Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add filters








Language
Year range
1.
Chinese Journal of Postgraduates of Medicine ; (36): 903-909, 2022.
Article in Chinese | WPRIM | ID: wpr-955420

ABSTRACT

Objective:To study the value of shear wave elastography (SWE) combined with contrast-enhanced ultrasound (CEUS) in diagnosing the invasiveness of papillary thyroid microcarcinoma (PTMC), and analyze its risk factors.Methods:This study included 200 patients with pathologically confirmed PTMC who underwent surgery in Fenyang Hospital from January 2019 and June 2021. All were diagnosed with SWE and CEUS before surgery. The value of the two methods in diagnosing the invasiveness of PTMC was explored. The patients′ data were collected to screen the risk factors for the invasiveness of PTMC.Results:It was pathologically confirmed that among the 200 patients with PTMC, there were 112 cases with malignant nodules, 88 cases with benign nodules, 75 cases with cervical lymph node metastasis (including 71 cases with capsular invasion) and 125 cases without lymph node metastasis. CEUS parameters of malignant nodules were significantly higher than those of benign nodules ( P<0.05). The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of SWE combined with CEUS to diagnose capsular invasion were 94.66%, 85.60%, 89.00%, 79.77% and 96.39%, with high consistency with the pathological results ( Kappa>0.75). Multivariate Logistic regression analysis showed that multiple foci, irregular shape, breakthrough capsule and small calcification were independent risk factors for the invasiveness of PTMC (VIF<3). The ROC curve results showed that the AUC of SWE combined with CEUS to diagnose capsular invasion was 0.772, and the diagnostic sensitivity and specificity were 73.91% and 80.56%. Conclusions:SWE combined with CEUS can significantly improve the diagnostic accuracy for the invasiveness of PTMC.

2.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 3130-3133, 2016.
Article in Chinese | WPRIM | ID: wpr-504199

ABSTRACT

Objective To study the difference between ultrasound contrast and conventional ultrasound guided superficial lymph node biopsy.Methods The patients who received superficial lymph node biopsy were randomly divided into observation group (40 cases)and control group (40 cases),the patients were divided into the observation group and the control group.In the control group,conventional ultrasound was used to guide.Patients in the observation group were guided by ultrasound contrast.Specimens of pathological satisfaction rate,diagnostic accu-racy rate and the recovery rate of patients between two groups were compared.Results The pathological satisfaction rate of the control group was 83.2%,the observation group was 96.9%,and the difference between the two groups was statistically significant(χ2 =3.95,P <0.05).The diagnostic accuracy rate of the control group was 82.5%,the observation group was 95.0%,the difference between the two groups was statistically significant(χ2 =4.26,P <0.05).The recovery rate of the control group was 87.5%,and the recovery rate was 97.5% in the observation group, and the difference was statistically significant(χ2 =6.71,P <0.05).Conclusion Compared with conventional ultra-sound,ultrasound imaging has a greater advantage in guiding superficial lymph node biopsy.

3.
China Pharmacy ; (12): 2989-2990,2991, 2015.
Article in Chinese | WPRIM | ID: wpr-605077

ABSTRACT

OBJECTIVE:To establish a method for content determination of phosphatidylcholine in eustachian tube lavage fluid of patients with secretory otitis media. METHODS:HPLC was used. The samples were pretreated by liquid-liquid extraction. It was performed on the column of Hypersil CN with mobile phase of acetoneitril-methanol-phosphoric acid (100∶10∶0.6,V/V/V)at the flow rate of 1.8 ml/min,the detection wavelength was 205 nm,temperature was 30 ℃ and volume was 20 μl. RESULTS:The lin-ear range of phosphatidylcholine was 11.99-119.9 μg/ml(r=0.999 6);RSDs of precision tests of intra-day and inter-day were no more than 15%;average recovery was 97.54%(RSD=9.36%,n=9);the average content of phosphatidylcholine in eustachian tube lavage fluid of patients was(24.43±3.61)μg/ml. CONCLUSIONS:The method is simple and accurate,and can be used for the content determination of phosphatidylcholine in eustachian tube lavage fluid of patients with secretory otitis media.

4.
China Pharmacy ; (12)2005.
Article in Chinese | WPRIM | ID: wpr-528756

ABSTRACT

OBJECTIVE:To determine the content of glycyrrhetic acid in zhenkening capsules by RP-HPLC.METHODS:The separation was performed on Hypersil C 18,the mobile phase consisted of methanol-water-glacial acetic acid(87∶13∶2.5)with flow rate at 1.0ml/min and detection wavelength at 254nm,the column temperature was set at room temperature.RE-SULTS:The calibration cure of glycyrrhetic acide was linear in the concentration range of 10~120?g/ml(r=0.9999),the average recovery was 99.68%(RSD=0.49%).CONCLUSION:This method is simple,fast,accurate,and suitable for the determination of glycyrrhetic acid in zhenkening capsules.

5.
Chinese Journal of Medical Education Research ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-624212

ABSTRACT

To arouse students’autonomous study,a reform was carried out in experimen- tal teaching of preventive medicine. Taking exploratory experiment as a cut-in point,students were free to choose subjects,design blueprint,do spot research and compose papers etc.,which efficiently inspired students’learning interest and exploring spirit,cultivated their creative think-ing and researching ability.

6.
China Pharmacy ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-519907

ABSTRACT

OBJECTIVE:To observe the effect of electrolytes on the stability of fat emulsion in ALL IN ONE.METHODS: The size of fat emulsion particulates was observed under microscope in 400 - fold magnification.The oil - water demixing was observed with naked eye.RESULTS:The higher the concentration of electrolytes,the stronger the influence on the fat emulsion particulates aggregation and the easier the oil - water demixing appeared.The influence of bivalent ions was stronger than that of monovalent ones.The longer the mixture stored the stronger the influence.CONCLUSION:In order to keep the stability of ALL IN ONE,the concentrations of electrolytes should not be too high,and ALL IN ONE must be used up in 24 hours.

7.
China Pharmacy ; (12)1991.
Article in Chinese | WPRIM | ID: wpr-531700

ABSTRACT

OBJECTIVE:To evaluate the effects of arginine-enriched total parenteral nutrition(TPN)on the nutritional and immune parameters of patients undergoing abdominal surgery.METHODS:67 patients undergoing abdominal surgery were randomly assigned to receive routine TPN(control group,n=24),TPN plus 15 g arginine(n=25,trial group Ⅰ)or TPN plus 30 g arginine(n=18,trial group Ⅱ)for 3 days postoperatively.RESULTS:Arginene-enriched TPN significantly improved postoperative nitrogen balance,promoted the recovery of plasma-albumin and total protein,and elevated the levels of CD4+ and CD4+/CD8+,but no significant difference was noted for immunoglobulin,complement C3 and complement C4 during trial period.CONCLUSION:Arginene-enriched TPN can improve patients' postoperative nutritional and immune parameters and enhance the efficacy of TPN support.

8.
China Pharmacy ; (12)1991.
Article in Chinese | WPRIM | ID: wpr-529944

ABSTRACT

OBJECTIVE:To investigate the absorbability polyvinylidene chloride(PVC) infusion vessel to ciclosporin.METHODS:The concentration of ciclosporin was determined by HPLC after storing in the PVC infusion packages or glass bottle for different period of time and its change was investigated as well.RESULTS:The adsorption rate of PVC infusion vessel to ciclosporin increased time-dependently,with a peak value of 38.66% at 12 h,which was significant as compared with glass infusion bottle at the same time.CONCLUSION:The PVC infusion package has stronger absorbability to ciclosporin,thus its use should be avoided if possible.

9.
China Pharmacy ; (12)1991.
Article in Chinese | WPRIM | ID: wpr-522842

ABSTRACT

OBJECTIVE:To study the preparation of the ligustrazine hydrochloride liposome and evaluate its quality.METHODS:The liposome was prepared by various methods on a trial basis.The entrapped efficiency(EE)of the liposome derived from passive loading and active loading was compared.RESULTS:The ammonim sulfate gradient technology had the highest EE of 48.63%and its mean size was 6.5?m and the pH was 5.93.It was stable in refrigeratory(4℃~10℃)storage for 30 days.CONCLUSION:The ammonim sulfate gradient technology of preparation of the ligustrazine hydrochloride liposome is feasible.

SELECTION OF CITATIONS
SEARCH DETAIL