Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.178
Filtrar
1.
Odontol. sanmarquina (Impr.) ; 27(3): e27759, jul-set. 2024.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1572457

RESUMEN

Odontogenic myxoma (OM) is a slow-growing, painless, aggressive and non-metastatic central jaw tumor of mesenchymal origin. Radiographically, it can vary from a unilocular radiolucent lesion to a multilocular lesion with well-defined or diffuse margins. The aim of this paper is to recognize the radiographic and tomographic characteristics of OM in a patient who attended the Dental Clinic of the Faculty of Dentistry of the Universidad Nacional Mayor de San Marcos in Lima-Peru. Case presentation: 86 year old male patient, who in the panoramic radiography indicated for his oral rehabilitation, a unilocular radiolucent image was found in the anterosuperior area with partially defined limits, corticalized edges and oval shape. In the volumetric tomography there was evidence of thinning and erosion of both bone tables, thinning of the floor of the nasal cavity. The radiolucent image seems to havean extension close to the alveolar ridge.In adition, there was an effacement of the cortices of the nasopalatine duct. The lesion was enucleated and an anatomopathological examination was performed. Diagnosis was odontogenic myxoma. The patient was evaluated at one year and six months with satisfactory results. The wide variety of radiographic characteristics of odontogenic myxoma leads us to think of a large number of differential diagnoses, being the histological evaluation together with the imaging analysis the ones that provide a definitive diagnosis. Although the anterosuperior area is the least common for its presentation, radiolucent images in this area should be considered as possible odontogenic myxomas, since this condition is more frequent in latín race.


El mixoma odontogénico (MO) es un tumor mandibular central de origen mesenquimal, de crecimiento lento, indoloro, agresivo y no metastásico. Radiográficamente, puede variar desde una lesión unilocular radiolúcida a una lesión multilocular con márgenes bien definidos o difusos. El objetivo de este trabajo es reconocer las características radiográficas y tomográficas del MO en un paciente que acudió a la Clínica Odontológica de la Facultad de Odontología de la Universidad Nacional Mayor de San Marcos en Lima-Perú. Presentación del caso: Paciente masculino de 86 años, en la radiografía panorámica indicada para rehabilitación oral, se encontró una imagen radiolúcida unilocular en la zona anterosuperior con límites parcialmente definidos, bordes corticalizados y forma ovalada. En la tomografía volumétrica se evidenció adelgazamiento y erosión de ambas tablas óseas, adelgazamiento del piso de la cavidad nasal, la imagen radiolúcida parece tener una extensión cercana a la cresta alveolar. Además, había un adelzamiento de las corticales del conducto nasopalatino. La lesión fue enucleada y se realizó un examen anatomopatológico. El diagnóstico fue mixoma odontogénico. La paciente fue evaluada al año y a los seis meses con resultados satisfactorios. La gran variedad de características radiográficas del mixoma odontogénico nos lleva a pensar en un gran número de diagnósticos diferenciales, siendo la evaluación histológica junto con el análisis de imagen los que proporcionan un diagnóstico definitivo. Aunque el área anterosuperior es la menos común para su presentación, las imágenes radiolúcidas en esta área deben ser consideradas como posibles mixomas odontogénicos, ya que esta condición es más frecuente en la raza latina.

2.
Int. j. morphol ; 42(4): 911-917, ago. 2024. ilus, tab
Artículo en Español | LILACS | ID: biblio-1569247

RESUMEN

El foramen mental, una abertura en la parte inferior de la mandíbula, es la salida de un ramo del nervio alveolar inferior, proporcionando sensibilidad a la mandíbula y la piel del mentón. Su variabilidad anatómica es importante en procedimientos dentales y quirúrgicos. Nuestro estudio en San Luis Potosí, México, examinó la posición y características morfológicas del foramen mental en una muestra de tomografías computarizadas de la mandíbula. En mujeres, la zona entre el primer y segundo premolar fue la más común, mientras que en hombres, fue la misma zona pero con mayor prevalencia en el lado izquierdo. Se observaron diferencias en la dirección del foramen mental entre sexos y lados de la mandíbula, con la dirección posterior predominante en ambos sexos. Estos hallazgos concuerdan con estudios previos en diferentes poblaciones, aunque se identifican variaciones significativas en la prevalencia y ubicación específica del foramen. La comparación con otros estudios resalta la importancia de considerar factores étnicos y geográficos en la interpretación de los resultados. Las diferencias anatómicas observadas tienen implicaciones clínicas importantes para procedimientos dentales y quirúrgicos, subrayando la necesidad de enfoques adaptados a la población específica para mejorar la precisión y seguridad de las intervenciones en el área del mentón.


SUMMARY: The mental foramen, an opening at the bottom of the jaw, is the exit of the inferior alveolar nerve branch, providing sensation to the jawbone and skin of the chin. Its anatomical variability is important in dental and surgical procedures. Our study was carried out in San Luis Potosí, Mexico and examined the position and morphological characteristics of the mental foramen in a sample of lower jaw CT scans. In women, the area between the first and second premolar was the most common, while in men, it was the same area but with a greater prevalence on the left side. Differences in the direction of the mental foramen were observed between sexes and sides of the mandible, with the posterior direction predominating in both sexes. These findings are consistent with previous studies in different populations, although significant variations in the prevalence and specific location of the foramen are identified. The comparison with other studies highlights the importance of considering ethnic and geographic factors in the interpretation of results. The anatomical differences observed have important clinical implications for dental and surgical procedures, underscoring the need for approaches tailored to the specific population to improve precision and safety of interventions in the mental foramen area.


Asunto(s)
Humanos , Masculino , Femenino , Tomografía Computarizada de Haz Cónico , Foramen Mental/diagnóstico por imagen , Estudios Transversales , Estudios Retrospectivos , Mandíbula/diagnóstico por imagen
3.
Dent Traumatol ; 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39135359

RESUMEN

AIM: To evaluate the impact of acquisition protocols and artifact reduction filters in cone beam computed tomography on diagnosing vertical root fractures in endodontically treated teeth with and without intraradicular posts. MATERIALS AND METHODS: We analyzed 480 tomographic images acquired from two J. Morita scanners (0.125- and 0.08-mm voxel sizes protocols), with application of a blooming artifact reduction filter. Three evaluators assessed these images for root fractures using a 5-point Likert scale. Diagnostic accuracy between filters and protocols was determined using generalized linear models with binomial distribution for the outcome, considering protocol, filter, and dental status. Sensitivity, specificity, positive predictive value, and negative predictive value were also estimated for the filters and protocols. RESULTS: The 0.08-mm voxel size protocol demonstrated a significantly higher percentage of accurate diagnosis compared to the 0.125-mm protocol (p = .001). No statistically significant differences (p ≥ .087) were observed for filter application, interaction between protocol and filter, or dental status. Accuracy, sensitivity, and specificity values were respectively: .93, .87, 1.00 (protocol 1); .99, .99, .99 (protocol 2); .98, .96, .99 (no filter); .95, .90, 1.00 (with filter). CONCLUSION: The new findings found for the two J Morita scanners used in our study were that images acquired using the voxel size of 0.08 mm showed an improvement in the diagnosis of root fractures and the filters in these devices have no relevance significant for the diagnosis.

4.
Iran Endod J ; 19(3): 232-236, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39086706

RESUMEN

Dens invaginatus (DI) is one of the developmental dental anomalies that results in an invagination of the enamel organ into the dental papila during odontogenesis. The purpose of this study is to report a case of nonsurgical endodontic treatment of an Oehlers type II DI in a right maxillary lateral incisor with an extensive periapical damage, along with the two-year clinical and tomographic follow-up. A 30-year-old patient was referred for endodontic treatment of tooth #12. On clinical examination, a change in the shape and color of the crown was observed. The tooth responded negative to pulp sensibility, percussion, palpation and mobility tests. After tomographic evaluation, an Oehlers type II DI was visualized, in addition to an extensive periradicular lesion. The diagnosis was asymptomatic apical periodontitis. The treatment was carried out in two sessions, through intense enhancement of the auxiliary chemical substance with passive ultrasonic irrigation, XP-Endo Finisher and the use of hydroxide-based intracanal medication. Appropriate treatment in cases with anatomic variations requires an accurate and early diagnosis based on clinical examination and radiographic images. A two-year follow-up of the present case showed that the correct diagnosis associated with appropriate instrumentation techniques, supplementary disinfection, and adequate three-dimensional sealing of the canal with filling material, resulted in regression of the periradicular lesion and bone repair.

5.
Iran Endod J ; 19(3): 223-227, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39086708

RESUMEN

Root canal obliteration is caused by hard tissue apposition and is often associated with teeth with a history of trauma, orthodontic movement, caries reaction, restorative procedures near the pulp chamber, and teeth of elderly patients. Preoperative planning of root canal treatment should be thorough and include an assessment of the patient's signs and symptoms in addition to the evaluation of complementary examinations. In a 27-year-old patient with dyschromia of the lower central incisor, a history of dental trauma, and a positive response to vertical percussion, an initial periapical radiograph was obtained that showed calcification of the canal and presence of a periapical lesion. The patient presented with pain on chewing, a positive response to palpation and a vertical percussion test. The diagnosis was symptomatic apical periodontitis. A cone-beam computed tomography scan was requested and a surface scan was performed to establish a static guide. The root canal was accessed in the middle third of the root and the canal was located using a minimally invasive approach. The root canal was treated conventionally. Results obtained showed the success of the treatment after a 3-year clinical and radiographic follow-up. Therefore, the use of an endodontic guide in cases of calcified canals significantly reduces the clinician's working time and offers a more predictable approach to the treatment of these pathologies.

6.
J Orofac Orthop ; 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39102072

RESUMEN

PURPOSE: This two-arm parallel randomized controlled trial aimed to evaluate and compare periodontal changes due to rapid maxillary expansion (RME) using tooth-bone-borne and tooth-borne devices in growing patients via clinical examinations and cone-beam computed tomography (CBCT). MATERIALS AND METHODS: Forty-two eligible patients (aged 11-14 years; transverse maxillary deficiency, posterior crossbite) were screened and divided into two groups based on the treatment received (randomization was performed using computer-generated numeric sequences): hybrid hyrax tooth-bone-borne group (TBB) and hyrax tooth-borne group (TB). The primary outcome was the change in cortical bone thickness (by CBCT). In addition, the clinical attachment level (CAL), gingival recession, and bleeding were assessed. Both examinations were performed before and 3 months after the activation phase. Intergroup comparisons were performed using analysis of covariance (ANCOVA; P < 0.05). RESULTS: Twenty-one patients (12 girls and 9 boys; mean initial age, 13.3 years) were included in the TBB group and 21 (5 girls and 16 boys; mean initial age, 13.2 years) were included in the TB group. The TB group exhibited a decrease in buccal bone thickness in the first premolars and first molars at all three evaluated levels. Specifically, tooth 14 at 3 mm from the enamel-cement junction showed a significant width reduction (0.7 mm; p < 0.001), accompanied by a notable increase in palatal cortical thickness at 6 mm of enamel-cement junction (1.13 mm; p < 0.001). CONCLUSIONS: RME resulted in buccal bone thickness reduction at the first premolar with hyrax treatment. In the molar region, both devices resulted in cortical bone alterations that were less pronounced in the TBB group.

7.
Artículo en Inglés | MEDLINE | ID: mdl-39133160

RESUMEN

OBJECTIVES: This study evaluated the impact of variations in anteroposterior and lateral tilts of patients' head on radiation-weighted doses to organs/tissues and effective doses using three different cone beam computed tomography machines. METHODS: An anthropomorphic phantom was used to estimate radiation doses in three CBCT machines (OP300, Eagle X 3D, and Eagle Edge). Thermoluminescent dosimeters were placed in regions corresponding to pre-stablished organ/tissues. CBCT examinations from the posterior mandible and anterior maxilla regions were acquired, with three different anteroposterior angulations (0°, 30°, and 45°), and from the posterior mandible in three different lateral angulations (0°, 20° to the left, and 20° to the right side). Radiation-weighted doses for each organ/tissue and effective doses were calculated for each machine and angulation. RESULTS: For the posterior mandible acquisitions, anteroposterior angulations of the head at 30° and 45° yielded a reduction in effective doses in all three devices. A 20° tilt to the right side resulted in lower doses than to the left (same side as the FOV). For the anterior maxilla, increased anteroposterior angulation was associated with reduction in effective dose in two devices. CONCLUSION: Effective doses are lower when small FOV CBCT exams of the posterior mandible and anterior maxilla are acquired with increased anteroposterior head angulation at 30° and 45°. For FOV in the posterior mandible, a 20° lateral tilt towards the side opposite to the FOV also yields lower effective doses. The main contribution to these dose reductions is the decrease in dose to salivary glands.

8.
Imaging Sci Dent ; 54(2): 139-145, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38948185

RESUMEN

Purpose: This study examined the influence of a metal artifact reduction (MAR) tool, sharpening filters, and their combination on the diagnosis of vertical root fracture (VRF) in teeth with metallic posts using cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human premolars - 9 with VRF and 11 without - were individually placed in a human mandible. A metallic post composed of a cobalt-chromium alloy was inserted into the root canal of each tooth. CBCT scans were then acquired under the following parameters: 8 mA, a 5×5 cm field of view, a voxel size of 0.085 mm, 90 kVp, and with MAR either enabled or disabled. Five oral and maxillofacial radiologists independently evaluated the CBCT exams under each MAR mode and across 3 sharpening filter conditions: no filter, Sharpen 1×, and Sharpen 2×. The diagnostic performance was quantified by the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. These metrics were compared using 2-way analysis of variance with a significance level of α=5%. Intra- and inter-examiner agreement were assessed using the weighted kappa test. Results: Neither MAR nor the application of sharpening filters significantly impacted AUC or specificity (P>0.05). However, sensitivity increased when MAR was combined with Sharpen 1× and Sharpen 2× (P=0.015). The intra-examiner agreement ranged from fair to substantial (0.34-0.66), while the inter-examiner agreement ranged from fair to moderate (0.27-0.41). Conclusion: MAR in conjunction with sharpening filters improved VRF detection; therefore, their combined use is recommended in cases of suspected VRF.

9.
Imaging Sci Dent ; 54(2): 191-199, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38948193

RESUMEN

Purpose: The aim of this study was to evaluate image artifacts in the vicinity of dental implants in cone-beam computed tomography (CBCT) scans obtained with different spatial orientations, tube current levels, and metal artifact reduction algorithm (MAR) conditions. Materials and Methods: One dental implant and 2 tubes filled with a radiopaque solution were placed in the posterior region of a mandible using a surgical guide to ensure parallel alignment. CBCT scans were acquired with the mandible in 2 spatial orientations in relation to the X-ray projection plane (standard and modified) at 3 tube current levels: 5, 8, and 11 mA. CBCT scans were repeated without the implant and were reconstructed with and without MAR. The mean voxel and noise values of each tube were obtained and compared using multi-way analysis of variance and the Tukey test (α=0.05). Results: Mean voxel values were significantly higher and noise values were significantly lower in the modified orientation than in the standard orientation (P<0.05). MAR activation and tube current levels did not show significant differences in most cases of the modified spatial orientation and in the absence of the dental implant (P>0.05). Conclusion: Modifying the spatial orientation of the head increased brightness and reduced spatial orientation noise in adjacent regions of a dental implant, with no influence from the tube current level and MAR.

10.
Imaging Sci Dent ; 54(2): 159-169, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38948188

RESUMEN

Purpose: The aim of this study was to evaluate the influence of different cone-beam computed tomography (CBCT) acquisition protocols on reducing the effective radiation dose while maintaining image quality. Materials and Methods: The effective dose emitted by a CBCT device was calculated using thermoluminescent dosimeters placed in a Rando Alderson phantom. Image quality was assessed by 3 experienced evaluators. The relationship between image quality and confidence was evaluated using the Fisher exact test, and the agreement among raters was assessed using the kappa test. Multiple linear regression analysis was performed to investigate whether the technical parameters could predict the effective dose. P-values<0.05 were considered to indicate statistical significance. Results: The optimized protocol (3 mA, 99 kVp, and 450 projection images) demonstrated good image quality and a lower effective dose for radiation-sensitive organs. Image quality and confidence had consistent values for all structures (P<0.05). Multiple linear regression analysis resulted in a statistically significant model. The milliamperage (b=0.504; t=3.406; P=0.027), kilovoltage peak (b=0.589; t=3.979; P=0.016) and number of projection images (b=0.557; t=3.762; P=0.020) were predictors of the effective dose. Conclusion: Optimized CBCT acquisition protocols can significantly reduce the effective radiation dose while maintaining acceptable image quality by adjusting the milliamperage and projection images.

11.
Dent J (Basel) ; 12(7)2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-39056999

RESUMEN

The diverse morphological configurations in teeth present clinical challenges in root canal treatment, complicating instrumentation and irrigation processes, which can lead to treatment failure. Understanding anatomical variations, such as C-shaped canals and radix entomolaris, enhances clinical skills and improves long-term endodontic treatment success rates. Cone-beam computed tomography (CBCT) offers superior diagnostic capabilities over conventional radiography, enabling the pre-operative detection of root configurations and canal numbers, facilitating personalized endodontic treatments. A total of 2173 teeth of a Mexican population, including 1057 first mandibular molars and 1116 s mandibular molars, were studied using only CBCT to identify C-shaped canals and radix configurations of patients who were treated from 2018 to 2023 at the Department of Radiology at the Faculty of Dentistry, Juarez University of the State of Durango, Mexico. C-shaped canals were identified in 160 teeth, with a prevalence of 0.2% in first mandibular molars and 14.1% in second mandibular molars. The highest frequency was in the left second mandibular molar (3.7) at 14.8%. Gender differences were significant, with higher prevalence in females (27.3%) compared to males (13.3%). The most common C-shaped canal configuration was type C2 (39.3%). Radix entomolaris was found in 52 teeth, with a prevalence of 3.4% in first mandibular molars and 1.4% in second mandibular molars. This research on a Mexican population using cone-beam computed tomography (CBCT) highlights significant findings in the prevalence and types of C-shaped canals and radix entomolaris in mandibular molars for this population. The left second mandibular molar (3.7) showed the highest prevalence at 14.8%, followed closely by the right second mandibular molar (4.7) at 13.5%, with a significant difference (p < 0.001). We found a significant difference in the prevalence of C-shaped canals between genders (p = 0.004, OR 1.78). Additionally, radix entomolaris (p < 0.001) was more frequently identified in first mandibular molars to a significant degree. These insights underscore the importance of CBCT in diagnosing complex root anatomies, which can greatly enhance the success rates of endodontic procedures by allowing for more tailored and precise treatments for this population.

12.
Artículo en Inglés | MEDLINE | ID: mdl-39072795

RESUMEN

OBJECTIVES: To evaluate the influence of multiplanar reconstruction thickness on the detection of peri-implant bone defects with a standalone zirconia implant and compare it to when another implant is in the vicinity using cone-beam computed tomography (CBCT). MATERIALS AND METHODS: Five dry human mandibles were used to create twenty implant sites in the second premolar and first molar regions. The OP300 Maxio was used to acquire CBCT images (90 kVp, 6.3 mA, 5 × 5 cm FOV, and 0.125 mm3 voxel size) before and after creating 3 mm peri-implant bone defects in the buccal aspect of the premolar region. Half of the scans featured a single zirconia implant in the premolar region, while the others had two implants in the premolar and molar regions. Three reconstruction thicknesses (0.125 mm, 1 mm, and 2 mm) were considered for the multiplanar reconstruction analyses. Five oral and maxillofacial radiologists assessed the detection of peri-implant bone defects using a 5-point scale. Diagnostic parameters were calculated and compared using Two-way ANOVA (α = .05). RESULTS: The studied factors showed no significant influence on the diagnosis of peri-implant bone defects (p > .05). Diagnostic performance was notably higher with a single implant, especially with a 2-mm reconstruction thickness (AUC = 0.88, sensitivity = 0.68, specificity = 0.94). Although the differences were not statistically significant, the results were more modest when two implants were present (AUC = 0.80, sensitivity = 0.58, specificity = 0.82). CONCLUSIONS: The presence of an adjacent zirconia implant and variations in reconstruction thickness did not influence the detection of 3 mm buccal peri-implant bone defects on CBCT images.

13.
Artículo en Inglés | MEDLINE | ID: mdl-39041319

RESUMEN

OBJECTIVE: To assess the relative position of mini-implants to retain a mandibular overdenture, according to the surgical protocol, technical and anatomical factors. METHODS: Mandibular cone-beam computed tomography (CBCT) scans were analyzed for 73 patients who received four one-piece titanium-zirconium mini-implants. Drilling was performed using a 1.6 mm needle drill and a 2.2 mm Pilot Drill, according to the bone density with a surgical stent. Post-insertion CBCT images in DICOM format were analyzed using the E-Vol-DX software with BAR filters. Divergence angle between implants and between implants and the overdenture path of insertion was measured using CliniView 10.2.6 software. RESULTS: Divergence between implants ranged from 0° to 22.3° (mean = 4.2; SD = 3.7) in the lateral and from 0° to 26.2° (mean = 5.3; SD = 4.1) in the frontal projections (p < .001). Only 1 (0.2%) and 3 (0.7%) of the measurements were higher than 20° in the lateral and frontal views, respectively. The mean angulations between the implant and the path of insertion for the overdenture were 9.3° (SD = 7.5) and 4.0° (SD = 2.9) for the lateral and frontal views, respectively (p < .001). Regression analyses showed a significant association between the divergence of implants and the frontal view projection (p < .001), greater distance between the paired implants (p = .017), the flapped surgical protocol (p = .002), higher final insertion torque (p = .011), and deeper preparation with the needle drill (p < .001). CONCLUSIONS: The mini-implants were placed with low divergence angles and satisfactory parallelism. Factors including shorter distances between the implants, higher density bone, and a flapless surgical approach all contributed positively to improved parallelism of the mini-implants.

14.
Clin Oral Investig ; 28(8): 450, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39060664

RESUMEN

OBJECTIVES: To investigate artefacts produced by different orthodontic brackets and wires in cone-beam computed tomography (CBCT) scans. MATERIALS AND METHODS: Two dental arches were made using extracted human teeth and plaster. Three pairs of acetate plates containing different brackets - metallic, ceramic, and self-ligating ceramic with NiTi clip - along with a control plate (i.e., without brackets) were prepared. Wire changes (NiTi and steel) were made during CBCT acquisitions, performed with a fixed exposure protocol. Axial slices were selected for mean gray values and standard deviation measurement in three regions of interest (buccal, lingual, and tooth). Noise and contrast-to-noise ratio (CNR) were calculated and compared among the different brackets and wires by ANOVA with a significance level of 5%. RESULTS: Overall, the buccal and tooth region were mostly affected by the metallic and self-ligating brackets, showing higher noise, and lower CNR (p < 0.05). On the other hand, less impact of ceramic brackets in the image quality was observed (p ≥ 0.05). The lingual region did not show expressive differences among the brackets and wire combinations (p ≥ 0.05). The presence of wire associated with the brackets did not worsen image quality (p ≥ 0.05). CONCLUSIONS: In conclusion, metallic and self-ligating brackets have greater artefact expression than ceramic brackets. The wire did not influence image quality. CLINICAL RELEVANCE: One should pay attention to the type of brackets when requesting a CBCT scan during treatment, as metallic and self-ligating brackets may express greater artefacts than ceramic brackets.


Asunto(s)
Artefactos , Tomografía Computarizada de Haz Cónico , Soportes Ortodóncicos , Alambres para Ortodoncia , Humanos , Técnicas In Vitro , Cerámica/química
15.
Sleep Breath ; 28(5): 2283-2294, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39046657

RESUMEN

BACKGROUND: This study aims primarily to assess the mandibular condyles and patient response to MAD therapy using cone-beam computed tomography (CBCT). Also, the study proposes to analyze whether variations in condylar position, OSA severity and mandibular protrusion influence patient response. METHODS: 23 patients diagnosed with mild/moderate OSA and treated with MAD comprised the sample. Clinical, CBCT, and PSG assessments were conducted at baseline and with MAD in therapeutic protrusion (4-6 months of MAD use). The condyle position was vertically and horizontally evaluated at baseline and at the therapeutic protrusion. RESULTS: The condyle position significantly changed with MAD, showing anterior (7.3 ± 2.8 mm; p < 0.001) and inferior (3.5 ± 1 mm; p < 0.001) displacement. Patients with mild OSA required more protrusion (p = 0.02) for improvement. Responders exhibited a significantly prominent (p = 0.04) anterior baseline condyle position. A negative modest correlation was found between treatment response and baseline condyle anterior position (p = 0.03; r=-0.4), as well as between OSA severity and the percentage of maximum protrusion needed for therapeutic protrusion (p = 0.02; r=-0.4). The patient protrusion amount did not predict condylar positional changes. Neither condyle position, OSA severity, nor therapeutic protrusion were predictors of MAD treatment response. CONCLUSION: MAD resulted in anterior and inferior condylar displacement, and the amount of protrusion did not predict condylar positional changes. Responders showed a more anterior baseline condyle position. OSA severity and mandibular protrusion did not predict treatment response.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Avance Mandibular , Cóndilo Mandibular , Apnea Obstructiva del Sueño , Humanos , Apnea Obstructiva del Sueño/terapia , Avance Mandibular/instrumentación , Cóndilo Mandibular/diagnóstico por imagen , Masculino , Femenino , Persona de Mediana Edad , Adulto , Resultado del Tratamiento , Polisomnografía
16.
J Int Soc Prev Community Dent ; 14(2): 89-97, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38827351

RESUMEN

Aim: Cone beam computed tomography has become an attractive method for implant planning. However, in most cases, not all the information is taken advantage of and often the radiographic evaluation of bone quality is based on subjective assessment by the individual clinician. Therefore, the aim of this study was to examine classifications of bone tissue characteristics and methods for assessing them in dental implant planning and placement studies. Materials and Methods: Three databases (Pubmed, Scopus, Web of Science) were searched using specific index terms: "Bone quality, bone quantity, bone density, cone-beam CT and cone-beam computed tomography". Three reviewers selected titles and analyzed abstracts according to inclusion and exclusion criteria. Some descriptions of bone tissue characteristics (bone quality, density, and quantity) used before or during dental implant placement were selected and categorized. Results: The search yielded 442 titles. A total of 32 articles were selected and read in full text. Seventeen articles were considered relevant. Different classification systems were found to evaluate bone tissue characteristics as well as different examination protocols. Thirteen publications included in this review reported on bone quality and quantity using the Lekholm and Zarb classification. However, only four studies implemented and/or proposed modifications of the Lekholm and Zarb system. Four other publications described bone quality according to different classification systems such as Misch, University of California Los Angeles (UCLA), or Trisi and Rao. The assessment methods were often briefly described (or not described at all in one publication). Of the articles analyzed, five presented observer performance, whereas three presented diagnostic accuracy of the assessment method. Conclusion: Currently, there are different classification systems applied to dental implant planning and placement, particularly regarding whether bone quality or quantity affects treatment outcomes. However, most authors have not validated the diagnostic accuracy and reproducibility of the classification used. Therefore, it is necessary to develop a classification system consistent with characteristics of bone tissue, taking into consideration an adequate description of bone tissue assessment methods, their diagnostic accuracy, and observer performance.

17.
Acta Odontol Latinoam ; 37(1): 59-67, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38920127

RESUMEN

A high prevalence of post-treatment apical periodontitis associated to variables such as endodontic treatment quality and missed canals has been reported. AIM: The aim of this study was to evalúate the quality of endodontic treatment and the frequency of missed canals associated with teeth with apicalperiodontitis (AP) through CBCTin a Colombian sub-population. MATERIAL AND METHOD: This was a cross-sectional study assessing 318 cone beam computed tomography (CBCT) scans of endodontically treated teeth from Colombian individuals. The scans were taken using J Morita X550 (J Morita Corporation, Osaka, Japan), with voxel size 0.125 to 0.20 mm. All endodontically treated teeth were assessed for quality of treatment, presence of missed canals and AP. Allsamples were analyzed bytwo endodontics specialists and an radiology specialist. Chi-square or Fisher 's test and odds ratio were calculated to identify the association and risk relationship between the presence of AP and the study variables. RESULTS: Missed canals were found in 18.61% (86/462), and 95.3% were associated with AP. The frequency of AP was 62.34% (288/462) for all the evaluated teeth. AP was found in 27.43 % (79/288) of the teeth with adequate endodontic treatment, in contrast to 72.57% (209/288) of the teeth with inadequate treatment (P<0.01). The frequency of missed canals was highest in maxillary molars, with 55.23% (58/105), with 96.55% presenting AP. The second mesiobuccal canal wasthe most frequently missed canal, 88.52%o(54/61), with AP in 90.74% (49/54) of the cases. CONCLUSIÓN: There was a high frequency of teeth with missed canals and PA. More than half of the teeth with missed canals were maxillary molars, with MB2 being the most common canal, commonly presenting apical periodontitis.


Uma alta prevalência de periodontite apical pós-tratamento associada a variáveis como qualidade do tratamento endodôntico e fracasso do tratamento é relatada na literatura. O objetivo deste estudo foi avaliar a qualidade do tratamento endodôntico e a frequência e fracasso do tratamento associados a dentes com periodontite apical (PA) por meio de tomografia computadorizada de feixe cônico (TCFC) em uma subpopulação colombiana. MATERIAL E MÉTODO: Este foi um estudo transversal que avaliou 318 tomografias computadorizadas de dentes tratados endodonticamente de indivíduos colombianos. Os exames foram realizados utilizando o tomógrafo J Morita X550, com tamanho de voxel de 0,125 a 0,20 mm. Todos os dentes tratados endodonticamente foram avaliados quanto à qualidade do tratamento, presença de canais não localizados e AP. Todas as amostras foram avaliadas por dois especialistas em endodontia e um especialista em radiologia. Foram calculados o teste qui-quadrado ou de Fisher e a razão de chances para identificar associação e relação de risco entre a presença de PA e as variáveis do estudo. RESULTADOS: Foram encontrados canais não localizados em 18,61% (86/462) e 95,3% estavam associados à PA. A frequência de AP foi de 62,34% (288/462) para todos os dentes avaliados. AP foi encontrada em 27,43% (79/288) dos dentes com tratamento endodôntico adequado, em contraste com 72,57% (209/288) dos dentes com tratamento inadequado (P<0,01). A frequência de canais não localizados foi maior nos molares superiores, com 55,23% (58/105), sendo que 96,55% apresentavam PA. O canal mésio-palatino (MB2) apresentou maior frequência de canal não localizado (88,52% - 54/61), com PA em 90,74% (49/54) dos casos. CONCLUSÃO: Houve alta frequência de dentes com canais não localizados e com PA. Mais da metade dos dentes com canais não localizados eram molares superiores, sendo o MB2 é o canal com a maior frequência, comumente apresentando periodontite apical.


Asunto(s)
Periodontitis Periapical , Tratamiento del Conducto Radicular , Humanos , Estudios Transversales , Periodontitis Periapical/diagnóstico por imagen , Periodontitis Periapical/terapia , Colombia , Femenino , Masculino , Adulto , Persona de Mediana Edad , Tomografía Computarizada de Haz Cónico , Diente no Vital/diagnóstico por imagen , Cavidad Pulpar/diagnóstico por imagen , Adulto Joven , Calidad de la Atención de Salud , Anciano
18.
Int J Legal Med ; 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38856752

RESUMEN

Investigation of the biological sex of human remains is a crucial aspect of physical anthropology. However, due to varying states of skeletal preservation, multiple approaches and structures of interest need to be explored. This research aims to investigate the potential use of distances between bifrontal breadth (FMB), infraorbital foramina distance (IOD), nasal breadth (NLB), inter-canine width (ICD), and distance between mental foramina (MFD) for combined sex prediction through traditional statistical methods and through open-access machine-learning tools. Ethical approval was obtained from the ethics committee, and out of 100 cone beam computed tomography (CBCT) scans, 54 individuals were selected with all the points visible. Ten extra exams were chosen to test the predictors developed from the learning sample. Descriptive analysis of measurements, standard deviation, and standard error were obtained. T-student and Mann-Whitney tests were utilized to assess the sex differences within the variables. A logistic regression equation was developed and tested for the investigation of the biological sex as well as decision trees, random forest, and artificial neural networks machine-learning models. The results indicate a strong correlation between the measurements and the sex of individuals. When combined, the measurements were able to predict sex using a regression formula or machine learning based models which can be exported and added to software or webpages. Considering the methods, the estimations showed an accuracy rate superior to 80% for males and 82% for females. All skulls in the test sample were accurately predicted by both statistical and machine-learning models. This exploratory study successfully established a correlation between facial measurements and the sex of individuals, validating the prediction potential of machine learning, augmenting the investigative tools available to experts with a high differentiation potential.

19.
Saudi Dent J ; 36(5): 756-760, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38868090

RESUMEN

This cross-sectional study aimed to compare, by using Cone-Beam Computed Tomography (CBCT), temporomandibular joint (TMJ) morphology among patients with degenerative joint disease (DJD) with or without arthralgia, as well as a control group. METHODS: Thirty-one patients and their respective CBCT TMJ exams were assessed. These individuals were selected from an Orofacial Pain Service and classified into three groups based on the Diagnostic Criteria for Temporomandibular Disorders (DC/TMD): group 1 (10 patients with TMJ DJD and arthralgia), group 2 (11 patients with TMJ DJD without pain), and group 3 (the control group, consisting of 10 healthy individuals without any signs or symptoms of TMD). A second examiner, who was calibrated and blinded for the patient's diagnosis, evaluated the CBCT images. RESULTS: Group 1 showed a statistically significant association with the variables of erosion (p = 0.003) and osteophyte (p = 0.04) on the condyle surface, as well as concentric condyle position with reduced joint space (p = 0.01). The Kappa concordance index between the clinical diagnosis of DC/TMD and CBCT images was k = 0.134 (p ≤ 0.001). CONCLUSION: The presence of erosion, osteophyte, and concentric condyle position with reduced joint space was statistically associated with DJD and ongoing TMJ joint pain.

20.
Int. j. morphol ; 42(3): 549-553, jun. 2024. ilus
Artículo en Inglés | LILACS | ID: biblio-1564611

RESUMEN

SUMMARY: The mandibular foramen and its canal are one of the most important structures in the skull, as they solely supply the mandible through their associated nerves and vessels. Many anatomical variations have been reported in the literature until now, and this case report represents a clear-cut appearance of its shape in a panoramic radiograph, which is not mostly seen in normal panoramic radiographs. These factors are of utmost importance when it comes to performing various surgeries and preventing complications due to their varied anatomy, which will allow dentists to create a better treatment plan and provide better treatments without any complications.


El foramen mandibular y su canal son algunas de las estructuras más importantes del cráneo y cara, ya que a través de ellos la mandíbula es inervada por nervios e irrigada por vasos. Hasta ahora, en la literatura consultada, se han informado de numerosas variaciones anatómicas. En este trabajo reportamos la forma y trayecto del foramen y canal mandibular, obtenidos en una radiografía panorámica, que no es observada normalmente en este tipo de radiografía. Los factores anatómicos son de importancia a la hora de realizar las cirugías para prevenir complicaciones debido a su variada anatomía, permitiendo a los odontólogos crear un mejor plan de tratamiento sin ningún tipo de complicaciones.


Asunto(s)
Humanos , Masculino , Adulto , Radiografía Panorámica , Variación Anatómica , Mandíbula/diagnóstico por imagen , Hallazgos Incidentales , Tomografía Computarizada de Haz Cónico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA