Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Coluna/Columna ; 12(3): 232-234, 2013. ilus
Article in Portuguese | LILACS | ID: lil-694043

ABSTRACT

OBJECTIVO: Avaliar a técnica free hand de colocação de parafusos transpediculares na coluna torácica, lombar e sagrada. MÉTODOS: Avaliação clínica e imagiológica (tomografia computorizada) de 25 pacientes (13 mulheres e 12 homens) submetidos a instrumentação vertebral num total de 124 parafusos transpediculares aplicados, utilizando a técnica free hand. Os parafusos foram inseridos de T11 a S1, e a maioria destes foram colocados nos níveis L4, L5 e S1. RESULTADOS: 94% dos parafusos transpediculares estavam correctamente colocados no pedículo. Verificou-se que 6% (7 parafusos) estavam mal colocados e destes apenas dois violavam a cortical inferomedial, um destes apresentava uma perfuração inferior a 2 mm e o outro entre 2 e 4 mm. Nenhum dos pacientes seguidos apresentou complicações associadas ao incorrecto posicionamento dos parafusos. CONCLUSÃO: A técnica free hand é segura na instrumentação da coluna torácica e lombo-sagrada.


OBJECTIVE: To evaluate the correct placement of transpedicular screws in the thoracic, lumbar and sacral spine using the free hand technique. METHODS: Clinical and imaging (CT scan) evaluation of 25 patients (13 female and 12 male) undergoing spinal instrumentation for a total of 124 transpedicular screws applied using the free hand technique. The screws were inserted from T11 to S1, most of which were placed at levels L4, L5 and S1. RESULTS: 94% of transpedicular screws were placed correctly in the pedicle. It was found that 6% (seven screws) were misplaced and among those, only two violated the inferomedial wall, one less than 2 mm and the other between 2 and 4 mm. None of the patients had complications associated with incorrect positioning of the screws. CONCLUSION: The free hand technique is safe to be used in the instrumentation of the thoracic, lumbar and sacral spine.


OBJETIVO: Evaluar la colocación de tornillos transpediculares utilizados en las vértebras de la columna torácica, lumbar y sacra, introducidos mediante la técnica free hand. MÉTODOS: Evaluación clínica y radiológica (Tomografía Computadorizada) de 25 pacientes (13 mujeres y 12 hombres) sometidos a la instrumentación espinal para un total de 124 tornillos transpediculares aplicados mediante la técnica free hand. Los tornillos se insertaron desde T11 a S1, la mayoría de los cuales fueron colocados en los niveles L4, L5 y S1. RESULTADOS: 94% de los tornillos transpediculares se colocaron correctamente en el pedículo. Se encontró que 6% (siete tornillos) se colocaron mal; de estos, solamente dos habían sobrepasado la cortical inferomedial, uno presentaba una perforación inferior a 2 mm y el otro entre 2 y 4 mm. Ninguno de los pacientes acompañados tuvo complicaciones asociadas con la colocación incorrecta de los tornillos. CONCLUSIÓN: La técnica free hand es segura en la instrumentación de la columna torácica y, lumbosacra.


Subject(s)
Humans , Lumbar Vertebrae/surgery , Spinal Fusion , Spine/surgery , Bone Screws
2.
Rev. bras. hematol. hemoter ; 29(2): 149-152, abr.-jun. 2007. ilus, tab
Article in Portuguese | LILACS | ID: lil-467874

ABSTRACT

A lise das hemácias, de causa imune ou não imune, pode provocar a elevação da hemoglobina plasmática induzindo efeitos deletérios principalmente nos rins e no sistema cardiovascular. Este trabalho objetiva evidenciar o possível efeito hemolítico induzido pelo trauma mecânico provocado pela passagem das hemácias em diferentes modelos de bombas de infusão de soluções, em concentrados de hemácias com até dez dias de armazenamento, preparados com Sag-Manitol. Foram utilizados três modelos de bombas (Nutrimat, Infusomat Compact e Volumed), com quatro aparelhos de cada modelo, testados em três velocidades de infusão (120 mL/h, 240 mL/h e 360 mL/h). Os parâmetros utilizados para evidenciar o grau de hemólise foram o percentual de hemólise e os níveis de hemoglobina e potássio livres no plasma. As amostras foram coletadas antes da passagem do concentrado de hemácias pelas bombas, na metade do tempo de infusão e no final da infusão, nas diferentes velocidades. Não ocorreu variação significativa entre os valores dos parâmetros analisados nas amostras controle e naquelas coletadas nas diferentes velocidades, marcas de bombas, mecanismos de infusão entre as bombas da mesma marca e entre os diferentes tempos de infusão. A principal variação encontrada foi relacionada com o potássio livre, devido à variação inerente aos próprios concentrados, o que foi evidenciado ao se compararem os valores obtidos nas amostras controle e nas amostras colhidas nos tempos médio e final em cada bomba. De acordo com os resultados obtidos, não houve alteração estatisticamente significativa do percentual de hemólise após a passagem pelas bombas de infusão nos modelos analisados.


The lyses of red blood cells, both for immune or non-immune reasons, can cause an elevation in plasmatic hemoglobin, inducing harmful effects mainly in the kidneys and cardiovascular system. This work aims at identifying the possible hemolytic effect, related to mechanical trauma due to the use of different models of infusion pumps, on red blood cells transfused after up to ten days of storage. Three models of pumps were studied (Nutrimat, Infusomat Compact and Volumed), (four devices of each model) with three infusion speeds being tested (120 mL/h, 240 mL/h and 360 mL/h). The parameters used to report the degree of hemolysis were the percentile of hemolysis, hemoglobin levels and free potassium in the plasma. Samples were collected before infusion of red blood cells using the pumps, half way through infusion (1/2 T) and at the end of infusion (T), for the three different speeds. Significant variations were not seen in the analyzed parameters between the control samples and those collected at different speeds, using different models of pumps and infusion mechanisms and among pumps of the same brand and at different infusion times. The greatest variation found involved free potassium, probably due to the different levels found in red blood cell concentrates seen when control samples were compared to values obtained half way through and at the end of infusion for each pump. In agreement with the obtained results changes in the percentile of hemolysis were not found after infusion of the cells using the different infusion pumps.


Subject(s)
Hemolysis , Blood Transfusion , Infusion Pumps , Erythrocytes
3.
Rev. bras. hematol. hemoter ; 27(2): 83-86, abr.-jun. 2005. ilus
Article in Portuguese | LILACS | ID: lil-422479

ABSTRACT

O fator de Leiden é uma mutacão genética que predispõe seus portadores ao tromboembolismo venoso. O objetivo do estudo foi investigar a distribuicão dos alelos em 21 membros da família de três pacientes portadores de trombose com a presenca da mutacão do fator V de Leiden. A deteccão da mutacão no gene do fator V foi realizada entre portadores da mutacão no estado heterozigoto. Este estudo foi realizado no Centro de Hematologia e Hemoterapia do Ceará - Hemoce. Observou-se a presenca da mutacão no estado heterozigoto na família 1 (83,3 por cento), na família 2 (40 por cento) e na família 3 (50 por cento). No total de 24 membros (pacientes e familiares) analisados, 50 por cento (12/24) apresentaram a mutacão, todos no estado heterozigoto, 66,7 por cento (8/12) não apresentaram trombose. A deteccão do fator V de Leiden em pacientes portadores de eventos trombóticos é recomendado para esclarecimento das causas e para efetuar o rastreamento em membros de sua família, ainda sem o aparecimento de eventos trombóticos, de forma a avaliar os riscos associados e assim determinar um acompanhamento médico preventivo.


Subject(s)
Male , Female , Child, Preschool , Adolescent , Adult , Middle Aged , Humans , Factor V , Genetic Carrier Screening , Thromboembolism , Thrombophilia , Prevalence
4.
Rev. Inst. Adolfo Lutz ; 62(1): e34941, 2003.
Article in Portuguese | LILACS, ColecionaSUS, SES-SP, CONASS, SESSP-IALPROD, SES-SP, SESSP-IALACERVO | ID: lil-352823

ABSTRACT

Com o objetivo de avaliar as condições higiênicas dos refrigerantes, foram analisadas 100 amostras de diferentes marcas, nos sabores de cola, guaraná e frutas. As amostras, em embalagens Pet 2 litros, foram coletadas aleatoriamente no período de março a novembro de 2000, em estabelecimentos comerciais, pela Vigilância Sanitária do Estado (VISA/MG). Foram utilizadas duas metodologias distintas para enumeraçäo de fungos viáveis em bebidas e Número Mais Provável para bactérias do grupo Coliforme (APHA, 1992). A primeira técnica utilizada para enumeraçäo de fungos foi a do espalhamento em superfície, em placas contendo o meio Dicloran Rosa de Bengala Cloranfenicol (DRBC), e a segunda, a técnica de membrana filtrante, empregando dois meios: M-Green Yeast and Mold e o meio DRBC. 13 por cento das amostras foram condenadas como produtos em condições higiênicas insatisfatórias por apresentarem contagens de bolores e leveduras superiores à 20UFC/mL (Portaria 451/97 do MS/SVS-ítem XII, inciso a). Destas, 46,2 por cento apresentaram leveduras, 30,8 por cento leveduras e fungos filamentosos, e 23 por cento fungos filamentosos. Näo foram detectadas bactérias do grupo coliforme (ausência em 50mL da amostra). Das amostras condenadas, 92,3 por cento eram provenientes de indústrias classificadas como ruins ou precárias de acordo com suas instalações. (AU)


The aim of this study was to evaluate the hygienic and sanitary quality of soft drinks ofdifferent commercial brands, flavours cola, guaraná and fruits. The samples (2 liters Pet) were randomlycollected in commercial establisments by the Inspection Service (VISA/MG). Two methodologies wereused to enumerate viable fungi in beverages (APHA, 1992). The first one was the surface spread-platetechnique using Dicloran Rose Bengal Chloranphenicol medium, and the second one was the membranefilter technique, and media: M-Green Yeast and Mold and DRBC medium . 13% of the soft drink samplesshowed levels of yeast and mold higher than 20 CFU/mL being classified as unacceptable because of itshygienic conditions (Portaria 451/97 of MS/SVS ­ item XII-a). 46.2% of these samples presented yeasts,30% yeasts and molds, and 23% molds. Coliforms were not detected in the samples. 92.3% of theunacceptable samples were provenient from industries classified as bad or precarious according to theirpremises.(AU)


Subject(s)
Yeasts , Carbonated Beverages , Coliforms , Food Microbiology , Fungi
SELECTION OF CITATIONS