks were sectioned into 1 x 1 mm side sticks. Half the beams were tested for µTBS and the other half was thermocycled (5000 cycles, 30s dwell-time, 5s transfer time) before µTBS testing. A four way Generalized Linear Model (material*sandblasting*cement*aging) analysis was applied. VITA exhibited the lowest µTBS, regardless of the cement, sandblasting and thermocycling. Sandblasting significantly improved the µTBS of VIT, especially after aging, but did not improve the µTBS of 3D printed resins. Sandblasting was not beneficial for 3D printed resins, although is crucial for adhesive cementation of milled temporary resins. Airborne particle abrasion affects the integrity of 3D-printed resins, without producing a benefit on the microtensile bond strength of these materials. However, sandblasting is crucial to achieve a high bond strength on milled temporary resins.


Resumen Evaluar la resistencia adhesiva en microtracción (µTBS) de dos cementos resinosos a resinas CAD/CAM impresas y fresadas indicadas para restauraciones provisionales. Bloques (5 x 5 x 5mm) de tres resinas impresas (Cosmos3DTemp / Yller; Resilab3D Temp / Wilcos and SmartPrint BioTemp, / MMTech) y una resina fresada (VitaCAD-Temp, VITA) fueron fabricados. La mitad de los especímenes fueron arenados y el resto no recibió tratamiento mecánico. Dos bloques con condiciones de tratamiento iguales fueron cementados con cemento resinoso (PanaviaV5 / Kuraray Noritake y RelyX Ultimate / 3M Oral Care). Después de 24 horas los bloques fueron seccionados en palitos de 1 mm² de área. En la mitad de los especímenes se midió la TBS inmediatamente y el resto fue termociclado (5000 ciclos, 30s remojo, 5s transferencia) antes de la prueba de TBS. Se aplica un análisis estadístico por Modelo Linear General con 4 factores (material*arenado*cemento*termociclado). La resina VITA presentó la menor µTBS, independientemente del cemento usado, el arenado y el termociclado. Sin embargo, el arenado aumentó la µTBS de VIT, especialmente después del termociclado. Por otro lado, el arenado no resultó en un aumento significativo de la µTBS de las resinas impresas. El arenado no fue beneficiosos para las resinas impresas, aunque es un paso crucial para la cementación adhesive de las resinas fresadas. El arenado afecta la integridad de las capas de las resinas impresas, sin generar un beneficio en la TBS.


Subject(s)
Computer-Aided Design/instrumentation , Resin Cements/therapeutic use , Dental Cementum , Printing, Three-Dimensional/instrumentation
16.
Rev. cuba. ortop. traumatol ; 37(4)dic. 2023. ilus
Article in Spanish | LILACS, CUMED | ID: biblio-1559945

ABSTRACT

Introducción: Las fracturas complejas de fémur distal AO/AOT tipo 33C3.3 constituyen un reto para los ortopedistas debido a la dificultad de su tratamiento y las complicaciones asociadas. El planeamiento y procedimiento quirúrgicos emplean placas condilares, pero estas se asocian a la pérdida de la fijación y al colapso de la reducción. Objetivo: Describir la planificación preoperatoria de una fractura de fémur distal AO/AOT 33C3.3 con bioimpresión 3D y reconstrucción por computadora. Presentación del caso: Paciente masculino de 34 años con fractura izquierda conminuta del fémur distal, AO/AOT tipo 33C3.3, por un accidente de tránsito. El planeamiento y el tratamiento quirúrgicos se realizaron exitosamente con la impresión y reconstrucción de biomodelos 3D. Basados en las imágenes tomográficas del paciente, se identificaron los principales fragmentos, la secuencia de reducción, la cantidad y la posición de los implantes a utilizar. Conclusiones: La planificación preoperatoria resulta una etapa de vital importancia en el manejo de fracturas complejas. Las técnicas convencionales pueden optimizarse con la cirugía asistida por computadora y reconstrucción con biomodelos 3D impresos. Esta novedosa propuesta permitirá el adecuado uso de materiales, una óptima secuencia de reducción, mejor estabilidad de la fractura y menor riesgo de complicaciones quirúrgicas(AU)


Introduction: Complex distal femur fractures AO/AOT type 33C3.3 constitute a challenge for orthopedists due to the difficulty of their treatment and associated complications. The surgical planning and procedure use condylar plates; but these are associated with loss of fixation and collapse of the reduction. Objective: To describe preoperative planning for an AO/AOT 33C3.3 distal femur fracture with 3D bioprinting and computer reconstruction. Case report: The case of a 34-year-old male patient is reported. He has comminuted left fracture of the distal femur, AO/AOT type 33C3.3, due to a traffic accident. Surgical planning and treatment were successfully performed with 3D biomodel printing and reconstruction. Based on the patient's tomographic images, the main fragments, the reduction sequence, the number and position of the implants to be used were identified. Conclusions: Preoperative planning is a critically important stage in managing complex fractures. Conventional techniques can be optimized with computer-assisted surgery and reconstruction with 3D printed biomodels. This novel proposal will allow the appropriate use of materials, optimal reduction sequence, better stability of the fracture and lower risk of surgical complications(AU)


Subject(s)
Humans , Male , Adult , Accidents, Traffic , Surgery, Computer-Assisted/instrumentation , Femoral Fractures/surgery , Bioprinting/methods , Planning
17.
Rev. Estomat ; 31(2): 1-8, 20230929.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1511309

ABSTRACT

Antecedentes: El conocimiento anatómico de la cámara pulpar y del sistema de conductos radiculareses fundamental para el correcto diagnóstico y planificación del tratamiento en endodoncia. Las herramientas pedagógicasdirigidasa los estudiantes de odontologíacomo apoyo en los procesos formativosde la asignatura de endodoncia favorecen la apropiación del conocimiento e identificación de las variantes morfológicas del sistema de conductos radiculares, que permiten al estudiantela integración del conocimiento. Objetivo:Identificar mediante una revisión de la literatura las estrategias pedagógicas que se utilizan para la enseñanza de morfología del sistema de conductos radiculares en endodoncia. Materiales y métodos: Se realizó una búsqueda bibliográfica de estudios originales en las bases de datos Medline (Pubmed), SciELO, Lilacs, Medline (Ovid), Web of science, Scopus, Embase, Google académico, eligiendo estudios publicadosa partir del año 2010 al 2022, para la selección de los artículos definitivos se seleccionaron estudios concernientes a procesos pedagógicos en endodoncia, excluyendo así otros tipos de enfoques en el área de odontología. Resultados: Se identificaron un total de 63 referencias, los cuales fueron analizados y seleccionados16, siendo excluidos 47 por no cumplir los criterios de inclusión. Conclusión: El uso de herramientas pedagógicas virtuales, didácticas y tecnológicas propician un efecto positivo en el estudiante de pregrado de odontología durante el aprendizaje de anatomía de sistemas de conductos radiculares que aumentan la confianza y seguridad al momento de realizar un tratamiento endodóntico en pacientes


Background: Anatomical knowledge of the pulp chamber and the root canal system is essential for correct diagnosis and treatment planning in endodontics. The pedagogical tools aimed at dental students as support in the training processes of the endodontics subject favor the appropriation of knowledge and identification of the morphological variants of the root canal system, which allow the student the integration of knowledge. Objective: To identify, through a review of the literature, the pedagogical strategies used to teach morphology of the root canal system in endodontics. Materials and methods: A bibliographic search of original studies was carried out in the Medline (Pubmed), SciELO, Lilacs, Medline (Ovid), Web of Science, Scopus, Embase, and Google academic databases, choosing studies published from 2010 to 2022. , for the selection of the definitive articles, studies concerning pedagogical processes in endodontics were selected, thus excluding other types of approaches in the area of dentistry. Results: A total of 63 references were identified, 16 of which were analyzed and selected, 47 being excluded for not meeting the inclusion criteria. Conclusion: The use of virtual, didactic and technological pedagogical tools favor a positive effect on the dentistry undergraduate student while learning the anatomy of root canal systems that increase confidence and security when performing endodontic treatment in patients.

18.
Article in English | LILACS-Express | LILACS | ID: biblio-1559934

ABSTRACT

The use of 3-Dimensional (3D) printing in orthopaedics keeps pace with technical advancements. However, due to its novelty, few research have examined its application. Therefore, our study aimed to assess the utility of 3D printing in orthopaedics use. We conducted a systematic review study during the period of April-May. Article search was conducted in Google Scholar, National Center for Biotechnology Information, Clinical Key, Pubmed, and Science Direct. We included five publications with a total of 99 patients. Our findings indicate that the orthopaedic application and utilization of 3D printing technologies are expanding. Despite the relative paucity of evidence, these findings suggest the utility of 3D printing technology in a variety of intraoperative deformity correction applications.


El uso de la impresión tridimensional (3D) en ortopedia sigue el ritmo de los avances técnicos. Sin embargo, debido a su novedad, pocas investigaciones han examinado su aplicación. Por lo tanto, el estudio tuvo como objetivo evaluar la utilidad de la impresión 3D en el uso ortopédico. Se realizó un estudio de revisión sistemática durante el período de abril a mayo. La búsqueda de artículos se realizó en Google Scholar, National Center for Biotechnology Information, Clinical Key, Pubmed y Science Direct. Se incluyeron cinco publicaciones con un total de 99 pacientes. Nuestros hallazgos indican que actualmente se expanden la aplicación ortopédica y la utilización de las tecnologías de impresión 3D. A pesar de la relativa escasez de evidencia, estos hallazgos sugieren la utilidad de la tecnología de impresión 3D en una variedad de aplicaciones de corrección de las deformidades intraoperatorias.

19.
Odovtos (En línea) ; 25(2)ago. 2023.
Article in English | LILACS-Express | LILACS | ID: biblio-1448737

ABSTRACT

The objective is to determine which biopolymer has the best 3D printing characteristics and mechanical properties for the manufacture of a bioscaffold, using the fused deposition printing technique, with models generated from an STL file obtained from a Micro-CT scan taken from a bovine iliac crest bone structure. Through an experimental exploratory study, three study groups of the analyzed biopolymers were carried out with thirteen printed structures of each one. The first is made of 100% PLA. The second, 90B, we added 1g of diatom extract, and the third, 88C, differs from the previous one in that it also contains 1g of calcium phosphate. The 39 printed structures underwent a visual inspection test, which required the fabrication of a gold standard scaffold in resin, with greater detail and similarity to the scanned bone structure. Finally, the structures were subjected to a compressive force (N) to obtain the modulus of elasticity (MPa) and compressive strength (MPa) of each one of them. A statistically significant difference (p=0.001) was obtained in the printing properties of the biomaterial 88C, compared to 90B and pure PLA and the 88C presented the best 3D printing characteristics. In addition, it also presented the best mechanical properties compared to the other groups of materials. Although the difference between these was not statistically significant (p=0.388), in the structures of the 88C biomaterial, values of compressive strength (8,84692 MPa) and modulus of elasticity (43,23615 MPa) were similar to those of cancellous bone in the jaws could be observed. Because of this result, the 88C biomaterial has the potential to be used in the manufacture of bioscaffolds in tissue engineering.


El objetivo es determinar cuál biopolímero presenta las mejores características de impresión 3D y propiedades mecánicas para la fabricación de un bioandamiaje, utilizando la técnica de impresión por deposición fundida, con modelos generados a partir de un archivo en formato STL que se obtuvo de un Micro-CT Scan de una estructura osea de cresta iliaca bovina. Mediante un estudio exploratorio, se realizaron 3 grupos de estudio con trece estructuras impresas de cada uno. El primero, se compone 100% de PLA. El segundo, 90B, se le agrega 1g de extracto de diatomea, y el tercero, 88C, se diferencia del anterior ya que contiene además, 1g de fosfato de calcio. A las 39 estructuras impresas se les realizó una prueba de inspección visual, por lo que se requirió la confección de un patrón de oro en resina, con mayor detalle y similitud a la estructura ósea escaneada. Finalmente, las estructuras fueron sometidas a una fuerza compresiva (N) para la obtención del módulo de elasticidad (MPa) y de la resistencia compresiva (MPa) de cada una de ellas. Se obtuvo una diferencia estadísticamente significativa (p=0,001) en las propiedades de impresión del biomaterial 88C, con respecto al 90B y al PLA puro, presentando las mejores características de impresión 3D. Además, obtuvo las mejores propiedades mecánicas en comparación con los otros grupos de materiales. Aunque la diferencia entre estos no fue estadísticamente significativa (p=0,388), en las estructuras del biomaterial 88C, se pudieron observar valores de resistencia compresiva (8,84692 MPa) y módulo de elasticidad (43,23615 MPa) que son semejantes a los del hueso esponjoso de los maxilares. A razón de este resultado, el biomaterial 88C cuenta con el potencial para ser utilizado en la fabricación de bioandamiajes en la ingeniería tisular.

20.
Rev. cir. traumatol. buco-maxilo-fac ; 23(4): 33-37, out.-dez. 2023. ilus
Article in Portuguese | LILACS, BBO - Dentistry | ID: biblio-1561420

ABSTRACT

Objetivo: Discorrer sobre o tratamento cirúrgico de uma fratura idiopática de mandíbula atrófica. Relato de caso: Idosa compareceu à emergência de um hospital referência em traumas na Paraíba relatando dificuldade ao se alimentar, impossibilidade de uso da prótese dentaria, sintomatologia dolorosa em região mandibular direita com processo infeccioso ativo, sem histórico de trauma direto em face. Ao exame tomográfico constatou-se fratura em mandíbula atrófica com presença de dente incluso na região. Diante do quadro, optou-se por iniciar antibioticoterapia empírica e planejou-se tratamento cirúrgico de reconstrução mandibular com sistema load-sharing, tendo auxílio de biomodelo para conformação prévia da placa. Conclusão: O correto planejamento e escolha do sistema de fixação são fundamentais para o sucesso do tratamento. O uso de biomodelo com pré modelagem de placa mostrou-se positivo por otimizar o tempo cirúrgico, reduzindo os riscos inerentes ao procedimento nesta faixa etária e a utilização de sistema capaz de suportar a carga sofrida na estrutura óssea comprometida nestes casos é mandatório... (AU)


Objective: to discuss the surgical treatment of an idiopathic fracture of the atrophic mandible. Case report: elderly woman attended the emergency department of the Emergency and Trauma Hospital Dom Luiz Gonzaga Fernandes, in Campina Grande, Brazil. The patient reported pain on eating and inability to use her denture as painful symptoms in the right mandibular region with active fistula, without any records of facial trauma. Tomographic examination revealed an atrophic mandibular fracture with an impacted tooth in the region. The following procedures were performed: antibiotic therapy, surgical fixation using a 2.4mm pre-molded plate, shaped using a biomodel, and fistulectomy. Conclusion: Thus, to plan accordingly aiming to minimize the surgical time and its associate damage and the use of appropriate fixation systems capable of supporting the load on the compromised bone are essential to a successful treatment, specially with elderly patients due their general health condition and preexistent comorbities... (AU)


Objetivo: Discutir sobre el tratamiento quirúrgico de una fractura idiopática de la mandíbula atrófica. Caso clínico: Anciana compareció al servicio de urgencias del Hospital de Emergencia y Trauma de Campina Grande Dom Luiz Gonzaga Fernandes, PB, relatando dificultad para alimentarse, imposibilidad de uso de prótesis dental, sintomatología dolorosa en la región mandibular derecha con fístula activa, sin antecedentes de traumatismo directo en la cara. El examen tomográfico presentó una fractura mandibular atrófica con presencia de un diente incluido en la región. Como resultado se realizó antibioticoterapia, procedimiento de fijación quirúrgica con una placa de 2,4 mm premoldeada en biomodelo y fistulectomía. Conclusión: De esta forma, el correcto planeamiento para minimizar el tiempo quirúrgico y los daños asociados, principalmente en los ancianos por su estado general de salud y comorbilidades preexistentes, la utilización de sistemas de fijación adecuados capaces de soportar la carga sufrida en los huesos comprometidos, es fundamental para el éxito del tratamiento... (AU)


Subject(s)
Humans , Female , Aged , Fracture Fixation, Internal , Mandible/surgery , Tooth, Unerupted/complications , Antibiotic Prophylaxis
SELECTION OF CITATIONS
SEARCH DETAIL