Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
J Chromatogr A ; 1730: 465098, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38901295

ABSTRACT

The epoxy propanol molecular cage bonded silica stationary phase, RCC3-GLD@silica, synthesized through the ring-opening reaction of secondary amine with epoxy propanol using RCC3-R as the scaffold unit, was successfully prepared as confirmed by infrared spectroscopy, thermogravimetric analysis, and nitrogen adsorption-desorption characterization. This stationary phase demonstrated excellent separation performance in both reversed-phase and hydrophilic chromatography modes, effectively separating a wide variety of compounds including alkylbenzenes, polycyclic aromatic hydrocarbons, phenols, anilines, sulfonamides, nucleosides, amino acids, sugars, and acids. The development of RCC3-GLD@silica benefits from the synergistic effects of its hydrophobic and hydrophilic actions, as evidenced by the U-shaped characteristic of the retention factor for nucleoside compounds with changes in the aqueous content of the mobile phase, further confirming the simultaneous presence of reversed-phase and hydrophilic chromatography mechanisms. Not only did this stationary phase successfully separate 33 compounds in reversed-phase chromatography mode, but it also separated 54 compounds in hydrophilic interaction chromatography mode, showcasing its broad separation capability from weakly polar to strongly polar compounds on a single chromatographic column. This indicates a wide application prospect in the field of chromatographic analysis.

2.
Front Cardiovasc Med ; 10: 1280899, 2023.
Article in English | MEDLINE | ID: mdl-38045918

ABSTRACT

Background: Central blood pressure (cBP) is a better indicator of cardiovascular morbidity and mortality than peripheral BP (pBP). However, direct cBP measurement requires invasive techniques and indirect cBP measurement is based on rigid and empirical transfer functions applied to pBP. Thus, development of a personalized and well-validated method for non-invasive derivation of cBP from pBP is necessary to facilitate the clinical routine. The purpose of the present study was to develop a novel blind source separation tool to separate a single recording of pBP into their pressure waveforms composing its dynamics, to identify the compounds that lead to pressure waveform distortion at the periphery, and to estimate the cBP. The approach is patient-specific and extracts the underlying blind pressure waveforms in pBP without additional brachial cuff calibration or any a priori assumption on the arterial model. Methods: The intra-arterial femoral BPfe and intra-aortic pressure BPao were anonymized digital recordings from previous routine cardiac catheterizations of eight patients at the German Heart Centre Berlin. The underlying pressure waveforms in BPfe were extracted by the single-channel independent component analysis (SCICA). The accuracy of the SCICA model to estimate the whole cBP waveform was evaluated by the mean absolute error (MAE), the root mean square error (RMSE), the relative RMSE (RRMSE), and the intraclass correlation coefficient (ICC). The agreement between the intra-aortic and estimated parameters including systolic (SBP), diastolic (DBP), mean arterial pressure (MAP), and pulse pressure (PP) was evaluated by the regression and Bland-Altman analyses. Results: The SCICA tool estimated the cBP waveform non-invasively from the intra-arterial BPfe with an MAE of 0.159 ± 1.629, an RMSE of 5.153 ± 0.957 mmHg, an RRMSE of 5.424 ± 1.304%, and an ICC of 0.94, as well as two waveforms contributing to morphological distortion at the femoral artery. The regression analysis showed a strong linear trend between the estimated and intra-aortic SBP, DBP, MAP, and PP with high coefficient of determination R2 of 0.98, 0.99, 0.99, and 0.97 respectively. The Bland-Altman plots demonstrated good agreement between estimated and intra-aortic parameters with a mean error and a standard deviation of difference of -0.54 ± 2.42 mmHg [95% confidence interval (CI): -5.28 to 4.20] for SBP, -1.97 ± 1.62 mmHg (95% CI: -5.14 to 1.20) for DBP, -1.49 ± 1.40 mmHg (95% CI: -4.25 to 1.26) for MAP, and 1.43 ± 2.79 mmHg (95% CI: -4.03 to 6.90) for PP. Conclusions: The SCICA approach is a powerful tool that identifies sources contributing to morphological distortion at peripheral arteries and estimates cBP.

3.
Physiol Rep ; 11(11): e15731, 2023 06.
Article in English | MEDLINE | ID: mdl-37269177

ABSTRACT

Pulsatile hemodynamics analyses provide important information about the ventricular-arterial system which cannot be inferred by standard blood pressure measurements. Pulse wave analysis (PWA), wave separation analysis (WSA), and wave power analysis (WPA) characterize arterial hemodynamics with limited preclinical applications. Integrating these tools into preclinical testing may enhance understanding of disease or therapeutic effects on cardiovascular function. We used a canine rapid ventricular pacing (RVP) heart failure model to: (1) Characterize hemodynamics in response to RVP and (2) assess analyses from flow waveforms synthesized from pressure compared to those derived from measured flow. Female canines (n = 7) were instrumented with thoracic aortic pressure transducers, ventricular pacing leads, and an ascending aortic flow probe. Data were collected at baseline, 1 week, and 1 month after RVP onset. RVP progressively reduced stroke volume (SV), the PWA SV estimator, and WSA and WPA pulsatility and wave reflection indices. Indices derived from synthesized flow exhibited similar directional changes and high concordance with measured flow calculations. Our data demonstrate the value of analytical hemodynamic methods to gain deeper insight into cardiovascular function in preclinical models. These approaches can provide complementary value to standard endpoints in evaluating potential effects of pharmaceutical agents intended for human use.


Subject(s)
Heart Failure , Hemodynamics , Animals , Female , Dogs , Humans , Hemodynamics/physiology , Arteries/physiology , Aorta , Heart , Computer Simulation , Blood Pressure/physiology , Pulsatile Flow/physiology , Pulse Wave Analysis/methods
4.
Zhongguo Zhong Yao Za Zhi ; 48(5): 1194-1202, 2023 Mar.
Article in Chinese | MEDLINE | ID: mdl-37005803

ABSTRACT

Ionic liquids(ILs) are salts composed entirely of anions and cations in a liquid state at or near room temperature, which have a variety of good physicochemical properties such as low volatility and high stability. This paper mainly reviewed the research overview of ILs in the application of traditional Chinese medicine(TCM) volatile oil preparation technology. Firstly, it briefly introduced the application of TCM volatile oil preparation technology and composition classification and physicochemical properties of ILs, and then summarized the application of ILs in the extraction, separation, analysis, and preparation of TCM volatile oil. Finally, the problems and challenges of ILs in the application of TCM volatile oil were explained, and the application of ILs in TCM volatile oil in the future was prospected.


Subject(s)
Biological Products , Ionic Liquids , Oils, Volatile , Cations , Ionic Liquids/chemistry , Medicine, Chinese Traditional , Oils, Volatile/analysis , Technology
5.
Front Physiol ; 14: 1097879, 2023.
Article in English | MEDLINE | ID: mdl-36909238

ABSTRACT

Pulse wave reflections reflect cardiac afterload and perfusion, which yield valid indicators for monitoring cardiovascular status. Accurate quantification of pressure wave reflections requires the measurement of aortic flow wave. However, direct flow measurement involves extra equipment and well-trained operator. In this study, the personalized aortic flow waveform was estimated from the individual central aortic pressure waveform (CAPW) based on pressure-flow relations. The separated forward and backward pressure waves were used to calculate wave reflection indices such as reflection index (RI) and reflection magnitude (RM), as well as the central aortic pulse transit time (PTT). The effectiveness and feasibility of the method were validated by a set of clinical data (13 participants) and the Nektar1D Pulse Wave Database (4,374 subjects). The performance of the proposed personalized flow waveform method was compared with the traditional triangular flow waveform method and the recently proposed lognormal flow waveform method by statistical analyses. Results show that the root mean square error calculated by the personalized flow waveform approach is smaller than that of the typical triangular and lognormal flow methods, and the correlation coefficient with the measured flow waveform is higher. The estimated personalized flow waveform based on the characteristics of the CAPW can estimate wave reflection indices more accurately than the other two methods. The proposed personalized flow waveform method can be potentially used as a convenient alternative for the measurement of aortic flow waveform.

6.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-970590

ABSTRACT

Ionic liquids(ILs) are salts composed entirely of anions and cations in a liquid state at or near room temperature, which have a variety of good physicochemical properties such as low volatility and high stability. This paper mainly reviewed the research overview of ILs in the application of traditional Chinese medicine(TCM) volatile oil preparation technology. Firstly, it briefly introduced the application of TCM volatile oil preparation technology and composition classification and physicochemical properties of ILs, and then summarized the application of ILs in the extraction, separation, analysis, and preparation of TCM volatile oil. Finally, the problems and challenges of ILs in the application of TCM volatile oil were explained, and the application of ILs in TCM volatile oil in the future was prospected.


Subject(s)
Ionic Liquids/chemistry , Oils, Volatile/analysis , Medicine, Chinese Traditional , Cations , Biological Products , Technology
7.
Front Cardiovasc Med ; 9: 997452, 2022.
Article in English | MEDLINE | ID: mdl-36386340

ABSTRACT

Background: Increased wave reflections assessed by pulse wave analysis (PWA) was proposed as one of the potential culprits of hypertension seen in women with pregnancy-associated hypertension (PAH). However, this statement has never been confirmed with "Wave Separation Analysis" (WSA), a more sophisticated mathematical approach that analyzes the amplitude and interaction between forward and backward aortic pressure waveform components. Objective: To characterize potential changes in pressure wave components of PAH compared to healthy non-pregnant (NP) women and women with normal pregnancies (HP) by using WSA and compared these findings with PWA-derived indexes; secondarily, to evaluate differences in WSA-derived indexes between subgroups of PAH (i.e., preeclampsia [PE] and gestational hypertension [GH]). Methods: Using radial and carotid applanation tonometry, we quantified in HP (n = 10), PAH (n = 16), and NP (n = 401): (i) PWA-derived indexes; (ii) WSA-derived indexes: forward (Pf) and backward (Pb) waveform components, backward component arrival time (PbAT), reflection magnitude (RM = Pb/Pf) and index [RIx = Pb/(Pf + Pb)]. Results: While PAH was associated with a higher Pf compared to HP and NP, Pb and PbAT were similar between the groups. Both GH and PE showed a higher Pf compared to HP, but only PE had a trend of presenting with higher Pb and lower PbAT compared to the other groups. Finally, PAH showed a trend of having lower RM and RIx compared to NP and HP, with no differences between GH and PE. Conclusion: PAH was associated with higher Pf, but not higher Pb, compared to NP and HP, although PE also demonstrated a trend of higher Pb.

8.
J Am Heart Assoc ; 11(17): e026603, 2022 09 06.
Article in English | MEDLINE | ID: mdl-36056725

ABSTRACT

Background Waveform parameters provide approximate data about aortic wave reflection. However, their association with cardiovascular events remains controversial and their role in cardiovascular prediction is unknown. Methods and Results We analyzed participants aged between 40 and 69 from the population-based CARTaGENE cohort. Baseline pulse wave analysis (central pulse pressure, augmentation index) and wave separation analysis (forward pressure, backward pressure, reflection magnitude) parameters were derived from radial artery tonometry. Associations between each parameter and major adverse atherosclerotic events (MACE; cardiovascular death, stroke, myocardial infarction) were obtained using adjusted Cox models. The incremental predictive value of each parameter compared with the 10-year atherosclerotic cardiovascular disease score alone was assessed using hazard ratios, c-index differences, continuous net reclassification indexes, and integrated discrimination indexes. From 17 561 eligible patients, 2315 patients had a MACE during a median follow-up of 10.1 years. Central pulse pressure, forward pressure, and backward pressure, but not augmentation index and reflection magnitude, were significantly associated with MACE after full adjustment. All parameters except forward pressure statistically improved MACE prediction compared with the atherosclerotic cardiovascular disease score alone. The greatest prediction improvement was seen with augmentation index and reflection magnitude but remained small in magnitude. These 2 parameters enhanced predictive performance more strongly in patients with low baseline atherosclerotic cardiovascular disease scores. Up to 5.7% of individuals were reclassified into a different risk stratum by adding waveform parameters to atherosclerotic cardiovascular disease scores. Conclusions Some waveform parameters are independently associated with MACEs in a population-based cohort. Augmentation index and reflection magnitude slightly improve risk prediction, especially in patients at low cardiovascular risk.


Subject(s)
Atherosclerosis , Cardiovascular Diseases , Myocardial Infarction , Adult , Aged , Aorta , Blood Pressure , Cardiovascular Diseases/diagnosis , Cardiovascular Diseases/epidemiology , Humans , Middle Aged , Pulse Wave Analysis/methods , Radial Artery
9.
Physiol Meas ; 43(5)2022 05 31.
Article in English | MEDLINE | ID: mdl-35537402

ABSTRACT

Objective.Methods for separating the forward-backward components from blood pulse waves rely on simultaneously measured pressure and flow velocity from a target artery site. Modelling approaches for flow velocity simplify the wave separation analysis (WSA), providing a methodological and instrumentational advantage over the former; however, current methods are limited to the aortic site. In this work, a multi-Gaussian decomposition (MGD) modelled WSA (MGDWSA) is developed for a non-aortic site such as the carotid artery. While the model is an adaptation of the existing wave separation theory, it does not rely on the information of measured or modelled flow velocity.Approach.The proposed model decomposes the arterial pressure waveform using weighted and shifted multi-Gaussians, which are then uniquely combined to yield the forward (PF(t)) and backward (PB(t)) pressure wave. A study using the database of healthy (virtual) subjects was used to evaluate the performance of MGDWSAat the carotid artery and was compared against reference flow-based WSA methods.Main results.The MGD modelled pressure waveform yielded a root-mean-square error (RMSE) < 0.35 mmHg. Reliable forward-backward components with a group average RMSE <2.5 mmHg forPF(t) andPB(t) were obtained. When compared with the reference counterparts, the pulse pressures (ΔPFand ΔPB), as well as reflection quantification indices, showed a statistically significant strong correlation (r > 0.96,p < 0.0001) and (r > 0.83,p < 0.0001) respectively, with an insignificant (p > 0.05) bias.Significance.This study reports WSA for carotid pressure waveforms without assumptions on flow conditions. The proposed method has the potential to adapt and widen the vascular health assessment techniques incorporating pulse wave dynamics.


Subject(s)
Arterial Pressure , Pulse Wave Analysis , Aorta , Blood Pressure , Carotid Arteries , Humans , Pulse Wave Analysis/methods
10.
Comput Methods Programs Biomed ; 219: 106781, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35378395

ABSTRACT

BACKGROUND AND OBJECTIVE: Arterial stiffness, commonly assessed by carotid-femoral pulse wave velocity (cfPWV), is an independent biomarker for cardiovascular disease. The measurement of cfPWV, however, has been considered impractical for routine clinical application. Pulse wave analysis using a single pulse wave measurement in the radial artery is a convenient alternative. This study aims to identify pulse wave features for a more accurate estimation of cfPWV from a single radial pulse wave measurement. METHODS: From a dataset of 140 subjects, cfPWV was measured and the radial pulse waveform was recorded for 30 s twice in succession. Features were extracted from the waveforms in the time and frequency domains, as well as by wave separation analysis. All-possible regressions with bootstrapping, McHenry's select algorithm, and support vector regression were applied to compute models for cfPWV estimation. RESULTS: The correlation coefficients between the measured and estimated cfPWV were r = 0.81, r = 0.81, and r = 0.8 for all-possible regressions, McHenry's select algorithm, and support vector regression, respectively. The features selected by all-possible regressions are physiologically interpretable. In particular, the amplitude ratio of the diastolic peak to the notch of the radial pulse waveform (Rn,dr,P) is shown to be correlated with cfPWV. This correlation was further evaluated and found to be independent of wave reflections using a dataset (n = 3,325) of simulated pulse waves. CONCLUSIONS: The proposed method may serve as a convenient surrogate for the measurement of cfPWV. Rn,dr,P is associated with aortic pulse wave velocity and this association may not be dependent on wave reflection.


Subject(s)
Pulse Wave Analysis , Radial Artery , Blood Pressure , Carotid Arteries/physiology , Carotid-Femoral Pulse Wave Velocity , Humans , Pulse Wave Analysis/methods
11.
Ultramicroscopy ; 232: 113404, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34656896

ABSTRACT

Structural distortions frequently occur in materials, either periodically (ferroelectric or antiferroelectric) or in local areas (domain boundaries, surfaces/interfaces, dislocations). Measuring atomic displacements from an average lattice is of crucial importance for analyzing structural distortions and their connections to physical properties. Conventionally, the displacements are measured atom-by-atom by fitting atomic-resolution images with two-dimensional gaussian functions. Here, we exhibit an efficient method, named Displacement Separation Analysis, DSA in short, to directly separate atomic displacements from an average lattice based on Fourier space filtering. Using antiferroelectric AgNbO3 as a model system, we demonstrate the consistence between DSA and gaussian fitting. The suppression of polarization at interfacial region of h-LuFeO3/α-Al2O3 heterostructure and the emergence of modulation structure in LuFe2O4+x is then revealed using DSA, attesting the implication of DSA in unveiling structural distortions either locally or periodically. Inspired by the simple principle of DSA, such method can be used for any atomic-resolution images, including TEM, STM, and AFM images to exhibit the atomic displacement intuitively.

12.
Front Vet Sci ; 8: 773035, 2021.
Article in English | MEDLINE | ID: mdl-34926644

ABSTRACT

Background: Pulmonary arterial wave reflection provides novel information about pulmonary artery hemodynamics in pulmonary hypertension (PH). PH is common in dogs with myxomatous mitral valve disease (MMVD), though research examining the relationship between pulmonary arterial wave reflection and MMVD with PH is lacking. Hypothesis/Objective: This study investigated conventional echocardiographic parameters and pulmonary artery wave reflection parameters before and after mitral valvuloplasty in canine patients with PH due to MMVD. The parameters were backward pressure (Pb), forward pressure (Pf), and the reflection coefficient calculated as the ratio of peak Pb to peak Pf (RC). Animals: The study subjects were 10 client-owned dogs receiving mitral valvuloplasty for MMVD with PH. Methods: Conventional echocardiographic parameters and pulmonary artery wave reflection parameters were measured before and after mitral valvuloplasty. The relationships between pulmonary artery wave reflection parameters and echocardiographic parameters, estimation of pulmonary artery systolic pressure, and right atrium pressure (RAP) gained by catheter in mitral valvuloplasty were also investigated. Post-operative echocardiography and the measurement of pulmonary arterial wave reflection were performed 2 weeks after mitral valvuloplasty. Results: The parameters of normalized left ventricular internal diameter at end-diastole (LVIDDN), E velocity, and the estimation of pulmonary artery systolic pressure were significantly reduced post-operatively compared with baseline measurements (p < 0.05). Post-operative Pb decreased significantly compared with pre-operative measurements (8.8 ± 5.9 to 5.0 ± 3.2 mmHg, p = 0.037) as did RC (0.37 ± 0.15 to 0.22 ± 0.11, p < 0.01). A statistically significant positive correlation existed between wave reflection parameters and RAP, an estimation of pulmonary artery systolic pressure. Conclusions: Results demonstrate that mitral valvuloplasty can be used to treat secondary PH caused by MMVD, resulting in the improvement of post-operative echocardiographic and wave reflection parameters and a decrease in the right afterload. In some patients, some degree of vascular admittance mismatch persisted, despite the improvement of left atrial pressure. This may be indicative of residual pulmonary arterial disease, which may continue to adversely affect interactions between the right ventricle and the vasculature.

13.
Front Physiol ; 12: 752550, 2021.
Article in English | MEDLINE | ID: mdl-34955877

ABSTRACT

Background: Pulmonary arterial (PA) wave reflection provides additional information for assessing right ventricular afterload, but its applications is hampered by the need for invasive pressure and flow measurements. We tested the hypothesis that PA pressure and flow waveforms estimated by Doppler echocardiography could be used to quantify PA wave reflection. Methods: Doppler echocardiographic images of tricuspid regurgitation and right ventricular outflow tract flow used to estimate PA pressure and flow waveforms were acquired simultaneously with direct measurements with a dual sensor-tipped catheter under various hemodynamic conditions in a canine model of pulmonary hypertension (n = 8). Wave separation analysis was performed on echo-Doppler derived as well as catheter derived waveforms to separate PA pressure into forward (Pf) and backward (Pb) pressures and derive wave reflection coefficient (RC) defined as the ratio of peak Pb to peak Pf. Results: Wave reflection indices by echo-Doppler agreed well with corresponding indices by catheter (Pb: mean difference = 0.4 mmHg, 95% limits of agreement = -4.3 to 5.0 mmHg; RC: bias = 0.13, 95% limits of agreement = -0.25 to 0.26). RC correlated negatively with PA compliance. Conclusion: This echo-Doppler method yields reasonable measurement of reflected wave in the pulmonary circulation, paving the way to a more integrative assessment of pulmonary hemodynamics in the clinical setting.

14.
Front Physiol ; 12: 701154, 2021.
Article in English | MEDLINE | ID: mdl-34381376

ABSTRACT

Aortic compliance is an important determinant of cardiac afterload and a contributor to cardiovascular morbidity. In the present study, we sought to provide in silico insights into the acute as well as long-term effects of aortic compliance decrease on central hemodynamics. To that aim, we used a mathematical model of the cardiovascular system to simulate the hemodynamics (a) of a healthy young adult (baseline), (b) acutely after banding of the proximal aorta, (c) after the heart remodeled itself to match the increased afterload. The simulated pressure and flow waves were used for subsequent wave separation analysis. Aortic banding induced hypertension (SBP 106 mmHg at baseline versus 152 mmHg after banding), which was sustained after left ventricular (LV) remodeling. The main mechanism that drove hypertension was the enhancement of the forward wave, which became even more significant after LV remodeling (forward amplitude 30 mmHg at baseline versus 60 mmHg acutely after banding versus 64 mmHg after remodeling). Accordingly, the forward wave's contribution to the total pulse pressure increased throughout this process, while the reflection coefficient acutely decreased and then remained roughly constant. Finally, LV remodeling was accompanied by a decrease in augmentation index (AIx 13% acutely after banding versus -3% after remodeling) and a change of the central pressure wave phenotype from the characteristic Type A ("old") to Type C ("young") phenotype. These findings provide valuable insights into the mechanisms of hypertension and provoke us to reconsider our understanding of AIx as a solely arterial parameter.

15.
Front Vet Sci ; 8: 659194, 2021.
Article in English | MEDLINE | ID: mdl-34307519

ABSTRACT

Background: Pulmonary arterial wave reflection (PAWR) occurs when the forward blood flow out the right ventricle is reflected by the pulmonary arterial tree, generating a backward wave. PAWR assessed by cardiac catheterization has been used to obtain information regarding pulmonary artery hemodynamics in pulmonary hypertension (PH) in people. However, diagnostic cardiac catheterization is not commonly used in small animal medicine because it is invasive and requires anesthesia. Hypothesis/Objective: To investigate whether PAWR can be assessed non-invasively in dogs with suspected PH using Doppler echocardiography, based on wave intensity analysis (WIA). In addition, the method was validated in a dog model of acute pulmonary embolism. Animals: Fifty-one client-owned dogs with tricuspid valve regurgitation were included in the clinical study (35 with suspected PH and 16 without echocardiographic evidence of PH) and eight healthy beagle dogs were included in the validation study. Methods: PAWR was assessed by separating pulmonary artery pulse pressure waveforms, which were estimated from the flow profile of tricuspid regurgitation, into forward (Pf) and backward pressures (Pb) using WIA. Reflection coefficient (RC) was defined as the ratio of peak Pb to peak Pf. We investigated the relationships between RC, cause, and survival time in dogs with suspected PH. In addition, we performed a validation study to compare PAWR obtained by cardiac catheterization and PAWR by Doppler echocardiography in dogs with experimentally-induced PH. Results: RC was significantly higher in dogs with suspected PH than in dogs without echocardiographic evidence of PH (0.18 ± 0.13 vs. 0.59 ± 0.21, P < 0.001). A characteristic reflected waveform appeared depending on the cause of PH. Kaplan-Meier survival curves showed that dogs with RC > 0.48 had a significantly shorter survival time than dogs with RC <0.48 (x2 = 9.8, log-rank test, p = 0.0018, median survival time 353 days vs. 110 days). In the validation study, RC obtained by Doppler echocardiography was significantly correlated with RC obtained by cardiac catheterization (r = 0.81, P < 0.001). Conclusions: PAWR analysis performed by echocardiography seems feasible in dogs and could provide useful information for classification and prognosis in canine PH.

16.
Exp Physiol ; 106(8): 1720-1730, 2021 08.
Article in English | MEDLINE | ID: mdl-33999464

ABSTRACT

NEW FINDINGS: What is the central question of this study? There is a paradoxical reduction in augmentation index during lower-body dynamic (LBD) exercise in the face of an increase in central pressure. To determine causality, the amplitudes of forward and backward pressure waves were assessed separately using wave separation analysis. What is the main finding and its importance? Reflection magnitude decreased during LBD exercise in healthy young adults and was attributable to an increased forward pressure wave amplitude and decreased backward pressure wave amplitude. This vasoactive response might limit the adverse effects of wave reflection during LBD exercise, optimizing ventricular-arterial interactions. ABSTRACT: Acute lower-body dynamic (LBD) exercise decreases surrogate measures of wave reflection, such as the augmentation index. However, the augmentation index is influenced by the combined effects of wave reflection timing, magnitude and other confounding factors external to wave reflection, which make it difficult to discern the origin of changes in surrogate measures. The relative contributions of forward (Pf) and backward (Pb) pressure wave amplitudes to central pressure can be determined by wave separation analysis. Reflection magnitude (RM = Pb/Pf) and the timing of apparent wave reflection return can also be determined. We tested the hypothesis that acute LBD exercise decreases RM and reflected wave transit time (RWTT). Applanation tonometry was used to record radial artery pressure waveforms in 25 adults (24 ± 4 years of age) at baseline and during light-, moderate- and vigorous-intensity exercise. Wave separation analysis was conducted offline using a personalized physiological flow wave to determine Pf, Pb, RM and RWTT. The RM decreased during all intensities of exercise compared with baseline (all P < 0.001; baseline, 43 ± 5%; light, 33 ± 6%; moderate, 23 ± 7%; vigorous, 17 ± 5%). The reduction in RM was attributable to the combined effect of increased Pf and decreased Pb during exercise. The RWTT decreased during all intensities of exercise compared with baseline (all P < 0.04; baseline, 156 ± 17 ms; light, 144 ± 15 ms; moderate, 129 ± 16 ms; vigorous, 121 ± 17 ms). Lastly, in a stepwise multilinear regression, Pf, but not Pb and RWTT, contributed to increased central pulse pressure during LBD exercise. These data show that wave reflection decreased and that central pulse pressure is most influenced by Pf during LBD exercise.


Subject(s)
Arteries , Exercise , Blood Pressure/physiology , Heart Rate , Heart Ventricles , Humans , Young Adult
17.
Am J Physiol Heart Circ Physiol ; 320(5): H1802-H1812, 2021 05 01.
Article in English | MEDLINE | ID: mdl-33710924

ABSTRACT

Central aortic pressure waveforms contain valuable prognostic information in addition to central systolic pressure. Using pressure-flow relations, wave separation analysis can be used to decompose aortic pressure waveforms into forward- (Pf) and backward-traveling (Pb) components. Reflection magnitude, the ratio of pressure amplitudes (RM = Pb/Pf), is a predictor of heart failure and all-cause mortality. Aortic flow can be measured via Doppler echocardiography or estimated using a triangular flow waveform; however, the latter may underestimate the flow waveform convexity and overestimate Pb and RM. We sought to determine the accuracy of a personalized synthetic physiologic flow waveform, compared with triangular and measured flow waveforms, for estimating wave reflection indices in 49 healthy young (27 ± 6 yr) and 29 older adults [66 ± 6 yr; 20 healthy, 9 chronic kidney disease (CKD)]. Aortic pressure and measured flow waveforms were acquired via radial tonometry and echocardiography, respectively. Triangular and physiologic flow waveforms were constructed from aortic pressure waveforms. Compared with the measured flow waveform, the triangular waveform underestimated Pf in older, but not young, adults and overestimated Pb and RM in both groups. The physiologic waveform was equivalent to measured flow in deriving all wave reflection indices and yielded smaller mean absolute biases than the triangular waveform in all instances (P < 0.05). Lastly, central pulse pressure was associated with triangular, but not physiologic, mean biases for Pb and RM independent of age or central arterial stiffness (P < 0.05). These findings support the use of personalized physiologic flow waveforms as a more robust alternative to triangular flow waveforms when true flow cannot be measured.NEW & NOTEWORTHY We demonstrate that triangular flow waveforms overestimate wave reflection indices, particularly at higher central pulse pressures independent of age or carotid-femoral pulse wave velocity. In contrast, personalized physiologic flow waveforms provide equivalent wave reflection estimates as measured flow waveforms, thereby offering a more robust alternative to triangulation when aortic flow cannot be measured.


Subject(s)
Aorta/physiology , Arterial Pressure , Blood Pressure Determination , Adult , Age Factors , Aged , Cardiovascular Diseases/diagnosis , Cardiovascular Diseases/physiopathology , Carotid-Femoral Pulse Wave Velocity , Case-Control Studies , Echocardiography, Doppler, Pulsed , Female , Humans , Male , Manometry , Middle Aged , Predictive Value of Tests , Renal Insufficiency, Chronic/diagnosis , Renal Insufficiency, Chronic/physiopathology , Reproducibility of Results , Time Factors , Vascular Stiffness , Young Adult
18.
BMC Cardiovasc Disord ; 21(1): 48, 2021 01 25.
Article in English | MEDLINE | ID: mdl-33494709

ABSTRACT

BACKGROUND AND OBJECTIVES: Fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) are the two most commonly used coronary indices of physiological stenosis severity based on pressure. To minimize the effect of wedge pressure (Pwedge), FFR is measured during hyperemia conditions, and iFR is calculated as the ratio of distal and aortic pressures (Pd/Pa) in the wave-free period. The goal of this study was to predict Pwedge using the backward wave (Pback) through wave separation analysis (WSA) and to reflect the effect of Pwedge on FFR and iFR to identify the relationship between the two indices. METHODS: An in vitro circulation system was constructed to calculate Pwedge. The measurements were performed in cases with stenosis percentages of 48, 71, and 88% and with hydrostatic pressures of 10 and 30 mmHg. Then, the correlation between Pback by WSA and Pwedge was calculated. In vivo coronary flow and pressure were simultaneously measured for 11 vessels in all patients. The FFR and iFR values were reconstructed as the ratios of forward wave at distal and proximal sites during hyperemia and at rest, respectively. RESULTS: Based on the in vitro results, the correlation between Pback and Pwedge was high (r = 0.990, p < 0.0001). In vivo results showed high correlations between FFR and reconstructed FFR (r = 0.992, p < 0.001) and between iFR and reconstructed iFR (r = 0.930, p < 0.001). CONCLUSIONS: Reconstructed FFR and iFR were in good agreement with conventional FFR and iFR. FFR and iFR can be expressed as the variation of trans-stenotic forward pressure, indicating that the two values are inferred from the same formula under different conditions.


Subject(s)
Cardiac Catheterization , Coronary Stenosis/diagnosis , Coronary Vessels/physiopathology , Fractional Flow Reserve, Myocardial , Models, Cardiovascular , Coronary Angiography , Coronary Stenosis/physiopathology , Coronary Vessels/diagnostic imaging , Humans , Hyperemia/physiopathology , Models, Anatomic , Predictive Value of Tests , Reproducibility of Results , Severity of Illness Index , Signal Processing, Computer-Assisted
19.
Front Cardiovasc Med ; 8: 772912, 2021.
Article in English | MEDLINE | ID: mdl-35004887

ABSTRACT

Background: There are scarce and controversial data on whether human immunodeficiency virus (HIV) infection is associated with changes in aortic pressure (aoBP) and waveform-derived indexes. Moreover, it remains unknown whether potential differences in aoBP and waveform indexes between people living with HIV (PLWHIV) and subjects without HIV (HIV-) would be affected by the calibration method of the pressure waveform. Aims: To determine: (i) whether PLWHIV present differences in aoBP and waveform-derived indexes compared to HIV- subjects; (ii) the relative impact of both HIV infection and cardiovascular risk factors (CRFs) on aoBP and waveform-derived indexes; (iii) whether the results of the first and second aims are affected by the calibration method. Methods: Three groups were included: (i) PLWHIV (n = 86), (ii) HIV- subjects (general population; n = 1,000) and (iii) a Reference Group (healthy, non-exposed to CRFs; n = 398). Haemodynamic parameters, brachial pressure (baBP; systolic: baSBP; diastolic: baDBP; mean oscillometric: baMBPosc) and aoBP and waveform-derived indexes were obtained. Brachial mean calculated (baMBPcalc=baDBP+[baSBP-baDBP]/3) pressure was quantified. Three waveform calibration schemes were used: systolic-diastolic, calculated (baMBPcalc/baDBP) and oscillometric mean (baMBPosc/baDBP). Results: Regardless of CRFs and baBP, PLWHIV presented a tendency of having lower aoBP and waveform-derived indexes which clearly reached statistical significance when using the baMBPosc/baDBP or baMBPcalc/baDBP calibration. HIV status exceeded the relative weight of other CRFs as explanatory variables, being the main explanatory variable for variations in central hemodynamics when using the baMBPosc/baDBP, followed by the baMBPcalc/baDBP calibration. Conclusions: The peripheral waveform calibration approach is an important determinant to reveal differences in central hemodynamics in PLWHIV.

20.
Front Physiol ; 12: 774390, 2021.
Article in English | MEDLINE | ID: mdl-35126173

ABSTRACT

Aortic blood pressure (aoBP) waveform-derived indexes could provide valuable (prognostic) information over and above cardiovascular risk factors (CRFs). To obtain aoBP waveform-characteristics, several (i) techniques, (ii) recording sites, (iii) pressure-only waveform analysis mathematical approaches [e.g., pulse wave analysis (PWA), wave separation analysis (WSA)], and (iv) indexes [augmentation pressure and index (AP and AIx), forward (Pf) and backward (Pb) components of aoBP, reflection magnitude (RM), and reflection index (Rix)], were proposed. An accurate clinical use of these indexes requires knowing their physiological age-related profiles and the expected values for a specific subject. There are no works that have characterized waveform-derived indexes profiles in large populations considering: (i) as a continuous, data from different age stages (childhood, adolescence, and adulthood), (ii) complementary indexes, (iii) data obtained from different techniques and approaches, and (iv) analyzing potential sex- and body height (BH)-related differences. In addition, (v) there is a lack of normative data (reference intervals, RIs) for waveform-derived indexes. AIMS: (1) to evaluate the association and agreement between PWA- and/or WSA-derived indexes obtained with different techniques and approaches; (2) to determine the need for sex-, BH-, and/or age-specific RIs; (3) to define RIs for PWA- and WSA-derived indexes in a large cohort of healthy children, adolescents, and adults. METHODS: 3619 subjects (3-90 y) were included; 1688 healthy (2-84 y). AP, AIx, AIx@75, Pf, Pb, RM, and RIx were obtained (carotid and radial tonometry, brachial oscillometry/plethysmography). The association and agreement between indexes were analyzed (Concordance correlation coefficients, Bland-Altman analysis). Mean and SD equations and sex-specific BH- and age-related profiles were obtained (regression methods; fractional polynomials). RESULTS: Waveform-derived indexes were not equivalent; for a specific index, there were systematic and proportional differences associated with the recording site (e.g., carotid vs. radial) and technique (e.g., tonometry vs. oscillometry). The need for sex-, BH-, or age-specific RIs was dependent on the index and/or age considered. RIs were defined for each index considering differences between recording sites and techniques. Equations for waveform-derived indexes age-related profiles were included, enabling to determine for a specific subject, the expected values and potential data deviations.

SELECTION OF CITATIONS
SEARCH DETAIL
...