Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22.687
Filter
1.
J. optom. (Internet) ; 17(3): [100505], jul.-sept2024. tab, graf
Article in English | IBECS | ID: ibc-231869

ABSTRACT

Purpose: This study explored whether retinoscopy (RET) provides comparable results of relative peripheral refraction (RPR) to open–field autorefractometry (AR) in myopic subjects.Methods: Peripheral refraction was measured in 20 myopic and 20 control adult subjects. Both central and peripheral refraction (20° nasal and temporal eccentricity) were measured using RET and open-field AR. Differences in the median central spherical equivalent (SE), median RPR, and median J45/J180 power vectors between the RET and AR techniques were analyzed. Moreover, Bland – Altman plots were used to assess the agreement between RET and AR methods for RPR measurements in MG. Results: For MG, the median RPR values were positive (hyperopic shift), and no significant differences were observed between the RET and AR techniques with respect to RPR measurement. In addition, we did not observe any significant differences in the RPR values between the nasal and temporal eccentricities for either the RET or AR technique for myopic subjects. There was also a significant correlation and agreement between the RET and AR technique for RPR measurements. With respect to central refraction, the median SE was slightly more positive for the RET than for the AR technique. Inside the CG, we also found significant correlation between the RET and AR technique for RPR measurements, and we observed a myopic shift in peripheral eccentricities. Conclusion: Our results show that retinoscopy may be a useful tool for objective measurements of RPR in myopic subjects and may be used interchangeably with the open-field AR method in everyday clinical practice. (AU)


Subject(s)
Humans , Retinoscopy , Myopia , Refraction, Ocular , Vision, Ocular , Vision, Binocular , Ophthalmologists
2.
J. optom. (Internet) ; 17(3): [100497], jul.-sept2024. graf, tab
Article in English | IBECS | ID: ibc-231871

ABSTRACT

Purpose: To compare the eye defocus curves (DCs) obtained with stimuli on red, green, and white backgrounds and to investigate the applicability of the duochrome test (DT) in different age groups. Methods: 12 elderly (ELD: 59.3 ± 3.9 years) and 8 young (YG: 22.1 ± 1.1 years) subjects were recruited. An optometric assessment with the DT was carried out to obtain the subjective refraction at distance. DCs at distance on green, white, and red backgrounds were measured and the following parameters were deduced: dioptric difference between red-green, green-white, red-white focal positions (minima of the DCs), best corrected visual acuity (BCVA), and widths of the DCs for red, green, and white. Results: The DC difference between the green-white focal positions (mean ± standard deviation) was -0.12±0.17 diopters (D) (ELD, p = 0.012) and -0.11±0.12 D (YG, p = 0.039), while the red-white difference was not statistically significant. The DC red-green difference was 0.20±0.16 D (ELD, p = 0.002) and 0.18±0.18 D (YG, p = 0.008). The ELD BCVA with green background was significantly worse than BCVA with red (p = 0.007) and white (p = 0.007). The mean value of the DC's width in ELD for green (1.01±0.36 D) was higher than for red (0.77±0.21 D) and for white (0.84±0.35 D), but with no statistical significance. Conclusion: Both age groups showed a slight focusing preference for red when using white light. Moreover, ELD showed a worse BCVA with a green compared to a red background. Despite these results deduced by DC analyses, these aspects do not compromise the possibility of using the DT in clinical practice both in the young and in the elderly. Furthermore, the difference of about 0.20 D between red-green DC in both groups confirms the clinical appropriateness of the widespread use of 0.25 D step as the standard minimum difference in power between correcting lenses.(AU)


Subject(s)
Humans , Male , Female , Young Adult , Aged , Vision, Ocular , Visual Acuity , Fundus Oculi , Contact Lenses , Vision Tests
3.
J. optom. (Internet) ; 17(3): [100510], jul.-sept2024. tab
Article in English | IBECS | ID: ibc-231872

ABSTRACT

Purpose: To evaluate the association between visual symptoms and use of digital devices considering the presence of visual dysfunctions. Methods: An optometric examination was conducted in a clinical sample of 346 patients to diagnose any type of visual anomaly. Visual symptoms were collected using the validated SQVD questionnaire. A threshold of 6 hours per day was used to quantify the effects of digital device usage and patients were divided into two groups: under and above of 35 years old. A multivariate logistic regression was employed to investigate the association between digital device use and symptoms, with visual dysfunctions considered as a confounding variable. Crude and the adjusted odds ratio (OR) were calculated for each variable. Results: 57.02 % of the subjects reported visual symptoms, and 65.02% exhibited some form of visual dysfunction. For patients under 35 years old, an association was found between having visual symptoms and digital device use (OR = 2.10, p = 0.01). However, after adjusting for visual dysfunctions, this association disappeared (OR = 1.44, p = 0.27) and the association was instead between symptoms and refractive dysfunction (OR = 6.52, p < 0.001), accommodative (OR = 10.47, p < 0.001), binocular (OR = 6.68, p < 0.001) and accommodative plus binocular dysfunctions (OR = 46.84, p < 0.001). Among patients over 35 years old, no association was found between symptoms and the use of digital devices (OR = 1.27, p = 0.49) but there was an association between symptoms and refractive dysfunction (OR = 3.54, p = 0.001). Conclusions: Visual symptoms are not dependent on the duration of digital device use but rather on the presence of any type of visual dysfunction: refractive, accommodative and/or binocular one, which should be diagnosed.(AU)


Subject(s)
Humans , Male , Female , Vision, Ocular , Vision Tests , Visual Fields , Visually Impaired Persons , Vision, Binocular , Surveys and Questionnaires , Optometry
4.
J. optom. (Internet) ; 17(3): [100491], jul.-sept2024. ilus, tab, graf
Article in English | IBECS | ID: ibc-231873

ABSTRACT

Background and objectives: The invention described herein is a prototype based on computer vision technology that measures depth perception and is intended for the early examination of stereopsis. Materials and methods: The prototype (software and hardware) is a depth perception measurement system that consists on: (a) a screen showing stereoscopic models with a guide point that the subject must point to; (b) a camera capturing the distance between the screen and the subject's finger; and (c) a unit for recording, processing and storing the captured measurements. For test validation, the reproducibility and reliability of the platform were calculated by comparing results with standard stereoscopic tests. A demographic study of depth perception by subgroup analysis is shown. Subjective comparison of the different tests was carried out by means of a satisfaction survey. Results: We included 94 subjects, 25 children and 69 adults, with a mean age of 34.2 ± 18.9 years; 36.2 % were men and 63.8 % were women. The DALE3D platform obtained good repeatability with an interclass correlation coefficient (ICC) between 0.94 and 0.87, and coefficient of variation (CV) between 0.1 and 0.26. Threshold determining optimal and suboptimal results was calculated for Randot and DALE3D test. Spearman's correlation coefficient, between thresholds was not statistically significant (p value > 0.05). The test was considered more visually appealing and easier to use by the participants (90 % maximum score). Conclusions: The DALE3D platform is a potentially useful tool for measuring depth perception with optimal reproducibility rates. Its innovative design makes it a more intuitive tool for children than current stereoscopic tests. Nevertheless, further studies will be needed to assess whether the depth perception measured by the DALE3D platform is a sufficiently reliable parameter to assess stereopsis.(AU)


Subject(s)
Humans , Male , Female , Child , Adolescent , Young Adult , Vision, Binocular , Depth Perception , Vision, Ocular , Vision Tests
5.
J. optom. (Internet) ; 17(3): [100508], jul.-sept2024. tab, graf
Article in English | IBECS | ID: ibc-231874

ABSTRACT

Purpose: To report the visual and refractive characteristics and the prevalence of amblyopia in patients with different types of Duane's Retraction Syndrome (DRS). Method: This retrospective study was performed on hospital records of 582 DRS patients at Farabi Hospital, Iran, from 2012 to March 2022. Results: The mean age of patients was 19.4 ± 11.9 (range, 3–70) years [335 (57.6 %) females and 247 (42.4 %) males (P < .001)]. DRS type I, II, III, and IV were presented in 347 (59.6 %), 148 (25.4 %), 82 (14.1 %), and 5 (0.9 %) patients, respectively. There were 530 (91.1 %) patients with unilateral and 52 (8.9 %) with bilateral involvement. In the unilateral patients, the DRS eyes' corrected distance visual acuity (CDVA) and astigmatism were significantly worse than the Non-DRS Eyes (P < .001). The mean amount of all refractive and visual parameters in bilateral patients' right or left eyes was significantly lower than in unilateral patients' non-DRS eyes (all P < .05). Anisometropia was observed in 75(12.9 %) of the patients. Amblyopia was observed in 18.5 % (98 patients) and 36.5 % (19 patients) of unilateral and bilateral DRS patients, respectively (P < .001). In unilateral patients, amblyopia was found in 57 (16.4 %) patients with Type I, 22 (14.9 %) patients with Type II, 16 (19.5 %) patients with Type III, and 3 (60 %) patients with Type IV. Forty-four (37.6 %) of patients with amblyopia had anisometropia. Conclusion: This large-scale study indicates that DRS types differ in terms of refractive error, visual acuity, and the prevalence of amblyopia and anisometropia. Clinicians should be aware of the clinical features associated with different types of DRS.(AU)


Subject(s)
Humans , Male , Female , Vision, Ocular , Amblyopia , Duane Retraction Syndrome , Refractive Errors , Anisometropia
6.
J. optom. (Internet) ; 17(3): [100512], jul.-sept2024. graf, tab
Article in English | IBECS | ID: ibc-231875

ABSTRACT

Purpose: In children under 20 years, refractive development targets a cycloplegic refractive error of +0.5 to +1.5D, while presbyopes over 40 years generally have non-cycloplegic errors of ≥ +1D. Some papers suggest these periods are separated by a period of myopic refractive error (i.e., ≤ –0.50D), but this remains unclear. Hence, this work investigates the mean cycloplegic refractive error in adults aged between 20 – 40 years. Methods: In 2002 a cross-sectional study with stratified cluster sampling was performed on the population of Tehran, providing cycloplegic and non-cycloplegic refractive error data for the right eyes of 3,576 participants, aged 30.6 ± 18.6 years (range: 1–86 years). After grouping these data into age groups of 5 years, the refractive error histogram of each group was fitted to a Bigaussian function. The mean of the central, emmetropized peak was used to estimate the mean refractive error without the influence of myopia. Results: The mean cycloplegic refractive error at the emmetropized peak decreased from +1.10 ± 0.11D (95 % confidence interval) to +0.50 ± 0.04D before 20 years and remains stable at that value until the age of 50 years. The non-cycloplegic refractive error also sees a stable phase at 0.00 ± 0.04D between 15 – 45 years. After 45 – 50 years both cycloplegic and non-cycloplegic refractive error become more hypermetropic over time, +1.14 ± 0.12D at 75 years. Conclusions: The cycloplegic refractive error in adults is about +0.50D between 20 – 50 years, disproving the existence of the myopic period at those ages.(AU)


Subject(s)
Humans , Male , Female , Adult , Vision, Ocular , Vision Tests , Refractive Errors , Emmetropia , Cross-Sectional Studies , Iran
10.
Optom Vis Sci ; 101(5): 284, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38857041
12.
Sci Rep ; 14(1): 14454, 2024 06 24.
Article in English | MEDLINE | ID: mdl-38914633

ABSTRACT

Hydrogen peroxide is considered deleterious molecule that cause cellular damage integrity and function. Its key redox signaling molecule in oxidative stress and exerts toxicity on a wide range of organisms. Thus, to understand whether oxidative stress alters visual development, zebrafish embryos were exposed to H2O2 at concentration of 0.02 to 62.5 mM for 7 days. Eye to body length ratio (EBR) and apoptosis in retina at 48 hpf, and optomotor response (OMR) at 7 dpf were all measured. To investigate whether hydrogen peroxide-induced effects were mediated by oxidative stress, embryos were co-incubated with the antioxidant, glutathione (GSH) at 50 µM. Results revealed that concentrations of H2O2 at or above 0.1 mM induced developmental toxicity, leading to increased mortality and hatching delay. Furthermore, exposure to 0.1 mM H2O2 decreased EBR at 48 hpf and impaired OMR visual behavior at 7 dpf. Additionally, exposure increased the area of apoptotic cells in the retina at 48 hpf. The addition of GSH reversed the effects of H2O2, suggesting the involvement of oxidative stress. H2O2 decreased the expression of eye development-related genes, pax6α and pax6ß. The expression of apoptosis-related genes, tp53, casp3 and bax, significantly increased, while bcl2α expression decreased. Antioxidant-related genes sod1, cat and gpx1a showed decreased expression. Expression levels of estrogen receptors (ERs) (esr1, esr2α, and esr2ß) and ovarian and brain aromatase genes (cyp19a1a and cyp19a1b, respectively) were also significantly reduced. Interestingly, co-incubation of GSH effectivity reversed the impact of H2O2 on most parameters. Overall, these results demonstrate that H2O2 induces adverse effects on visual development via oxidative stress, which leads to alter apoptosis, diminished antioxidant defenses and reduced estrogen production.


Subject(s)
Antioxidants , Apoptosis , Hydrogen Peroxide , Oxidative Stress , Zebrafish , Animals , Oxidative Stress/drug effects , Apoptosis/drug effects , Antioxidants/pharmacology , Antioxidants/metabolism , Zebrafish Proteins/metabolism , Zebrafish Proteins/genetics , Glutathione/metabolism , Retina/drug effects , Retina/metabolism , Estrogens/pharmacology , Gene Expression Regulation, Developmental/drug effects , Embryo, Nonmammalian/drug effects , Embryo, Nonmammalian/metabolism , Vision, Ocular/drug effects
13.
Acta Neuropathol Commun ; 12(1): 85, 2024 05 31.
Article in English | MEDLINE | ID: mdl-38822433

ABSTRACT

Here, we test whether early visual and OCT rod energy-linked biomarkers indicating pathophysiology in nicotinamide nucleotide transhydrogenase (Nnt)-null 5xFAD mice also occur in Nnt-intact 5xFAD mice and whether these biomarkers can be pharmacologically treated. Four-month-old wild-type or 5xFAD C57BL/6 substrains with either a null (B6J) Nnt or intact Nnt gene (B6NTac) and 5xFAD B6J mice treated for one month with either R-carvedilol + vehicle or only vehicle (0.01% DMSO) were studied. The contrast sensitivity (CS), external limiting membrane-retinal pigment epithelium (ELM-RPE) thickness (a proxy for low pH-triggered water removal), profile shape of the hyperreflective band just posterior to the ELM (i.e., the mitochondrial configuration within photoreceptors per aspect ratio [MCP/AR]), and retinal laminar thickness were measured. Both wild-type substrains showed similar visual performance indices and dark-evoked ELM-RPE contraction. The lack of a light-dark change in B6NTac MCP/AR, unlike in B6J mice, is consistent with relatively greater mitochondrial efficiency. 5xFAD B6J mice, but not 5xFAD B6NTac mice, showed lower-than-WT CS. Light-adapted 5xFAD substrains both showed abnormal ELM-RPE contraction and greater-than-WT MCP/AR contraction. The inner retina and superior outer retina were thinner. Treating 5xFAD B6J mice with R-carvedilol + DMSO or DMSO alone corrected CS and ELM-RPE contraction but not supernormal MCP/AR contraction or laminar thinning. These results provide biomarker evidence for prodromal photoreceptor mitochondrial dysfunction/oxidative stress/oxidative damage, which is unrelated to visual performance, as well as the presence of the Nnt gene. This pathophysiology is druggable in 5xFAD mice.


Subject(s)
Dimethyl Sulfoxide , Mice, Inbred C57BL , Animals , Mice , Dimethyl Sulfoxide/pharmacology , Biomarkers/metabolism , Mice, Transgenic , Tomography, Optical Coherence , Retinal Rod Photoreceptor Cells/drug effects , Contrast Sensitivity/drug effects , Contrast Sensitivity/physiology , Disease Models, Animal , Retinal Pigment Epithelium/drug effects , Retinal Pigment Epithelium/pathology , Retinal Pigment Epithelium/metabolism , Vision, Ocular/drug effects , Vision, Ocular/physiology
14.
J. optom. (Internet) ; 17(2): [100485], Abr-Jun, 2024. tab, ilus
Article in English | IBECS | ID: ibc-231620

ABSTRACT

Purpose: To study topographic epithelial and total corneal thickness changes in myopic subjects undergoing successful orthokeratology treatment in connection with the objective assessment of contact lens decentration. Methods: A prospective-observational and non-randomized study in 32 Caucasian myopic eyes undergoing Ortho-k for 3 months. Total, epithelial, and stromal thicknesses were studied before and after Ortho-k treatment, using optical coherence tomography with anterior segment application software. Central, paracentral, and mid-peripheral values are taken along 8 semi-meridians. Results: The central average total corneal thickness was 4.72 ± 1.04 μm thinner after Ortho-K. The paracentral corneal thickness showed no significant changes (p = 0.137), while the mid-peripheral corneal thickness was increased by 3.25 ± 1.6 μm associating this increase exclusively to the epithelial plot (p<0.001). When lens centration was assessed, a lens fitting decentration less than 1.0 mm was found for the whole sample, predominantly horizontal-temporal (87.5%) and vertical-inferior (50%) decentring. Corneal topographical analysis revealed a horizontal and vertical epithelial thickness asymmetric change profile with paracentral temporal thinnest values, and mid-peripheral nasal thickest values. Conclusions: The present study found a central corneal thinning induced by Ortho-k lenses in subjects with moderate myopia, only associated with a change in epithelial thickness, as well as mid-peripheral thickening, that seems to be mainly epithelial in origin. The authors also found a tendency of contact lens decentration toward temporal and inferior areas conditioning an asymmetric epithelial redistribution pattern.(AU)


Subject(s)
Humans , Male , Female , Vision, Ocular , Myopia , Lens, Crystalline , Orthokeratologic Procedures , Corneal Stroma , Tomography, Optical Coherence , Retrospective Studies , Optometry , Ophthalmology , Prospective Studies
15.
J. optom. (Internet) ; 17(2): [100492], Abr-Jun, 2024. tab
Article in English | IBECS | ID: ibc-231621

ABSTRACT

Purpose: Given the increase in demand for optometry services by society and the importance of the Optometry profession in Portugal and Spain, the objective of this study was to determine job satisfaction and important factors related to this satisfaction in a sample of Portuguese and Spanish optometrists. Methods: A prospective, cross-sectional, and observational study was carried out from June to December 2021. An adaptation of the 15-item job satisfaction in eye-care personnel (JSEP) questionnaire validated by Paudel et al. was administered to Portuguese and Spanish optometrists. The questionnaire was shared through different social media (Facebook, LinkedIn, WhatsApp, etc.) in a Google form during the months of June to December 2021 in Portugal and Spain. Results: A total of 530 surveys were collected in Portugal (42.3%; n = 224) and Spain (57.7%; n = 306). The factors that most influence overall job satisfaction are salary, career development opportunities, recognition/prestige in society, good work-life balance (all p<0.001), workplace equipment and facilities, and encouragement reward positive feedback (both p = 0.002). When comparing the determinants of job satisfaction of optometrists, it was found that Portuguese professionals were generally more satisfied than Spanish ones (p<0.001). However, Spanish optometrists reported feeling more supported by their colleagues (p<0.001). Conclusion: This study has shown that the level of job satisfaction was higher in Portugal than in Spain. The most important factors influencing job satisfaction were salary, job stability, and support from colleagues.(AU)


Subject(s)
Humans , Male , Female , Job Satisfaction , Vision, Ocular , Optometrists , Optometry , Spain , Portugal , Prospective Studies , Cross-Sectional Studies , Surveys and Questionnaires
16.
J. optom. (Internet) ; 17(2): [100489], Abr-Jun, 2024. tab, graf
Article in English | IBECS | ID: ibc-231622

ABSTRACT

Purpose: The impact of visual outcomes of cataract surgery can be measured using a questionnaire. The aim of our study was to evaluate how patient quality of life changes after cataract surgery and if there are differences between the responses of patients with nuclear, cortical, and posterior subcapsular cataracts, which has not been studied before. Method: We studied 210 cataract patients who were divided into 3 cataract groups based on their cataract type: nuclear (n = 80), cortical (n = 70), and posterior subcapsular (PSC) (n = 60). The patients completed the Visual Function Index (VF-14) questionnaire before, 2 weeks and 1 month after bilateral cataract surgery. The results were analysed using one-way ANOVA (significance level 5 %) and were compared over time and between the cataract groups. Results: Before the cataract surgery, cortical cataract patients had the lowest questionnaire score compared to nuclear and posterior subcapsular cataract groups (p = 0.08). After cataract surgery, cortical cataract patients experienced the greatest improvement in near distance daily activities, while PSC cataract patients experienced the greatest improvement in far distance daily activities (p = 0.38). Before surgery, nuclear cataract patients had the highest questionnaire scores compared to the other cataract groups (p = 0.08). Conclusion: At the 1 month follow-up, there were no statistically significant differences in questionnaire scores between the cataract groups for any of the questions. Overall, cortical cataract patients showed a trend to experience the greatest subjective improvement in quality of life after cataract removal, followed by nuclear and posterior subcapsular patients.(AU)


Subject(s)
Humans , Male , Female , Cataract/rehabilitation , Cataract Extraction , Vision, Ocular , Quality of Life , Cataract/classification , Surveys and Questionnaires , Optometry
17.
J. optom. (Internet) ; 17(2): [100488], Abr-Jun, 2024. tab, graf
Article in English | IBECS | ID: ibc-231623

ABSTRACT

Purpose: As ocular dryness and glaucoma are more prevalent with increasing age, understanding how the tear film affects tonometry is important. The present study aims to understand the impact that changes in the tear film have on intraocular pressure (IOP), corneal hysteresis, and corneal resistance factor measurements. Methods: Cross-sectional research was conducted and 37 patients were assessed. The tear film lipid layer and the non-invasive break-up time (NIBUT) were evaluated using the Tearscope Plus (Keeler, Windsor, UK). Dry eye symptoms were evaluated using the Ocular Surface Disease Index (OSDI) questionnaire. IOP was measured using rebound tonometry and the Ocular Response Analyzer (ORA, Reichert). Corneal biomechanical properties were measured using ORA. Results: It was found that an increase in the IOP measured with the iCare was directly correlated with the subclass that evaluated symptomatology associated with environmental factors (r = 0.414, p<0.05, Spearman). Goldmann-correlated IOP (IOPg) and Corneal-compensated IOP (IOPcc) values were statistically significantly different between the various interferometric patterns (p<0.05). It was also found that an increase in the corneal biomechanical properties measured with ORA was directly correlated with the overall scores obtained when using the OSDI and some of its subclasses. Conclusions: Tear film interferometric patterns were shown to have some impact on the IOP measured using ORA. The IOP measured with iCare seems to be related to the symptomatology obtained from OSDI. Corneal biomechanical properties were related to the OSDI total score and some of its subclasses. An increase in symptomatology was associated with an increase in the measured biomechanical properties of the cornea.(AU)


Subject(s)
Humans , Male , Female , Optometry , Lacrimal Apparatus , Vision, Ocular , Dry Eye Syndromes , Glaucoma , Intraocular Pressure
18.
J. optom. (Internet) ; 17(2): [100500], Abr-Jun, 2024. tab
Article in English | IBECS | ID: ibc-231624

ABSTRACT

Purpose: Visual snow syndrome (VSS) is a complex neurological condition presenting with an array of sensory, motor, and perceptual dysfunctions and related visual and non-visual symptoms. Recent laboratory studies have found subtle, basic, saccadic-based abnormalities in this population. The objective of the present investigation was to determine if saccadic-related problems could be confirmed and extended using three common clinical reading-related eye movement tests having well-developed protocols and normative databases. Methods: This was a retrospective analysis of 32 patients (ages 16–56 years) diagnosed with VSS in the first author's optometric practice. There was a battery of three reading-related tests: the Visagraph Reading Eye Movement Test, the Developmental Eye Movement (DEM) Test, and the RightEye Dynamic Vision Assessment Test, all performed using their standard documented protocols and large normative databases. Results: A high frequency of oculomotor deficits was found with all three tests. The greatest percentage was revealed with the Visagraph (56%) and the least with the RightEye (23%). A total of 77% of patients failed at least one of the three tests. Conclusion: The present findings confirm and extend earlier investigations revealing a high frequency of saccadic-based oculomotor problems in the VSS population, now including reading-related tasks. This is consistent with the more general oculomotor/motor problems found in these individuals.(AU)


Subject(s)
Humans , Male , Female , Central Nervous System Diseases/complications , Vision, Ocular , Ophthalmoplegia , Optometry , Eye Movements
19.
J. optom. (Internet) ; 17(2): [100502], Abr-Jun, 2024. graf
Article in English | IBECS | ID: ibc-231625

ABSTRACT

Background: Silicone oil is used as endotamponade following vitreoretinal surgery to maintain the retina reattached when indicated. This study investigates the hypothesis that silicone oil causes insulation effects on the retina by affecting its response to light. Methods: Electrophysiological responses to a flash stimulus were recorded using full-field electroretinography (ERG) and visual evoked potentials (VEP). Recordings were performed in 9 patients who underwent surgery for retinal detachment, before (1–2 days) and after (2–3 weeks) silicone oil removal (SOR) in both the study and the control eye. Flash ERG and VEP recordings were performed according to the ISCEV standard protocol. Results: Statistically significant differences were found in the study eye in the amplitudes of the ERG responses and their corresponding ratios, i.e. the amplitude after SOR over the amplitude before SOR, in all conditions tested. No differences were observed in the control eye. The mean ratio of photopic ERG response was 3.4 ± 2.4 for the study and 1.0 ± 0.3 for the control eye (p<0.001). The mean ratio of ERG flicker response was 3.1 ± 2.4 and 1.0 ± 0.3, respectively (p = 0.003). Scotopic flash ERG ratio was 5.0 ± 4.4 for the study and 1.3 ± 0.6 for the control eye (p = 0.012). No differences were observed for the amplitude and latency of flash VEP response after SOR. Conclusions: Silicone oil causes a reduction in flash ERG responses; no effect was found on flash VEP responses. ERGs in eyes filled with silicone oil should not be considered representative of retinal functionality, in contrast to VEPs, which are not affected by silicone oil presence.(AU)


Subject(s)
Humans , Male , Female , Retinal Detachment/surgery , Silicone Oils/administration & dosage , Silicone Oils/adverse effects , Electroretinography , Vitreoretinal Surgery , Optometry , Vision, Ocular , Retina/surgery , Evoked Potentials, Visual
20.
Curr Opin Neurobiol ; 86: 102882, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38704868

ABSTRACT

In the natural world, animals use vision for a wide variety of behaviors not reflected in most laboratory paradigms. Although mice have low-acuity vision, they use their vision for many natural behaviors, including predator avoidance, prey capture, and navigation. They also perform active sensing, moving their head and eyes to achieve behavioral goals and acquire visual information. These aspects of natural vision result in visual inputs and corresponding behavioral outputs that are outside the range of conventional vision studies but are essential aspects of visual function. Here, we review recent studies in mice that have tapped into natural behavior and active sensing to reveal the computational logic of neural circuits for vision.


Subject(s)
Behavior, Animal , Animals , Mice , Behavior, Animal/physiology , Visual Perception/physiology , Vision, Ocular/physiology , Visual Pathways/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...