Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J. Phys. Educ. (Maringá) ; 34: e3435, 2023. graf
Artículo en Inglés | LILACS | ID: biblio-1528865

RESUMEN

ABSTRACT The aim of this article is to explore the basic principles of Biomechanics in relation to the objective measurements carried out by the Video Assistant Referee (VAR) operators and systems in soccer. It was presented an overall framework about the determination of kinematical variables, the definition and the sources of error, the understanding of factors contributing to errors in VAR decisions, and prospects for future solutions. To exemplify these concepts, the offside rule was chosen as it offers numerous instances of tools aiding for accurate measurements. Based on consolidated procedures of literature, a discussion about the actual challenges and an suggestions for a fully comprehension and improvement of VAR were provided.


RESUMO O objetivo deste artigo foi explorar os princípios básicos da Biomecânica em relação às medições objetivas realizadas pelos operadores e sistemas do Árbitro Assistente de Vídeo (VAR) no futebol. Foi apresentado uma estrutura geral sobre a determinação das variáveis ​​cinemáticas, a definição e as fontes de erro, a compreensão dos fatores que contribuem para os erros nas decisões do VAR e as perspectivas de soluções futuras. Para exemplificar esses conceitos, a regra do impedimento foi escolhida, pois oferece inúmeras instâncias de ferramentas que requerem medições acuradas. Com base em procedimentos consolidados da literatura, foram apresentadas discussões sobre os atuais desafios e sugestões para compreensão e aprimoramento completos do VAR.


Asunto(s)
Fenómenos Biomecánicos , Negociación , Deportes , Tecnología , Calibración , Sesgo , Instrucciones , Atletas , Visualización de Datos
2.
Ciênc. Saúde Colet. (Impr.) ; Ciênc. Saúde Colet. (Impr.);16(4): 2335-2343, abr. 2011. tab
Artículo en Portugués | LILACS | ID: lil-586582

RESUMEN

Para determinar fatores de calibração do Questionário de Frequência Alimentar para Adolescentes (QFAA), participaram do estudo 74 adolescentes de Piracicaba (SP), com idades entre 10 e 14 anos. Dados de consumo alimentar foram levantados por meio de um QFAA e dois recordatórios de 24 horas ajustados pela energia. Foram realizadas análises descritivas, análise de variância com um fator de classificação, coeficientes de correlação de Pearson e regressão linear. A média dos dois recordatórios foi utilizada como referência para calibrar os dados. Os coeficientes de calibração variaram de -0,07 (ferro) a 0,40 (vitamina C), mostrando substancial erro no método de inquérito dietético testado, mas sendo semelhantes aos observados na literatura. Devido ao fato de se apresentarem baixos, indicam a necessidade de reformulação do instrumento para alguns nutrientes, sendo desaconselhada sua aplicação para corrigir informações de ferro e retinol. A metodologia utilizada é capaz de considerar nas análises os erros de mensuração quando suas pressuposições são respeitadas, uma vez que violações desses pressupostos podem levar ao surgimento de outros erros de difícil predição.


In order to establish calibration factors of the Adolescent Food Frequency Questionnaire (AFFQ), 74 boys and girls from Piracicaba (SP, Brazil) with ages ranging from 10 to 14 took part in the study. Dietary intake (assessed by the food frequency questionnaire and 24-hour recall) was assessed and adjusted for energy intake. Descriptive statistics, variance analysis using one classification factor, Pearson's correlation coefficients and linear regression were performed. The average of two 24-hour recalls was used as a reference for calibration of data. Calibration coefficients (λ) ranged from -0.07 (iron) to 0.40 (vitamin C) revealing substantial error in the dietary method tested, albeit similar to those observed in the literature. As these coefficients were low, they indicate the need for reformulating the instrument regarding some nutrients, though application was not considered advisable for correcting information on iron and retinol. The methodology used to calibrate dietary data can consider measurement error in the assessment when its assumptions are respected, since violations of these assumptions may lead to other errors that are difficult to predict.


Asunto(s)
Adolescente , Niño , Femenino , Humanos , Masculino , Conducta Alimentaria , Encuestas y Cuestionarios
3.
Braz. j. phys. ther. (Impr.) ; 12(6): 460-467, Nov.-Dec. 2008. ilus, graf, tab
Artículo en Inglés, Portugués | LILACS | ID: lil-504887

RESUMEN

INTRODUCTION: Different sources of variations, such as electrogoniometer characteristics and procedures, may affect the accuracy and precision of movement measurements during gait. OBJECTIVE: To quantify the variations and compare the effects produced by different sources of variation in electrogoniometric gait recordings: the sensors, procedures (trials) and the knee joint. METHODS: Knee flexion/extension and valgus/varus movements were recorded during gait on the treadmill. The recordings were partitioned into strides and normalized in time using a routine developed in MatLab. Mean curves for the knee during gait were derived from 50 strides, and seven conditions were evaluated: one comparing pairs of sensors; two comparing pairs of different trials (including variations due to sensors); and four comparing the right and left knees (including variations due to sensors and trials). Mean standard deviations of the differences were calculated. To estimate the variations relating to the trial and the knee joint, the compound standard deviations were transformed into variances and split into their components. RESULTS: The variation introduced by pairs of sensors in the same model applied in one trial was smaller than the variation introduced by the same sensor used in two consecutive trials. Furthermore, the variation introduced by the difference between the right and left knees was greater than the variation introduced by the difference between sensors (A and B) and trials (1 and 2). CONCLUSIONS: It is, therefore, preferable to use different sensors in the same data recording (simultaneous) than use the same sensor in two different recordings (consecutive).


INTRODUÇÃO: Diferentes fontes de variação, tais como características do eletrogoniômetro e procedimentos podem afetar a acurácia e precisão das medidas do movimento durante a marcha. OBJETIVO: Quantificar a variação e comparar o efeito das diferentes fontes de variação nos registros eletrogoniométricos da marcha: os sensores, os procedimentos (coletas consecutivas) e a articulação do joelho. MÉTODOS: Movimentos de flexo-extensão e valgo-varo do joelho foram registrados durante a caminhada na esteira. Os registros foram divididos em passadas e normalizados no tempo usando uma rotina desenvolvida em MatLab. As curvas médias do joelho durante a marcha foram derivadas de 50 passadas, e sete condições foram avaliadas: uma para comparar dois sensores; duas para comparar duas diferentes coletas (incluindo a variação do sensor), e quatro para comparar os joelhos direito e esquerdo (incluindo a variação dos sensores e coletas). Os desvios-padrão médios das diferenças foram calculados. Para estimar as variações devido às coletas e à articulação do joelho, os desvios-padrão compostos foram transformados em variâncias e seus componentes isolados. RESULTADOS: A variação introduzida por dois sensores do mesmo modelo aplicados em uma coleta foi menor do que a variação introduzida pelo mesmo sensor usado em duas coletas consecutivas. Ainda, a variação introduzida pela diferença entre os joelhos direito e esquerdo foi maior do que a variação introduzida pela diferença entre os sensores (A e B) e as coletas (1 e 2). CONCLUSÕES: Assim, é preferível usar diferentes sensores na mesma coleta de dados (simultânea) do que usar o mesmo sensor em dois registros diferentes (consecutivos).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA