Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.030
Filtrar
1.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38970395

RESUMO

AIMS: Although electrical activity of the normal human heart is well characterized by the electrocardiogram, detailed insights into within-subject and between-subject variations of ventricular activation and recovery by noninvasive electroanatomic mapping are lacking. We characterized human epicardial activation and recovery within and between normal subjects using non-invasive electrocardiographic imaging (ECGI) as a basis to better understand pathology. METHODS AND RESULTS: Epicardial activation and recovery were assessed by ECGI in 22 normal subjects, 4 subjects with bundle branch block (BBB) and 4 with long-QT syndrome (LQTS). We compared characteristics between the ventricles [left ventricle (LV) and right ventricle (RV)], sexes, and age groups (<50/≥50years). Pearson's correlation coefficient (CC) was used for within-subject and between-subject comparisons. Age of normal subjects averaged 49 ± 14 years, 6/22 were male, and no structural/electrical heart disease was present. The average activation time was longer in LV than in RV, but not different by sex or age. Electrical recovery was similar for the ventricles, but started earlier and was on average shorter in males. Median CCs of between-subject comparisons of the ECG signals, activation, and recovery patterns were 0.61, 0.32, and 0.19, respectively. Within-subject beat-to-beat comparisons yielded higher CCs (0.98, 0.89, and 0.82, respectively). Activation and/or recovery patterns of patients with BBB or LQTS contrasted significantly with those found in the normal population. CONCLUSION: Activation and recovery patterns vary profoundly between normal subjects, but are stable individually beat to beat, with a male preponderance to shorter recovery. Individual characterization by ECGI at baseline serves as reference to better understand the emergence, progression, and treatment of electrical heart disease.


Assuntos
Potenciais de Ação , Bloqueio de Ramo , Eletrocardiografia , Síndrome do QT Longo , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/diagnóstico , Síndrome do QT Longo/fisiopatologia , Síndrome do QT Longo/diagnóstico , Frequência Cardíaca , Valor Preditivo dos Testes , Idoso , Estudos de Casos e Controles , Fatores de Tempo , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Fatores Etários , Mapeamento Epicárdico
2.
Acta Med Indones ; 56(2): 227-232, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-39010770

RESUMO

Left bundle branch pacing (LBBP) has been subject to increasing interest over the last few years due to its capacity for physiological conduction and its advantages compared to His bundle pacing. His bundle pacing has certain limitations, such as a small pacing area for the His bundle, a high threshold that leads to battery depletion, a low R-wave amplitude that may result in atrial or His oversensing, and ventricular signal undersensing. In this case series, four patients (two female and two male) aged 62.2 ± 8.4 years old with symptomatic sick sinus disease and no scar tissue in the interventricular septum underwent LBBP. All LBBPs were done with standard LBBP using a lumenless SelectSecure 3830 lead (Medtronic®, Minneapolis, USA) with a fixed helix. The lead parameters showed a good R-wave amplitudes (13 ± 7.4 mV) and a low threshold  (0.77 ± 0.17 V @ 0.4 ms). All patients were discharged on the next day. During follow-up period of 13.3 ± 12.9 months, all patients were well and no complications were noted. In conclusion, LBBP may be as an alternative of novel conduction pacing techniques and can be done relatively easy and safe, even with limited experience center.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Eletrocardiografia , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Fascículo Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Idoso , Síndrome do Nó Sinusal/terapia , Resultado do Tratamento , Marca-Passo Artificial , Bloqueio de Ramo/terapia , Bloqueio de Ramo/fisiopatologia
3.
Scand Cardiovasc J ; 58(1): 2373090, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38957080

RESUMO

OBJECTIVES: Electrocardiogram (ECG) and measurement of plasma brain natriuretic peptides (BNP) are established markers of right ventricular dysfunction (RVD) in the setting of acute pulmonary embolism (PE) but their value at long-term follow-up is largely unknown. The purpose of this prospective study was to determine the prevalence of ECG abnormalities, describe levels of N-terminal proBNP (NT-proBNP), and establish their association with dyspnea at long-term follow-up after PE. DESIGN: All Swedish patients diagnosed with acute PE in 2005 (n = 5793) were identified through the Swedish National Patient Registry. Surviving patients in 2007 (n = 3510) were invited to participate. Of these, 2105 subjects responded to a questionnaire about dyspnea and comorbidities. Subjects with dyspnea or risk factors for development of chronic thromboembolic pulmonary hypertension were included in the study in a secondary step, which involved collection of blood samples and ECG registration. RESULTS: Altogether 49.3% had a completely normal ECG. The remaining participants had a variety of abnormalities, 7.2% had atrial fibrillation/flutter (AF). ECG with any sign of RVD was found in 7.2% of subjects. Right bundle branch block was the most common RVD sign with a prevalence of 6.4%. An abnormal ECG was associated with dyspnea. AF was associated with dyspnea, whereas ECG signs of RVD were not. 61.2% of subjects had NT-proBNP levels above clinical cut-off (>125 ng/L). The degree of dyspnea did not associate independently with NT-proBNP levels. CONCLUSIONS: We conclude that the value of ECG and NT-proBNP in long term follow-up after PE lies mostly in differential diagnostics.


Assuntos
Biomarcadores , Dispneia , Eletrocardiografia , Peptídeo Natriurético Encefálico , Fragmentos de Peptídeos , Valor Preditivo dos Testes , Embolia Pulmonar , Sistema de Registros , Humanos , Embolia Pulmonar/sangue , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/epidemiologia , Embolia Pulmonar/fisiopatologia , Fragmentos de Peptídeos/sangue , Masculino , Feminino , Peptídeo Natriurético Encefálico/sangue , Suécia/epidemiologia , Biomarcadores/sangue , Idoso , Estudos Prospectivos , Dispneia/sangue , Dispneia/diagnóstico , Dispneia/epidemiologia , Dispneia/fisiopatologia , Dispneia/etiologia , Pessoa de Meia-Idade , Fatores de Tempo , Prevalência , Disfunção Ventricular Direita/sangue , Disfunção Ventricular Direita/fisiopatologia , Disfunção Ventricular Direita/diagnóstico , Disfunção Ventricular Direita/etiologia , Fatores de Risco , Idoso de 80 Anos ou mais , Prognóstico , Função Ventricular Direita , Bloqueio de Ramo/sangue , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/fisiopatologia
5.
Echocardiography ; 41(6): e15864, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38889092

RESUMO

This systematic review investigates the diagnostic and prognostic utility of coronary flow reserve (CFR) assessment through echocardiography in patients with left bundle branch block (LBBB), a condition known to complicate the clinical evaluation of coronary artery disease (CAD). The literature search was performed on PubMed, EMBASE, Web of Science, Scopus, and Google Scholar, was guided by PRISMA standards up to March 2024, and yielded six observational studies that met inclusion criteria. These studies involved a diverse population of patients with LBBB, employing echocardiographic protocols to clarify the impact of LBBB on coronary flow dynamics. The findings emphasize the importance of CFR in stratifying cardiovascular risk and guiding clinical decision-making in patients with LBBB. Pooled results reveal that patients with LBBB and significant left anterior descending (LAD) artery stenosis exhibited a marked decrease in stress-peak diastolic velocity (MD = -19.03 [-23.58; -14.48] cm/s; p < .0001) and CFR (MD = -.60 [-.71; -.50]; p < .0001), compared to those without significant LAD lesions, suggesting the efficacy of stress echocardiography CFR assessment in the identification of clinically significant CAD among the LBBB population. This review highlights the clinical relevance of echocardiography CFR assessment as a noninvasive tool for evaluating CAD and stratifying risk in the presence of LBBB and underscores the need for standardized protocols in CFR measurement.


Assuntos
Bloqueio de Ramo , Circulação Coronária , Ecocardiografia , Humanos , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/complicações , Circulação Coronária/fisiologia , Ecocardiografia/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/complicações , Velocidade do Fluxo Sanguíneo/fisiologia , Vasos Coronários/fisiopatologia , Vasos Coronários/diagnóstico por imagem
6.
Am J Cardiol ; 224: 26-35, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38844197

RESUMO

New-generation transcatheter heart valves have significantly improved technical success and procedural safety of transcatheter aortic valve implantation (TAVI) procedures; however, the incidence of permanent pacemaker implantation (PPI) remains a concern. This study aimed to assess the role of anatomic annulus features in determining periprocedural conduction disturbances leading to new PPI after TAVI using the last-generation Edwards SAPIEN balloon-expandable valves. In the context of a prospective single-center registry, we integrated the clinical and procedural predictors of PPI with anatomic data derived from multislice computed tomography. A total of 210 consecutive patients treated with balloon-expandable Edwards transcatheter heart valve were included in the study from 2015 to 2023. Technical success was achieved in 197 procedures (93.8%), and 26 patients (12.4%) required new PPI at the 30-day follow-up (median time to implantation 3 days). At the univariable logistic regression analysis, preprocedural right bundle branch block (odds ratio [OR] 2.24, 95% confidence interval [CI] 1.01 to 4.97, p = 0.047), annulus eccentricity ≥0.25 (OR 5.43, 95% CI 2.21 to 13.36, p <0.001), calcium volume at annulus of the right coronary cusp >48 mm3 (OR 2.60, 95% CI 1.13 to 5.96, p = 0.024), and prosthesis implantation depth greater than membranous septum length (OR 2.17, 95% CI 1.10 to 4.28, p = 0.026) were associated with new PPI risk. In the multivariable analysis, preprocedural right bundle branch block (OR 2.81, 95% CI 1.01 to 7.85, p = 0.049), annulus eccentricity ≥0.25 (OR 4.14, 95% CI 1.85 to 9.27, p <0.001), and annulusright coronary cusp calcium >48 mm3 (OR 2.89, 95% CI 1.07 to 7.82, p = 0.037) were confirmed as independent predictors of new PPI. In conclusion, specific anatomic features of the aortic valve annulus might have an additive role in determining the occurrence of conduction disturbances in patients who underwent TAVI with balloon-expandable valves. This suggests the possibility to use multislice computed tomography to improve the prediction of post-TAVI new PPI risk.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Tomografia Computadorizada Multidetectores , Marca-Passo Artificial , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Tomografia Computadorizada Multidetectores/métodos , Estudos Prospectivos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Idoso , Complicações Pós-Operatórias/epidemiologia , Fatores de Risco , Bloqueio de Ramo/terapia , Bloqueio de Ramo/etiologia , Sistema de Registros
7.
J Am Heart Assoc ; 13(12): e035279, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38879456

RESUMO

BACKGROUND: Studies have reported that female sex predicts superior cardiac resynchronization therapy (CRT) response. One theory is that this association is related to smaller female heart size, thus increased relative dyssynchrony at a given QRS duration (QRSd). Our objective was to investigate the mechanisms of sex-specific CRT response relating to heart size, relative dyssynchrony, cardiomyopathy type, QRS morphology, and other patient characteristics. METHODS AND RESULTS: This is a post hoc analysis of the MORE-CRT MPP (More Response on Cardiac Resynchronization Therapy with Multipoint Pacing)  trial (n=3739, 28% women), with a subgroup analysis of patients with nonischemic cardiomyopathy and left bundle-branch block (n=1308, 41% women) to control for confounding characteristics. A multivariable analysis examined predictors of response to 6 months of conventional CRT, including sex and relative dyssynchrony, measured by QRSd/left ventricular end-diastolic volume (LVEDV). Women had a higher CRT response rate than men (70.1% versus 56.8%, P<0.0001). In subgroup analysis, regression analysis of the nonischemic cardiomyopathy left bundle-branch block subgroup identified QRSd/LVEDV, but not sex, as a modifier of CRT response (P<0.0039). QRSd/LVEDV was significantly higher in women (0.919) versus men (0.708, P<0.001). CRT response was 78% for female patients with QRSd/LVEDV greater than the median value, compared with 68% with QRSd/LVEDV less than the median value (P=0.012). The association between CRT response and QRSd/LVEDV was strongest at QRSd <150 ms. CONCLUSIONS: In the nonischemic cardiomyopathy left bundle-branch block population, increased relative dyssynchrony in women, who have smaller heart sizes than their male counterparts, is a driver of sex-specific CRT response, particularly at QRSd <150 ms. Women may benefit from CRT at a QRSd <130 ms, opening the debate on whether sex-specific QRSd cutoffs or QRS/LVEDV measurement should be incorporated into clinical guidelines.


Assuntos
Bloqueio de Ramo , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Feminino , Masculino , Idoso , Fatores Sexuais , Pessoa de Meia-Idade , Resultado do Tratamento , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico , Bloqueio de Ramo/terapia , Bloqueio de Ramo/fisiopatologia , Cardiomiopatias/fisiopatologia , Cardiomiopatias/terapia , Cardiomiopatias/diagnóstico , Tamanho do Órgão , Função Ventricular Esquerda/fisiologia , Volume Sistólico/fisiologia , Coração/fisiopatologia , Eletrocardiografia
8.
J Cardiovasc Med (Hagerstown) ; 25(7): 551-558, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38809231

RESUMO

AIMS: In patients undergoing pacemaker implantation with no prior history of heart failure (HF), the presence of left bundle branch block (LBBB) has been identified as an independent predictor of HF-related death or hospitalization, while the prognostic significance of right bundle branch block (RBBB) remains uncertain. We aimed to assess the long-term risk of all-cause mortality in patients with a standard indication for permanent pacing and normal or moderately depressed left ventricular function when RBBB is detected at the time of implantation. METHODS: We retrospectively enrolled 1348 consecutive patients who had undergone single- or dual-chamber pacemaker implantation at the study center, from January 1990 to December 2022. Patients with a left ventricular ejection fraction ≤35% or a prior diagnosis of HF were excluded. RESULTS: The baseline 12-lead electrocardiogram revealed an RBBB in 241 (18%) and an LBBB in 98 (7%) patients. During a median follow-up of 65 [25th-75th percentile: 32-117] months, 704 (52%) patients died. The combined endpoint of cardiovascular death or HF hospitalization was reached by 173 (13%) patients. On multivariate analysis, RBBB was confirmed as an independent predictor of death [hazard ratio, 1.33; 95% confidence interval (CI), 1.09-1.63; P  = 0.005]. However, when considering the combined endpoint of cardiovascular death and HF hospitalization, this endpoint was independently associated with LBBB (hazard ratio, 2.13; 95% CI, 1.38-3.29; P  < 0.001), but not with RBBB. CONCLUSION: In patients with standard pacemaker indications and normal or moderately depressed left ventricular function, the presence of basal RBBB was an independent predictor of mortality. However, it was not associated with the combined endpoint of cardiovascular death and HF hospitalization.


Assuntos
Bloqueio de Ramo , Eletrocardiografia , Marca-Passo Artificial , Humanos , Bloqueio de Ramo/terapia , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/mortalidade , Bloqueio de Ramo/diagnóstico , Masculino , Feminino , Idoso , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Estimulação Cardíaca Artificial/mortalidade , Fatores de Risco , Função Ventricular Esquerda , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Fatores de Tempo , Hospitalização/estatística & dados numéricos , Pessoa de Meia-Idade , Prognóstico , Medição de Risco/métodos , Resultado do Tratamento , Relevância Clínica
9.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38703372

RESUMO

AIMS: To characterize the diagnosis, frequency, and procedural implications of septal venous channel perforation during left bundle branch area pacing (LBBAP). METHODS AND RESULTS: All consecutive patients undergoing LBBAP over an 8-month period were prospectively studied. During lead placement, obligatory septal contrast injection was performed twice, at initiation (implant entry zone) and at completion (fixation zone). An intuitive fluoroscopic schema using orthogonal views (left anterior oblique/right anterior oblique) and familiar landmarks is described. Using this, we resolved zonal distribution (I-VI) of lead position on the ventricular septum and its angulation (post-fixation angle θ). Subjects with and without septal venous channel perforation were compared. Sixty-one patients {male 57.3%, median age [interquartile range (IQR)] 69.5 [62.5-74.5] years} were enrolled. Septal venous channel perforation was observed in eight (13.1%) patients [male 28.5%, median age (IQR) 64 (50-75) years]. They had higher frequency of (i) right-sided implant (25% vs. 1.9%, P = 0.04), (ii) fixation in zone III at the mid-superior septum (75% vs. 28.3%, P = 0.04), (iii) steeper angle of fixation-median θ (IQR) [19 (10-30)° vs. 5 (4-19)°, P = 0.01], and (iv) longer median penetrated-lead length (IQR) [13 (10-14.8) vs. 10 (8.5-12.5) mm, P = 0.03]. Coronary sinus drainage of contrast was noted in five (62.5%) patients. Abnormal impedance drops during implantation (12.5% vs. 5.7%, P = NS) were not significantly different. CONCLUSION: When evaluated systematically, septal venous channel perforation may be encountered commonly after LBBAP. The fiducial reference framework described using fluoroscopic imaging identified salient associated findings. This may be addressed with lead repositioning to a more inferior location and is not associated with adverse consequence acutely or in early follow-up.


Assuntos
Estimulação Cardíaca Artificial , Humanos , Masculino , Feminino , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso , Estimulação Cardíaca Artificial/métodos , Septo Interventricular/diagnóstico por imagem , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/diagnóstico por imagem , Resultado do Tratamento , Fatores de Risco , Fascículo Atrioventricular/fisiopatologia , Septos Cardíacos/diagnóstico por imagem , Meios de Contraste , Fluoroscopia , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/etiologia
10.
J Electrocardiol ; 84: 161-164, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38733733

RESUMO

Since the introduction of left bundle branch pacing (LBBP), a search for precise parameters confirming successful capture of conduction system was conducted. Most of the proposed electrocardiographic criteria refer to patients with narrow QRS complexes. We present a patient with heart failure in whom cardiac resynchronization was achieved using conduction system pacing. While measuring left ventricular activation time, an isoelectric interval of 74 ms between stimulus and R-wave appeared resulting in prolongation of V6 RWPT to 124 ms. Considering the immediate narrowing of QRS complexes following LBBP, the observed latency most probably reflects prolonged conduction time through the His-Purkinje system.


Assuntos
Bloqueio de Ramo , Eletrocardiografia , Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Masculino , Terapia de Ressincronização Cardíaca/métodos , Fascículo Atrioventricular/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Resultado do Tratamento , Idoso , Pessoa de Meia-Idade
11.
Card Electrophysiol Clin ; 16(2): 163-168, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749636

RESUMO

A 69-year-old woman with a history of heart failure with reduced ejection fraction presented for device interrogation of her cardiac implantable electronic device (CIED), revealing lead and pulse generator displacement. Surprisingly, she exhibited a narrow QRS on the ECG despite an underlying right bundle branch block, suggesting unintentional conduction system pacing (CSP). Traditional cardiac resynchronization therapy has been widely used for patients with heart failure, but alternatives like CSP are emerging as viable options. Given the global rise in CIED utilization, regular follow-up, device troubleshooting, and embracing remote monitoring are essential to manage and optimize patient outcomes.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Idoso , Feminino , Humanos , Bloqueio de Ramo/terapia , Bloqueio de Ramo/fisiopatologia , Eletrocardiografia , Falha de Equipamento , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia
12.
Biomed Eng Online ; 23(1): 46, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38741182

RESUMO

BACKGROUND: Integration of a patient's non-invasive imaging data in a digital twin (DT) of the heart can provide valuable insight into the myocardial disease substrates underlying left ventricular (LV) mechanical discoordination. However, when generating a DT, model parameters should be identifiable to obtain robust parameter estimations. In this study, we used the CircAdapt model of the human heart and circulation to find a subset of parameters which were identifiable from LV cavity volume and regional strain measurements of patients with different substrates of left bundle branch block (LBBB) and myocardial infarction (MI). To this end, we included seven patients with heart failure with reduced ejection fraction (HFrEF) and LBBB (study ID: 2018-0863, registration date: 2019-10-07), of which four were non-ischemic (LBBB-only) and three had previous MI (LBBB-MI), and six narrow QRS patients with MI (MI-only) (study ID: NL45241.041.13, registration date: 2013-11-12). Morris screening method (MSM) was applied first to find parameters which were important for LV volume, regional strain, and strain rate indices. Second, this parameter subset was iteratively reduced based on parameter identifiability and reproducibility. Parameter identifiability was based on the diaphony calculated from quasi-Monte Carlo simulations and reproducibility was based on the intraclass correlation coefficient ( ICC ) obtained from repeated parameter estimation using dynamic multi-swarm particle swarm optimization. Goodness-of-fit was defined as the mean squared error ( χ 2 ) of LV myocardial strain, strain rate, and cavity volume. RESULTS: A subset of 270 parameters remained after MSM which produced high-quality DTs of all patients ( χ 2 < 1.6), but minimum parameter reproducibility was poor ( ICC min = 0.01). Iterative reduction yielded a reproducible ( ICC min = 0.83) subset of 75 parameters, including cardiac output, global LV activation duration, regional mechanical activation delay, and regional LV myocardial constitutive properties. This reduced subset produced patient-resembling DTs ( χ 2 < 2.2), while septal-to-lateral wall workload imbalance was higher for the LBBB-only DTs than for the MI-only DTs (p < 0.05). CONCLUSIONS: By applying sensitivity and identifiability analysis, we successfully determined a parameter subset of the CircAdapt model which can be used to generate imaging-based DTs of patients with LV mechanical discoordination. Parameters were reproducibly estimated using particle swarm optimization, and derived LV myocardial work distribution was representative for the patient's underlying disease substrate. This DT technology enables patient-specific substrate characterization and can potentially be used to support clinical decision making.


Assuntos
Ventrículos do Coração , Processamento de Imagem Assistida por Computador , Humanos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Processamento de Imagem Assistida por Computador/métodos , Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/fisiopatologia , Fenômenos Biomecânicos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Fenômenos Mecânicos , Masculino , Feminino , Pessoa de Meia-Idade , Modelos Cardiovasculares
13.
Rev. Soc. Cardiol. Estado São Paulo, Supl. ; 34(2B): 144-144, abr-jun. 2024. ilus
Artigo em Português | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1561733

RESUMO

INTRODUÇÃO: O bloqueio de ramo mascarado é caracterizado no eletrocardiograma por um bloqueio de ramo direito (BRD) evidente no plano horizontal, associado ao bloqueio divisional anterossuperior (BDAS) e ondas S mínimas ou ausentes na derivação DI, o que dá ao plano frontal um padrão semelhante ao bloqueio de ramo esquerdo (BRE) com eixo de QRS desviado para esquerda. Por outro lado, o eletrocardiograma no bloqueio focal ou periférico do ventrículo esquerdo (VE) evidencia um QRS com retardo final e duração ≥ 120 ms, porém sem critérios de BRE ou BRD. RELATO DE CASO: Paciente masculino, 76 anos, com histórico de hipertensão, diabetes mellitus do tipo 2, dislipidemia, ex-tabagista, portador de insuficiência cardíaca com fração de ejeção reduzida realizou cateterismo cardíaco em dezembro de 2023, por doença arterial coronariana (DAC) estável, relevando: oclusão no terço médio da coronária direita, recebendo circulação colateral, 2º ramo diagonal com lesão de 80% no terço proximal e 1º ramo marginal com lesão de 70% no óstio de seu sub-ramo inferior, além de diversas lesões <50%. Devido a doença difusa e vasos de fino calibre foi optado por otimização do tratamento clínico. Paciente interna após 2 meses por dor torácica sendo solicitado cintilografia miocárdica com prova farmacológica (dipiridamol). O paciente apresentava o seguinte eletrocardiograma em repouso: Ritmo sinusal, bloqueio focal do VE + BDAS, presença de onda R alta em V2 - sugestivo de área inativa lateral. (Figura 1) Durante infusão de dipiridamol, paciente apresentou alteração do eletrocardiograma evoluindo para padrão de bloqueio de ramo mascado. (figura 2) E retornando ao seu eletrocardiograma de base após o término da infusão. A cintilografia evidenciou queda da fração de ejeção de 27% basal para 21% no estresse, ausência de sinais de isquemia do miocárdio e hipocaptação persiste de grande extensão nas paredes inferior, inferosseptal e inferolateral do ventrículo esquerdo. CONCLUSÃO: O bloqueio focal do VE e o bloqueio mascarado estão relacionados a fibrose ou disfunção miocárdica. A presença desses bloqueios se traduz em prognóstico desfavorável, estando associada a um maior risco de morte por doença cardiovascular e a um aumento substancial do risco de arritmias. Nesse caso podemos caracterizar um paciente com DAC estabelecida e grande área de fibrose, e a alteração no eletrocardiograma encontrada reforça a gravidade do quadro e implica pior prognóstico clínico.


Assuntos
Bloqueio de Ramo , Cintilografia , Obstrução da Via de Saída Ventricular Esquerda
14.
J Electrocardiol ; 84: 88-90, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38574635

RESUMO

Electrocardiogram of a patient affected by hypertrophic cardiomyopathy showed normal PR and QRS intervals and signs of left ventricular hypertrophy. In leads I,V5 and V6 the initial q waves were absent. A subsequent electrocardiogram revealed the appearance of prominent anterior QRS forces expressed by a change from rS to R pattern in leads V2 and V3 with a tall R wave in V2. PR and QRS intervals and QRS axis remained substantially unchanged. Other electrocardiograms showed day-to-day variations of the anterior displacement of QRS complex. The different degrees of anterior displacement appear to be an expression of an underlying left septal fascicular block, but a diagnosis cannot be made with certainty.


Assuntos
Eletrocardiografia , Humanos , Masculino , Cardiomiopatia Hipertrófica/fisiopatologia , Cardiomiopatia Hipertrófica/diagnóstico , Diagnóstico Diferencial , Pessoa de Meia-Idade , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/diagnóstico
17.
J Am Heart Assoc ; 13(9): e032777, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38639357

RESUMO

BACKGROUND: A delayed and recurrent complete atrioventricular block (CAVB) is a life-threatening complication of transcatheter aortic valve replacement (TAVR). Post-TAVR evaluation may be important in predicting delayed and recurrent CAVB requiring permanent pacemaker implantation (PPI). The impact of new-onset right bundle-branch block (RBBB) after TAVR on PPI remains unknown. METHODS AND RESULTS: In total, 407 patients with aortic stenosis who underwent TAVR were included in this analysis. Intraprocedural CAVB was defined as CAVB that occurred during TAVR. A 12-lead ECG was evaluated at baseline, immediately after TAVR, on postoperative days 1 and 5, and according to the need to identify new-onset bundle-branch block (BBB) and CAVB after TAVR. Forty patients (9.8%) required PPI, 17 patients (4.2%) had persistent intraprocedural CAVB, and 23 (5.7%) had delayed or recurrent CAVB after TAVR. The rates of no new-onset BBB, new-onset left BBB, and new-onset RBBB were 65.1%, 26.8%, and 4.7%, respectively. Compared with patients without new-onset BBB and those with new-onset left BBB, the rate of PPI was higher in patients with new-onset RBBB (3.4% versus 5.6% versus 44.4%, P<0.0001). On post-TAVR evaluation in patients without persistent intraprocedural CAVB, the multivariate logistic regression analysis showed that new-onset RBBB was a statistically significant predictor of PPI compared with no new-onset BBB (odds ratio [OR], 18.0 [95% CI, 5.94-54.4]) in addition to the use of a self-expanding valve (OR, 2.97 [95% CI, 1.09-8.10]). CONCLUSIONS: Patients with new-onset RBBB after TAVR are at high risk for PPI.


Assuntos
Estenose da Valva Aórtica , Bloqueio de Ramo , Estimulação Cardíaca Artificial , Eletrocardiografia , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/diagnóstico , Estenose da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Idoso , Estimulação Cardíaca Artificial/efeitos adversos , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/fisiopatologia , Fatores de Risco , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Tempo , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Complicações Pós-Operatórias/diagnóstico , Recidiva
18.
Pacing Clin Electrophysiol ; 47(6): 771-775, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38576198

RESUMO

BACKGROUND: His bundle pacing (HBP) engaged electrical activation of both ventricles by stimulating the His-Purkinje network, which could avoid marked ventricles dyssynchrony. The lead was given three to five clockwise rotations at the site with the His potential to anchor the interventricular septum. In 2018, the Multicenter His Bundle Pacing Collaborative Working Group recommended that the His bundle capture threshold should be lower than 2.5 V/1 ms in non-pacing-dependent patients, and pacing-dependent patients should have a lower adjacent ventricular capture threshold as self-backup. Therefore, to avoid safety issues such as loss of capture caused by increased threshold, we believe that more stringent criteria should be adopted in patients with atrioventricular block (AVB). In previous studies, the connection cable needed to be disconnected during the screwing. When the procedure was finished, the performer found that the patients with His bundle injury could obtain a lower threshold than those without His bundle injury. Although no studies of new bundle branch block (BBB) or AVB by the acute His bundle injury was reported. However, It is worrying that the damage of His bundle seems random during the procedure. How to balance avoiding severe injury with a lower capture threshold? At present, we report a case of light His injury and lower His capture threshold under continuous intracardiac electrocardiogram monitoring.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Eletrocardiografia , Fascículo Atrioventricular/fisiopatologia , Humanos , Estimulação Cardíaca Artificial/métodos , Masculino , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/fisiopatologia , Idoso , Bloqueio de Ramo/terapia , Bloqueio de Ramo/fisiopatologia
19.
Pacing Clin Electrophysiol ; 47(6): 776-779, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38583090

RESUMO

BACKGROUND: Left bundle branch block (LBBB) induced cardiomyopathy is an increasingly recognized disease entity.  However, no clinical testing has been shown to be able to predict such an occurrence. CASE REPORT: A 70-year-old male with a prior history of LBBB with preserved ejection fraction (EF) and no other known cardiovascular conditions presented with presyncope, high-grade AV block, and heart failure with reduced EF (36%). His coronary angiogram was negative for any obstructive disease. No other known etiologies for cardiomyopathy were identified. Artificial intelligence-enabled ECGs performed 6 years prior to clinical presentation consistently predicted a high probability (up to 91%) of low EF. The patient successfully underwent left bundle branch area (LBBA) pacing with correction of the underlying LBBB. Subsequent AI ECGs showed a large drop in the probability of low EF immediately after LBBA pacing to 47% and then to 3% 2 months post procedure. His heart failure symptoms markedly improved and EF normalized to 54% at the same time. CONCLUSIONS: Artificial intelligence-enabled ECGS may help identify patients who are at risk of developing LBBB-induced cardiomyopathy and predict the response to LBBA pacing.


Assuntos
Inteligência Artificial , Bloqueio de Ramo , Cardiomiopatias , Eletrocardiografia , Humanos , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Masculino , Idoso , Cardiomiopatias/fisiopatologia , Cardiomiopatias/etiologia , Cardiomiopatias/terapia , Valor Preditivo dos Testes
20.
Eur Heart J Cardiovasc Imaging ; 25(7): 879-887, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38565632

RESUMO

Traditional right ventricular pacing (RVP) has been linked to the deterioration of both left ventricular diastolic and systolic function. This worsening often culminates in elevated rates of hospitalization due to heart failure, an increased risk of atrial fibrillation, and increased morbidity. While biventricular pacing (BVP) has demonstrated clinical and echocardiographic improvements in patients afflicted with heart failure and left bundle branch block, it has also encountered significant challenges such as a notable portion of non-responders and procedural failures attributed to anatomical complexities. In recent times, the interest has shifted towards conduction system pacing, initially, His bundle pacing, and more recently, left bundle branch area pacing, which are seen as promising alternatives to established methods. In contrast to other approaches, conduction system pacing offers the advantage of fostering more physiological and harmonized ventricular activation by directly stimulating the His-Purkinje network. This direct pacing results in a more synchronized systolic and diastolic function of the left ventricle compared with RVP and BVP. Of particular note is the capacity of conduction system pacing to yield a shorter QRS, conserve left ventricular ejection fraction, and reduce rates of mitral and tricuspid regurgitation when compared with RVP. The efficacy of conduction system pacing has also been found to have better clinical and echocardiographic improvement than BVP in patients requiring cardiac resynchronization. This review will delve into myocardial function in conduction system pacing compared with that in RVP and BVP.


Assuntos
Estimulação Cardíaca Artificial , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Feminino , Masculino , Sistema de Condução Cardíaco/fisiopatologia , Bloqueio de Ramo/terapia , Bloqueio de Ramo/fisiopatologia , Ecocardiografia , Resultado do Tratamento , Fascículo Atrioventricular/fisiopatologia , Idoso , Volume Sistólico/fisiologia , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...