Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-21254974

RESUMO

ObjectivesTo assess the diagnostic performance of lung point-of-care ultrasound (POCUS) compared to either a positive nucleic acid test (NAT) or a COVID-19-typical pattern on computed tomography (CT) and to evaluate opportunities to simplify a POCUS algorithm. MethodsHospital-admitted adult inpatients with (1) either confirmed or suspected COVID-19 and (2) a completed or ordered CT within the preceding 24 hours were recruited. Twelve lung zones were scanned with a handheld POCUS machine. POCUS, CT, and X-ray (CXR) images were reviewed independently by blinded experts. A simplified POCUS algorithm was developed via machine learning. ResultsOf 79 enrolled subjects, 26.6% had a positive NAT and 31.6% had a CT typical for COVID-19. The receiver operator curve (ROC) for a 12-zone POCUS protocol had an area under the curve (AUC) of 0.787 for positive NAT and 0.820 for typical CT. A simplified four-zone protocol had an AUC of 0.862 for typical CT and 0.862 for positive NAT. CT had an AUC of 0.815 for positive NAT; CXR had AUCs of 0.793 for positive NAT and 0.733 for typical CT. Performance of the four-zone protocol was superior to CXR for positive NAT (p=0.0471). Using a two-point cutoff system, the four-zone POCUS protocol had a sensitivity of 0.920 and 0.904 compared to CT and NAT, respectively, at the lower cutoff; it had a specificity of 0.926 and 0.948 at the higher cutoff, respectively. ConclusionPOCUS outperformed CXR to predict positive NAT. POCUS could potentially replace other chest imaging for persons under investigation for COVID-19.

2.
Chinese Journal of Traumatology ; (6): 284-287, 2012.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-325778

RESUMO

<p><b>OBJECTIVE</b>To examine the utility of bedside echocardiography in detecting the reversible causes of pulseless electrical activity (PEA) cardiac arrest and predicting the resuscitation outcomes.</p><p><b>METHODS</b>In this prospective interventional study, patients presenting with PEA cardiac arrest were randomized into two groups. In Group A, ultrasound trained emergency physicians performed echocardiography evaluating cardiac activity, right ventricle dilation, left ventricle function, pericardial effusion/tamponade and IVC size along with the advanced cardiac life support (ACLS) protocol. Patients in Group B solely underwent ACLS protocol without applying echocardiography. The presence or absence of mechanical ventricular activity (MVA) and evidences of PEA reversible causes were recorded. The return of spontaneous circulation (ROSC) and death were evaluated in both groups.</p><p><b>RESULTS</b>One hundred patients with the mean age of (58+/-6.1) years were enrolled in this study. Fifty patients (Group A) had echocardiography detected in parallel with cardiopulmonary resuscitation (CPR). Among them, 7 patients (14%) had pericardial effusion, 11 (22%) had hypovolemia, and 39 (78%) were revealed the presence of MVA. In the pseudo PEA subgroup (presence of MVA), 43% had ROSC (positive predictive value) and in the true PEA subgroup with cardiac standstill (absence of MVA), there was no recorded ROSC (negative predictive value). Among patients in Group B, no reversible etiology was detected. There was no significant difference in resuscitation results between Groups A and B observed (P equal to 0.52).</p><p><b>CONCLUSION</b>Bedside echocardiography can identify some reversible causes of PEA. However, there are no significant changes in survival outcome between the echo group and those with traditional CPR.</p>


Assuntos
Humanos , Reanimação Cardiopulmonar , Ecocardiografia , Parada Cardíaca , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...