Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
2.
Crit Care ; 28(1): 142, 2024 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-38689313

RESUMO

RATIONALE: End-expiratory lung volume (EELV) is reduced in mechanically ventilated patients, especially in pathologic conditions. The resulting heterogeneous distribution of ventilation increases the risk for ventilation induced lung injury. Clinical measurement of EELV however, remains difficult. OBJECTIVE: Validation of a novel continuous capnodynamic method based on expired carbon dioxide (CO2) kinetics for measuring EELV in mechanically ventilated critically-ill patients. METHODS: Prospective study of mechanically ventilated patients scheduled for a diagnostic computed tomography exploration. Comparisons were made between absolute and corrected EELVCO2 values, the latter accounting for the amount of CO2 dissolved in lung tissue, with the reference EELV measured by computed tomography (EELVCT). Uncorrected and corrected EELVCO2 was compared with total CT volume (density compartments between - 1000 and 0 Hounsfield units (HU) and functional CT volume, including density compartments of - 1000 to - 200HU eliminating regions of increased shunt. We used comparative statistics including correlations and measurement of accuracy and precision by the Bland Altman method. MEASUREMENTS AND MAIN RESULTS: Of the 46 patients included in the final analysis, 25 had a diagnosis of ARDS (24 of which COVID-19). Both EELVCT and EELVCO2 were significantly reduced (39 and 40% respectively) when compared with theoretical values of functional residual capacity (p < 0.0001). Uncorrected EELVCO2 tended to overestimate EELVCT with a correlation r2 0.58; Bias - 285 and limits of agreement (LoA) (+ 513 to - 1083; 95% CI) ml. Agreement improved for the corrected EELVCO2 to a Bias of - 23 and LoA of (+ 763 to - 716; 95% CI) ml. The best agreement of the method was obtained by comparison of corrected EELVCO2 with functional EELVCT with a r2 of 0.59; Bias - 2.75 (+ 755 to - 761; 95% CI) ml. We did not observe major differences in the performance of the method between ARDS (most of them COVID related) and non-ARDS patients. CONCLUSION: In this first validation in critically ill patients, the capnodynamic method provided good estimates of both total and functional EELV. Bias improved after correcting EELVCO2 for extra-alveolar CO2 content when compared with CT estimated volume. If confirmed in further validations EELVCO2 may become an attractive monitoring option for continuously monitor EELV in critically ill mechanically ventilated patients. TRIAL REGISTRATION: clinicaltrials.gov (NCT04045262).


Assuntos
Capnografia , Estado Terminal , Medidas de Volume Pulmonar , Humanos , Masculino , Feminino , Estado Terminal/terapia , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso , Medidas de Volume Pulmonar/métodos , Capnografia/métodos , Respiração Artificial/métodos , COVID-19 , Tomografia Computadorizada por Raios X/métodos , Adulto
13.
Med. intensiva (Madr., Ed. impr.) ; 36(8): 531-539, nov. 2012. ilus
Artigo em Espanhol | IBECS | ID: ibc-109931

RESUMO

Objetivos: No se han podido desarrollar modelos predictores de tiempo de decanulación de pacientes traqueotomizados. El objetivo del estudio fue desarrollar variables asociadas al tiempo empleado en decanular a los pacientes, mediante la clasificación de los pacientes según la indicación de la traqueotomía (TRQ). Diseño: Estudio de cohortes prospectivo observacional. Ámbito: Dos UCI médico-quirúrgicas. Pacientes: Se incluyeron todos los pacientes traqueotomizados en UCI, excluyendo aquellos con órdenes de no resucitación, TRQ crónicas, enfermos neuromusculares o con daño cerebral. Fueron clasificados en 2 grupos: traqueotomizados por ventilación mecánica o destete prolongado (Grupo 1) y pacientes traqueotomizados por disminución del nivel de conciencia o incapacidad para manejar las secreciones respiratorias (Grupo 2). Intervenciones: Se empleó un protocolo de destete y decanulación. Variables de interés principales: Se recogieron entre otras las siguientes variables: tiempo hasta decanulación, capacidad vital y flujo espiratorio máximo, necesidades de aspiración, Glasgow (..) (AU)


Objective: Variables predicting optimal timing for tracheostomy decannulation remain unknown. We aimed to determine whether classifying patients into two groups according to their indications for tracheostomy could identify variables associated with time to decannulation. Design: A prospective, observational cohort study was carried out. Location: Two medical-surgical ICUs. Patients: We included all patients tracheostomized during ICU stay, excluding patients with do-not-resuscitate orders, tracheostomies for long-term airway control, neuromuscular disease, or neurological damage. Patients were classified into two groups: patients tracheostomized due to prolonged weaning and/or prolonged mechanical ventilation (Group 1), and patients tracheostomized due to low level of consciousness or inability to manage secretions (Group 2). Interventions: Patients were weaned and decannulated according to established protocols. Main variables: We recorded the following variables: time to tracheostomy, forced vital capacity, peak flow, suctioning requirements, Glasgow Coma Score (GCS), characteristics of respiratory secretions, and swallowing function. Statistical analyses included (..) (AU)


Assuntos
Humanos , Traqueotomia/métodos , /métodos , Respiração Artificial/métodos , Estudos Prospectivos , Fatores de Risco , Estudos de Coortes
14.
Med. intensiva (Madr., Ed. impr.) ; 36(3): 185-192, abr. 2012.
Artigo em Espanhol | IBECS | ID: ibc-103043

RESUMO

Objetivo: Evaluar la frecuencia de la trombocitopenia grave (TCPG) (<50.000/µl) en las primeras 24 horas en pacientes con síndrome de disfunción multiorgánica (SDMO) y los factores asociados a su aparición. Diseño: Estudio retrospectivo, con diseño observacional. Ámbito: Unidad de cuidados intensivos (UCI) médico-quirúrgica de un hospital de nivel III. Pacientes: Aquellos con disfunción de al menos dos órganos, según criterios SOFA; se excluyen neurocríticos y politraumatizados. Variables de interés: Antecedentes personales, medicación habitual, situación funcional basal, datos de filiación, puntuaciones de gravedad en UCI, datos de la disfunción multiorgánica, evolución UCI y datos hospitalarios. Resultados: Se incluyeron 587 pacientes. El 6,3% (37 pacientes) presentaban TCPG durante el primer día de ingreso. El 64,6% eran hombres; la mediana de edad fue 69 (56-77) años; al ingreso, SOFA 8 (5-10); APACHE II 18 (13-24); APACHE IV 59 (46-73); 32,5% son quirúrgicos. Durante su evolución 79,9% necesitaron ventilación mecánica y el 71,4% requirió fármacos vasoactivos. Estancia en UCI 4 (2-10) días; estancia hospitalaria 18 (9-35) días. El 29,2% fallecieron en UCI. El 11,7% desarrollaron durante su ingreso en UCI TCPG. En el análisis multivariable los principales determinantes de la aparición de la trombocitopenia al ingreso fueron los antecedentes de ingreso hospitalario en el último año, el peor valor de bilirrubina y albúmina sanguínea y la sepsis. Conclusión: La prevalencia de TCPG en pacientes críticos con SDMO durante el primer día de estancia en UCI es del 6,3%. Los factores asociados son: la presencia o no de ingresos hospitalarios en el último año, los niveles de albúmina y bilirrubina y la sepsis (AU)


Objective: To evaluate the frequency of severe thrombocytopenia (STCP) (< 50.000/µl) in the first 24hours in patients with multiple organ dysfunction syndrome, and the factors that influence its occurrence. Design: A retrospective, observational study. Area: Medical-surgical intensive care unit (ICU). Tertiary hospital. Patients: Those with failure of at least two organs, according to SOFA criteria, with the exclusion of neurological and traumatologic critical cases. Variables: Medical history, regular medication, baseline functional status, demographic variables, severity scores in ICU, multiple-organ failure data, course in ICU and main hospital data. Results: A total of 587 patients were included; 6.3% (37 patients) presented with STCP during the first day of admission; 64.6% were men; SOFA 8 (5-10); APACHE II 18 (13-24); APACHE IV 59 (46-73); 32.5% were surgical patients. A total of 79.9% subsequently needed mechanical ventilation, and 71.4% required vasoactive drugs. Overall stay in ICU: 4 (2-10) days, main hospital stay 18 (9-35) days. A total of 29.2% died in the ICU; 11.7% developed STCP during admission to the ICU. Multivariate analysis found the main determining factors in the occurrence of thrombocytopenia on admission to be: history of hospitalization in the last year, albumin and bilirubin levels, and sepsis. Conclusion: The prevalence of STCP among critical patients was 6.3%. Its occurrence was associated with albumin and bilirubin levels, sepsis, and with patient admittance in the last year (AU)


Assuntos
Humanos , Trombocitopenia/epidemiologia , Insuficiência de Múltiplos Órgãos/complicações , Sepse/epidemiologia , Estudos Retrospectivos , Cuidados Críticos/métodos , Fatores de Risco
15.
Med Intensiva ; 36(8): 531-9, 2012 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-22398327

RESUMO

OBJECTIVE: Variables predicting optimal timing for tracheostomy decannulation remain unknown. We aimed to determine whether classifying patients into two groups according to their indications for tracheostomy could identify variables associated with time to decannulation. DESIGN: A prospective, observational cohort study was carried out. LOCATION: Two medical-surgical ICUs. PATIENTS: We included all patients tracheostomized during ICU stay, excluding patients with do-not-resuscitate orders, tracheostomies for long-term airway control, neuromuscular disease, or neurological damage. Patients were classified into two groups: patients tracheostomized due to prolonged weaning and/or prolonged mechanical ventilation (Group 1), and patients tracheostomized due to low level of consciousness or inability to manage secretions (Group 2). INTERVENTIONS: Patients were weaned and decannulated according to established protocols. MAIN VARIABLES: We recorded the following variables: time to tracheostomy, forced vital capacity, peak flow, suctioning requirements, Glasgow Coma Score (GCS), characteristics of respiratory secretions, and swallowing function. Statistical analyses included Cox-proportional multivariate analysis with time to decannulation as the dependent variable. RESULTS: A total of 227 patients were tracheostomized in the ICUs; of these, 151 were finally included in the study. In the multivariate analysis, time to decannulation in Group 1 was associated with the male gender (HR 1.74 (1.04-2.89), p= 0.03), age>60 years (HR 0.58 (0.36-0.91), p= 0.02), high suctioning frequency (HR 0.81 (0.67-0.97), p= 0.02), low forced vital capacity (HR 0.48 (0.28-0.82), p<0.01), and low peak flow (HR 0.25 (0.14-0.46), p<0.01). In Group 2 time to decannulation was associated to GCS >13 (HR 2.73 (1.51-4.91), p<0.01), high suctioning frequency (HR 0.7 (0.54-0.91), p<0.01), and inadequate swallowing (HR 1.97 (1.11-3.52), p=0.02). CONCLUSION: Variables associated with longer time to decannulation in ICU-tracheostomized patients differ with the indications for tracheostomy.


Assuntos
Estado Terminal/classificação , Traqueostomia , Traqueotomia , Desmame do Respirador , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Fatores de Tempo
16.
Med Intensiva ; 36(3): 185-92, 2012 Apr.
Artigo em Espanhol | MEDLINE | ID: mdl-22296738

RESUMO

OBJECTIVE: To evaluate the frequency of severe thrombocytopenia (STCP) (≤ 50,000/µl) in the first 24 hours in patients with multiple organ dysfunction syndrome, and the factors that influence its occurrence. DESIGN: A retrospective, observational study. AREA: Medical-surgical intensive care unit (ICU). Tertiary hospital. PATIENTS: Those with failure of at least two organs, according to SOFA criteria, with the exclusion of neurological and traumatologic critical cases. VARIABLES: Medical history, regular medication, baseline functional status, demographic variables, severity scores in ICU, multiple-organ failure data, course in ICU and main hospital data. RESULTS: A total of 587 patients were included; 6.3% (37 patients) presented with STCP during the first day of admission; 64.6% were men; SOFA 8 (5-10); APACHE II 18 (13-24); APACHE IV 59 (46-73); 32.5% were surgical patients. A total of 79.9% subsequently needed mechanical ventilation, and 71.4% required vasoactive drugs. Overall stay in ICU: 4 (2-10) days, main hospital stay 18 (9-35) days. A total of 29.2% died in the ICU; 11.7% developed STCP during admission to the ICU. Multivariate analysis found the main determining factors in the occurrence of thrombocytopenia on admission to be: history of hospitalization in the last year, albumin and bilirubin levels, and sepsis. CONCLUSION: The prevalence of STCP among critical patients was 6.3%. Its occurrence was associated with albumin and bilirubin levels, sepsis, and with patient admittance in the last year.


Assuntos
Unidades de Terapia Intensiva/estatística & dados numéricos , Insuficiência de Múltiplos Órgãos/sangue , Trombocitopenia/epidemiologia , APACHE , Idoso , Bilirrubina/sangue , Grupos Diagnósticos Relacionados , Uso de Medicamentos , Feminino , Mortalidade Hospitalar , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Insuficiência de Múltiplos Órgãos/complicações , Insuficiência de Múltiplos Órgãos/epidemiologia , Readmissão do Paciente/estatística & dados numéricos , Contagem de Plaquetas , Complicações Pós-Operatórias/epidemiologia , Prevalência , Estudos Retrospectivos , Sepse/sangue , Sepse/epidemiologia , Espanha/epidemiologia , Trombocitopenia/etiologia
19.
Med. intensiva (Madr., Ed. impr.) ; 34(5): 303-309, jun.-jul. 2010. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-84045

RESUMO

Objetivo: Analizar el rendimiento de la estimulación con marcapasos de modalidad VDD en pacientes con bloqueo auriculo-ventricular (AV) completo con especial atención a la permanencia en sincronía AV. Diseño: Se trata de un estudio retrospectivo observacional, descriptivo sobre una serie de casos. Ámbito: Servicio de Medicina Intensiva de un centro hospitalario de tercer nivel. Pacientes: Totalidad de pacientes con marcapasos VDD implantado entre 1994-2008. Variables: Se analizó causa de trastorno del ritmo, tiempo de mantenimiento de la sincronía AV, motivo de la pérdida de la misma, número de recambios de generador y motivo, edad a la que se hizo el primoimplante, incidencia de fallo de sensado auricular y de fibrilación auricular. Se comparó la población que entro en Fibrilación auricular con el resto que mantenían actividad auricular. Resultados: Se analizaron 95 pacientes, 49 (51,6%) varones y 46 (48,4%) mujeres con edad media de Edad 77,08±8,37 años. El síntoma más frecuente fue el presíncope y mareo con 43 casos (45,3%), el trastorno del ritmo más frecuente fue el bloqueo AV de IIIo con QRS ancho con 68 casos (71,6%). El tiempo medio de Sincronía AV mantenida fue de 73,01±4,2 meses, sin diferencias significativas entre diferentes causas de pérdida de la misma. Al final del estudio permanecían en sincronía AV estudio 56 casos (73,3%). Conclusiones: El tiempo de sincronía AV es elevado, siendo las causas más importantes de su pérdida, la entrada en fibrilación auricular y el infrasensado auricular (AU)


Objective: To analyze the performance of VDD mode pacing in patients with complete AV block with special attention on maintaining AV synchrony. Design: This is a descriptive, retrospective and observational study of a case series. Setting: Intensive Medicine Department of a tertiary Hospital. Patients: All patients with VDD pacemakers implanted between 1994 and 2008. Main measurements: The cause of the rhythm disorder, time of atrioventricular synchrony, cause of its loss, number of pacemaker replacement and reason, age when the first implant was performed, incidence of failure of atrial sensing and atrial fibrillation. We compared patients with atrial fibrillation with the rest who maintained normal atrial activity. Results: A total of 95 patients, 49 (51.6%) males and 46 (48.4%) female with mean age of 77.08±8.37 years, were analyzed. The most common symptom was dizziness and presyncope in 43 cases (45.3%), the most common rhythm disorder was the III AV block with wide QRS with 68 cases (71.6%). Average time of AV synchrony was maintained 73.01±4.2 months with no significant differences between different causes of synchrony loss. At the end of the study, 56 cases remained in AV synchrony (73.3%). Conclusions: The preservation time of AV synchrony is high, the most important causes of loss being entry in atrial fibrillation and atrial infrasensing (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Marca-Passo Artificial , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/terapia , Estudos Retrospectivos , Fatores de Tempo
20.
Med Intensiva ; 34(5): 303-9, 2010.
Artigo em Espanhol | MEDLINE | ID: mdl-20227795

RESUMO

OBJECTIVE: To analyze the performance of VDD mode pacing in patients with complete AV block with special attention on maintaining AV synchrony. DESIGN: This is a descriptive, retrospective and observational study of a case series. SETTING: Intensive Medicine Department of a tertiary hospital. PATIENTS: All patients with VDD pacemakers implanted between 1994 and 2008. MAIN MEASUREMENTS: The cause of the rhythm disorder, time of atrioventricular synchrony, cause of its loss, number of pacemaker replacement and reason, age when the first implant was performed, incidence of failure of atrial sensing and atrial fibrillation. We compared patients with atrial fibrillation with the rest who maintained normal atrial activity. RESULTS: A total of 95 patients, 49 (51.6%) males and 46 (48.4%) female with mean age of 77.08+/-8.37 years, were analyzed. The most common symptom was dizziness and presyncope in 43 cases (45.3%), the most common rhythm disorder was the III AV block with wide QRS with 68 cases (71.6%). Average time of AV synchrony was maintained 73.01+/-4.2 months with no significant differences between different causes of synchrony loss. At the end of the study, 56 cases remained in AV synchrony (73.3%). CONCLUSIONS: The preservation time of AV synchrony is high, the most important causes of loss being entry in atrial fibrillation and atrial infrasensing.


Assuntos
Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/terapia , Marca-Passo Artificial , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...