Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 205
Filter
1.
Mikrochim Acta ; 191(10): 633, 2024 Sep 29.
Article in English | MEDLINE | ID: mdl-39342530

ABSTRACT

The development of a tailored filament is reported composed of reduced graphene oxide (rGO) and carbon black (CB) in a polylactic acid (PLA) matrix and its use in the production of electrochemical sensors. The electrodes containing rGO showed superior performance when compared with  those prepared in the absence of this material. Physicochemical and electrochemical characterizations of the electrodes showed the successful incorporation of both rGO and CB and an improved conductivity in the presence of rGO (lower resistance to charge transfer). As a proof-of-concept, the developed electrodes were applied to the detection of the forensic analytes TNT and cocaine. The electrodes containing rGO presented a superior analytical performance for both TNT and cocaine detection, showing the lower limit of detection values (0.22 and 2.1 µmol L-1, respectively) in comparison with pure CB-PLA electrodes (0.93 and 11.3 µmol L-1, respectively). Besides, better-defined redox peaks were observed, especially for TNT, as well as increased sensitivity for both molecules.

2.
Sensors (Basel) ; 24(16)2024 Aug 22.
Article in English | MEDLINE | ID: mdl-39205114

ABSTRACT

This paper presents a new application of a lanthanum oxide (III)-modified carbon paste electrode (LaOX/CPE) for dopamine (DP) detection in the presence of ascorbic acid (AA). The presence of cetyl trimethyl ammonium bromide (CTAB) facilitated the LaOX/CPE electrode's ability to detect DP amidst AA interference, resulting in a substantial 70.0% increase in the anodic peak current for DP when compared to the unmodified carbon paste electrode (CPE). CTAB enabled clear separation of the anodic peaks for DP and AA by nearly 0.2 V, despite their initially overlapping potential values, through the ion-dipole interaction of AA and CTAB. The electrode was characterized using cyclic voltammetry (CV) and energy-dispersive spectroscopy (EDS). The method demonstrated a detection limit of 0.06 µmol/L with a relative standard deviation (RSD) of 6.0% (n = 15). Accuracy was assessed through the relative error and recovery percent, using urine samples spiked with known quantities of DP.


Subject(s)
Carbon , Cetrimonium , Dopamine , Electrochemical Techniques , Electrodes , Lanthanum , Oxides , Surface-Active Agents , Lanthanum/chemistry , Carbon/chemistry , Dopamine/urine , Dopamine/analysis , Dopamine/chemistry , Oxides/chemistry , Surface-Active Agents/chemistry , Cetrimonium/chemistry , Electrochemical Techniques/methods , Ascorbic Acid/chemistry , Ascorbic Acid/analysis , Limit of Detection , Humans
3.
Mikrochim Acta ; 191(8): 492, 2024 07 27.
Article in English | MEDLINE | ID: mdl-39066907

ABSTRACT

The development and application of an electrochemical sensor is reported for detection of poly(3-hydroxybutyrate) (P3HB) - a bioplastic derived from agro-industrial residues. To overcome the challenges of molecular imprinting of macromolecules such as P3HB, this study employed methanolysis reaction to break down the P3HB biopolymer chains into methyl 3-hydroxybutyrate (M3HB) monomers. Thereafter, M3HB were employed as the target molecules in the construction of molecularly imprinted sensors. The electrochemical device was then prepared by electropolymerizing a molecularly imprinted poly (indole-3-acetic acid) thin film on a glassy carbon electrode surface modified with reduced graphene oxide (GCE/rGO-MIP) in the presence of M3HB. Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), scanning electron microscopy with field emission gun (SEM-FEG), Raman spectroscopy, attenuated total reflection Fourier-transform infrared (ATR-FTIR) and X-ray Photoelectron Spectroscopy (XPS) were employed to characterize the electrode surface. Under ideal conditions, the MIP sensor exhibited a wide linear working range of 0.1 - 10 nM and a detection limit of 0.3 pM (n = 3). The sensor showed good repeatability, selectivity, and stability over time. For the sensor application, the bioproduction of P3HB was carried out in a bioreactor containing the Burkholderia glumae MA13 strain and sugarcane byproducts as a supplementary carbon source. The analyses were validated through recovery assays, yielding recovery values between 102 and 104%. These results indicate that this MIP sensor can present advantages in the monitoring of P3HB during the bioconversion process.


Subject(s)
Burkholderia , Electrochemical Techniques , Electrodes , Graphite , Hydroxybutyrates , Molecularly Imprinted Polymers , Polyesters , Graphite/chemistry , Polyesters/chemistry , Hydroxybutyrates/chemistry , Burkholderia/chemistry , Burkholderia/metabolism , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Molecularly Imprinted Polymers/chemistry , Limit of Detection , Oxidation-Reduction , Polyhydroxybutyrates
4.
Polymers (Basel) ; 16(12)2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38932027

ABSTRACT

In this work, the electrochemical synthesis of PANI and GO-modified PANI was performed using cyclic voltammetry, varying the amount of GO, 1 mg (PG1), 5 mg (PG5), and 10 mg (PG10) to analyze the effect of the amount of GO on the composite. PANI, PG1, PG5, and PG10 materials were characterized using optical microscopy, SEM, UV-vis, FTIR, Raman, and wettability. A stability test was also carried out by putting the materials to 500 oxidation-reduction cycles using cyclic voltammetry. The synthesis method allowed GO in PANI to be added through a chemical interaction between the two compounds. It was also found that the addition of GO led to an improvement in the hydrophilic character of the composite, which would lead to an improvement in the diffusion of reagents/species when the composites are used in aqueous media processes. The results of the stability test showed that the PG10 material presented a lower % loss of specific capacitance and energy compared with the other materials, which indicates that the GO presence (in the amount specified) improves the stability of the PANI. The PG10 material showed favorable and promising conditions for its use in fuel cell and battery processes.

5.
Talanta ; 277: 126391, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38861764

ABSTRACT

An edible Mushroom-Nafion modified glassy carbon electrode (M2N5-GCE) was prepared using a homogeneous mixture varying the concentrations of these, in addition to the origin of the mushroom (Shiitake, Lentinula edodes, M1 and Abrantes, Agariscus bisporus, M2) and applied to the As(III) determination by anodic stripping voltammetry. After choosing the optimal conditions in the preparation of the electrode, the second stage was to study the effects of various parameters such as supporting electrolyte, pH, accumulation potential, and time (Eacc, tacc). The optimum experimental conditions chosen were Britton Robinson buffer 0.01 mol L-1 pH:4.6; Eacc: -1.0 and tacc: 60 s obtaining a signal of oxidation of As(0) to As(III) about 0.08 V. Peak current was proportional to arsenic concentration over the 19.6-117.6 µg L-1 range, with a 3σ detection limit of 13.4 µg L-1. The method was validated using As(III) spiked tap water from the laboratory with satisfactory results (RE:3.0 %). Finally, the method was applied to the determination of As(III) in water samples from the Loa River (Northern Chile) in the presence of As(V) in a concentration >20 times higher (RE: 2.3 %).


Subject(s)
Agaricales , Arsenic , Carbon , Electrodes , Fluorocarbon Polymers , Fluorocarbon Polymers/chemistry , Carbon/chemistry , Arsenic/analysis , Arsenic/chemistry , Agaricales/chemistry , Electrochemical Techniques/methods , Limit of Detection , Hydrogen-Ion Concentration , Water Pollutants, Chemical/analysis , Water Pollutants, Chemical/chemistry , Electrochemistry
6.
Mikrochim Acta ; 191(7): 425, 2024 06 27.
Article in English | MEDLINE | ID: mdl-38926184

ABSTRACT

A solvothermal synthesis of ultrasmall cerium oxide nanoparticles (USCeOxNPs) with an average size of 0.73 ± 0.07 nm using deep eutectic solvent (DES) as a stabilizing medium at a temperature of 90 ºC is reported. Transmission electron microscopy (TEM) and energy dispersive spectroscopy (EDS) were used to morphologically characterize the USCeOxNPs. These revealed approximately spherical shapes with emission lines characteristic of cerium. Selected area electron diffraction (SAED) was used to determine the crystalline structure of the cerium oxide nanoparticles (CeO2NPs), revealing the presence of crystalline cubic structures. The USCeOxNPs-DES/CB film was characterized by scanning electron microscopy (SEM), which demonstrated the spherical characteristic of CB with layers slightly covered by DES residues. DES was characterized by Fourier transform infrared (FT-IR) and nuclear magnetic resonance (NMR), indicating its formation through hydrogen bonds between the precursors. An electrochemical sensor for dopamine (DA) determination in biological fluids was developed using the USCeOxNPs together with carbon black (CB). An enhanced current response was observed on DA voltammetric determination, and this can be attributed to the USCeOxNPs. This sensor displayed linear responses for DA in the range 5.0 × 10-7 mol L-1 to 3.2 × 10-4 mol L-1, with a limit of detection of 80 nmol L-1. Besides detectability, excellent performances were verified for repeatability and anti-interference. The sensor based on USCeOxNPs synthesized in DES in a simpler and environmentally friendly way was successfully applied to determine DA in biological matrix.


Subject(s)
Cerium , Dopamine , Electrochemical Techniques , Cerium/chemistry , Dopamine/analysis , Dopamine/blood , Electrochemical Techniques/methods , Humans , Deep Eutectic Solvents/chemistry , Nanoparticles/chemistry , Limit of Detection , Metal Nanoparticles/chemistry , Particle Size
7.
Arch Biochem Biophys ; 758: 110077, 2024 08.
Article in English | MEDLINE | ID: mdl-38942109

ABSTRACT

Ammonium and hexyltrimethylammonium thiomolybdates (ATM and ATM-C6) and thiotungstates (ATT and ATT-C6) were synthesized. Their toxicity was evaluated using both in vitro and in vivo approaches via the zebrafish embryo acute toxicity assay (ZFET), while the copper-thiometallate interaction was studied using cyclic voltammetry, as well as in an in vivo assay. Cyclic voltammetry suggests that all thiometallates form complexes with copper in a 2:1 Cu:thiometallate ratio. Both in vitro and in vivo assays demonstrated low toxicity in BALB/3T3 cells and in zebrafish embryos, with high IC50 and LC50 values. Furthermore, the hexyltrimethylammonium ion played a crucial role in enhancing viability and reducing toxicity during prolonged treatments for ATM and ATT. In particular, the ZEFT assay uncovered the accumulation of ATM in zebrafish yolk, averted by the incorporation of the hexyltrimethylammonium ion. Notably, the copper-thiometallate interaction assay highlighted the improved viability of embryos when cultured in CuCl2 and ATM-C6, even at high CuCl2 concentrations. The hatching assay further confirmed that copper-ATM-C6 interaction mitigates inhibitory effects induced by thiomolybdates and CuCl2 when administered individually. These results suggest that the incorporation of the hexyltrimethylammonium ion in ATM increase its ability to interact with copper and its potential application as a copper chelator.


Subject(s)
Chelating Agents , Copper , Molybdenum , Zebrafish , Animals , Zebrafish/embryology , Copper/chemistry , Chelating Agents/chemistry , Chelating Agents/pharmacology , Molybdenum/chemistry , Molybdenum/pharmacology , Mice , Embryo, Nonmammalian/drug effects , BALB 3T3 Cells , Quaternary Ammonium Compounds/chemistry , Quaternary Ammonium Compounds/pharmacology
8.
Food Chem ; 454: 139710, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-38815328

ABSTRACT

Food additives are chemical compounds intentionally added during foodstuff production to control technological functions, such as pH, viscosity, stability (color, flavor, taste, and odor), homogeneity, and loss of nutritional value. These compounds are fundamental in inhibition the degradation process and prolonging the shelf life of foodstuffs. However, their inadequate employment or overconsumption can adversely affect consumers' health with the development of allergies, hematological, autoimmune, and reproductive disorders, as well as the development of some types of cancer. Thus, the development and application of simple, fast, low-cost, sensitivity, and selectivity analytical methods for identifying and quantifying food additives from various chemical classes and in different foodstuffs are fundamental to quality control and ensuring food safety. This review presents trends in the detection of food additives in foodstuffs using differential pulse voltammetry and square wave voltammetry, the main pulse voltammetric techniques, indicating the advantages, drawbacks, and applicability in food analysis. Are discussed the importance of adequate choices of working electrode materials in the improvements of analytical results, allowing reliable, accurate, and inexpensive voltammetric methods for detecting these compounds in foodstuffs samples.


Subject(s)
Electrochemical Techniques , Food Additives , Food Analysis , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Food Additives/analysis , Food Analysis/methods
9.
Talanta ; 272: 125776, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38428129

ABSTRACT

Herein, a simple, green, and relatively inexpensive approach to determine nickel (Ni) in biodiesel samples by square wave adsorptive cathodic stripping voltammetry (SWAdCSV) is presented. A method based on the accumulation of Ni as Ni(II)-dimethylglyoxime (Ni(II)(HDMG)2) on the glassy carbon electrode was carried out in a solution containing the aqueous phase extract (APhEx) obtained from an extraction induced by microemulsion breaking (EIMB), which was achieved by adding a few microliters of ultrapure water to a microemulsion composed of biodiesel, n-propanol and a diluted HNO3 solution. The LOD and LOQ were 0.2 µg L-1 and 0.8 µg L-1, respectively, and the accuracy was evaluated by recovery assays of spiked samples and by analyzing a standard reference material. Results obtained from a comparative method (HR-CS GF AAS) were also used for this evaluation. The method was applied to biodiesel samples produced from different feedstocks. To the best of the authors knowledge, it is the first time that: 1) Ni in biodiesel is determined by a voltammetric method; 2) EIMB is applied to extract Ni from this matrix and 3) this type of sample preparation method is used with adsorptive stripping voltammetry.

10.
Mikrochim Acta ; 191(4): 197, 2024 03 14.
Article in English | MEDLINE | ID: mdl-38483622

ABSTRACT

A fully reusable electrochemical device is proposed for the first time made from laser cutting and a homemade conductive ink composed of carbon and nail polish. As a sensor substrate, we applied polymethyl methacrylate, which allows the surface to be renewed by simply removing and reapplying a new layer of ink. In addition to the ease of renewing the sensor's conductive surface, the design of the device has allowed for the integration of different forms of analysis. The determination of L-Dopa was performed using DPV, which presented a linear response range between 5.0 and 1000.0 µmol L-1, and a LOD of 0.11 µmol L-1. For dopamine, a flow injection analysis system was employed, and using the amperometric technique measurements were performed with a linear ranging from 2.0 to 100.0 µmol L-1 and a LOD of 0.26 µmol L-1. To demonstrate its applicability, the device was used in the quantification of analytes in pharmaceutical drug and synthetic urine samples.


Subject(s)
Graphite , Levodopa , Levodopa/analysis , Dopamine/analysis , Electrochemical Techniques/methods , Electrodes , Reproducibility of Results
11.
Adv Healthc Mater ; 13(11): e2303509, 2024 04.
Article in English | MEDLINE | ID: mdl-38245830

ABSTRACT

Multiplexing is a valuable strategy to boost throughput and improve clinical accuracy. Exploiting the vertical, meshed design of reproducible and low-cost ultra-dense electrochemical chips, the unprecedented single-response multiplexing of typical label-free biosensors is reported. Using a cheap, handheld one-channel workstation and a single redox probe, that is, ferro/ferricyanide, the recognition events taking place on two spatially resolved locations of the same working electrode can be tracked along a single voltammetry scan by collecting the electrochemical signatures of the probe in relation to different quasi-reference electrodes, Au (0 V) and Ag/AgCl ink (+0.2 V). This spatial isolation prevents crosstalk between the redox tags and interferences over functionalization and binding steps, representing an advantage over the existing non-spatially resolved single-response multiplex strategies. As proof of concept, peptide-tethered immunosensors are demonstrated to provide the duplex detection of COVID-19 antibodies, thereby doubling the throughput while achieving 100% accuracy in serum samples. The approach is envisioned to enable broad applications in high-throughput and multi-analyte platforms, as it can be tailored to other biosensing devices and formats.


Subject(s)
Biosensing Techniques , COVID-19 , Electrochemical Techniques , SARS-CoV-2 , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Humans , SARS-CoV-2/isolation & purification , COVID-19/diagnosis , COVID-19/blood , Electrodes , Antibodies, Viral/blood , Gold/chemistry , Immunoassay/methods , Immunoassay/instrumentation
12.
Heliyon ; 10(1): e23808, 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-38226225

ABSTRACT

A method to access carbonyl compounds using reductive conditions was evaluated via electrochemical reduction of their corresponding N-benzyloxyphthalimide derivatives (NBOPIs). The mechanism of this originally reported electrochemical reaction was proposed based on DFT calculation and is experimentally confirmed herein, contrasting simulated and experimental cyclic voltammetry data. The reaction scope studied in a preparative scale and using redox sensitive functional groups showed good selectivity and tolerance toward oxidation under the reaction conditions with a moderate to good yield (50-71%). Nevertheless, some restrictions with reducible functional groups, like benzyl-brominated and nitro-aromatic derivatives, were observed. The present approach can be considered a self-sustainable electrochemical catalysis for the synthesis of aromatic carbonylic compounds passing through anion radical intermediates produced by a cathodic reaction.

13.
Water Environ Res ; 96(1): e10981, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38264917

ABSTRACT

Green-synthesized iron nanoparticles (GAP-FeNP) were used as particle electrodes in a three-dimensional electro-Fenton (3DEF) process to accelerate the removal of hexavalent chromium [Cr (VI)]. Removal was evaluated by varying the pH (3.0, 6.0, and 9.0) and initial Cr (VI) concentrations (10, 30, and 50 mg/L) at 5 and 25 min. These results demonstrated that GAP-FeNP/3DEF treatment achieved more than 94% Cr (VI) removal under all tested conditions. Furthermore, it was observed that Cr (VI) removal exceeded 98% under pH 9.0 in all experimental parameters tested. The results of the response surface methodology (RSM) determined two optimal conditions: the first, characterized by a pH of 3.0, Cr (VI) concentration at 50 mg/L, and 25 min, yielded a Cr (VI) removal of 99.7%. The second optimal condition emerged at pH 9.0, with Cr (VI) concentrations of 10 mg/L and 5 min, achieving a Cr (VI) removal of 99.5%. This study highlights the potential of the GAP-FeNP to synergistically accelerate Cr (VI) removal by the 3DEF process, allowing faster elimination and expansion of the alkaline (pH 9.0) applicability. PRACTITIONER POINTS: The required time for >99% of Cr (VI) removal by the GAP-FeNP/3DEF process was shortened from 25 to 5 min. EF process with GAP-FeNP reduces the time necessary for Cr (VI) removal, which is 67% faster than conventional methods. EF process using GAP-FeNP removed >94% of Cr (VI) after 25 min for all initial Cr (VI) concentrations and pH treatments. Cr (VI) removal by the GAP-FeNP/3DEF process was >98% at a pH of 9.0, widening the solution pH applicability.


Subject(s)
Iron , Nanoparticles , Electrodes
14.
Environ Technol ; 45(12): 2388-2401, 2024 May.
Article in English | MEDLINE | ID: mdl-36734624

ABSTRACT

The widespread use of pesticides requires effective detection and quantification tools to improve monitoring of environmental quality. Electrochemical sensors offer a fast and sensitive response, and can also be optimized by combining several constituents and techniques, including biodegradable materials, being useful in the determination of chemical agents from environmental samples. Here, we produced a polymer-based sensor for 2,4,6-trichlorophenol determination, through electrospinning of poly(lactic acid)/poly(butylene adipate-co-terephthalate) (PLA/PBAT) blend with graphite. The graphite-containing fibres were thermally treated and wetted in mineral oil, thus forming a paste, used as an electrode in the electrochemical sensor. The thermal analysis indicated a disorganization of the polymeric chains between the aromatic carbon chain of the PBAT polymer, resulting in a material with low enthalpy, lower crystallinity and greater thermal degradability after insertion of graphite in polymeric fibres. NIR spectra revealed changes related to the carbonyls of the polymeric ester groups. Cyclic voltammetry and square wave voltammetry techniques were applied to study the electrochemical behaviour of developed sensor. The thermal treatment of graphite-containing fibres increased the adhesion surface in which occurs the adsorption of the analyte on the electrode, which improved the peak current in the electrochemical tests. The PLA/PBAT/Graphite sensor applied to determination of 2,4,6-TCP presented the detection and quantification limits of 7.84 × 10-8 mol L-1 (0.0155 mg L-1) and 2.36 × 10-7 mol L-1 (0.0466 mg L-1) with a linearity response of 1.00 × 10-7 mol L-1 and 2.00 × 10-6 mol L-1 with correlation coefficient of 0.993 (r2).


Subject(s)
Chlorophenols , Graphite , Polyesters , Polymers
15.
J Inorg Biochem ; 251: 112441, 2024 02.
Article in English | MEDLINE | ID: mdl-38103419

ABSTRACT

A prion-derived copper(II)-binding peptide was assembled onto a gold electrode for the building of a voltammetric biosensor for measuring the Cu2+ metal ion in biological samples. The chosen sequence was H-CVNITKQHTVTTTT-NH2, with an appended cysteine residue for binding to the gold surface as a self-assembled monolayer and a histidine residue as the anchorage point for copper(II) complexation. The biosensor showed a linear range of 10-7 to 10-6 M with an 8.0 × 10-8 M detection limit and a 1.0 × 10-7 M quantification limit, with good precision, trueness, and absence of matrix effect. The quantification of Cu2+ was performed in the presence of other transition metal ions, such as Zn2+, Cd2+, Fe2+, or Ni2+, which indicates the excellent selectivity of the biosensor. When the modified electrode was applied for measuring copper(II) in calcined coffee seeds, a difference in copper amount was observed between two Coffea arabica cultivars that were submitted to a treatment with a copper-based antifungal, showing the applicability of the biosensor in the agricultural field.


Subject(s)
Biosensing Techniques , Copper , Copper/chemistry , Coffee , Peptides/chemistry , Gold/chemistry , Ions
16.
Molecules ; 28(17)2023 Aug 31.
Article in English | MEDLINE | ID: mdl-37687201

ABSTRACT

In this study, a novel electrochemical assay for determining 17-ß-estradiol (E2) was proposed. The approach involves modifying a glassy carbon electrode (GCE) with a nanocomposite consisting of α-Fe2O3 nanoparticles supported on carbon nanotubes (CNTs)-denoted as α-Fe2O3-CNT/GCE. The synthesis of the α-Fe2O3-CNT nanocomposite was achieved through a simple and cost-effective hydrothermal process. Morphological and chemical characterization were conducted using scanning electron microscopy (SEM), Raman spectroscopy, and energy-dispersive X-ray spectroscopy (EDX). The presence of the α-Fe2O3-CNT film on the GCE surface resulted in an enhanced electrochemical response to E2, preventing electrode surface fouling and mitigating the decrease in peak current intensity during E2 oxidation. These outcomes substantiate the rationale behind the GCE modification. After the optimization of experimental conditions, E2 was determined by the square wave voltammetry technique using 0.1 mol L-1 KCl solution (pH = 7.0) with 20% ethanol as a supporting electrolyte. A linear concentration range of 5.0-100.0 nmol L-1 and a low limit of detection of 4.4 nmol L-1 were obtained. The electroanalytical method using α-Fe2O3-CNT/GCE was applied for E2 determination in pharmaceutical, lake water, and synthetic urine samples. The obtained results were attested by recovery tests and by high-performance liquid chromatography as a comparative technique at a 95% confidence level. Thus, the developed electrochemical sensor is simple and fast to obtain, presents high accuracy, and is viable for determining E2 in routine analysis.

17.
Mikrochim Acta ; 190(10): 379, 2023 09 08.
Article in English | MEDLINE | ID: mdl-37682352

ABSTRACT

Graphite sheet (GS) electrodes are flexible and versatile substrates for sensing electrochemical; however, their use has been limited to incorporate (bio)chemical modifiers. Herein, we demonstrated that a cold (low temperature) CO2 plasma treatment of GS electrodes provides a substantial improvement of the electrochemical activity of these electrodes due to the increased structural defects on the GS surface as revealed by Raman spectroscopy (ID/IG ratio), and scanning electron microscopy images. XPS analyses confirmed the formation of oxygenated functional groups at the GS surface after the plasma treatment that are intrinsically related to the substantial increase in the electron transfer coefficient (K0 values increased from 1.46 × 10-6 to 2.09 × 10-3 cm s-1) and with reduction of the resistance to charge transfer (from 129.8 to 0.251 kΩ). The improved electrochemical activity of CO2-GS electrodes was checked for the detection of emerging contaminant species, such as chloramphenicol (CHL), ciprofloxacin (CIP) and sulphanilamide (SUL) antibiotics, at around + 0.15, + 1.10 and + 0.85 V (versus Ag/AgCl), respectively, by square wave voltammetry. Limit of detection values in the submicromolar range were achieved for CHL (0.08 µmol L-1), CIP (0.01 µmol L-1) and SFL (0.11 µmol L-1), which enabled the sensor to be successfully applied to natural waters and urine samples (recovery values from 85 to 119%). The CO2-GS electrode is highly stable and inexpensive ($0.09 each sensor) and can be easily inserted in portable 3D printed cells for environmental on-site analyses.


Subject(s)
Chloramphenicol , Graphite , Ciprofloxacin , Sulfanilamide , Carbon Dioxide , Electrodes
18.
Sensors (Basel) ; 23(18)2023 Sep 07.
Article in English | MEDLINE | ID: mdl-37765789

ABSTRACT

In this work we describe a straightforward approach for creating a nanocomposite comprising multiwalled carbon nanotubes (MWCNTs) and titanium dioxide (TiO2) using the hydrothermal technique, which is then characterized by scanning electron microscope (SEM), energy-dispersive X-ray spectrometer (EDS), X-ray diffraction analysis (XRD), Fourier transform infrared spectroscopy (FTIR), and thermal gravimetric analysis (TGA) to assess its properties. Nafion is employed as a reticular agent for the nanocomposite on the glassy carbon electrode (GCE), creating the MWCNT/TiO2/Nafion/GCE system. The electrochemical behavior of the system was evaluated using cyclic voltammetry, revealing its remarkable electrocatalytic activity for detecting hydrogen peroxide in water. The developed sensor showcased a broad linear response range of 14.00 to 120.00 µM, with a low detection limit of 4.00 µM. This electrochemical sensor provides a simple and highly sensitive method for detecting hydrogen peroxide in aqueous solutions and shows promising potential for various real-world applications, particularly in H2O2 monitoring.

19.
Mikrochim Acta ; 190(10): 409, 2023 09 21.
Article in English | MEDLINE | ID: mdl-37733170

ABSTRACT

Alzheimer's disease (AD) is considered one of the main progressive chronic diseases in elderly individuals. Early diagnosis using related biomarkers, specifically beta-amyloid peptide (Aß), allows finding expected treatment routes. Here, we developed an electrochemical aptasensing platform for AD by employing a glassy carbon electrode (GCE) modified with a layer of jagged gold (JG) nanostructure (diameter: 60-185 nm) and graphene oxide-carboxylic acid functionalized multiwalled carbon nanotubes (GO-c-MWCNTs) nanocomposite. These surface modifications acted as the signal amplifier and provided an optimum nano-interface substrate for immobilizing aptamer strands. The measurements of Aß were performed via differential pulse voltammetry (DPV), and the aptasensor detected the analyte in a linear range from 0.1 pg mL-1 to 1 ng mL-1, with an estimated limit of detection (LOD) of about 0.088 pg mL-1 (S/N = 3). The aptasensor showed sufficient stability (11 days), reversibility (three times), and reproducibility (five times re-fabrication with relative standard deviation (RSD): 1.27). The potential interfering agents showed negligible impact on the sensing performance. Finally, the application of the aptasensor was evaluated in the presence of 10 serum samples, and the recovery values were from 93 to 110.1%.


Subject(s)
Alzheimer Disease , Nanocomposites , Nanotubes, Carbon , Aged , Humans , Alzheimer Disease/diagnosis , Reproducibility of Results , Gold
20.
Anal Chim Acta ; 1276: 341589, 2023 Oct 02.
Article in English | MEDLINE | ID: mdl-37573093

ABSTRACT

Routine monitoring of inorganic arsenic in groundwater using sensitive, reliable, easy-to-use and affordable analytical methods is integral to identifying sources, and delivering appropriate remediation solutions, to the widespread global issue of arsenic pollution. Voltammetry has many advantages over other analytical techniques, but the low electroactivity of arsenic(V) requires the use of either reducing agents or relatively strong acidic conditions, which both complicate the analytical procedures, and require more complex material handling by skilled operators. Here, we present the voltammetric determination of total inorganic arsenic in conditions of near-neutral pH using a new commercially available 25 µm diameter gold microwire (called the Gold Wirebond), which is described here for the first time. The method is based on the addition of low concentrations of permanganate (10 µM MnO4-) which fulfils two roles: (1) to ensure that all inorganic arsenic is present as arsenate by chemically oxidising arsenite to arsenate and, (2) to provide a source of manganese allowing the sensitive detection of arsenate by anodic stripping voltammetry at a gold electrode. Tests were carried out in synthetic solutions of various pH (ranging from 4.7 to 9) in presence/absence of chloride. The best response was obtained in 0.25 M chloride-containing acetate buffer resulting in analytical parameters (limit of detection of 0.28 µg L-1 for 10 s deposition time, linear range up to 20 µg L-1 and a sensitivity of 63.5 nA ppb-1. s-1) better than those obtained in acidic conditions. We used this new method to measure arsenic concentrations in contrasting groundwaters: the reducing, arsenite-rich groundwaters of India (West Bengal and Bihar regions) and the oxidising, arsenate-rich groundwaters of Mexico (Guanajuato region). Very good agreement was obtained in all groundwaters with arsenic concentrations measured by inductively coupled plasma-mass spectrometry (slope = +1.029, R2 = 0.99). The voltammetric method is sensitive, faster than other voltammetric techniques for detection of arsenic (typically 10 min per sample including triplicate measurements and 2 standard additions), easier to implement than previous methods (no acidic conditions, no chemical reduction required, reproducible sensor, can be used by non-voltammetric experts) and could enable cheaper groundwater surveying campaigns with in-the-field analysis for quick data reporting, even in remote communities.

SELECTION OF CITATIONS
SEARCH DETAIL