Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.389
Filtrar
1.
J. optom. (Internet) ; 17(3): [100497], jul.-sept2024. graf, tab
Artigo em Inglês | IBECS | ID: ibc-231871

RESUMO

Purpose: To compare the eye defocus curves (DCs) obtained with stimuli on red, green, and white backgrounds and to investigate the applicability of the duochrome test (DT) in different age groups. Methods: 12 elderly (ELD: 59.3 ± 3.9 years) and 8 young (YG: 22.1 ± 1.1 years) subjects were recruited. An optometric assessment with the DT was carried out to obtain the subjective refraction at distance. DCs at distance on green, white, and red backgrounds were measured and the following parameters were deduced: dioptric difference between red-green, green-white, red-white focal positions (minima of the DCs), best corrected visual acuity (BCVA), and widths of the DCs for red, green, and white. Results: The DC difference between the green-white focal positions (mean ± standard deviation) was -0.12±0.17 diopters (D) (ELD, p = 0.012) and -0.11±0.12 D (YG, p = 0.039), while the red-white difference was not statistically significant. The DC red-green difference was 0.20±0.16 D (ELD, p = 0.002) and 0.18±0.18 D (YG, p = 0.008). The ELD BCVA with green background was significantly worse than BCVA with red (p = 0.007) and white (p = 0.007). The mean value of the DC's width in ELD for green (1.01±0.36 D) was higher than for red (0.77±0.21 D) and for white (0.84±0.35 D), but with no statistical significance. Conclusion: Both age groups showed a slight focusing preference for red when using white light. Moreover, ELD showed a worse BCVA with a green compared to a red background. Despite these results deduced by DC analyses, these aspects do not compromise the possibility of using the DT in clinical practice both in the young and in the elderly. Furthermore, the difference of about 0.20 D between red-green DC in both groups confirms the clinical appropriateness of the widespread use of 0.25 D step as the standard minimum difference in power between correcting lenses.(AU)


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Idoso , Visão Ocular , Acuidade Visual , Fundo de Olho , Lentes de Contato , Testes Visuais
2.
J. optom. (Internet) ; 17(3): [100514], jul.-sept2024. tab
Artigo em Inglês | IBECS | ID: ibc-231876

RESUMO

Purpose: To analyze binocular vision of individuals aged 18 to 35 years diagnosed with keratoconus, utilizing spectacles and rigid gas-permeable (RGP) contact lenses. Research was led by the Universidad Autónoma de Aguascalientes, México and Fundación Universitaria del Área Andina Pereira, Colombia. Methods: A single center, prospective non-randomized, comparative, interventional, open-label study, in which the differences in binocular vision performance with both spectacles and RGP contact lenses was carried out from December 2018 to December 2019. Sampling was performed according to consecutive cases with keratoconus that met the inclusion criteria until the proposed sample size was reached. Results: Rigid gas-permeable (RGP) contact lenses notably enhanced distance and near visual acuity in keratoconus patients compared to spectacles. Visual alignment analysis shows exophoria at both distances and is slightly higher with RGP contact lenses. The difference was statistically significant (p<0.05), with 82.5 % presenting compensated phoria with spectacles and pnly 42.50% with RGP contact lenses. Stereoscopic vision improved while wearing RGP contact lenses (42.59 %), although accommodation and accommodative flexibility remained within normal ranges. Conclusions: Patients with keratoconus fitted with RGP contact lenses have improved binocular vision skills such as visual acuity, stereopsis, and accommodative flexibility. However, even when the vergence and motor system is decompensated with respect to normal ranges, the range between break and recovery points for both fusional reserves and the near point of convergence (NPC) improves with the use of RGP contact lenses, giving indications of an adaptive condition of the motor system from the medium to the long term.(AU)


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto Jovem , Ceratocone , Óculos , Lentes de Contato , Visão Binocular , Testes Visuais , Colômbia , México , Oftalmologia , Estudos Prospectivos
3.
J. optom. (Internet) ; 17(2): [100498], Abr-Jun, 2024. tab, graf
Artigo em Inglês | IBECS | ID: ibc-231627

RESUMO

Objective: The high incidence of keratoconus has caused its management, etiology, and pathogenesis to be controversial topics in the ophthalmology field. This study aims to analyze the relationship between the different publications and authors through citation networks, as well as to identify the research areas and determine the most cited article. Methods: The search for publications was carried out through the Web of Science database, using the term “Keratoconus” between 1900 and December 2022. The Citation Network Explorer and CiteSpace software were used for the publication analysis. Results: 9,655 publications were found, with 124,379 citations generated on the network. The year with the highest number of publications was 2021. The most cited publication was “Keratoconus” by Rabinowitz, published in 1998. Cluster function gave five groups of research areas about keratoconus: corneal signs and parameters, cross-linking efficiency and effects, clinical factors, keratoplasty, and treatment. Conclusions: The citation network offers an objective and comprehensive analysis of the papers on keratoconus. (AU)


Assuntos
Transplante de Córnea , Ceratocone , Oftalmologia , Lentes de Contato
4.
Invest Ophthalmol Vis Sci ; 65(5): 4, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38691089

RESUMO

Purpose: To investigate the adhesion of Acanthamoeba to scleral contact lens (ScCL) surface according to lens shape. Methods: Two strains of A. polyphaga (CDC:V062 and ATCC 30461) and one clinical Acanthamoeba isolate, were inoculated onto five contact lens (CL): one first-generation silicone hydrogel (SHCL; lotrafilcon B; adhesion control) containing plasma surface treatment; two ScCL (fluorosilicone acrylate) one containing surface treatment composed of plasma and the other containing plasma with Hydra-PEG, and two CL designed with a flat shape having the same material and surface treatments of the ScCL. Trophozoites that adhered to the lens's surfaces were counted by inverted optical light microscopy. Possible alterations of the lens surface that could predispose amoeba adhesion and Acanthamoeba attached to these lens surfaces were evaluated by scanning electron microscopy (SEM). Results: All strains revealed greater adhesion to the ScCL when compared with the flat lenses (P < 0.001). The clinical isolate and the ATCC 30461 had a higher adhesion (P < 0.001) when compared with the CDC:V062. A rough texture was observed on the surface of the lenses that have been examined by SEM. Also, SEM revealed that the isolates had a rounded appearance on the surface of the ScCL in contrast with an elongated appearance on the surface of the silicone hydrogel. Conclusions: The findings revealed that the curved shape of the ScCL favors amoeba adhesion.


Assuntos
Acanthamoeba , Microscopia Eletrônica de Varredura , Acanthamoeba/fisiologia , Acanthamoeba/ultraestrutura , Esclera , Humanos , Lentes de Contato Hidrofílicas/parasitologia , Adesão Celular/fisiologia , Lentes de Contato/parasitologia , Trofozoítos/ultraestrutura , Trofozoítos/fisiologia , Hidrogéis , Animais
5.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38742501

RESUMO

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Assuntos
Lentes de Contato , Ceratocone , Esclera , Acuidade Visual , Humanos , Ceratocone/cirurgia , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Ceratocone/terapia , Feminino , Masculino , Adulto , Esclera/cirurgia , Implantação de Prótese/métodos , Implantação de Prótese/instrumentação , Resultado do Tratamento , Topografia da Córnea , Próteses e Implantes , Adulto Jovem , Ajuste de Prótese/métodos , Adolescente , Substância Própria/cirurgia
7.
Sci Rep ; 14(1): 11727, 2024 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-38778161

RESUMO

The tear fluid is a readily accessible, potential source for biomarkers of disease and could be used to monitor the ocular response to contact lens (CL) wear or ophthalmic pathologies treated by therapeutic CLs. However, the tear fluid remains largely unexplored as a biomarker source for RNA-based molecular analyses. Using a rabbit model, this study sought to determine whether RNA could be collected from commercial CLs and whether the duration of CL wear would impact RNA recovery. The results were referenced to standardized strips of filtered paper (e.g., Shirmer Strips) placed in the inferior fornix. By performing total RNA isolation, precipitation, and amplification with commercial kits and RT-PCR methods, CLs were found to have no significant differences in RNA concentration and purity compared to Schirmer Strips. The study also identified genes that could be used to normalize RNA levels between tear samples. Of the potential control genes or housekeeping genes, GAPDH was the most stable. This study, which to our knowledge has never been done before, provides a methodology for the detection of RNA and gene expression changes from tear fluid that could be used to monitor or study eye diseases.


Assuntos
Lentes de Contato , RNA , Lágrimas , Lágrimas/metabolismo , Animais , Coelhos , RNA/isolamento & purificação , RNA/genética , RNA/análise
8.
Transl Vis Sci Technol ; 13(5): 12, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38758570

RESUMO

Purpose: To evaluate the visual performance in adolescents undergoing orthokeratology (OrthoK) treatment with two different optical zone diameters (OZDs). Methods: This randomized, double-masked, self-controlled prospective study was conducted at Tianjin Eye Hospital (Tianjin, China) in June 2022. Thirty-six eligible schoolchildren were enrolled and fitted with corneal refractive therapy lenses with two sizes of OZDs (5 mm [5OZ] and 6 mm [6OZ]). Each participant was randomized to wear the 5OZ in one eye and the 6OZ in the contralateral eye. Subjective visual quality was assessed using visual acuity, refraction, contrast sensitivity function, and visual symptoms, and the objective optical quality was assessed using ocular higher order aberrations (HOAs) and modulation transfer function (MTF). Results: Thirty-five myopic children completed a 1-month follow-up visit. The 5OZ lens induced significantly smaller treatment zone diameters than the 6OZ lens (P < 0.001). Subjective visual quality did not differ significantly between the two groups. Compared to baseline, aberrations of Z40, coma-like, spherical-like, and total HOAs in both groups increased significantly (P < 0.05). For the 3-mm pupils, spherical aberration in the 5OZ group was significantly higher than that in the 6OZ group (P < 0.05). The MTF value of the 6OZ group was significantly higher than that of 5OZ group for 0.3 and 1.5 cycles per degree for the 3-mm pupils (P = 0.006 and P = 0.026, respectively). However, HOAs or MTF did not differ significantly between the two groups for the 5-mm pupils. Conclusions: The difference induced by varying OZD was significant only in the smaller pupil condition. The selection of OZD in OrthoK designs in real-world patient management should be done while considering individual pupil size. Translational Relevance: This study revealed that the objective visual quality of small OZD lenses was only slightly affected for the small pupil size.


Assuntos
Miopia , Procedimentos Ortoceratológicos , Refração Ocular , Acuidade Visual , Humanos , Feminino , Procedimentos Ortoceratológicos/métodos , Masculino , Acuidade Visual/fisiologia , Estudos Prospectivos , Adolescente , Miopia/terapia , Miopia/fisiopatologia , Criança , Método Duplo-Cego , Refração Ocular/fisiologia , Sensibilidades de Contraste , Lentes de Contato
9.
Int J Med Sci ; 21(7): 1329-1336, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38818477

RESUMO

Purpose: The purpose of this study was to compare the differences in myopic control effects between orthokeratology (OK) contact lenses and defocus incorporated multiple segments (DIMS) spectacle lenses. Methods: A retrospective cohort study was conducted that included patients who had received OK lens, DIMS spectacle lens or single-vision spectacle treatments. A total of 54 eyes from 27 individuals, 38 eyes from 19 individuals and 42 eyes from 21 individuals were enrolled into the OK lens, DIMS and control groups, respectively. The primary outcomes were the changes in the spherical equivalent refraction (SER) and axial length (AXL) among the groups. A repeated-measure ANCOVA was adopted to calculate the SER progression and AXL elongation of the OK lens group compared with the DIMS group. Results: The difference in the SER progression was clinically non-significant in the OK lens group compared with the DIMS and control groups (P = 0.001). The total AXL elongation results were similar between the OK lens and DIMS groups, but these were lower than in the control group (P = 0.005). The repeated-measure ANCOVA revealed that the SER progression difference during the study interval was clinically non-significant in the OK lens group when compared with the DIMS group (P = 0.028). The AXL elongation results between the OK lens and DIMS populations did not illustrate a significant difference (P = 0.607). In a subgroup analysis of moderate astigmatism, better AXL control was observed in the DIMS subgroup compared with the OK lens subgroup (P = 0.016). Conclusions: The OK lens demonstrated a clinically non-significant effect on the SER and AXL controls compared with the DIMS spectacle lens.


Assuntos
Óculos , Miopia , Procedimentos Ortoceratológicos , Refração Ocular , Humanos , Miopia/terapia , Miopia/fisiopatologia , Masculino , Feminino , Procedimentos Ortoceratológicos/métodos , Estudos Retrospectivos , Refração Ocular/fisiologia , Adulto , Lentes de Contato , Adulto Jovem , Adolescente , Acuidade Visual , Resultado do Tratamento
10.
Harefuah ; 163(5): 278-285, 2024 May.
Artigo em Hebraico | MEDLINE | ID: mdl-38734939

RESUMO

INTRODUCTION: The importance of myopia management lies in the desire to minimize the potential ocular risks that increase with high myopia. AIMS: To assess the decrease in myopia progression using topical low dose atropine combined with peripheral blur contact lenses (CL). METHODS: This retrospective review study included 25 children between the ages of 8.5 years to 14 years. The children all had a minimal increase in myopia of 0.75D during the year prior to treatment. The children were divided into two groups. The control group included 14 children who wore single-vision spectacles )SV) averaging 3.20±0.9D ranging from 1.5-5.3D. The study group included 11 children who wore dual-focus CL, with an average prescription of 3.4±0.7D ranging from 2.5 to 4.3D, for one year. At that point, when an additional myopia increase was observed, the children were additionally treated with topical 0.01% atropine for two years (CL+A0.01). RESULTS: There was an increase in myopia in the SV group of 1.12±0.52D, 1.08±0.56D and 0.96±0.53D in the first, second, and third years, respectively. The myopia increase in the CL+A0.01 group was 0.57±0.48D, 0.14±0.34D, and 0.17±0.29D in the first, second, and third years, respectively. CONCLUSIONS: Low-dose atropine combined with peripheral blur contact lenses was effective in decreasing myopia progression in this study. Additional, larger-scale studies are required in the future. DISCUSSION: This study found a significant decrease in myopia progression in the second and third years of treatment. The CL group showed less effectivity than the CL+A0.01 group.


Assuntos
Atropina , Lentes de Contato , Progressão da Doença , Miopia , Humanos , Atropina/administração & dosagem , Criança , Miopia/terapia , Miopia/fisiopatologia , Estudos Retrospectivos , Adolescente , Masculino , Feminino , Resultado do Tratamento , Midriáticos/administração & dosagem , Soluções Oftálmicas/administração & dosagem , Óculos
11.
Zhonghua Yan Ke Za Zhi ; 60(4): 330-336, 2024 Apr 11.
Artigo em Chinês | MEDLINE | ID: mdl-38583056

RESUMO

Objective: To investigate the influence of corneal e-value on the effectiveness of orthokeratology in controlling myopia in children and adolescents. Methods: A retrospective cohort study was conducted, involving the data from 1 563 myopic patients (1 563 eyes) who underwent orthokeratology at the Affiliated Eye Hospital of Shandong University of Traditional Chinese Medicine from June 2015 to August 2021 and adhered to lens wear for at least 2 years. The cohort consisted of 737 males and 826 females with an average age of (10.84±2.13) years. Based on corneal e-value parameters obtained from corneal topography, patients were categorized into a low e-value group (n=425) and a high e-value group (n=1 138). Data on gender, age, parental myopia history, and baseline measures such as spherical equivalent (SE), axial length, and corneal e-value were collected. Differences in axial length change and corneal fluorescein staining rates were compared between the two groups at 1 and 2 years after the start of lens wear. A generalized linear mixed model was established with axial length change as the dependent variable to analyze the correlation between axial length change and baseline corneal e-value. Results: The initial age of the 1 563 myopic patients was (10.84±2.13) years, with a baseline SE of (-3.05±1.30) D. After 1 year of lens wear, the axial length change was (0.20±0.19) mm in the low e-value group and (0.24±0.20) mm in the high e-value group. After 2 years, the changes were (0.38±0.25) mm and (0.43±0.27) mm, respectively, with statistically significant differences (all P<0.05). The incidence of corneal staining after 1 year of lens wear was 9.2% (39/425) in the low e-value group and 14.1% (160/1 138) in the high e-value group. After 2 years, the rates were 15.8% (67/425) and 21.8% (248/1 138), respectively, with statistically significant differences (all P<0.05). After adjusting for parental myopia history, age, SE, and baseline axial length, the baseline corneal e-value was positively correlated with axial length change at 1 and 2 years after lens wear (all P<0.05). Conclusions: Corneal e-value is an independent factor influencing the effectiveness of orthokeratology in controlling myopia. A smaller corneal e-value is associated with slower axial length growth after orthokeratology, indicating better control of myopia in treated eyes.


Assuntos
Lentes de Contato , Miopia , Procedimentos Ortoceratológicos , Masculino , Feminino , Criança , Humanos , Adolescente , Estudos Retrospectivos , Comprimento Axial do Olho , Miopia/terapia , Topografia da Córnea , Refração Ocular
12.
Turk J Ophthalmol ; 54(2): 90-102, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38645732

RESUMO

Congenital cataract is among the main causes of treatable vision loss in childhood. The first weeks and months of life are a critical time for the development of vision. Therefore, early cataract surgery and effective multifaceted treatment of the resulting aphakia in the early stages of life are of great value for the management of vision development. Among the treatment models, contact lenses (CL) have an important place in infancy and early childhood up to the age of 2 years. Although good visual gains were not considered very likely, especially in unilateral aphakia, important steps have been taken in the treatment of pediatric aphakia thanks to the surgical techniques developed over time and the increasing experience with optical correction systems, especially CLs. This review examines current developments in the types of CL used in pediatric aphakia, their application features, comparison with other optical systems, the features of amblyopia treatment in the presence of CL, and the results obtained with family compliance to CL wear and occlusion therapy in the light of existing studies.


Assuntos
Afacia Pós-Catarata , Lentes de Contato , Acuidade Visual , Humanos , Afacia Pós-Catarata/terapia , Afacia Pós-Catarata/fisiopatologia , Acuidade Visual/fisiologia , Lactente , Pré-Escolar , Catarata/congênito , Extração de Catarata/métodos , Ambliopia/terapia , Ambliopia/fisiopatologia , Afacia , Criança , Recém-Nascido
13.
Sci Rep ; 14(1): 8878, 2024 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632261

RESUMO

This prospective single-arm study aimed to evaluate the clinical efficacy and safety of a refractive multifocal contact lens for the correction of presbyopia in 22 patients. The participants underwent clinical examinations before and 1 week after wearing a refractive multifocal contact lens (OptaCon ZOOM). The primary endpoints were the corrected distance visual acuity (CDVA) and distance-corrected near visual acuity (DCNVA). Defocus curve, contrast sensitivity, and ocular surface disease index (OSDI) were analyzed. A slit-lamp examination was performed for safety analysis. Contact lens comfort and patient satisfaction were assessed using a questionnaire. No significant difference in CDVA was observed before and 1 week after refractive multifocal contact lens use (p = 0.127), whereas DCNVA was significantly improved after 1 week (p < 0.001). The contrast sensitivity was not significantly affected at any spatial frequency under mesopic or photopic conditions. OSDI was significantly increased (p = 0.023). The patient-reported satisfaction scores were 96.2, 91.9, and 85.0 out of 100 at far, intermediate, and near distances, respectively. No significant adverse events were observed. Refractive multifocal contact lenses improved near vision while maintaining distance vision in presbyopic patients, without compromising contrast sensitivity. The study results suggest that OptaCon ZOOM can be considered safe and effective for the correction of presbyopia.


Assuntos
Lentes de Contato , Presbiopia , Humanos , Estudos Prospectivos , Refração Ocular , Acuidade Visual
14.
Sci Adv ; 10(15): eadl3262, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38598619

RESUMO

Contact lenses (CLs) are prone to adhesion and invasion by pollutants and pathogenic bacteria, leading to infection and inflammatory diseases. However, the functionalization of CL (biological functions such as anti-fouling, antibacterial, and anti-inflammatory) and maintaining its transparency still face great challenges. In this work, as a member of the MXenes family, vanadium carbide (V2C) is modified onto CL via a water transfer printing method after the formation of a tightly arranged uniform film at the water surface under the action of the Marangoni effect. The coating interface is stable owing to the electrostatic forces. The V2C-modified CL (V2C@CL) maintains optical clarity while providing good biocompatibility, strong antioxidant properties, and anti-inflammatory activities. In vitro antibacterial experiments indicate that V2C@CL shows excellent performance in bacterial anti-adhesion, sterilization, and anti-biofilm formation. Last, V2C@CL displays notable advantages of bacteria elimination and inflammation removal in infectious keratitis treatment.


Assuntos
Infecções Bacterianas , Lentes de Contato , Humanos , Antibacterianos/farmacologia , Anti-Inflamatórios , Bactérias , Lentes de Contato/microbiologia , Inflamação , Nitritos , Elementos de Transição , Água , Impressão
15.
Zhonghua Yan Ke Za Zhi ; 60(4): 343-351, 2024 Apr 11.
Artigo em Chinês | MEDLINE | ID: mdl-38583058

RESUMO

Objective: The aim of this paper is to compare the refractive correction effects of rigid gas permeable contact lenses (RGPCL) and spectacle correction in children with aphakia after congenital cataract surgery. Methods: This was a prospective non-randomized controlled trial. Children with aphakic eyes after congenital cataract surgery, who underwent vision correction in the Strabismus and Pediatric Ophthalmology Clinic of Beijing Tongren Hospital affiliated with Capital Medical University from April 2012 to November 2019, were continuously collected. Those who voluntarily chose to wear RGPCL for refractive correction were included in the experimental group. Patients with monocular disease were in trial group 1, and patients with binocular disease were in trial group 2. Patients who chose to wear frame glasses for refractive correction were included in the control group. Patients with monocular disease were in control group 1, and patients with binocular disease were in control group 2. Regional origin, medical history, and family information were collected at the first diagnosis. During the follow-up, adverse reactions occurring during the process of wearing glasses were recorded. The Teller acuity card was used for visual examination to obtain the best-corrected visual acuity and convert it into the logarithm of the minimum resolution angle. The degree of nystagmus was determined according to the amplitude and frequency of nystagmus. Treatment cost, treatment compliance, and the reasons for adopting or not adopting RGPCL were analyzed through a questionnaire completed by the parents of children with RGPCL. Results: A total of 203 children (344 eyes) who underwent congenital cataract surgery were included, including 124 males (210 eyes) and 79 females (134 eyes). The age range was 3 to 36 months. There were 28 cases in the experimental group, including 19 cases in trial group 1 and 9 cases in trial group 2. There were 175 cases in the control group, including 43 cases in control group 1 and 132 cases in control group 2. Except for 6 months of age, the visual acuity of the experimental group was better than that of the control group, and the differences were statistically significant (P<0.05). The visual acuity of children in trial group 1 was better than that of children in control group 1 at the same age. Among them, at 12 months of age [1.54 (1.27, 1.97), 1.84 (0.97, 2.12)], 18 months of age [1.27 (0.97, 1.84), 1.84 (0.97, 2.12)], 24 months of age [1.54 (1.27, 1.84), 1.84 (0.97, 2.12)], and 30 months old [0.97 (0.66, 1.27), 1.54 (0.66, 2.12)], the difference was statistically significant (P<0.001). The visual acuity of children in trial group 2 was better than that in control group 2 at the same age. Among them, at 18 months old [1.27 (0.97, 1.54), 1.27 (0.66, 2.12)], 24 months old [0.97 (0.66, 1.27), 1.27 (0.66, 2.12)], and 30 months old [1.27 (0.66, 2.12)], the difference was statistically significant (P<0.05). The remission rate of nystagmus in the experimental group was 8/9 (8 cases), the remission rate of nystagmus in the control group was 34.40% (32 cases), and the exacerbation rate was 29.03% (27 cases). The average annual cost of the experimental group was 25 125 yuan, and that of the control group was 2 511 yuan. Conclusions: RGPCL is a well-tolerated, safe, and effective treatment for infants and young children. The visual acuity and degree of nystagmus were significantly improved in children who wore RGPCL for aphakia refractive correction after congenital cataract surgery compared with spectacle correction.


Assuntos
Afacia , Extração de Catarata , Catarata , Lentes de Contato , Nistagmo Patológico , Oftalmologia , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Catarata/terapia , Catarata/congênito , Óculos , Estudos Prospectivos
16.
Nat Commun ; 15(1): 3588, 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38678013

RESUMO

Eye tracking techniques enable high-efficient, natural, and effortless human-machine interaction by detecting users' eye movements and decoding their attention and intentions. Here, a miniature, imperceptible, and biocompatible smart contact lens is proposed for in situ eye tracking and wireless eye-machine interaction. Employing the frequency encoding strategy, the chip-free and battery-free lens successes in detecting eye movement and closure. Using a time-sequential eye tracking algorithm, the lens has a great angular accuracy of <0.5°, which is even less than the vision range of central fovea. Multiple eye-machine interaction applications, such as eye-drawing, Gluttonous Snake game, web interaction, pan-tilt-zoom camera control, and robot vehicle control, are demonstrated on the eye movement model and in vivo rabbit. Furthermore, comprehensive biocompatibility tests are implemented, demonstrating low cytotoxicity and low eye irritation. Thus, the contact lens is expected to enrich approaches of eye tracking techniques and promote the development of human-machine interaction technology.


Assuntos
Algoritmos , Lentes de Contato , Movimentos Oculares , Tecnologia de Rastreamento Ocular , Movimentos Oculares/fisiologia , Animais , Humanos , Coelhos , Sistemas Homem-Máquina
18.
Biomacromolecules ; 25(5): 2728-2739, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38563621

RESUMO

Myopia is a global public health issue. Rigid contact lenses (RCLs) are an effective way to correct or control myopia. However, bioadhesion issues remain one of the significant obstacles limiting its clinical application. Although enhancing hydrophilicity through various surface treatments can mitigate this problem, the duration of effectiveness is short-lived and the processing involved is complex and costly. Herein, an antiadhesive RCLs material was designed via 8-armed methacrylate-POSS (8MA-POSS), and poly(ethylene glycol) methacrylate (PEGMA) copolymerization with 3-[tris(trimethylsiloxy)silyl] propyl methacrylate (TRIS). The POSS and PEG segments incorporated P(TRIS-co-PEGMA-co-8MA-POSS) (PTPM) material was obtained and their optical transparency, refractive index, resolution, hardness, surface charge, thermal features, and wettability were tested and optimized. The antibioadhesion activities, including protein, lipid, and bacteria, were evaluated as well. In vitro and in vivo results indicated that the optimized antibioadhesive PTPM materials present good biocompatibility and biosafety. Thus, such POSS and PEG segments containing material were a potential antibioadhesive RCL material option.


Assuntos
Lentes de Contato , Metacrilatos , Compostos de Organossilício , Polietilenoglicóis , Polietilenoglicóis/química , Metacrilatos/química , Animais , Compostos de Organossilício/química , Compostos de Organossilício/farmacologia , Aderência Bacteriana/efeitos dos fármacos , Camundongos , Materiais Biocompatíveis/química , Humanos , Miopia/tratamento farmacológico
19.
In Vivo ; 38(3): 1229-1235, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38688617

RESUMO

BACKGROUND/AIM: Given the characteristics of Serratia marcescens (S. marcescens), this study aimed at investigating its presence in the hands and contact lens cases of orthokeratology wearers, along with the status of bacterial contamination. PATIENTS AND METHODS: The 39 patients received the questionnaires about the background of orthokeratology and hygiene habits. A total of 39 contact lens cases and 39 hand samples from the patients were collected at Show Chwan Memorial Hospital from June to August in 2020 and sent to National Chung Cheng University for DNA extraction and PCR identification. RESULTS: The results indicated a detection rate of 5.13% for S. marcescens in the contact lens cases and 12.82% in the hand samples. Additionally, 66.67% of contact lens case samples and 30.77% of hand samples found positive for 16s bacterial amplicons. The relationship between hand contamination and the duration of contact lens usage were revealed for both S. marcescens (p=0.021) and 16s bacterial amplicons (p=0.048). CONCLUSION: The results indicated that hand hygiene is more critical than focusing on contact lens hygiene when it comes to preventing S. marcescens infections. Nevertheless, both proper hand and contact lens hygiene practices can reduce the detection of bacterial eye pathogens, especially a common intestinal bacterium.


Assuntos
Infecções por Serratia , Serratia marcescens , Humanos , Serratia marcescens/isolamento & purificação , Serratia marcescens/genética , Masculino , Feminino , Infecções por Serratia/microbiologia , Infecções por Serratia/epidemiologia , Infecções por Serratia/diagnóstico , Procedimentos Ortoceratológicos/métodos , Lentes de Contato/microbiologia , Lentes de Contato/efeitos adversos , Criança , Adolescente , Higiene , Higiene das Mãos , Adulto , Mãos/microbiologia
20.
ACS Appl Mater Interfaces ; 16(17): 22522-22531, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38651323

RESUMO

Flexible bioelectronic devices that can perform real-time and accurate intraocular pressure (IOP) monitoring in both clinical and home settings hold significant implications for the diagnosis and treatment of glaucoma, yet they face challenges due to the open physiological environment of the ocular. Herein, we develop an intelligent wireless measuring contact lens (WMCL) incorporating a dual inductor-capacitor-resistor (LCR) resonant system to achieve temperature self-compensation for quantitative IOP monitoring in different application environments. The WMCL utilizes a compact circuitry design, which enables the integration of low-frequency and high-frequency resonators within a single layer of a sensing circuit without causing visual impairment. Mechanically guided microscale 3D encapsulation strategy combined with flexible circuit printing techniques achieves the surface-adaptive fabrication of the WMCL. The specific design of frequency separation imparts distinct temperature response characteristics to the dual resonators, and the linear combination of the dual resonators can eliminate the impact of temperature variations on measurement accuracy. The WMCL demonstrates outstanding sensitivity and linearity in monitoring the IOP of porcine eyes in vitro while maintaining satisfactory measurement accuracy even with internal temperature variations exceeding 10 °C. Overcoming the impact of temperature variations on IOP monitoring from the system level, the WMCL showcases immense potential as the next generation of all-weather IOP monitoring devices.


Assuntos
Lentes de Contato , Pressão Intraocular , Temperatura , Tecnologia sem Fio , Pressão Intraocular/fisiologia , Tecnologia sem Fio/instrumentação , Animais , Suínos , Desenho de Equipamento , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...