Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Rev. chil. neurocir ; 37: 69-72, jul. 2011. ilus
Article in English | LILACS | ID: lil-708079

ABSTRACT

Schistosomiasis is an infection caused by trematodes (flatworms from the phylum Platyhelminthes), which are acquired transcutaneously by swimming in contaminated waters. The central nervous system (CNS) schistosomiasis is a rare presentation of the disease. Brain infection to S. Mansoni has been rarely reported, in anedoctal fashion. It should be recognized early, since it disposes a specific treatment, and this treatment may prevent neurological deterioration. A high index of suspicion is necessary, mainly in patients coming from endemic areas, with brain or spinal cord lesions associated with eosinophilia and inflammatory CSF. Finding eggs from schistosoma into excrements or CNS biopsy confirms the diagnosis. We describe a 35-year old Brazilian man, harboring an isolated brain infection to S. mansoni.


Subject(s)
Humans , Male , Adult , Schistosomiasis/surgery , Schistosomiasis/diagnosis , Schistosomiasis/etiology , Schistosomiasis/physiopathology , Infections , Parasitic Diseases , Trematode Infections , Brazil
2.
Acta cir. bras ; 21(6): 385-391, Nov.-Dec. 2006. ilus, tab
Article in English | LILACS | ID: lil-440745

ABSTRACT

PURPOSE: To evaluate tests performed to confirm the position of the Veress needle inserted into the left hypochondrium for creation of pneumoperitonium. METHODS: One hundred patients were submitted to laparoscopic procedure with left hypochondrium puncturing. Needle positioning tests were evaluated. The aspiration test was considered positive when organic material was aspirated; the injection test was considered positive when no increased resistance to liquid injection was observed; the recovery test was considered positive when the liquid injected was not recovered; the saline drop test was considered positive when drops of saline in the syringe disappeared quickly; the initial intraperitoneal pressure test was considered positive when pressure levels were £ 8 mmHg. A positive aspiration test indicated iatrogenic injury, whereas a positive result in any of the other tests indicated that the tip of the needle was correctly positioned in the peritoneal cavity. Sensitivity (SE), specificity (SP), positive predictive value (PPV) and negative predictive value (NPV) of the tests were calculated by correlating results considered true positives (a), false positives (b), false negatives (c) and true negatives (d), according to the formulas: SE = [a/(a + c)] x 100; SP = [d/(b + d)] x 100; PPV = [a/(a + b)] x 100; NPV = [d(c + d)] x 100. RESULTS: With regard to the aspiration test, SE and PPV were not applicable, SP was 100 percent and NPV was 100 percent. With regard to the injection test, SE was 0 percent, SP was 100 percent, PPV was inexistent and NPV was 90 percent. Both recovery and saline drop tests yielded the following results: SE was 50 percent, SP was 100 percent, PPV was 100 percent and NPV was 94.7 percent. The initial intraperitoneal pressure test yielded the following results: SE, SP, PPV and NPV were 100 percent. CONCLUSIONS: When inserting the Veress needle into the left hypochondrium, a negative aspiration test guarantees...


OBJETIVO: Avaliar provas de posicionamento da agulha de Veress introduzida no hipocôndrio esquerdo para criação de pneumoperitônio. MÉTODOS: Cem pacientes foram submetidos a laparoscopia com punção no hipocôndrio esquerdo. Provas de posicionamento da agulha foram avaliadas. A prova da aspiração foi considerada positiva quando sugava-se material orgânico; a prova da resistência foi considerada positiva quando apenas pouca pressão à infusão de líquido era observada; a prova de recuperação foi considerada positiva quando o líquido infundido não era recuperado; a prova do gotejamento foi considerada positiva quando gotas depositadas na agulha escoavam rapidamente; a prova da pressão intraperitoneal inicial foi considerada positiva quando os níveis observados eram d" 8 mmHg. Uma prova de aspiração positiva indicava iatrogenia, ao passo que resultados positivos em todas as outras provas indicavam que a ponta da agulha estava adequadamente posicionada na cavidade peritoneal. Foram calculadas a sensibilidade (S), especificidade (E), valores preditivos positivos (VPP) e negativos (VPN) das provas, mediante correlação dos resultados verdadeiro-positivos (a), falso-positivos (b), falso-negativos (c) e verdadeiro-negativos (d), segundo as fórmulas: S = [a/(a + c)] x 100; E = [d/(b + d)] x 100; VPP = [a/(a + b)] x 100; VPN = [d(c + d)] x 100. RESULTADOS: Na prova da aspiração, constatou-se que S e VPP não puderam ser aplicados, e que E = 100 por cento e VPN = 100 por cento. Na prova da resistência, S = 0 por cento, E = 100 por cento, VPP = não existiu e VPN = 90 por cento. Tanto na prova da recuperação como na do gotejamento, S = 50 por cento, E = 100 por cento, VPP = 100 por cento e VPN = 94,7 por cento. Na da pressão inicial, S, E, VPP e VPN = 100 por cento. CONCLUSÕES: Na punção no hipocôndrio esquerdo, um resultado negativo na prova da aspiração garante ausência de iatrogenia; a prova da resistência não indica com certeza o mau posicionamento...


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Abdomen/surgery , Laparoscopy/methods , Needles , Pneumoperitoneum, Artificial , Peritoneal Diseases/surgery , Punctures/methods , Abdominal Wall , Injections, Intraperitoneal , Laparoscopes , Laparoscopy/standards , Predictive Value of Tests , Pressure , Prospective Studies , Pneumoperitoneum, Artificial/methods , Punctures/standards
3.
Rev. Col. Bras. Cir ; 33(5): 279-284, set.-out. 2006. ilus, graf
Article in Portuguese | LILACS | ID: lil-448872

ABSTRACT

OBJETIVO: Avaliar provas de posicionamento da agulha de Veress no hipocôndrio esquerdo na criação do pneumoperitônio. MÉTODO: Em cem pacientes puncionados no hipocôndrio esquerdo, provas de posicionamento da agulha foram avaliadas, considerando-as positivas quando, na prova da aspiração (PA), material orgânico era aspirado; na prova da resistência (PRes), exercia-se pequena força no êmbolo da seringa à infusão de líquido; na prova da recuperação (PRec), não se recobrava o líquido infundido; na do gotejamento (PG), as gotas escoavam rapidamente e, na prova da pressão intraperitoneal inicial (PPII), os níveis eram = 8mmHg. PA positiva denunciava iatrogenia, enquanto que PRes, PRec, PG e PPII positivas indicavam que a ponta da agulha estava adequadamente posicionada na cavidade peritoneal. Foram calculadas a sensibilidade (S) e a especificidade (E) das provas, e os seus valores preditivos positivos (VPP) e negativos (VPN), mediante correlação dos resultados verdadeiro-positivos (a), falso-positivos (b), falso negativos (c) e verdadeiro-negativos (d), segundo as fórmulas: S=[a/(a+c)]x100; E=[d/(b+d)]x100; VPP=[a/(a+b)]x100; VPN=[d(c+d)]x100. RESULTADOS: Na PA, constatou-se que S e VPP não puderam ser aplicados, e E=100 por cento e VPN=100 por cento. Na PRes, S=0 por cento, E=100 por cento, VPP=não existiu e VPN=90 por cento. Tanto na PRec quanto na PG, S=50 por cento, E=100 por cento, VPP=100 por cento e VPN=94,7 por cento. Na PPII, obteve-se que S, E, VPP e VPN=100 por cento. CONCLUSÕES: Na punção no hipocôndrio esquerdo, PA negativa garante ausência de lesões; a PRes é insegura quanto ao mau posicionamento da agulha, mas indica corretamente o bom; a PRec e a PG não reconhecem bem o adequado posicionamento, mas detectam com segurança o inadequado; a PPII acusa com segurança tanto o mau quanto o bom posicionamento da agulha, sendo a prova mais confiável dentre as estudadas.


BACKGROUND: To evaluate tests for Veress needle tip placement intraperitoneally in the left hypochondrium for creating a pneumoperitoneum. METHODS: Needle tip placement tests were evaluated in one hundred patients using the left hypochondrium area. It was considered positive when: aspiration test (PA) -returned organic material; resistance test (PRes) - a low pressure was pushed on the syringe for the liquid infusion; recovery test (PRec) - no liquid was recovered after infusion; dripping test (PG) - drops drained quickly; test for initial intraperitoneal pressure (PPII) - levels were <= 8mmHg. Positive PA suggested bowel injury, while positive PRes, PRec, PG and PPII indicated that needle tip was adequately located in the peritoneal cavity. The Sensitivity ( SE) and Specificity ( SP ), as well as their predictive positive values (PPV) and predictive negative values ( PNV) of these tests were calculated using results correlation which were true-positives (a), false-positives (b), false-negatives (c) and true-negatives (d), accordingly to the formulas: SE =[a/ (a+c)]x100; SP =[d/(b+d)]x100; PPV=[a/(a+b)]x100; PNV=[d(c+d)]x100. RESULTS: If a positive PA had returned, SE and PPV did not fit, and SP=100 percent and PNV =100 percent. In the PRes, SE =0 percent, SP =100 percent, PPV = did not exist and PNV =90 percent. Both in the PRec and in the PG, results were for SE =50 percent, SP =100 percent, PPV =100 percent and PNV =94.7 percent. In the PPII test results were for SE, PPV and PNV =100 percent. CONCLUSION: Left hypochondrium negative PA guaranteed that bowel was not perforated; PRes test is a not accurate test for detection of the needle tip bad placement, however it accurately indicates its good positioning; PRec and the PG tests do not detect the adequate positioning, but they detect very well the inadequate positioning; PPII test shows with reliability both bad and good positioning of the needle, being the most trustworthy test among...

4.
Acta cir. bras ; 21(5): 296-303, Sept.-Oct. 2006.
Article in English, Portuguese | LILACS | ID: lil-438754

ABSTRACT

PURPOSE: To test the efficacy of the puncture in the left hypochondrium as an alternative method. METHODS: Sixty-two patients randomly distributed into two groups were studied: Group LH, puncture in the left hypochondrium (n=30), and Group ML, puncture in the abdominal midline (n=32). The following were assessed: needle positioning tests, number of failed attempts at needle insertion, and time needed for creation of pneumoperitoneum. Gas flow, volume and intraperitoneal pressure were recorded at every 20 seconds, until a 12 mmHg pressure was reached inside the peritoneal cavity. RESULTS: A similar number of positive results for the needle positioning tests were observed in both groups. Two failed attempts to reach the peritoneal cavity were observed in Group ML and one in Group LH. The time necessary for the creation of pneumoperitoneum was on average 3 minutes and 46 seconds for Group LH, and 4 minutes and 2 seconds for Group ML. Average gas flow, volume and pressure were equivalent for both groups. CONCLUSION: Puncture in the left hypochondrium was as effective as puncture in the abdominal midline for the creation of pneumoperitoneum.


OBJETIVO: Avaliar a eficácia e segurança da punção alternativa no hipocôndrio esquerdo. MÉTODOS: Sessenta e dois pacientes distribuídos aleatoriamente em dois grupos foram estudados prospectivamente: grupo HE, punção no hipocôndrio esquerdo (n=30) e grupo LM, punção na linha média do abdome (n=32). Foram avaliados os testes de posicionamento da agulha, o número de tentativas frustradas e a duração da instalação do pneumoperitônio. Os fluxos correntes, as pressões intraperitoneais e os volumes injetados foram registrados a cada 20 segundos, até 12 mmHg. RESULTADOS: O número de resultados positivos aos testes de posicionamento da agulha foi semelhante em ambos os grupos. Ocorreram duas tentativas infrutíferas de punção no grupo LM e uma no grupo HE. O tempo necessário para o estabelecimento do pneumoperitônio foi, em média, 3 minutos e 46 segundos para o Grupo HE e 4 minutos e 2 segundos para o grupo LM. As médias dos fluxos, das pressões e dos volumes foram respectivamente equivalentes entre os grupos.. CONCLUSÃO: A punção no HE foi tão eficaz no estabelecimento do pneumoperitônio quanto a punção na LM do abdome.


Subject(s)
Humans , Male , Female , Adult , Abdomen/surgery , Laparoscopy/methods , Needles , Pneumoperitoneum, Artificial/instrumentation , Punctures/methods , Abdomen/physiology , Pressure , Pneumoperitoneum, Artificial/methods , Time Factors
5.
Rev. Col. Bras. Cir ; 33(4): 220-223, jul.-ago. 2006. graf, tab
Article in Portuguese | LILACS | ID: lil-448859

ABSTRACT

OBJETIVO: Avaliar a possibilidade do estabelecimento de parâmetros fidedignos do adequado posicionamento da ponta da agulha de Veress no interior da cavidade peritoneal durante o estabelecimento do pneumoperitônio. MÉTODO: Em 100 pacientes selecionados a ponta da agulha de Veress foi introduzida na cavidade peritoneal e o insuflador foi programado para fluxo de 1,2L/min e pressão máxima final para 12mmHg. No início da insuflação e a cada 20 segundos a pressão intraperitoneal (PI) e o total do volume injetado até aquele momento (TVI) eram registrados. Os dados foram tratados por correlações estatísticas entre momentos e PI, e momentos e TVI. Também foi estabelecida a previsão dos valores de PI e TVI no final de cada um dos quatro primeiros minutos de insulflação, utilizando-se os modelo estimados: PI = 2,3083 + 0,0266 x tempo + 8,3x10-5 x tempo³ - 2,44x10-7 x tempo³ ; TVI = 0,813 + 0,0157 x tempo. RESULTADOS: A PI e o TVI mostraram correlação entre momentos pré-estabelecidos da criação do pneumoperitônio, sendo constatado um ajuste forte: PI = -2E - 07 x tempo³ + 8E - 05 x tempo² + 0,0266 x tempo + 2,3083, com coeficiente de explicação (R2) = 0,8011; TVI = 0,0157 x tempo + 0,1813, com R2 = 0,9604. A previsão de PI e TVI mostrou: PI(mmHg): 1min=4,15; 2min=6,27; 3min=8,36; 4min=10,10 e TVI(L): 1min=1,12; 2min=2,07; 3min=3,01; 4min=3,95. CONCLUSÕES: Parâmetros fidedignos para PI e TVI , quando a ponta da agullha de Veress se encontra na cavidade peritoneal, em dados momentos da insuflação podem ser estabelecidos durante a criação do penumoperitônio.


BACKGROUND: To evaluate the possibility of establishing reliable parameters for the appropriate positioning of Veress needle tip in the peritoneal cavity during pneumoperitoneum creation. METHODS: In 100 selected patients Veress needle tip were introduced in the peritoneal cavity and the insufflators were programmed for a flow of 1,2L/min and with final maximum pressure of 12mmHg. At the beginning of the insufflation and at every 20 seconds the intraperitoneal pressure (IP) and the total volume injected (TVI) were recorded. Data was treated by statistical correlation between moments and IP, and moments and TVI. The forecast values of IP and TVI at the end of each one of the four first insufflation minutes were also established, using the following estimated formulas: IP = 2.3083 + 0.0266 x time + 8.3x10-5 x time³ - 2.44x10-7 x time³; TVI = 0.813 + 0.0157 x time. RESULTS: IP and TVI showed a correlation between pre-established moments of pneumoperitoneum creation when a strong adjustment became apparent: IP = -2E - 07 x time³ + 8E - 05 x time² + 0.0266 x time + 2.3083, with a coefficient of explanation: (R2) = 0.8011; TVI = 0.0157 x time + 0.1813, with R2=0.9604. The forecast of IP and TVI showed: IP (mmHg): 1min=4.15; 2 min=6.27; 3 min=8.36; 4 min=10.10 and TVI (L): 1min=1.12; 2 min=2.07; 3 min=3.01; 4 min=3.95. CONCLUSION: Reliable parameters for IP and TVI can be established during pneumoperitoneum creation when the Veress needle tip is located in the peritoneal cavity in a given insufflation moment.

6.
Acta cir. bras ; 21(1): 26-30, Jan.-Feb. 2006. ilus, tab, graf
Article in English | LILACS | ID: lil-420967

ABSTRACT

OBJETIVO: Estabelecer parâmetros fidedignos do posicionamento adequado da agulha de Veress na cavidade peritoneal durante o estabelecimento do pneumoperitônio pela técnica fechada. MÉTODOS: Em 11 porcos a agulha foi introduzida na cavidade peritoneal através do hipocôndrio esquerdo. Provas de posicionamento da ponta do instrumento foram efetuadas. Insuflou-se CO2 e registraram-se periodicamente pressões, fluxos e volumes. A posição intraperitoneal da agulha foi confirmada e esta foi retirada, sendo re-introduzida no hipocôndrio direito e posicionada sob visão direta no espaço pré-peritoneal. Os mesmos parâmetros foram aferidos. RESULTADOS: A prova do escoamento foi sempre positiva no peritônio. Não se encontrou resistência à introdução de soro no peritônio em nenhum caso, mas sim em 45,5% dos casos no pré-peritônio. Soro algum foi recuperado em 63,5% no peritônio e em 54,5% no pré-peritônio. O gotejamento fluiu livremente em 66,6% das vezes no peritônio e em 45,5% dos casos no pré-peritônio. No peritônio, pressões iniciais de 5,20 mmHg aumentaram progressivamente durante 123 segundos até atingir 15 mmHg. No pré-peritônio a pressão inicial foi de 15,60 mmHg e oscilou entre 12 e 15,60 mmHg. O volume de gás injetado no peritônio foi de 1500 ml e de 100 ml no pré-peritônio. CONCLUSÕES: Aspiração e observação do escoamento e do gotejamento são importantes; recuperar ou não o soro é inconclusivo. Pressão inicial d" 5 mm é indicativo da ponta da agulha no peritônio, onde devem caber dez vezes mais gás que no pré-peritônio. No peritônio os aumentos das pressões e dos volumes pode ser previstos mediante estatísticas.


Subject(s)
Animals , Male , Female , Laparoscopy/methods , Needles , Pneumoperitoneum, Artificial/standards , Punctures/methods , Disease Models, Animal , Evaluation Study , Laparoscopy/standards , Pneumoperitoneum, Artificial/methods , Punctures/standards , Sensitivity and Specificity , Swine
7.
Rev. Col. Bras. Cir ; 32(5): 273-278, set.-out. 2005. ilus, tab
Article in Portuguese | LILACS | ID: lil-428694

ABSTRACT

OBJETIVO: Na criação do pneumoperitônio com agulha de Veress por punção na linha média do abdome têm sido relatados acidentes que, apesar de raros, afetam freqüentemente os grandes vasos. O objetivo desta pesquisa é testar a eficácia da punção alternativa no hipocôndrio esquerdo e avaliar a eficácia e segurança desta punção. MÉTODO: Sessenta e dois pacientes distribuídos aleatoriamente em dois grupos foram estudados prospectivamente: grupo HE, punção no hipocôndrio esquerdo (n = 30), e grupo LM, punção na linha média do abdome (n = 32). Foram avaliados os testes de posicionamento da agulha, o número de tentativas frustradas e a duração da instalação do pneumoperitônio. Os fluxos correntes, as pressões intraperitoneais e os volumes injetados foram registrados a cada 20 segundos, até 12mmHg. RESULTADOS: Os testes de posicionamento foram positivos em ambos os grupos. Ocorreram duas tentativas infrutíferas de punção no grupo LM e uma no grupo HE. O tempo de duração para o estabelecimento do pneumoperitônio foi em média de 3 minutos e 46 segundos para o Grupo HE e de 4 minutos e 2 segundos para o grupo LM. As médias dos fluxos, das pressões e dos volumes foram respectivamente equivalentes entre os grupos. A análise estatística demonstrou que a punção no HE foi tão eficaz no estabelecimento do pneumoperitônio quanto a punção na LM do abdome. CONCLUSÕES: A punção no HE deve ser o local de escolha para a punção com agulha de Veress na criação do pneumoperitônio artificial pela técnica fechada, por ser segura e eficaz.

8.
Rev. bras. colo-proctol ; 24(4): 300-307, out.-dez. 2004. tab
Article in Portuguese | LILACS | ID: lil-405039

ABSTRACT

O objetivo desse estudo foi analisar os fatores que influenciam a sobrevivência de doentes selecionados submetidos à extirpação com intenção curativa de metástases hepáticas do carcinoma colo-retal. Foram operados 41 doentes. Foi considerado critério de exclusão presença de quatro ou mais lesões hepáticas. Vinte e três (56,1por cento) enfermos eram homens e 18 (43,9por cento) mulheres. A média de idade foi 63,8 11,5 anos. A neoplasia colo-retal estava localizada no colo esquerdo em 16 (39,0por cento) doentes, no reto em 15 (36,6por cento) e no colo direito em dez (24,4por cento). Foram utilizados os seguintes modelos estatísticos: média aritmética e desvio padrão, mediana, análise de variância por regressão logística para verificação de fatores de risco e curva de Kaplan-Meier para a análise de sobrevivência de grupos. A média de sobrevivência foi de 38,9 4,5 meses (0,4 a 60,6 meses). Não houve mortalidade operatória. Quinze (36,6por cento) doentes faleceram: nove (21,9por cento) enfermos por carcinomatose peritoneal, quatro (9,6por cento) por doenças benignas e dois (4,9por cento) por causa ignorada. Vinte e seis (63,4por cento) enfermos sobreviveram à extirpação da metástase hepática, com média de sobrevivência de 19,3 meses (2 a 60,8 meses). O intervalo médio livre de doença foi de 15,3 meses. A mortalidade dos doentes com carcinoma no reto foi significativamente maior (p=0,04) do que a dos enfermos com lesões localizadas no colo direito ou esquerdo. Os autores concluíram que nesse grupo de doentes selecionados, a localização retal da neoplasia primária influenciou significativa e desfavoravelmente a sobrevivência dos enfermos submetidos à extirpação das metástases hepáticas do carcinoma colo-retal.


Subject(s)
Humans , Middle Aged , Carcinoma , Colorectal Neoplasms , Liver Neoplasms/surgery , Liver Neoplasms/secondary , Survival
9.
GED gastroenterol. endosc. dig ; 18(5): 209-212, set.-out. 1999. ilus
Article in Portuguese | LILACS | ID: lil-316490

ABSTRACT

Os autores relatam detalhes clínicos e cirurgícos de um caso de DAM, cujo diagnóstico foi achado de videolaparoscopia diagnosticada exploradora, indicada para elucidar o diagnóstico diferencial de AAI, em doente do sexo feminino, em idade fértil (39anos) O tratamento instituido foi a diverticulectomia de Meckel, com aplicaçäo de sutura linear cortante, por videolaparoscopia, obtendo-se resoluçäo miniinvasiva e rápida recuperaçäo da doente, que retornou a suas atividades emj 7 dias


Subject(s)
Humans , Female , Abdomen, Acute , Diverticulitis , Laparoscopy
10.
Rev. Col. Bras. Cir ; 26(2): 119-21, mar.-abr. 1999. ilus
Article in Portuguese | LILACS | ID: lil-271047

ABSTRACT

Os autores apresentam a proposta de utilização de fitas de nylon (braçadeiras) em cirurgias videoendoscópicas ou convencionais. Estas braçadeiras foram idealizadas para amarração de cabos elétricos. Efetuaram estudo experimental em ratos brancos (teste de comportamento biológico) e cães (ligaduras vasculares e de intestino) com bom resultado técnico e demonstrando escassa reação tecidual na presença deste material. Ficaram confirmadas a exequibilidade, a praticidade, a segurança e a economia na utilização das mesmas, sugerindo que possam ser aceitas como um método alternativo na prática cirúrgica


Subject(s)
Animals , Dogs , Rats , Hepatectomy , Nylons
11.
Rev. bras. colo-proctol ; 19(1): 24-6, jan.-mar. 1999. ilus
Article in Portuguese | LILACS | ID: lil-282469

ABSTRACT

Os autores apresentam a proposta de utilizaçäo de "fitas de nylon" (braçadeiras) em cirurgias vídeo-endoscópicas ou convencionais. Estas braçadeiras foram idealizadas para amarraçäo de cabos elétricos. Efetuaram estudo experimental em ratos brancos (teste de comportamento biológico) e cäes (ligaduras vasculares e de intestino) com bom resultado técnico, e demonstrando escassa reaçäo tecidual à presença deste material. Ficou confirmada a exequibilidade, a praticidade, a segurança e a economia na utilizaçäo das mesmas, sugerindo que possam ser aceitas como um método alternativo na prática cirúrgica


Subject(s)
Animals , Dogs , Rats , Hemostasis, Surgical/instrumentation , Surgical Instruments , Nylons , Laparoscopy , Ligation/instrumentation , Thoracoscopy
12.
Rev. bras. colo-proctol ; 12(2): 56-60, abr.-jun. 1992. tab
Article in Portuguese | LILACS | ID: lil-119506

ABSTRACT

Analisamos sete casos de pacientes submetidos a resseçao hepatica de metastases de cancer colorretal.A apresentaçao das metastases foi metacronica em seis casos e sincronica em um. As lesoes situavam-se no lobo direito em seis oportunidades e no lobo esquerdo em uma. A dosagem previa de antigeno carcinoembrionico (CEA) serico estava elevada em quatro pacientes. O diagnostico foi realizado atraves de queixas clinicas em quatro pacientes e por exame de controle em outros tres. Todos tiveram suas lesoes ressecadas com margem cirurgicas adequadas e nao foram constatadas metastases extra-hepaticas intra-abdominais durante a ressecçao. Nao houve mortalidade operatoria. Cinco pacientes faleceram durante o seguimento, com sobrevivencia de 23,4 meses. Tres destes pacientes morreram por recidiva neoplasica. Dois permaneceram vivos assintomaticos e livres de doença ha cerca de sete meses em um caso e 37 meses em outro, apos a resseçao de suas metastases hepaticas. O prognostico do pacinete portador de metastase hepaticas de cancer colorretal esta na dependencia do numero de metastases, da margem cirurgica adequada, do intervalo de tempo entre a ressecçao do cancer colorretal primario e o aparecimento das lesoes hepaticas e principalmente da presença de metastases extra-hepaticas. A opçao pela hepatectomia deve ser realizada apos a avaliaçao individual dse cada paciente.


Subject(s)
Humans , Female , Male , Adult , Middle Aged , Colonic Neoplasms , Neoplasm Metastasis , Rectal Neoplasms , Brazil
13.
GED gastroenterol. endosc. dig ; 10(3): 111-3, jul.-set. 1991.
Article in Portuguese | LILACS | ID: lil-117609

ABSTRACT

Os autores apresentam os resultados de 17 casos de colecistites calculosas com evoluçäo aguda (13,2%), escleroatrofia (1,9%) ou hidropsia (0,9%), operados por via laparoscópica, de dezembro de 1989 a janeiro de 1991, no Hospital Quirúrgic Adrià (ICS), em Barcelona (Espanha). Nesse período, foram selecioandos para cirurgia por via laparoscópica 106 pacientes portadores de colecistites calculosas, sendo que em 17 (16%) deles a vesícula biliar apresentava uma evoluçäo que poderia tornar a técnica laparoscópica inexeqüível; porém, ela foi usada em 14/17 (82%), näo sendo possível em apenas 3/17 (18%). Os motivos dos insucessos foram sangramento da artéria cística (1/17 (5,9%); dificuldades anatômicas, 1/17 (5,9%); e 1/17 (5,9%) com sindrome de Mirizzi, necrose do hepatocolédoco e coledocolitíase, tendo-se efetuado coledocolitotomia e colocaçäo de dreno de Kehr, por laparotomia. Concluem como sendo a via laparoscópica uma maneira segura para se efetuar colecistectomia, näo somente nos casos eletivos, mas também nas colecistopatias agudas, nas escleroatróficas e nas hidrópicas, desde que realizada por cirurgiöes habilitados em cirurgias biliares e laparoscópicas


Subject(s)
Humans , Cholecystectomy , Laparoscopy , Cholecystitis/surgery
14.
GED gastroenterol. endosc. dig ; 4(1): 26-8, jan.-mar. 1985.
Article in Portuguese | LILACS | ID: lil-28788

ABSTRACT

Pacientes com hipertensäo portal podem apresentar sangramento por varizes gastroesofágicas ou por gastrite difusa. As descompressöes globais controlam efetivamente o sangramento por gastrite hemorrágica, mas determinam elevada incidência da encefalopatia portossistêmica e reduzem a sobrevida de pacientes näo alcoólatras. Apresenta-se um caso de paciente com cirrose näo alcoólica com varizes de esôfago controladas por escleroterapias sucessivas e que passou a apresentar hemorragia fulminante por gastrite hemorrágica, tendo sido submetido à descompressäo portal seletiva de urgência, com controle efetivo da hemorragia. Houve normalizaçäo dos achados da endoscopia gástrica realizada no 2§ mês de seguimento. O paciente encontra-se no 12§ mês de seguimento, com sinais de insuficiência hepática progressiva, mas sem recidiva hemorrágica


Subject(s)
Middle Aged , Humans , Male , Liver Cirrhosis/physiopathology , Gastrointestinal Hemorrhage/surgery , Hypertension, Portal/surgery , Gastroscopy , Esophageal and Gastric Varices/prevention & control
SELECTION OF CITATIONS
SEARCH DETAIL